{"canonical":"https://sealedbidder.com/opportunities/w68md943476352","key":"W68MD943476352","url":"https://sealedbidder.com/opportunities/w68md943476352","title":"Powerhouse Drainage Sump Oil Skimmer and Day Tank Replacement - Oil Remover and Transfer System (ORTS)","solicitation_number":"W68MD943476352","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-14T13:00:00Z","first_posted":"2025-02-03","last_posted":"2025-02-03","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W071 ENDIST SEATTLE","naics":"333914","psc":"4330","set_aside":"SBA","place_state":"WA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"53017","place_county_name":"Douglas County","place_city":"5307870","place_city_name":"Bridgeport","winner":null,"award_amount":null,"publications":[{"notice_id":"8a536732c2b04f2bb293f049fb590b2d","title":"Powerhouse Drainage Sump Oil Skimmer and Day Tank Replacement - Oil Remover and Transfer System (ORTS)","solicitation_number":"W68MD943476352","notice_type":"r","base_type":"r","posted":"2025-02-03","posted_at":"2025-02-03T19:17:19.479Z","due_at":"2025-02-14T13:00:00Z","due_date":"2025-02-14","cancelled":false,"archived":true,"archive_date":"2025-03-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8a536732c2b04f2bb293f049fb590b2d/view","enriched":true,"history":[{"index":3,"title":"Powerhouse Drainage Sump Oil Skimmer and Day Tank Replacement - Oil Remover and Transfer System (ORTS)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-03T19:17:19.479Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"8a536732c2b04f2bb293f049fb590b2d","solicitation_number":"W68MD943476352"}]}],"latest_notice_id":"8a536732c2b04f2bb293f049fb590b2d","first_type":"r","notices":[{"dates":{"posted":"2025-02-03","posted_at":"2025-02-03T19:17:19.479Z","created_at":"2025-02-03T18:17:12.712Z","modified_at":"2025-03-01T05:04:24.737Z","response_deadline":{"raw":"2025-02-14T08:00:00-05:00","utc":"2025-02-14T13:00:00Z","date":"2025-02-14","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8a536732c2b04f2bb293f049fb590b2d/view"},"naics":{"codes":["333914"],"primary":"333914"},"title":"Powerhouse Drainage Sump Oil Skimmer and Day Tank Replacement - Oil Remover and Transfer System (ORTS)","agency":{"office":{"code":"W912DW","name":"W071 ENDIST SEATTLE"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"98134-2329","city":"SEATTLE","state":"WA","country":"USA"},"organization_id":"100221304","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-01","archive_type":"auto15"},"history":[{"index":3,"title":"Powerhouse Drainage Sump Oil Skimmer and Day Tank Replacement - Oil Remover and Transfer System (ORTS)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-03T19:17:19.479Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"8a536732c2b04f2bb293f049fb590b2d","solicitation_number":"W68MD943476352"}],"contacts":[{"name":"Della S. Overton","role":"primary","email":"della.s.overton@usace.army.mil","phone":"(206) 764-6170"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"8a536732c2b04f2bb293f049fb590b2d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"8a536732c2b04f2bb293f049fb590b2d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T01:24:05.803056024Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a63488a3893b6e37e21b530178fb36751d5f2dfb40a0f409654f892d93d447d1","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T01:24:05.803056024Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>The vendor shall provide a complete oil skimmer system which meets the specifications listed below.&nbsp; All components shall be new, and the skimmer system shall be shipped to the US Army Corps of Engineers at Chief Joseph Dam in Bridgeport, WA 98813. The oil skimmer system shall consist of a tube type oil skimmer, decanter, and a 100-gallon day tank for collecting the oil and water from the decanter.</p>\n\n<p>Specifications:</p>\n\n<p>Vertical tube type skimmer with integrated decanter and collection tank.</p>\n\n<p>The collection tank shall be stainless steel.</p>\n\n<p>Collection tank shall have a capacity between 65 (minimum) and 100 (maximum) gallons.</p>\n\n<p>The skimmer must automatically transfer recovered oil to collection tank.</p>\n\n<p>The collection tank must have a float switch which automatically shuts off the oil skimmer when full.</p>\n\n<p>The The skimmer must have both an audible annunciation and indicator lamps in the event the skimmer shuts down or loses power.</p>\n\n<p>The collection tank must have both an indicator lamp and audible alarm when full.