{"canonical":"https://sealedbidder.com/opportunities/ss260020346","key":"SS260020346","url":"https://sealedbidder.com/opportunities/ss260020346","title":"Transformer Oil Testing Services","solicitation_number":"SS-260020346","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-10T21:00:00Z","first_posted":"2025-10-29","last_posted":"2025-10-29","department":"ENERGY, DEPARTMENT OF","subagency":"ENERGY, DEPARTMENT OF","office":"PRINCETON LAB - DOE CONTRACTOR","naics":"541380","psc":"H291","set_aside":"LAS","place_state":"NJ","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"34021","place_county_name":"Mercer County","place_city":"3460900","place_city_name":"Princeton","winner":null,"award_amount":null,"publications":[{"notice_id":"ea60ec6f70b74ee79a96f66f9235afd3","title":"Transformer Oil Testing Services","solicitation_number":"SS-260020346","notice_type":"r","base_type":"r","posted":"2025-10-29","posted_at":"2025-10-29T20:46:17.198Z","due_at":"2025-11-10T21:00:00Z","due_date":"2025-11-10","cancelled":false,"archived":true,"archive_date":"2025-11-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ea60ec6f70b74ee79a96f66f9235afd3/view","enriched":true,"history":[{"index":3,"title":"Transformer Oil Testing Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-29T20:46:17.198Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ea60ec6f70b74ee79a96f66f9235afd3","solicitation_number":"SS-260020346"}]}],"latest_notice_id":"ea60ec6f70b74ee79a96f66f9235afd3","first_type":"r","notices":[{"dates":{"posted":"2025-10-29","posted_at":"2025-10-29T20:46:17.198Z","created_at":"2025-10-29T20:25:48.882Z","modified_at":"2025-11-26T04:55:45.868Z","response_deadline":{"raw":"2025-11-10T16:00:00-05:00","utc":"2025-11-10T21:00:00Z","date":"2025-11-10","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ea60ec6f70b74ee79a96f66f9235afd3/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Transformer Oil Testing Services","agency":{"office":{"code":"899035","name":"PRINCETON LAB - DOE CONTRACTOR"},"subtier":{"code":"8900","name":"ENERGY, DEPARTMENT OF"},"department":{"code":"089","name":"ENERGY, DEPARTMENT OF"},"office_address":{"zip":"08540","city":"Princeton","state":"NJ","country":"USA"},"organization_id":"500047668","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-25","archive_type":"auto15"},"history":[{"index":3,"title":"Transformer Oil Testing Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-29T20:46:17.198Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ea60ec6f70b74ee79a96f66f9235afd3","solicitation_number":"SS-260020346"}],"contacts":[{"name":"Jimmy Russell","role":"primary","email":"jrussell@pppl.gov","phone":"6092433963"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"ea60ec6f70b74ee79a96f66f9235afd3","set_aside":{"code":"LAS","label":"Local Area Set-Aside (FAR 26.2)"},"lineage_id":"ea60ec6f70b74ee79a96f66f9235afd3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T03:32:13.377764240Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"3bd2f34b5d50badc958d1add5a3fed5297d6f74d8f84550f2c3eb9b770b16493","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-24T03:32:13.377764240Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"<p>The Princeton Plasma Physics Laboratory is searching for a qulaified contractor to perform the following services</p>\n\n<p>Subcontractor shall perform the following tasks and provide associated documentation.<br />\n5.1.1 Provide experienced personnel to inspect transformers and take required samples from oil<br />\nfilled transformers at PPPL at a mutually agreed upon time. All sampling containers and<br />\ntransport to subcontractors&rsquo; analyses facilities shall be provided by the subcontractor and<br />\ninclude in the pricing schedule.<br />\n5.1.2 Perform appropriate analyses of oil samples in subcontractor&rsquo;s laboratory. Most samples will<br />\nbe mineral oil. Silicone and bio-based oils will be identified in the sampling plan (if part of<br />\nroutine analyses) or on individual samples. Transformers requiring these analyses will be<br />\nidentified by the PTR. Subcontractor may use alternate ASTM methods to those called out in<br />\nthe SOW.<br />\n1. Oil Screen Analyses shall include the following.<br />\nAnalysis ASTM Standard<br />\na. Neutralization Number ASTM D 974<br />\nb. Interfacial Tension (IFT) ASTM D 971<br />\nc. Relative Density (Specific Gravity) ASTM D 1298<br />\nd. Color ASTM D 1500<br />\nPWR-SOW-056, Rev 2 PAGE 3 of 7<br />\ne. Visual Examination ASTM D 1524<br />\nf. Dielectric Breakdown Voltage ASTM D 877<br />\n2. Moisture in Oil<br />\nAnalysis ASTM Standard<br />\na. Moisture in Oil ASTM D 1533<br />\n3. Dissolved Gas Analysis<br />\nAnalysis ASTM Standard<br />\na. Dissolved Gas Sampling ASTM D 3613<br />\nb. Analysis by Gas Chromatography ASTM D 3612<br />\n4. Discretionary Analyses<br />\nSubcontractor shall also offer other analyses on a sample by sample basis, including the<br />\nfollowing.