{"canonical":"https://sealedbidder.com/opportunities/spmym325q3109","key":"SPMYM325Q3109","url":"https://sealedbidder.com/opportunities/spmym325q3109","title":"IDIQ for Ventilation Ducting - 11 various items","solicitation_number":"SPMYM325Q3109","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-01-17T20:00:00Z","first_posted":"2025-01-08","last_posted":"2025-01-08","department":"DEPT OF DEFENSE","subagency":"DEFENSE LOGISTICS AGENCY","office":"DLA MARITIME - PORTSMOUTH","naics":"326220","psc":"4720","set_aside":null,"place_state":"ME","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"23031","place_county_name":"York County","place_city":"2337235","place_city_name":"Kittery","winner":null,"award_amount":null,"publications":[{"notice_id":"ae0286daec404147a10a727c7c99fcdc","title":"IDIQ for Ventilation Ducting - 11 various items","solicitation_number":"SPMYM325Q3109","notice_type":"r","base_type":"r","posted":"2025-01-08","posted_at":"2025-01-08T21:09:50.572Z","due_at":"2025-01-17T20:00:00Z","due_date":"2025-01-17","cancelled":false,"archived":true,"archive_date":"2025-02-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ae0286daec404147a10a727c7c99fcdc/view","enriched":true,"history":[{"index":6,"title":"IDIQ for Ventilation Ducting - 11 various items","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-02T14:30:12.777Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"004ddc3d052f48aa8ce9c75bbca98c18","solicitation_number":"SPMYM326Q3101","related_opportunity_id":"ae0286daec404147a10a727c7c99fcdc"},{"index":3,"title":"IDIQ for Ventilation Ducting - 11 various items","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-08T21:09:50.572Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ae0286daec404147a10a727c7c99fcdc","solicitation_number":"SPMYM325Q3109"}]}],"latest_notice_id":"ae0286daec404147a10a727c7c99fcdc","first_type":"r","notices":[{"dates":{"posted":"2025-01-08","posted_at":"2025-01-08T21:09:50.572Z","created_at":"2025-01-08T21:04:25.370Z","modified_at":"2025-02-01T05:04:58.874Z","response_deadline":{"raw":"2025-01-17T15:00:00-05:00","utc":"2025-01-17T20:00:00Z","date":"2025-01-17","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ae0286daec404147a10a727c7c99fcdc/view"},"naics":{"codes":["326220"],"primary":"326220"},"title":"IDIQ for Ventilation Ducting - 11 various items","agency":{"office":{"code":"SPMYM3","name":"DLA MARITIME - PORTSMOUTH"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"03801-5000","city":"PORTSMOUTH","state":"NH","country":"USA"},"organization_id":"500032827","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-01","archive_type":"auto15"},"history":[{"index":6,"title":"IDIQ for Ventilation Ducting - 11 various items","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-02T14:30:12.777Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"004ddc3d052f48aa8ce9c75bbca98c18","solicitation_number":"SPMYM326Q3101","related_opportunity_id":"ae0286daec404147a10a727c7c99fcdc"},{"index":3,"title":"IDIQ for Ventilation Ducting - 11 various items","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-08T21:09:50.572Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ae0286daec404147a10a727c7c99fcdc","solicitation_number":"SPMYM325Q3109"}],"contacts":[{"name":"Emily Kritzman","role":"primary","email":"emily.kritzman@dla.mil"},{"name":"DLA-KME EMAIL BOX","role":"secondary","email":"DLA-KME-QUOTATIONS@DLA.MIL"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"ae0286daec404147a10a727c7c99fcdc","lineage_id":"ae0286daec404147a10a727c7c99fcdc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-26T02:58:29.788832738Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"3706a4dc1288b2ad9d76c9e67deee12d292e371fd9cb9bdf24abbc09aca24bee","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-26T02:58:29.788832738Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><br />\nThis notice is a Sources Sought Notice for a requirement at the Portsmouth Naval Shipyard. &nbsp;This notice is being issued to determine interested vendors and to help establish an appropriate set-aside if applicable. &nbsp;Please note that this is NOT a Request For Quotation (RFQ) and submission of your company&rsquo;s interest may not result in your company being considered for a set-aside or bidders list for the RFQ. This sources sought notice is for market research purposes only. &nbsp;Vendors that are able to provide this material need to provide the following in an e-mail to Emily.Kritzman@dla.mil.&nbsp;</p>\n\n<p>RESPONSES MUST INCLUDE:&nbsp;<br />\n1. Vendor&rsquo;s name, address, phone number, fax number, and e-mail address.<br />\n2. Vendor&rsquo;s Cage Code (SAM).<br />\n3. Vendor&rsquo;s size status (SB, SDVOSB, 8a, HUBZone, WOSB, etc.,).<br />\n4. If the vendor is not the actual manufacturer, the actual manufacturer&rsquo;s name, Cage Code, and size status is required.<br />\n5. Statement explaining capabilities, including, but not limited to, specific Model Numbers, with detailed literature and manufacturers specifications.&nbsp;</p>\n\n<p>Information provided in response to this notice must include sufficient technical information for an evaluation to be conducted, to determine if a source is capable. Responses that do not include technical information may be determined unresponsive and/or not capable.&nbsp;</p>\n\n<p><br />\n***<br />\nThe Portsmouth Naval Shipyard interested in issuing a 5-year IDIQ contract, and is seeking sources capable of providing the following:&nbsp;</p>\n\n<p>SCOPE</p>\n\n<p>1. This requirement is for a five (5) year IDIQ (Indefinite Delivery Indefinite Quantity) Contract, to consist of one (1) base year, with four (4) option years.