</p>\n\n<p>The collection tank must have liquid level indicator lamps to signal when the unit is 3/4 full and when full.</p>\n\n<p>The collection tank must have a manually activated electris pump for transferring oil and water to &quot;used oil&quot; drums once the collection tank is full.</p>\n\n<p>The skimmer must automatically return the water separated from the oil to the sump.</p>\n\n<p>The skimmer must use a free-floating closed loop oil collector tune to recover oil from the water surface.</p>\n\n<p>The oil collector tube must operate without requiring any mounts or guides installed in sump.</p>\n\n<p>The skimmer system must be capable of recovering 65-100 gallons/hour.</p>\n\n<p>The skimmer with integrated decanter and collection tank shall be mounted on a skid (as an all-in-one oil skimmer system).</p>\n\n<p>The skid shall have holes for mounting to a concrete floor or base (stationary installation).</p>\n\n<p>All components of the skimmer system must be designed to operate continously (24/7).</p>\n\n<p>The skimmer and collector tube must recover oil from a sump with fluctuating water levels (the normal operating level for the sump is 15 to 35 feet from the finished floor).</p>\n\n<p>The collector tube must extend 35 feer from the finished floor into a drainage sump.</p>\n\n<p>The required overall length for the collector tube is estimated at 78 feet based on the old skimmer (will need to work with vendor to determine optium length based on final installation).</p>\n\n<p>The collector tube must be resistant to tangling up on itself while floating on water surface.</p>\n\n<p>The collector tube must operate within the existing sump opening (30 inches center to center).</p>\n\n<p>The entire skid mounted skimmer system must fit within the existing skimmer system footprint of 30 inches x 74 inches.</p>\n\n<p>The power requirement is 120 VAC single phase.</p>\n\n<p>The skimmer system shall have a NEMA control box to house components for power, timers, lights, level switches, etc.</p>\n\n<p>All local alarms and indicator lamps much allow duplication to a remote annunciation panel.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"The vendor shall provide a complete oil skimmer system which meets the specifications listed below. All components shall be new, and the skimmer system shall be shipped to the US Army Corps of Engineers at Chief Joseph Dam in Bridgeport, WA 98813. The oil skimmer system shall consist of a tube type oil skimmer, decanter, and a 100-gallon day tank for collecting the oil and water from the decanter.\n\nSpecifications:\n\nVertical tube type skimmer with integrated decanter and collection tank.\n\nThe collection tank shall be stainless steel.\n\nCollection tank shall have a capacity between 65 (minimum) and 100 (maximum) gallons.\n\nThe skimmer must automatically transfer recovered oil to collection tank.\n\nThe collection tank must have a float switch which automatically shuts off the oil skimmer when full.\n\nThe The skimmer must have both an audible annunciation and indicator lamps in the event the skimmer shuts down or loses power.\n\nThe collection tank must have both an indicator lamp and audible alarm when full.\n\nThe collection tank must have liquid level indicator lamps to signal when the unit is 3/4 full and when full.\n\nThe collection tank must have a manually activated electris pump for transferring oil and water to \"used oil\" drums once the collection tank is full.\n\nThe skimmer must automatically return the water separated from the oil to the sump.\n\nThe skimmer must use a free-floating closed loop oil collector tune to recover oil from the water surface.\n\nThe oil collector tube must operate without requiring any mounts or guides installed in sump.\n\nThe skimmer system must be capable of recovering 65-100 gallons/hour.\n\nThe skimmer with integrated decanter and collection tank shall be mounted on a skid (as an all-in-one oil skimmer system).\n\nThe skid shall have holes for mounting to a concrete floor or base (stationary installation).\n\nAll components of the skimmer system must be designed to operate continously (24/7).\n\nThe skimmer and collector tube must recover oil from a sump with fluctuating water levels (the normal operating level for the sump is 15 to 35 feet from the finished floor).\n\nThe collector tube must extend 35 feer from the finished floor into a drainage sump.\n\nThe required overall length for the collector tube is estimated at 78 feet based on the old skimmer (will need to work with vendor to determine optium length based on final installation).