Sources sought
Single-Axis Linear Motion Calibration System (Shake Table) with Control Software
SSN-CDRH-2026-133952
Food and Drug Administration, FDA Office of Acq Grant SVCS. Other Measuring and Controlling Device Manufacturing.
Response deadline
August 3, 2026 at 12:00 PM EDT
Closed 115 days ago. Posted July 20, 2026, first published July 20, 2026. Scheduled to archive August 4, 2026.
Get the next one like this from Food and Drug Administration by email, the day it is posted.Find my opportunities
This one closed in 2026
47 like it are open now in other measuring and controlling device manufacturing
- Request for Information (RFI): Vehicle Integrated Point Enhanced RADIAC (VIPER) - Tracked Ground Vehicles
Department of the Army, W6QK ACC-APG
PresolicitationNAICS 334519Ship to MDVIPER_27-TRACKCloses in 14 daysDec 10 - REFERENCE STANDARD,PHY
Defense Logistics Agency, DLA Aviation
Combined synopsis and solicitationSmall businessNAICS 334519Ship to the buyerSPE4A627U0220Due in 2 daysNov 27 - STARTER,MOTOR
Defense Logistics Agency, DLA Weapons Support
Combined synopsis and solicitationNAICS 334519Ship to the buyerSPE7L327T2652Due in 2 daysNov 27
All 47 open in other measuring and controlling device manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334519 (other measuring and controlling device manufacturing), means no more than 600 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation has been published under this number yet. The sources sought of July 20, 2026 is the earliest notice of the purchase.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The U.S. Food and Drug Administration requires one (1) complete, turnkey single-axis (one degree-of-freedom) linear motion calibration system, commonly described as a shake table, with control software, for laboratory calibration, verification, and validation testing of inertial measurement devices. The system shall be fully assembled, factory-tested, and factory-calibrated prior to shipment, requiring only unpacking, cable connection, and software installation by the end user.
The Government seeks sources able to provide a system meeting, at minimum, the following salient performance characteristics. These are stated in approximate terms for market research; the full minimum specification will accompany any resulting solicitation.
• Programmable single-axis linear motion under closed-loop position control with real-time feedback, capable of arbitrary user-defined waveforms including multi-frequency superposition of at least three simultaneous components. Pre-programmed, fixed-routine-only calibrators are not sought.
• A motion envelope on the order of 0.1 to 10 Hz in frequency, sub-millimeter to approximately twenty millimeters in displacement, and up to approximately one g in acceleration, with demonstrated small-amplitude positioning accuracy at the sub-millimeter level.
• An integrated position sensor and an integrated reference accelerometer, each factory calibrated with NIST-traceable certificates.
• Safety features including a hard-wired emergency stop, motion limits, over-current protection, and fault detection with automatic safe shutdown.
• Benchtop form factor suitable for standard laboratory power (110 to 120V, or universal input) without special power conditioning or floor reinforcement.
• Control software operable in a standalone configuration with no required internet, cloud, or subscription, a programmable interface compatible with MATLAB, Python, or an equivalent industry-standard environment, and non-proprietary data import and export.
• Software and electronic content conforming to Section 508 accessibility standards, supported by a Voluntary Product Accessibility Template or equivalent.
Estimated quantity: one (1) each. Anticipated delivery: within approximately 90 days after award. Place of delivery: FDA White Oak campus, Silver Spring, Maryland. Applicable standards: NIST-traceable calibration; Section 508. Installation, user training, technical documentation, and a commercial warranty are included in the anticipated requirement.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 20, 2026
Sources sought
Due August 3, 2026 at 12:00 PM EDT. SAM.gov, notice 6ec1edf9db7b43179dd10947c0b02c32
2 revisions on SAM
- July 20, 2026: publish, sources sought
- July 20, 2026: publish, sources sought
July 20, 2026
Sources sought
Due August 3, 2026 at 12:00 PM EDT. SAM.gov, notice c132e199aa064983925081b8ac5b2a97
2 revisions on SAM
- July 20, 2026: publish, sources sought
- July 20, 2026: publish, sources sought
Points of contact
- Reagan Davisreagan.davis@fda.hhs.gov3017960910