&nbsp;</p>\n\n<p>2. The Period of Performance (POP) is ONE YEAR from the date of award, with FOUR OPTION YEARS. For estimating purposes only, the POP is currently estimated to begin in July or August.&nbsp;</p>\n\n<p>3. The IDIQ material is as follows:</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0001: Ventilation Ducting, TR-FR 4&quot; BLACK/BLUE, or equal, in accordance with (iaw) the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0002: Ventilation Ducting, TR-FR 4&quot; BLACK/ORANGE, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0003: Ventilation Ducting, TR-FR 4&quot; BLACK/GREEN, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0004: Ventilation Ducting, TR-FR 6&quot; BLACK/BLUE, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0005: Ventilation Ducting, TR-FR 8&quot; BLACK/BLUE, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0006: Ventilation Ducting, TR-FR 8&quot; BLACK/GREEN, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0007: Ventilation Ducting, R-3 BLUE 14&quot;, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0008: Ventilation Ducting, 4&quot; ALUMINUM, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0009: Ventilation Ducting, 6&quot; ALUMINUM, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0010: Ventilation Ducting, 8&quot; ALUMINUM, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0011: Ventilation Ducting, 20&quot; INSULATED FLEX DUCT, iaw the Specifications.<br />\nSee Attached Specifications for details.&nbsp;</p>\n\n<p><br />\n4. The IDIQ constraints are as follows:&nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0001: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0002: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0003: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0004: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0005: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0006: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0007: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0008: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 100 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0009: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0010: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 200 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0011: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1001: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1002: The MIN is 20 lengths, and the MAX is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1003: The MIN is 20 lengths, and the MAX is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1004: The MIN is 24 lengths, and the MAX is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1005: The MIN is 24 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1006: The MIN is 24 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1007: The MIN is 10 lengths, and the MAX is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1008: The MIN is 25 lengths, and the MAX is 100 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1009: The MIN is 10 lengths, and the MAX is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1010: The MIN is 25 lengths, and the MAX is 200 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1011: The MIN is 25 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2001: The MIN is 20 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2002: The MIN is 20 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2003: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2004: The MIN is 24 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2005: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2006: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2007: The MIN is 10 lengths, and the MAX is 80 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2008: The MIN is 25 lengths, and the MAX is 150 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2009: The MIN is 10 lengths, and the MAX is 75 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2010: The MIN is 25 lengths, and the MAX is 250 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2011: The MIN is 25 lengths, and the MAX is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3001: The MIN is 20 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3002: The MIN is 20 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3003: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3004: The MIN is 24 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3005: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3006: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3007: The MIN is 10 lengths, and the MAX is 80 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3008: The MIN is 25 lengths, and the MAX is 150 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3009: The MIN is 10 lengths, and the MAX is 75 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3010: The MIN is 25 lengths, and the MAX is 250 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3011: The MIN is 25 lengths, and the MAX is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4001: The MIN is 20 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4002: The MIN is 20 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4003: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4004: The MIN is 24 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4005: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4006: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4007: The MIN is 10 lengths, and the MAX is 80 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4008: The MIN is 25 lengths, and the MAX is 100 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4009: The MIN is 10 lengths, and the MAX is 75 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4010: The MIN is 25 lengths, and the MAX is 250 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4011: The MIN is 25 lengths, and the MAX is 500 lengths.