\n\nThe collector tube must be resistant to tangling up on itself while floating on water surface.\n\nThe collector tube must operate within the existing sump opening (30 inches center to center).\n\nThe entire skid mounted skimmer system must fit within the existing skimmer system footprint of 30 inches x 74 inches.\n\nThe power requirement is 120 VAC single phase.\n\nThe skimmer system shall have a NEMA control box to house components for power, timers, lights, level switches, etc.\n\nAll local alarms and indicator lamps much allow duplication to a remote annunciation panel.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W68MD943476352","place_of_performance":{"zip":"98813","city":{"code":"7870","name":"Bridgeport"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4330"}],"due_at":"2025-02-14T13:00:00Z","due_date":"2025-02-14","closes_at":"2025-02-14T13:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DW","office_name":"W071 ENDIST SEATTLE","state":"WA","county":"53017","county_name":"Douglas County","city":"5307870","city_name":"Bridgeport","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-24T01:36:58.141327Z","principal_notice_id":"8a536732c2b04f2bb293f049fb590b2d","description":{"text":"The vendor shall provide a complete oil skimmer system which meets the specifications listed below. All components shall be new, and the skimmer system shall be shipped to the US Army Corps of Engineers at Chief Joseph Dam in Bridgeport, WA 98813. The oil skimmer system shall consist of a tube type oil skimmer, decanter, and a 100-gallon day tank for collecting the oil and water from the decanter.\n\nSpecifications:\n\nVertical tube type skimmer with integrated decanter and collection tank.\n\nThe collection tank shall be stainless steel.\n\nCollection tank shall have a capacity between 65 (minimum) and 100 (maximum) gallons.\n\nThe skimmer must automatically transfer recovered oil to collection tank.\n\nThe collection tank must have a float switch which automatically shuts off the oil skimmer when full.\n\nThe The skimmer must have both an audible annunciation and indicator lamps in the event the skimmer shuts down or loses power.\n\nThe collection tank must have both an indicator lamp and audible alarm when full.\n\nThe collection tank must have liquid level indicator lamps to signal when the unit is 3/4 full and when full.\n\nThe collection tank must have a manually activated electris pump for transferring oil and water to \"used oil\" drums once the collection tank is full.\n\nThe skimmer must automatically return the water separated from the oil to the sump.\n\nThe skimmer must use a free-floating closed loop oil collector tune to recover oil from the water surface.\n\nThe oil collector tube must operate without requiring any mounts or guides installed in sump.\n\nThe skimmer system must be capable of recovering 65-100 gallons/hour.\n\nThe skimmer with integrated decanter and collection tank shall be mounted on a skid (as an all-in-one oil skimmer system).\n\nThe skid shall have holes for mounting to a concrete floor or base (stationary installation).\n\nAll components of the skimmer system must be designed to operate continously (24/7).\n\nThe skimmer and collector tube must recover oil from a sump with fluctuating water levels (the normal operating level for the sump is 15 to 35 feet from the finished floor).\n\nThe collector tube must extend 35 feer from the finished floor into a drainage sump.\n\nThe required overall length for the collector tube is estimated at 78 feet based on the old skimmer (will need to work with vendor to determine optium length based on final installation).\n\nThe collector tube must be resistant to tangling up on itself while floating on water surface.\n\nThe collector tube must operate within the existing sump opening (30 inches center to center).\n\nThe entire skid mounted skimmer system must fit within the existing skimmer system footprint of 30 inches x 74 inches.\n\nThe power requirement is 120 VAC single phase.\n\nThe skimmer system shall have a NEMA control box to house components for power, timers, lights, level switches, etc.\n\nAll local alarms and indicator lamps much allow duplication to a remote annunciation panel.","html":"<p>The vendor shall provide a complete oil skimmer system which meets the specifications listed below.&nbsp; All components shall be new, and the skimmer system shall be shipped to the US Army Corps of Engineers at Chief Joseph Dam in Bridgeport, WA 98813. The oil skimmer system shall consist of a tube type oil skimmer, decanter, and a 100-gallon day tank for collecting the oil and water from the decanter.