<br />\nAnalysis ASTM Standard<br />\na. Oxidation Inhibitor ASTM D 2668<br />\nb. Liquid Power Factor ASTM D 924<br />\nc. Furan Content ASTM D 5837<br />\nd. Metals in Oil ASTM D 3635<br />\n5.1.3 Subcontractor may properly dispose of sample remains 6 months after analysis.</p>","text":"The Princeton Plasma Physics Laboratory is searching for a qulaified contractor to perform the following services\n\nSubcontractor shall perform the following tasks and provide associated documentation.\n\n5.1.1 Provide experienced personnel to inspect transformers and take required samples from oil\n\nfilled transformers at PPPL at a mutually agreed upon time. All sampling containers and\n\ntransport to subcontractors’ analyses facilities shall be provided by the subcontractor and\n\ninclude in the pricing schedule.\n\n5.1.2 Perform appropriate analyses of oil samples in subcontractor’s laboratory. Most samples will\n\nbe mineral oil. Silicone and bio-based oils will be identified in the sampling plan (if part of\n\nroutine analyses) or on individual samples. Transformers requiring these analyses will be\n\nidentified by the PTR. Subcontractor may use alternate ASTM methods to those called out in\n\nthe SOW.\n\n1. Oil Screen Analyses shall include the following.\n\nAnalysis ASTM Standard\n\na. Neutralization Number ASTM D 974\n\nb. Interfacial Tension (IFT) ASTM D 971\n\nc. Relative Density (Specific Gravity) ASTM D 1298\n\nd. Color ASTM D 1500\n\nPWR-SOW-056, Rev 2 PAGE 3 of 7\n\ne. Visual Examination ASTM D 1524\n\nf. Dielectric Breakdown Voltage ASTM D 877\n\n2. Moisture in Oil\n\nAnalysis ASTM Standard\n\na. Moisture in Oil ASTM D 1533\n\n3. Dissolved Gas Analysis\n\nAnalysis ASTM Standard\n\na. Dissolved Gas Sampling ASTM D 3613\n\nb. Analysis by Gas Chromatography ASTM D 3612\n\n4. Discretionary Analyses\n\nSubcontractor shall also offer other analyses on a sample by sample basis, including the\n\nfollowing.\n\nAnalysis ASTM Standard\n\na. Oxidation Inhibitor ASTM D 2668\n\nb. Liquid Power Factor ASTM D 924\n\nc. Furan Content ASTM D 5837\n\nd. Metals in Oil ASTM D 3635\n\n5.1.3 Subcontractor may properly dispose of sample remains 6 months after analysis.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"SS-260020346","place_of_performance":{"zip":"08543","city":{"code":"60900","name":"Princeton"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H291"}],"due_at":"2025-11-10T21:00:00Z","due_date":"2025-11-10","closes_at":"2025-11-10T21:00:00Z","awardable":true,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899035","office_name":"PRINCETON LAB - DOE CONTRACTOR","state":"NJ","county":"34021","county_name":"Mercer County","city":"3460900","city_name":"Princeton","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-24T03:56:54.139438Z","principal_notice_id":"ea60ec6f70b74ee79a96f66f9235afd3","description":{"text":"The Princeton Plasma Physics Laboratory is searching for a qulaified contractor to perform the following services\n\nSubcontractor shall perform the following tasks and provide associated documentation.\n\n5.1.1 Provide experienced personnel to inspect transformers and take required samples from oil\n\nfilled transformers at PPPL at a mutually agreed upon time. All sampling containers and\n\ntransport to subcontractors’ analyses facilities shall be provided by the subcontractor and\n\ninclude in the pricing schedule.\n\n5.1.2 Perform appropriate analyses of oil samples in subcontractor’s laboratory. Most samples will\n\nbe mineral oil. Silicone and bio-based oils will be identified in the sampling plan (if part of\n\nroutine analyses) or on individual samples. Transformers requiring these analyses will be\n\nidentified by the PTR. Subcontractor may use alternate ASTM methods to those called out in\n\nthe SOW.\n\n1. Oil Screen Analyses shall include the following.\n\nAnalysis ASTM Standard\n\na. Neutralization Number ASTM D 974\n\nb. Interfacial Tension (IFT) ASTM D 971\n\nc. Relative Density (Specific Gravity) ASTM D 1298\n\nd. Color ASTM D 1500\n\nPWR-SOW-056, Rev 2 PAGE 3 of 7\n\ne. Visual Examination ASTM D 1524\n\nf. Dielectric Breakdown Voltage ASTM D 877\n\n2. Moisture in Oil\n\nAnalysis ASTM Standard\n\na. Moisture in Oil ASTM D 1533\n\n3. Dissolved Gas Analysis\n\nAnalysis ASTM Standard\n\na. Dissolved Gas Sampling ASTM D 3613\n\nb. Analysis by Gas Chromatography ASTM D 3612\n\n4. Discretionary Analyses\n\nSubcontractor shall also offer other analyses on a sample by sample basis, including the\n\nfollowing.