&nbsp;</p>\n\n<p><br />\n5. The delivery location is:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Portsmouth Naval Shipyard, Kittery, ME.&nbsp;</p>\n\n<p>6. Notes: Only the minimum annual quantity is guaranteed during any one-year period. There is no specific minimum quantity for individual orders after the annual minimum is met. If there is a minimum order quantity for any material, please provide that information in your response.&nbsp;</p>\n\n<p><br />\n***</p>\n\n<p>This requirement may be evaluated for multiple award.&nbsp;</p>\n\n<p>***</p>\n\n<p>Vendors who would not be providing ducting from one of the sources identified on the Approved Vendors List, below, would be required (NOT AT THIS TIME) to submit a 1&rsquo; sample at no cost to the Government of each type of ducting to show that their product meets the specifications. Samples will not be returned after testing.&nbsp;</p>\n\n<p>Approved Vendors List:</p>\n\n<p>New England Rubber<br />\n480 Neponset ST Bldg 4<br />\nCanton, MA 02021-1971&nbsp;<br />\nCAGE: 4S629</p>\n\n<p>PRC Industrial Supply<br />\n21 W Commercial Street&nbsp;<br />\nPortland Maine 04101&nbsp;<br />\nCAGE: 6U557</p>\n\n<p>Industrial Supply/McGill Hose and Coupling<br />\n35 Industrial Parkway<br />\nWoburn, MA 01801<br />\nCAGE: 7L974</p>\n\n<p>Amesbury Industrial Supply<br />\n24 High Street<br />\nAmesbury, MA 01913-2422&nbsp;<br />\nCAGE: 1FF43</p>\n\n<p>Omni Services<br />\n15 Banfield Road Unit 3<br />\nPortsmouth, NH 03801-5607<br />\nCAGE: 3QQK1</p>\n\n<p>Tru-Flex Metal Hose LLC<br />\n2391 S State Road<br />\nWest Lebanon, IN 47991-0247<br />\nCAGE: 331F6</p>\n\n<p>***</p>\n\n<p><br />\nTHERE IS NO ANTICIPATED DATE FOR A SOLICITATION AT THIS TIME.&nbsp;</p>\n\n<p><br />\n***End of Sources Sought Notice***</p>","text":"This notice is a Sources Sought Notice for a requirement at the Portsmouth Naval Shipyard. This notice is being issued to determine interested vendors and to help establish an appropriate set-aside if applicable. Please note that this is NOT a Request For Quotation (RFQ) and submission of your company’s interest may not result in your company being considered for a set-aside or bidders list for the RFQ. This sources sought notice is for market research purposes only. Vendors that are able to provide this material need to provide the following in an e-mail to Emily.Kritzman@dla.mil.\n\nRESPONSES MUST INCLUDE:\n\n1. Vendor’s name, address, phone number, fax number, and e-mail address.\n\n2. Vendor’s Cage Code (SAM).\n\n3. Vendor’s size status (SB, SDVOSB, 8a, HUBZone, WOSB, etc.,).\n\n4. If the vendor is not the actual manufacturer, the actual manufacturer’s name, Cage Code, and size status is required.\n\n5. Statement explaining capabilities, including, but not limited to, specific Model Numbers, with detailed literature and manufacturers specifications.\n\nInformation provided in response to this notice must include sufficient technical information for an evaluation to be conducted, to determine if a source is capable. Responses that do not include technical information may be determined unresponsive and/or not capable.\n\n***\n\nThe Portsmouth Naval Shipyard interested in issuing a 5-year IDIQ contract, and is seeking sources capable of providing the following:\n\nSCOPE\n\n1. This requirement is for a five (5) year IDIQ (Indefinite Delivery Indefinite Quantity) Contract, to consist of one (1) base year, with four (4) option years.\n\n2. The Period of Performance (POP) is ONE YEAR from the date of award, with FOUR OPTION YEARS. For estimating purposes only, the POP is currently estimated to begin in July or August.\n\n3. The IDIQ material is as follows:\n\nItem 0001: Ventilation Ducting, TR-FR 4\" BLACK/BLUE, or equal, in accordance with (iaw) the Specifications.\n\nItem 0002: Ventilation Ducting, TR-FR 4\" BLACK/ORANGE, or equal, iaw the Specifications.\n\nItem 0003: Ventilation Ducting, TR-FR 4\" BLACK/GREEN, or equal, iaw the Specifications.\n\nItem 0004: Ventilation Ducting, TR-FR 6\" BLACK/BLUE, or equal, iaw the Specifications.\n\nItem 0005: Ventilation Ducting, TR-FR 8\" BLACK/BLUE, or equal, iaw the Specifications.\n\nItem 0006: Ventilation Ducting, TR-FR 8\" BLACK/GREEN, or equal, iaw the Specifications.\n\nItem 0007: Ventilation Ducting, R-3 BLUE 14\", or equal, iaw the Specifications.\n\nItem 0008: Ventilation Ducting, 4\" ALUMINUM, iaw the Specifications.\n\nItem 0009: Ventilation Ducting, 6\" ALUMINUM, iaw the Specifications.\n\nItem 0010: Ventilation Ducting, 8\" ALUMINUM, iaw the Specifications.\n\nItem 0011: Ventilation Ducting, 20\" INSULATED FLEX DUCT, iaw the Specifications.\n\nSee Attached Specifications for details.\n\n4. The IDIQ constraints are as follows:\n\nCLIN 0001: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 600 lengths.\n\nCLIN 0002: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 300 lengths.\n\nCLIN 0003: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 500 lengths.\n\nCLIN 0004: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 300 lengths.\n\nCLIN 0005: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.\n\nCLIN 0006: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.\n\nCLIN 0007: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.