{"canonical":"https://sealedbidder.com/opportunities/w564kv25rmwqmd","key":"W564KV25RMWQMD","url":"https://sealedbidder.com/opportunities/w564kv25rmwqmd","title":"Maint. Water Quality Measuring Devices","solicitation_number":"W564KV-25-R-MWQMD","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-23T13:00:00Z","first_posted":"2025-06-02","last_posted":"2025-06-02","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"409TH CSB","naics":"561210","psc":"J046","set_aside":null,"place_state":null,"place_scope":"overseas","site":null,"place_state_source":null,"place_evidence":"GERMANY","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"ab09e2b13f31484b9b50ab3763227c5e","title":"Maint. Water Quality Measuring Devices","solicitation_number":"W564KV-25-R-MWQMD","notice_type":"s","base_type":"s","posted":"2025-06-02","posted_at":"2025-06-02T10:38:42.092Z","due_at":"2025-06-23T13:00:00Z","due_date":"2025-06-23","cancelled":false,"archived":true,"archive_date":"2026-06-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ab09e2b13f31484b9b50ab3763227c5e/view","enriched":true,"history":[{"index":3,"title":"Maint. Water Quality Measuring Devices","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-02T10:38:42.092Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"ab09e2b13f31484b9b50ab3763227c5e","solicitation_number":"W564KV-25-R-MWQMD"}]}],"latest_notice_id":"ab09e2b13f31484b9b50ab3763227c5e","first_type":"s","notices":[{"dates":{"posted":"2025-06-02","posted_at":"2025-06-02T10:38:42.092Z","created_at":"2025-06-02T09:54:13.068Z","modified_at":"2026-06-24T03:55:45.517Z","response_deadline":{"raw":"2025-06-23T15:00:00+02:00","utc":"2025-06-23T13:00:00Z","date":"2025-06-23","time":"15:00:00","timezone":"Europe/Berlin","utc_offset_seconds":7200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ab09e2b13f31484b9b50ab3763227c5e/view"},"naics":{"codes":["561210"],"primary":"561210"},"title":"Maint. Water Quality Measuring Devices","agency":{"office":{"name":"409TH CSB"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"organization_id":"500045602","organization_type":"SUB COMMAND"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-23","archive_type":"auto_custom"},"history":[{"index":3,"title":"Maint. Water Quality Measuring Devices","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-02T10:38:42.092Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"ab09e2b13f31484b9b50ab3763227c5e","solicitation_number":"W564KV-25-R-MWQMD"}],"contacts":[{"name":"Ryan Peacock","role":"primary","email":"ryan.e.peacock4.civ@army.mil","phone":"4906111435426861"},{"name":"Andre Carvalho dos Santos","role":"secondary","email":"andre.carvalhodossantos.ln@army.mil","phone":"09641-70-542-6852"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"ab09e2b13f31484b9b50ab3763227c5e","lineage_id":"ab09e2b13f31484b9b50ab3763227c5e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-13T08:57:28.508698863Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"dee7af34676c37ad0fd23cbe18b38dca5c7cb560d4021a8d1b7d7f315631cef5","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-13T08:57:28.508698863Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>The purpose of this Requirement is to maintain the water quality parameters given by German and US drinking water standards, the measurement devices must be precisely calibrated and operational IAW with the attached draft Performance Work Statement (PWS).&nbsp;This posting is for the purposes of Market research only.&nbsp;</p>\n\n<p>This requirement is intended for local sources IAW FAR 5.202.&nbsp;</p>\n\n<p><strong>Please Answer the following Questions:&nbsp;</strong></p>\n\n<p>Question 1: We anticipate an Lowest Price Technically Acceptable (LPTA) based on PWS paragraph 1.10 (d), other Water Management Act documents may apply in order to perform work on Water flowmeters. Is your Company aware of the necessary Certifications and are they able to maintain them in order to comply with the PWS?&nbsp;</p>\n\n<p>Question 2: Given the following price ranges based on the PWS which is the most realistic?</p>\n\n<ul>\n\t<li>EUR 60,000.00 - 70,000.00</li>\n\t<li>EUR 70,000.00 - 80,000.00</li>\n\t<li>EUR 80,000.00 - 90,000.00</li>\n</ul>\n\n<p></p>\n\n<p>Question 3: Based on the current CLIN structure, are there any changes that would better suit the requirement as specified in the PWS?