</p>\n\n<p>Specifications:</p>\n\n<p>Vertical tube type skimmer with integrated decanter and collection tank.</p>\n\n<p>The collection tank shall be stainless steel.</p>\n\n<p>Collection tank shall have a capacity between 65 (minimum) and 100 (maximum) gallons.</p>\n\n<p>The skimmer must automatically transfer recovered oil to collection tank.</p>\n\n<p>The collection tank must have a float switch which automatically shuts off the oil skimmer when full.</p>\n\n<p>The The skimmer must have both an audible annunciation and indicator lamps in the event the skimmer shuts down or loses power.</p>\n\n<p>The collection tank must have both an indicator lamp and audible alarm when full.</p>\n\n<p>The collection tank must have liquid level indicator lamps to signal when the unit is 3/4 full and when full.</p>\n\n<p>The collection tank must have a manually activated electris pump for transferring oil and water to &quot;used oil&quot; drums once the collection tank is full.</p>\n\n<p>The skimmer must automatically return the water separated from the oil to the sump.</p>\n\n<p>The skimmer must use a free-floating closed loop oil collector tune to recover oil from the water surface.</p>\n\n<p>The oil collector tube must operate without requiring any mounts or guides installed in sump.</p>\n\n<p>The skimmer system must be capable of recovering 65-100 gallons/hour.</p>\n\n<p>The skimmer with integrated decanter and collection tank shall be mounted on a skid (as an all-in-one oil skimmer system).</p>\n\n<p>The skid shall have holes for mounting to a concrete floor or base (stationary installation).</p>\n\n<p>All components of the skimmer system must be designed to operate continously (24/7).</p>\n\n<p>The skimmer and collector tube must recover oil from a sump with fluctuating water levels (the normal operating level for the sump is 15 to 35 feet from the finished floor).</p>\n\n<p>The collector tube must extend 35 feer from the finished floor into a drainage sump.</p>\n\n<p>The required overall length for the collector tube is estimated at 78 feet based on the old skimmer (will need to work with vendor to determine optium length based on final installation).</p>\n\n<p>The collector tube must be resistant to tangling up on itself while floating on water surface.</p>\n\n<p>The collector tube must operate within the existing sump opening (30 inches center to center).</p>\n\n<p>The entire skid mounted skimmer system must fit within the existing skimmer system footprint of 30 inches x 74 inches.</p>\n\n<p>The power requirement is 120 VAC single phase.</p>\n\n<p>The skimmer system shall have a NEMA control box to house components for power, timers, lights, level switches, etc.</p>\n\n<p>All local alarms and indicator lamps much allow duplication to a remote annunciation panel.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Della S. Overton","role":"primary","email":"della.s.overton@usace.army.mil","phone":"(206) 764-6170"}],"place_of_performance":{"zip":"98813","city":{"code":"7870","name":"Bridgeport"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"98134-2329","city":"SEATTLE","state":"WA","country":"USA"},"naics_codes":["333914"],"award":null,"attachments":[{"resource_id":"641e77965dde4e4c986a5e520c5e1ebd","name":"Purchase Description Oil Skimmer Specs.docx","kind":"file","mime_type":".docx","size_bytes":15173,"posted_at":"2025-02-03T19:17:19.479Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/641e77965dde4e4c986a5e520c5e1ebd/download","mirrored":false},{"resource_id":"c7d6af1d9e064b5b849e8d17029859fb","name":"CJD Powerhouse Sump Techincal Drawing - 950087.pdf","kind":"file","mime_type":".pdf","size_bytes":40230,"posted_at":"2025-02-03T19:17:19.479Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c7d6af1d9e064b5b849e8d17029859fb/download","mirrored":false},{"resource_id":"2344665b3d0444ffbff025568bd1bd3f","name":"CJD Powerhouse Sump Technical Drawing - 950088.pdf","kind":"file","mime_type":".pdf","size_bytes":28794,"posted_at":"2025-02-03T19:17:19.479Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2344665b3d0444ffbff025568bd1bd3f/download","mirrored":false}],"awards":[],"related":[{"key":"W912DW27RA009","latest_notice_id":"484c94f05a504ed69a612be437e0d2ec","title":"Albeni Falls Dam Breakroom Upgrade","solicitation_number":"W912DW27RA009","notice_type":"o","first_type":"o","first_posted":"2026-10-26","last_posted":"2026-10-26","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DW","office_name":"W071 