\n\nCLIN 0008: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 100 lengths.\n\nCLIN 0009: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.\n\nCLIN 0010: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 200 lengths.\n\nCLIN 0011: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 400 lengths.\n\nOption CLIN 1001: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 1002: The MIN is 20 lengths, and the MAX is 300 lengths.\n\nOption CLIN 1003: The MIN is 20 lengths, and the MAX is 500 lengths.\n\nOption CLIN 1004: The MIN is 24 lengths, and the MAX is 300 lengths.\n\nOption CLIN 1005: The MIN is 24 lengths, and the MAX is 600 lengths.\n\nOption CLIN 1006: The MIN is 24 lengths, and the MAX is 600 lengths.\n\nOption CLIN 1007: The MIN is 10 lengths, and the MAX is 60 lengths.\n\nOption CLIN 1008: The MIN is 25 lengths, and the MAX is 100 lengths.\n\nOption CLIN 1009: The MIN is 10 lengths, and the MAX is 60 lengths.\n\nOption CLIN 1010: The MIN is 25 lengths, and the MAX is 200 lengths.\n\nOption CLIN 1011: The MIN is 25 lengths, and the MAX is 400 lengths.\n\nOption CLIN 2001: The MIN is 20 lengths, and the MAX is 750 lengths.\n\nOption CLIN 2002: The MIN is 20 lengths, and the MAX is 400 lengths.\n\nOption CLIN 2003: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 2004: The MIN is 24 lengths, and the MAX is 400 lengths.\n\nOption CLIN 2005: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 2006: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 2007: The MIN is 10 lengths, and the MAX is 80 lengths.\n\nOption CLIN 2008: The MIN is 25 lengths, and the MAX is 150 lengths.\n\nOption CLIN 2009: The MIN is 10 lengths, and the MAX is 75 lengths.\n\nOption CLIN 2010: The MIN is 25 lengths, and the MAX is 250 lengths.\n\nOption CLIN 2011: The MIN is 25 lengths, and the MAX is 500 lengths.\n\nOption CLIN 3001: The MIN is 20 lengths, and the MAX is 750 lengths.\n\nOption CLIN 3002: The MIN is 20 lengths, and the MAX is 400 lengths.\n\nOption CLIN 3003: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 3004: The MIN is 24 lengths, and the MAX is 400 lengths.\n\nOption CLIN 3005: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 3006: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 3007: The MIN is 10 lengths, and the MAX is 80 lengths.\n\nOption CLIN 3008: The MIN is 25 lengths, and the MAX is 150 lengths.\n\nOption CLIN 3009: The MIN is 10 lengths, and the MAX is 75 lengths.\n\nOption CLIN 3010: The MIN is 25 lengths, and the MAX is 250 lengths.\n\nOption CLIN 3011: The MIN is 25 lengths, and the MAX is 500 lengths.\n\nOption CLIN 4001: The MIN is 20 lengths, and the MAX is 750 lengths.\n\nOption CLIN 4002: The MIN is 20 lengths, and the MAX is 400 lengths.\n\nOption CLIN 4003: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 4004: The MIN is 24 lengths, and the MAX is 400 lengths.\n\nOption CLIN 4005: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 4006: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 4007: The MIN is 10 lengths, and the MAX is 80 lengths.\n\nOption CLIN 4008: The MIN is 25 lengths, and the MAX is 100 lengths.\n\nOption CLIN 4009: The MIN is 10 lengths, and the MAX is 75 lengths.\n\nOption CLIN 4010: The MIN is 25 lengths, and the MAX is 250 lengths.\n\nOption CLIN 4011: The MIN is 25 lengths, and the MAX is 500 lengths.\n\n5. The delivery location is:\n\nPortsmouth Naval Shipyard, Kittery, ME.\n\n6. Notes: Only the minimum annual quantity is guaranteed during any one-year period. There is no specific minimum quantity for individual orders after the annual minimum is met. If there is a minimum order quantity for any material, please provide that information in your response.\n\n***\n\nThis requirement may be evaluated for multiple award.\n\n***\n\nVendors who would not be providing ducting from one of the sources identified on the Approved Vendors List, below, would be required (NOT AT THIS TIME) to submit a 1’ sample at no cost to the Government of each type of ducting to show that their product meets the specifications. Samples will not be returned after testing.\n\nApproved Vendors List:\n\nNew England Rubber\n\n480 Neponset ST Bldg 4\n\nCanton, MA 02021-1971\n\nCAGE: 4S629\n\nPRC Industrial Supply\n\n21 W Commercial Street\n\nPortland Maine 04101\n\nCAGE: 6U557\n\nIndustrial Supply/McGill Hose and Coupling\n\n35 Industrial Parkway\n\nWoburn, MA 01801\n\nCAGE: 7L974\n\nAmesbury Industrial Supply\n\n24 High Street\n\nAmesbury, MA 01913-2422\n\nCAGE: 1FF43\n\nOmni Services\n\n15 Banfield Road Unit 3\n\nPortsmouth, NH 03801-5607\n\nCAGE: 3QQK1\n\nTru-Flex Metal Hose LLC\n\n2391 S State Road\n\nWest Lebanon, IN 47991-0247\n\nCAGE: 331F6\n\n***\n\nTHERE IS NO ANTICIPATED DATE FOR A SOLICITATION AT THIS TIME.\n\n***End of Sources Sought Notice***","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"SPMYM325Q3109","place_of_performance":{"zip":"03904","city":{"code":"37270","name":"Kittery"},"state":{"code":"ME","name":"Maine"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4720"}],"due_at":"2025-01-17T20:00:00Z","due_date":"2025-01-17","closes_at":"2025-01-17T20:00:00Z","awardable":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM3","office_name":"DLA MARITIME - PORTSMOUTH","state":"ME","county":"23031","county_name":"York County","city":"2337235","city_name":"Kittery","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-26T03:35:12.773493Z","principal_notice_id":"ae0286daec404147a10a727c7c99fcdc","description":{"text":"This notice is a Sources Sought Notice for a requirement at the Portsmouth Naval Shipyard. This notice is being issued to determine interested vendors and to help establish an appropriate set-aside if applicable. Please note that this is NOT a Request For Quotation (RFQ) and submission of your company’s interest may not result in your company being considered for a set-aside or bidders list for the RFQ. This sources sought notice is for market research purposes only. Vendors that are able to provide this material need to provide the following in an e-mail to Emily.Kritzman@dla.mil.