</p>\n\n<ul>\n\t<li>0001 MID&rsquo;s (Magnet inductive flowmeters) Job, FFP, FOB Destination&nbsp;</li>\n\t<li>0002 Devices (burst &amp; leak pipe detect &amp; lab) Job, FFP, FOB Destination</li>\n\t<li>0003 Depolox, Job, FFP, FOB Destination</li>\n\t<li>0004 Unforeseen Repair Work (IAW PWS Para.5.2.1), Job, T&amp;M, FOB Destination</li>\n</ul>\n\n<p></p>\n\n<p>Question 4: Are there any other comments and/or information you would like the Government to know regarding this requirement?</p>\n\n<p>Please leave a valid email address if you are interested in future consideration for this requirement.&nbsp;</p>\n\n<p>Thank you.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"The purpose of this Requirement is to maintain the water quality parameters given by German and US drinking water standards, the measurement devices must be precisely calibrated and operational IAW with the attached draft Performance Work Statement (PWS). This posting is for the purposes of Market research only.\n\nThis requirement is intended for local sources IAW FAR 5.202.\n\nPlease Answer the following Questions:\n\nQuestion 1: We anticipate an Lowest Price Technically Acceptable (LPTA) based on PWS paragraph 1.10 (d), other Water Management Act documents may apply in order to perform work on Water flowmeters. Is your Company aware of the necessary Certifications and are they able to maintain them in order to comply with the PWS?\n\nQuestion 2: Given the following price ranges based on the PWS which is the most realistic?\n\n• EUR 60,000.00 - 70,000.00\n\n• EUR 70,000.00 - 80,000.00\n\n• EUR 80,000.00 - 90,000.00\n\nQuestion 3: Based on the current CLIN structure, are there any changes that would better suit the requirement as specified in the PWS?\n\n• 0001 MID’s (Magnet inductive flowmeters) Job, FFP, FOB Destination\n\n• 0002 Devices (burst & leak pipe detect & lab) Job, FFP, FOB Destination\n\n• 0003 Depolox, Job, FFP, FOB Destination\n\n• 0004 Unforeseen Repair Work (IAW PWS Para.5.2.1), Job, T&M, FOB Destination\n\nQuestion 4: Are there any other comments and/or information you would like the Government to know regarding this requirement?\n\nPlease leave a valid email address if you are interested in future consideration for this requirement.\n\nThank you.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"W564KV-25-R-MWQMD","place_of_performance":{"zip":"55774","city":{"code":"Baumholder","name":"Baumholder"},"state":{"code":"DE-RP","name":"Rhineland-Palatinate"},"country":{"code":"DEU","name":"GERMANY"}},"product_service_code":"J046"}],"due_at":"2025-06-23T13:00:00Z","due_date":"2025-06-23","closes_at":"2025-06-23T13:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-n-409THCSB","office_name":"409TH CSB","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"DEU","state_source":null,"state_evidence":"GERMANY","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-13T09:35:56.908272Z","principal_notice_id":"ab09e2b13f31484b9b50ab3763227c5e","description":{"text":"The purpose of this Requirement is to maintain the water quality parameters given by German and US drinking water standards, the measurement devices must be precisely calibrated and operational IAW with the attached draft Performance Work Statement (PWS). This posting is for the purposes of Market research only.\n\nThis requirement is intended for local sources IAW FAR 5.202.\n\nPlease Answer the following Questions:\n\nQuestion 1: We anticipate an Lowest Price Technically Acceptable (LPTA) based on PWS paragraph 1.10 (d), other Water Management Act documents may apply in order to perform work on Water flowmeters. Is your Company aware of the necessary Certifications and are they able to maintain them in order to comply with the PWS?\n\nQuestion 2: Given the following price ranges based on the PWS which is the most realistic?\n\n• EUR 60,000.00 - 70,000.00\n\n• EUR 70,000.00 - 80,000.00\n\n• EUR 80,000.00 - 90,000.00\n\nQuestion 3: Based on the current CLIN structure, are there any changes that would better suit the requirement as specified in the PWS?\n\n• 0001 MID’s (Magnet inductive flowmeters) Job, FFP, FOB Destination\n\n• 0002 Devices (burst & leak pipe detect & lab) Job, FFP, FOB Destination\n\n• 0003 Depolox, Job, FFP, FOB Destination\n\n• 0004 Unforeseen Repair Work (IAW PWS Para.5.2.1), Job, T&M, FOB Destination\n\nQuestion 4: Are there any other comments and/or information you would like the Government to know regarding this requirement?\n\nPlease leave a valid email address if you are interested in future consideration for this requirement.