\n\nAnalysis ASTM Standard\n\na. Oxidation Inhibitor ASTM D 2668\n\nb. Liquid Power Factor ASTM D 924\n\nc. Furan Content ASTM D 5837\n\nd. Metals in Oil ASTM D 3635\n\n5.1.3 Subcontractor may properly dispose of sample remains 6 months after analysis.","html":"<p>The Princeton Plasma Physics Laboratory is searching for a qulaified contractor to perform the following services</p>\n\n<p>Subcontractor shall perform the following tasks and provide associated documentation.<br />\n5.1.1 Provide experienced personnel to inspect transformers and take required samples from oil<br />\nfilled transformers at PPPL at a mutually agreed upon time. All sampling containers and<br />\ntransport to subcontractors&rsquo; analyses facilities shall be provided by the subcontractor and<br />\ninclude in the pricing schedule.<br />\n5.1.2 Perform appropriate analyses of oil samples in subcontractor&rsquo;s laboratory. Most samples will<br />\nbe mineral oil. Silicone and bio-based oils will be identified in the sampling plan (if part of<br />\nroutine analyses) or on individual samples. Transformers requiring these analyses will be<br />\nidentified by the PTR. Subcontractor may use alternate ASTM methods to those called out in<br />\nthe SOW.<br />\n1. Oil Screen Analyses shall include the following.<br />\nAnalysis ASTM Standard<br />\na. Neutralization Number ASTM D 974<br />\nb. Interfacial Tension (IFT) ASTM D 971<br />\nc. Relative Density (Specific Gravity) ASTM D 1298<br />\nd. Color ASTM D 1500<br />\nPWR-SOW-056, Rev 2 PAGE 3 of 7<br />\ne. Visual Examination ASTM D 1524<br />\nf. Dielectric Breakdown Voltage ASTM D 877<br />\n2. Moisture in Oil<br />\nAnalysis ASTM Standard<br />\na. Moisture in Oil ASTM D 1533<br />\n3. Dissolved Gas Analysis<br />\nAnalysis ASTM Standard<br />\na. Dissolved Gas Sampling ASTM D 3613<br />\nb. Analysis by Gas Chromatography ASTM D 3612<br />\n4. Discretionary Analyses<br />\nSubcontractor shall also offer other analyses on a sample by sample basis, including the<br />\nfollowing.<br />\nAnalysis ASTM Standard<br />\na. Oxidation Inhibitor ASTM D 2668<br />\nb. Liquid Power Factor ASTM D 924<br />\nc. Furan Content ASTM D 5837<br />\nd. Metals in Oil ASTM D 3635<br />\n5.1.3 Subcontractor may properly dispose of sample remains 6 months after analysis.</p>","origin":"detail"},"contacts":[{"name":"Jimmy Russell","role":"primary","email":"jrussell@pppl.gov","phone":"6092433963"}],"place_of_performance":{"zip":"08543","city":{"code":"60900","name":"Princeton"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"08540","city":"Princeton","state":"NJ","country":"USA"},"naics_codes":["541380"],"award":null,"attachments":[{"resource_id":"7a1030a9d9854fe48cfdbef6e76354ee","name":"TransSample-C-FAC-SOW-056-R0 (1) (1) (3).pdf","kind":"file","mime_type":".pdf","size_bytes":182870,"posted_at":"2025-10-29T20:46:17.198Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7a1030a9d9854fe48cfdbef6e76354ee/download","mirrored":false}],"awards":[],"related":[{"key":"RFP27005JR","latest_notice_id":"91e1a83848304f2d84cfe6e95588d9e6","title":"RF Roof Replacement Project","solicitation_number":"RFP27-005JR","notice_type":"k","first_type":"k","first_posted":"2026-10-30","last_posted":"2026-11-09","notices":6,"due_at":"2026-12-10T21:00:00Z","due_date":"2026-12-10","closes_at":"2026-12-10T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899035","office_name":"PRINCETON LAB - DOE CONTRACTOR","naics":"238160","psc":"Y1EZ","set_aside":null,"state":"NJ","county":"34021","county_name":"Mercer County","city":"3460900","city_name":"Princeton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"}],"similar_open":[{"key":"67100PR270000313","latest_notice_id":"30433fae4c174d0684236ca816bb2b22","title":"Testing of USCG TRACEN Cape May Potable Water","solicitation_number":"67100PR270000313","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL70","office_name":"ATC MOBILE","naics":"541380","psc":"F103","set_aside":"SBA","state":"NJ","county":"34009","county_name":"Cape May County","city":"3410270","city_name":"Cape May","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927AP1027","latest_notice_id":"6960cc2ab4be4d428eac6e0f6ece061f","title":"APT Generator Switchgear Testing – Alvin C. York VA Medical Center","solicitation_number":"36C249-27-AP-1027","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"541380","psc":"H261","set_aside":null,"state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":34,"indexable":false}