\n\nRESPONSES MUST INCLUDE:\n\n1. Vendor’s name, address, phone number, fax number, and e-mail address.\n\n2. Vendor’s Cage Code (SAM).\n\n3. Vendor’s size status (SB, SDVOSB, 8a, HUBZone, WOSB, etc.,).\n\n4. If the vendor is not the actual manufacturer, the actual manufacturer’s name, Cage Code, and size status is required.\n\n5. Statement explaining capabilities, including, but not limited to, specific Model Numbers, with detailed literature and manufacturers specifications.\n\nInformation provided in response to this notice must include sufficient technical information for an evaluation to be conducted, to determine if a source is capable. Responses that do not include technical information may be determined unresponsive and/or not capable.\n\n***\n\nThe Portsmouth Naval Shipyard interested in issuing a 5-year IDIQ contract, and is seeking sources capable of providing the following:\n\nSCOPE\n\n1. This requirement is for a five (5) year IDIQ (Indefinite Delivery Indefinite Quantity) Contract, to consist of one (1) base year, with four (4) option years.\n\n2. The Period of Performance (POP) is ONE YEAR from the date of award, with FOUR OPTION YEARS. For estimating purposes only, the POP is currently estimated to begin in July or August.\n\n3. The IDIQ material is as follows:\n\nItem 0001: Ventilation Ducting, TR-FR 4\" BLACK/BLUE, or equal, in accordance with (iaw) the Specifications.\n\nItem 0002: Ventilation Ducting, TR-FR 4\" BLACK/ORANGE, or equal, iaw the Specifications.\n\nItem 0003: Ventilation Ducting, TR-FR 4\" BLACK/GREEN, or equal, iaw the Specifications.\n\nItem 0004: Ventilation Ducting, TR-FR 6\" BLACK/BLUE, or equal, iaw the Specifications.\n\nItem 0005: Ventilation Ducting, TR-FR 8\" BLACK/BLUE, or equal, iaw the Specifications.\n\nItem 0006: Ventilation Ducting, TR-FR 8\" BLACK/GREEN, or equal, iaw the Specifications.\n\nItem 0007: Ventilation Ducting, R-3 BLUE 14\", or equal, iaw the Specifications.\n\nItem 0008: Ventilation Ducting, 4\" ALUMINUM, iaw the Specifications.\n\nItem 0009: Ventilation Ducting, 6\" ALUMINUM, iaw the Specifications.\n\nItem 0010: Ventilation Ducting, 8\" ALUMINUM, iaw the Specifications.\n\nItem 0011: Ventilation Ducting, 20\" INSULATED FLEX DUCT, iaw the Specifications.\n\nSee Attached Specifications for details.\n\n4. The IDIQ constraints are as follows:\n\nCLIN 0001: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 600 lengths.\n\nCLIN 0002: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 300 lengths.\n\nCLIN 0003: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 500 lengths.\n\nCLIN 0004: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 300 lengths.\n\nCLIN 0005: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.\n\nCLIN 0006: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.\n\nCLIN 0007: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.\n\nCLIN 0008: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 100 lengths.\n\nCLIN 0009: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.\n\nCLIN 0010: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 200 lengths.\n\nCLIN 0011: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 400 lengths.\n\nOption CLIN 1001: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 1002: The MIN is 20 lengths, and the MAX is 300 lengths.\n\nOption CLIN 1003: The MIN is 20 lengths, and the MAX is 500 lengths.\n\nOption CLIN 1004: The MIN is 24 lengths, and the MAX is 300 lengths.\n\nOption CLIN 1005: The MIN is 24 lengths, and the MAX is 600 lengths.\n\nOption CLIN 1006: The MIN is 24 lengths, and the MAX is 600 lengths.\n\nOption CLIN 1007: The MIN is 10 lengths, and the MAX is 60 lengths.\n\nOption CLIN 1008: The MIN is 25 lengths, and the MAX is 100 lengths.\n\nOption CLIN 1009: The MIN is 10 lengths, and the MAX is 60 lengths.\n\nOption CLIN 1010: The MIN is 25 lengths, and the MAX is 200 lengths.\n\nOption CLIN 1011: The MIN is 25 lengths, and the MAX is 400 lengths.\n\nOption CLIN 2001: The MIN is 20 lengths, and the MAX is 750 lengths.\n\nOption CLIN 2002: The MIN is 20 lengths, and the MAX is 400 lengths.\n\nOption CLIN 2003: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 2004: The MIN is 24 lengths, and the MAX is 400 lengths.\n\nOption CLIN 2005: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 2006: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 2007: The MIN is 10 lengths, and the MAX is 80 lengths.\n\nOption CLIN 2008: The MIN is 25 lengths, and the MAX is 150 lengths.\n\nOption CLIN 2009: The MIN is 10 lengths, and the MAX is 75 lengths.\n\nOption CLIN 2010: The MIN is 25 lengths, and the MAX is 250 lengths.\n\nOption CLIN 2011: The MIN is 25 lengths, and the MAX is 500 lengths.\n\nOption CLIN 3001: The MIN is 20 lengths, and the MAX is 750 lengths.\n\nOption CLIN 3002: The MIN is 20 lengths, and the MAX is 400 lengths.\n\nOption CLIN 3003: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 3004: The MIN is 24 lengths, and the MAX is 400 lengths.\n\nOption CLIN 3005: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 3006: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 3007: The MIN is 10 lengths, and the MAX is 80 lengths.