\n\nThank you.","html":"<p>The purpose of this Requirement is to maintain the water quality parameters given by German and US drinking water standards, the measurement devices must be precisely calibrated and operational IAW with the attached draft Performance Work Statement (PWS).&nbsp;This posting is for the purposes of Market research only.&nbsp;</p>\n\n<p>This requirement is intended for local sources IAW FAR 5.202.&nbsp;</p>\n\n<p><strong>Please Answer the following Questions:&nbsp;</strong></p>\n\n<p>Question 1: We anticipate an Lowest Price Technically Acceptable (LPTA) based on PWS paragraph 1.10 (d), other Water Management Act documents may apply in order to perform work on Water flowmeters. Is your Company aware of the necessary Certifications and are they able to maintain them in order to comply with the PWS?&nbsp;</p>\n\n<p>Question 2: Given the following price ranges based on the PWS which is the most realistic?</p>\n\n<ul>\n\t<li>EUR 60,000.00 - 70,000.00</li>\n\t<li>EUR 70,000.00 - 80,000.00</li>\n\t<li>EUR 80,000.00 - 90,000.00</li>\n</ul>\n\n<p></p>\n\n<p>Question 3: Based on the current CLIN structure, are there any changes that would better suit the requirement as specified in the PWS?</p>\n\n<ul>\n\t<li>0001 MID&rsquo;s (Magnet inductive flowmeters) Job, FFP, FOB Destination&nbsp;</li>\n\t<li>0002 Devices (burst &amp; leak pipe detect &amp; lab) Job, FFP, FOB Destination</li>\n\t<li>0003 Depolox, Job, FFP, FOB Destination</li>\n\t<li>0004 Unforeseen Repair Work (IAW PWS Para.5.2.1), Job, T&amp;M, FOB Destination</li>\n</ul>\n\n<p></p>\n\n<p>Question 4: Are there any other comments and/or information you would like the Government to know regarding this requirement?</p>\n\n<p>Please leave a valid email address if you are interested in future consideration for this requirement.&nbsp;</p>\n\n<p>Thank you.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Ryan Peacock","role":"primary","email":"ryan.e.peacock4.civ@army.mil","phone":"4906111435426861"},{"name":"Andre Carvalho dos Santos","role":"secondary","email":"andre.carvalhodossantos.ln@army.mil","phone":"09641-70-542-6852"}],"place_of_performance":{"zip":"55774","city":{"code":"Baumholder","name":"Baumholder"},"state":{"code":"DE-RP","name":"Rhineland-Palatinate"},"country":{"code":"DEU","name":"GERMANY"}},"office_address":null,"naics_codes":["561210"],"award":null,"attachments":[{"resource_id":"b079e30ab87f47579c4f7c6ae0b5a6a4","name":"PWS Maintenance and Repair Water Measuring Device Draft.docx","kind":"file","mime_type":".docx","size_bytes":137353,"posted_at":"2025-06-02T10:38:42.092Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b079e30ab87f47579c4f7c6ae0b5a6a4/download","mirrored":false}],"awards":[],"related":[],"similar_open":[{"key":"W91QVP26AS27BLS","latest_notice_id":"23f9de65d8fc4ab2be236b3307de2f7d","title":"ANGKOR SENTINEL 27 BASE LIFE SUPPORT FACILITY REHAB SERVICES","solicitation_number":"W91QVP-26-AS27-BLS","notice_type":"k","first_type":"k","first_posted":"2026-10-23","last_posted":"2026-11-13","notices":4,"due_at":"2026-11-27T23:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W91QVP","office_name":"0413 AQ HQ CONTRACT AUG","naics":"561210","psc":"S216","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"KHM","place_scope":"overseas","state_source":null,"state_evidence":"CAMBODIA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"FA805127R0001","latest_notice_id":"34d2b95fb5e24584877e7203f17213cd","title":"Air Force Contract Augmentation Program (AFCAP) VI","solicitation_number":"FA805127R0001","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-09","notices":5,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8051","office_name":"FA8051 772 ESS PKD","naics":"561210","psc":"S216","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"WITHIN THE CONTIGUOUS UNITED STATES (CONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"W51DQV27S1CQK","latest_notice_id":"1be4ef39ffe34f9db71fdfd998ac72ce","title":"Facilities Operation and Maintenance Services U.S. Navy Medical Research Unit South (NAMRU-S) Lima and Iquitos, Peru","solicitation_number":"W51DQV27S1CQK","notice_type":"r","first_type":"r","first_posted":"2026-10-08","last_posted":"2026-11-16","notices":3,"due_at":"2026-12-10T14:00:00Z","due_date":"2026-12-10","closes_at":"2026-12-10T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W51DQV","office_name":"W2SR ENDIST CARIBBEAN(PROVIS)","naics":"561210","psc":"Z1DB","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"PER","place_scope":"overseas","state_source":null,"state_evidence":"PERU","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":40,"indexable":false}