ENDIST SEATTLE","naics":"237990","psc":"Z2JZ","set_aside":null,"state":"ID","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"ALBENI FALLS DAM POWERHOUSE 2376 E. HIGHWAY 2, OLDTOWN, ID 83822","site":"Albeni Falls Dam","site_key":"albeni-falls-dam-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-10-28T04:57:21.121242Z"},{"key":"W912DW27QA006","latest_notice_id":"d79427ee4ca2483697db671e9a692aa4","title":"Mud Mountain Dam Sewage Lagoon Repair","solicitation_number":"W912DW27QA006","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DW","office_name":"W071 ENDIST SEATTLE","naics":"237110","psc":"Z2ND","set_aside":"SBA","state":"WA","county":"53033","county_name":"King County","city":"5322045","city_name":"Enumclaw","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W912DW27RA011","latest_notice_id":"6b9f6a0ddd3b49e9ac62b28b95e89f26","title":"$300M Indefinite Delivery / Indefinite Quantity (IDIQ) Multiple Award Task Order Contract (MATOC) for Facilities Sustainment, Restoration, and Modernization (FSRM) Program at Joint Base Lewis-McChord (JBLM)","solicitation_number":"W912DW27RA011","notice_type":"r","first_type":"r","first_posted":"2026-08-26","last_posted":"2026-11-17","notices":4,"due_at":"2026-12-01T22:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DW","office_name":"W071 ENDIST SEATTLE","naics":"236220","psc":"Y1JZ","set_aside":null,"state":"WA","county":"53053","county_name":"Pierce County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Joint Base Lewis-McChord","site_key":"joint-base-lewis-mcchord-wa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"W912DW27RA014","latest_notice_id":"365a0af20ef74105bf6b4bcde03def94","title":"JOINT BASE LEWIS MCCHORD MULTI DOMAIN TASK FORCE BUILDINGS 3223-3224, WASHINGTON","solicitation_number":"W912DW27RA014","notice_type":"o","first_type":"p","first_posted":"2026-09-16","last_posted":"2026-11-06","notices":6,"due_at":"2026-12-11T19:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DW","office_name":"W071 ENDIST SEATTLE","naics":"236220","psc":"Y1AZ","set_aside":"SBA","state":"WA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Joint Base Lewis-McChord","site_key":"joint-base-lewis-mcchord-wa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"DACA675270004100","latest_notice_id":"49c305eeee174fe19d0f4f0775dbebbf","title":"DACA675270004100 - United States Army Corps of Engineers (USACE) seeks to lease approximately 628 square feet of retail space in Aberdeen, WA for an Armed Forces Career Center","solicitation_number":"DACA675270004100","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-15T07:59:00Z","due_date":"2026-12-14","closes_at":"2026-12-15T07:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DW","office_name":"W071 ENDIST SEATTLE","naics":"531120","psc":"X1AA","set_aside":null,"state":"WA","county":"53027","county_name":"Grays Harbor County","city":"5300100","city_name":"Aberdeen","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"N0010426RTB38","latest_notice_id":"cf2e4b18b9214a48975c863638132efc","title":"43--PUMP UNIT,CENTRIFUG, IN REPAIR/MODIFICATION OF","solicitation_number":"N0010426RTB38","notice_type":"p","first_type":"p","first_posted":"2026-06-04","last_posted":"2026-10-28","notices":8,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333914","psc":"4320","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"PP, TDP VER 004, QTY 10 EA, DELIVERY FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"N0010423RCD46","latest_notice_id":"03a7faaf0402477eabf291b681baca9d","title":"43--PUMP/MOTOR ASSY","solicitation_number":"N0010423RCD46","notice_type":"o","first_type":"o","first_posted":"2026-02-05","last_posted":"2026-10-28","notices":10,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333914","psc":"4320","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4320)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"N0038327QHA10","latest_notice_id":"880448abee81427d8a3fec2b6506e5b8","title":"43--PUMP,RECIPROCATING, IN REPAIR/MODIFICATION OF","solicitation_number":"N0038327QHA10","notice_type":"o","first_type":"p","first_posted":"2026-10-09","last_posted":"2026-10-27","notices":2,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00383","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT","naics":"333914","psc":"4320","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4320)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-28T04:01:09.175983Z"}],"similar_open_total":54,"indexable":false}