\n\nOption CLIN 3008: The MIN is 25 lengths, and the MAX is 150 lengths.\n\nOption CLIN 3009: The MIN is 10 lengths, and the MAX is 75 lengths.\n\nOption CLIN 3010: The MIN is 25 lengths, and the MAX is 250 lengths.\n\nOption CLIN 3011: The MIN is 25 lengths, and the MAX is 500 lengths.\n\nOption CLIN 4001: The MIN is 20 lengths, and the MAX is 750 lengths.\n\nOption CLIN 4002: The MIN is 20 lengths, and the MAX is 400 lengths.\n\nOption CLIN 4003: The MIN is 20 lengths, and the MAX is 600 lengths.\n\nOption CLIN 4004: The MIN is 24 lengths, and the MAX is 400 lengths.\n\nOption CLIN 4005: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 4006: The MIN is 24 lengths, and the MAX is 750 lengths.\n\nOption CLIN 4007: The MIN is 10 lengths, and the MAX is 80 lengths.\n\nOption CLIN 4008: The MIN is 25 lengths, and the MAX is 100 lengths.\n\nOption CLIN 4009: The MIN is 10 lengths, and the MAX is 75 lengths.\n\nOption CLIN 4010: The MIN is 25 lengths, and the MAX is 250 lengths.\n\nOption CLIN 4011: The MIN is 25 lengths, and the MAX is 500 lengths.\n\n5. The delivery location is:\n\nPortsmouth Naval Shipyard, Kittery, ME.\n\n6. Notes: Only the minimum annual quantity is guaranteed during any one-year period. There is no specific minimum quantity for individual orders after the annual minimum is met. If there is a minimum order quantity for any material, please provide that information in your response.\n\n***\n\nThis requirement may be evaluated for multiple award.\n\n***\n\nVendors who would not be providing ducting from one of the sources identified on the Approved Vendors List, below, would be required (NOT AT THIS TIME) to submit a 1’ sample at no cost to the Government of each type of ducting to show that their product meets the specifications. Samples will not be returned after testing.\n\nApproved Vendors List:\n\nNew England Rubber\n\n480 Neponset ST Bldg 4\n\nCanton, MA 02021-1971\n\nCAGE: 4S629\n\nPRC Industrial Supply\n\n21 W Commercial Street\n\nPortland Maine 04101\n\nCAGE: 6U557\n\nIndustrial Supply/McGill Hose and Coupling\n\n35 Industrial Parkway\n\nWoburn, MA 01801\n\nCAGE: 7L974\n\nAmesbury Industrial Supply\n\n24 High Street\n\nAmesbury, MA 01913-2422\n\nCAGE: 1FF43\n\nOmni Services\n\n15 Banfield Road Unit 3\n\nPortsmouth, NH 03801-5607\n\nCAGE: 3QQK1\n\nTru-Flex Metal Hose LLC\n\n2391 S State Road\n\nWest Lebanon, IN 47991-0247\n\nCAGE: 331F6\n\n***\n\nTHERE IS NO ANTICIPATED DATE FOR A SOLICITATION AT THIS TIME.\n\n***End of Sources Sought Notice***","html":"<p><br />\nThis notice is a Sources Sought Notice for a requirement at the Portsmouth Naval Shipyard. &nbsp;This notice is being issued to determine interested vendors and to help establish an appropriate set-aside if applicable. &nbsp;Please note that this is NOT a Request For Quotation (RFQ) and submission of your company&rsquo;s interest may not result in your company being considered for a set-aside or bidders list for the RFQ. This sources sought notice is for market research purposes only. &nbsp;Vendors that are able to provide this material need to provide the following in an e-mail to Emily.Kritzman@dla.mil.&nbsp;</p>\n\n<p>RESPONSES MUST INCLUDE:&nbsp;<br />\n1. Vendor&rsquo;s name, address, phone number, fax number, and e-mail address.<br />\n2. Vendor&rsquo;s Cage Code (SAM).<br />\n3. Vendor&rsquo;s size status (SB, SDVOSB, 8a, HUBZone, WOSB, etc.,).<br />\n4. If the vendor is not the actual manufacturer, the actual manufacturer&rsquo;s name, Cage Code, and size status is required.<br />\n5. Statement explaining capabilities, including, but not limited to, specific Model Numbers, with detailed literature and manufacturers specifications.&nbsp;</p>\n\n<p>Information provided in response to this notice must include sufficient technical information for an evaluation to be conducted, to determine if a source is capable. Responses that do not include technical information may be determined unresponsive and/or not capable.&nbsp;</p>\n\n<p><br />\n***<br />\nThe Portsmouth Naval Shipyard interested in issuing a 5-year IDIQ contract, and is seeking sources capable of providing the following:&nbsp;</p>\n\n<p>SCOPE</p>\n\n<p>1. This requirement is for a five (5) year IDIQ (Indefinite Delivery Indefinite Quantity) Contract, to consist of one (1) base year, with four (4) option years.&nbsp;</p>\n\n<p>2. The Period of Performance (POP) is ONE YEAR from the date of award, with FOUR OPTION YEARS. For estimating purposes only, the POP is currently estimated to begin in July or August.&nbsp;</p>\n\n<p>3. The IDIQ material is as follows:</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0001: Ventilation Ducting, TR-FR 4&quot; BLACK/BLUE, or equal, in accordance with (iaw) the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0002: Ventilation Ducting, TR-FR 4&quot; BLACK/ORANGE, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0003: Ventilation Ducting, TR-FR 4&quot; BLACK/GREEN, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0004: Ventilation Ducting, TR-FR 6&quot; BLACK/BLUE, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0005: Ventilation Ducting, TR-FR 8&quot; BLACK/BLUE, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0006: Ventilation Ducting, TR-FR 8&quot; BLACK/GREEN, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0007: Ventilation Ducting, R-3 BLUE 14&quot;, or equal, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0008: Ventilation Ducting, 4&quot; ALUMINUM, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0009: Ventilation Ducting, 6&quot; ALUMINUM, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0010: Ventilation Ducting, 8&quot; ALUMINUM, iaw the Specifications.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Item 0011: Ventilation Ducting, 20&quot; INSULATED FLEX DUCT, iaw the Specifications.<br />\nSee Attached Specifications for details.&nbsp;</p>\n\n<p><br />\n4. The IDIQ constraints are as follows:&nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0001: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0002: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0003: The minimum annual quantity (MIN) is 20 lengths, and the maximum annual quantity (MAX) is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0004: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0005: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0006: The minimum annual quantity (MIN) is 24 lengths, and the maximum annual quantity (MAX) is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0007: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0008: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 100 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0009: The minimum annual quantity (MIN) is 10 lengths, and the maximum annual quantity (MAX) is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0010: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 200 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CLIN 0011: The minimum annual quantity (MIN) is 25 lengths, and the maximum annual quantity (MAX) is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1001: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1002: The MIN is 20 lengths, and the MAX is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1003: The MIN is 20 lengths, and the MAX is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1004: The MIN is 24 lengths, and the MAX is 300 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1005: The MIN is 24 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1006: The MIN is 24 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1007: The MIN is 10 lengths, and the MAX is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1008: The MIN is 25 lengths, and the MAX is 100 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1009: The MIN is 10 lengths, and the MAX is 60 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1010: The MIN is 25 lengths, and the MAX is 200 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 1011: The MIN is 25 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2001: The MIN is 20 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2002: The MIN is 20 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2003: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2004: The MIN is 24 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2005: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2006: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2007: The MIN is 10 lengths, and the MAX is 80 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2008: The MIN is 25 lengths, and the MAX is 150 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2009: The MIN is 10 lengths, and the MAX is 75 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2010: The MIN is 25 lengths, and the MAX is 250 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 2011: The MIN is 25 lengths, and the MAX is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3001: The MIN is 20 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3002: The MIN is 20 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3003: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3004: The MIN is 24 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3005: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3006: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3007: The MIN is 10 lengths, and the MAX is 80 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3008: The MIN is 25 lengths, and the MAX is 150 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3009: The MIN is 10 lengths, and the MAX is 75 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3010: The MIN is 25 lengths, and the MAX is 250 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 3011: The MIN is 25 lengths, and the MAX is 500 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4001: The MIN is 20 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4002: The MIN is 20 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4003: The MIN is 20 lengths, and the MAX is 600 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4004: The MIN is 24 lengths, and the MAX is 400 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4005: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4006: The MIN is 24 lengths, and the MAX is 750 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4007: The MIN is 10 lengths, and the MAX is 80 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4008: The MIN is 25 lengths, and the MAX is 100 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4009: The MIN is 10 lengths, and the MAX is 75 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4010: The MIN is 25 lengths, and the MAX is 250 lengths.&nbsp;<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Option CLIN 4011: The MIN is 25 lengths, and the MAX is 500 lengths.&nbsp;</p>\n\n<p><br />\n5. The delivery location is:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Portsmouth Naval Shipyard, Kittery, ME.&nbsp;</p>\n\n<p>6. Notes: Only the minimum annual quantity is guaranteed during any one-year period. There is no specific minimum quantity for individual orders after the annual minimum is met. If there is a minimum order quantity for any material, please provide that information in your response.&nbsp;</p>\n\n<p><br />\n***</p>\n\n<p>This requirement may be evaluated for multiple award.&nbsp;</p>\n\n<p>***</p>\n\n<p>Vendors who would not be providing ducting from one of the sources identified on the Approved Vendors List, below, would be required (NOT AT THIS TIME) to submit a 1&rsquo; sample at no cost to the Government of each type of ducting to show that their product meets the specifications. Samples will not be returned after testing.&nbsp;</p>\n\n<p>Approved Vendors List:</p>\n\n<p>New England Rubber<br />\n480 Neponset ST Bldg 4<br />\nCanton, MA 02021-1971&nbsp;<br />\nCAGE: 4S629</p>\n\n<p>PRC Industrial Supply<br />\n21 W Commercial Street&nbsp;<br />\nPortland Maine 04101&nbsp;<br />\nCAGE: 6U557</p>\n\n<p>Industrial Supply/McGill Hose and Coupling<br />\n35 Industrial Parkway<br />\nWoburn, MA 01801<br />\nCAGE: 7L974</p>\n\n<p>Amesbury Industrial Supply<br />\n24 High Street<br />\nAmesbury, MA 01913-2422&nbsp;<br />\nCAGE: 1FF43</p>\n\n<p>Omni Services<br />\n15 Banfield Road Unit 3<br />\nPortsmouth, NH 03801-5607<br />\nCAGE: 3QQK1</p>\n\n<p>Tru-Flex Metal Hose LLC<br />\n2391 S State Road<br />\nWest Lebanon, IN 47991-0247<br />\nCAGE: 331F6</p>\n\n<p>***</p>\n\n<p><br />\nTHERE IS NO ANTICIPATED DATE FOR A SOLICITATION AT THIS TIME.&nbsp;</p>\n\n<p><br />\n***End of Sources Sought Notice***</p>","origin":"detail"},"contacts":[{"name":"Emily Kritzman","role":"primary","email":"emily.kritzman@dla.mil"},{"name":"DLA-KME EMAIL BOX","role":"secondary","email":"DLA-KME-QUOTATIONS@DLA.MIL"}],"place_of_performance":{"zip":"03904","city":{"code":"37270","name":"Kittery"},"state":{"code":"ME","name":"Maine"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"03801-5000","city":"PORTSMOUTH","state":"NH","country":"USA"},"naics_codes":["326220"],"award":null,"attachments":[{"resource_id":"1bd91589b3504df6a4ed8fa03c9f7372","name":"25Q3109 Sources Sought Attach 1 SPEC.docx","kind":"file","mime_type":".docx","size_bytes":20887,"posted_at":"2025-01-08T21:09:50.572Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1bd91589b3504df6a4ed8fa03c9f7372/download","mirrored":false}],"awards":[],"related":[{"key":"SPMYM327Q4006","latest_notice_id":"362547f85079423689245b007a6faac2","title":"LEVEL 1 Round Bar","solicitation_number":"SPMYM327Q4006","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-30T05:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T05:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM3","office_name":"DLA MARITIME - PORTSMOUTH","naics":"331221","psc":"9510","set_aside":"SBA","state":"ME","county":"23031","county_name":"York County","city":"2337235","city_name":"Kittery","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"SPMYM327Q4011","latest_notice_id":"5ddc20ff0b214474bc804d21708982b1","title":"Hardware","solicitation_number":"SPMYM327Q4011","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM3","office_name":"DLA MARITIME - PORTSMOUTH","naics":"332722","psc":"5305","set_aside":"SBA","state":"ME","county":"23031","county_name":"York County","city":"2337235","city_name":"Kittery","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"SPMYM327Q6006","latest_notice_id":"b4651b71f86d488a864799a01f125a95","title":"Luff Hoist RRL & LRL Wire ropes","solicitation_number":"SPMYM327Q6006","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM3","office_name":"DLA MARITIME - PORTSMOUTH","naics":"333923","psc":"4010","set_aside":"SBA","state":"ME","county":"23031","county_name":"York County","city":"2337235","city_name":"Kittery","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"SPMYM327Q5004","latest_notice_id":"0b24b29c406b4386b240196ec0e6ad6a","title":"Level 1 Silver Brazing Rings","solicitation_number":"SPMYM327Q5004","notice_type":"k","first_type":"k","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM3","office_name":"DLA MARITIME - PORTSMOUTH","naics":"333992","psc":"3439","set_aside":null,"state":"ME","county":"23031","county_name":"York County","city":"2337235","city_name":"Kittery","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"SPMYM327Q7006","latest_notice_id":"cef486a6606a4c76aba633bbad73e07d","title":"Cap Screws","solicitation_number":"SPMYM327Q7006","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM3","office_name":"DLA MARITIME - PORTSMOUTH","naics":"332722","psc":"5305","set_aside":"SBA","state":"ME","county":"23031","county_name":"York County","city":"2337235","city_name":"Kittery","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"N4215827QE015","latest_notice_id":"791c40ed67ce44e0a92e17469b251263","title":"NNSY HOSE ASSEMBLY (AEROQUIP)","solicitation_number":"N4215827QE015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","naics":"326220","psc":"4720","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N0010425QFE15","latest_notice_id":"eca8328deeab40318663fe64065878ef","title":"HOSE ASSEMBLY,SPECI","solicitation_number":"N0010425QFE15","notice_type":"o","first_type":"o","first_posted":"2025-06-30","last_posted":"2026-11-18","notices":5,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"326220","psc":"4720","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4720)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"SPE7LX27U0953","latest_notice_id":"6a5d168da732493ea83f333849d74842","title":"53--PACKING,PREFORMED","solicitation_number":"SPE7LX27U0953","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7LX","office_name":"DLA WEAPONS SUPPORT","naics":"326220","psc":"53","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"NTITY WILL BE 3. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":39,"indexable":false}