{"canonical":"https://sealedbidder.com/opportunities/sp330027q0012","key":"SP330027Q0012","url":"https://sealedbidder.com/opportunities/sp330027q0012","title":"Electric Power Resiliency Building 56","solicitation_number":"SP330027Q0012","notice_type":"k","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-12-09T18:00:00Z","first_posted":"2026-11-10","last_posted":"2026-11-16","department":"DEPT OF DEFENSE","subagency":"DEFENSE LOGISTICS AGENCY","office":"DLA DISTRIBUTION","naics":"238210","psc":"Z2GZ","set_aside":"SBA","place_state":null,"place_scope":"unknown","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"ee3c354d33444f8ea8302fb2f23df40c","title":"Electric Power Resiliency Building 56","solicitation_number":"SP330027Q0012","notice_type":"k","base_type":"k","posted":"2026-11-10","posted_at":"2026-11-10T19:07:36.417Z","due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","cancelled":false,"archived":false,"archive_date":"2027-03-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ee3c354d33444f8ea8302fb2f23df40c/view","enriched":true,"history":[{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}]},{"notice_id":"9a99b38488df4a31a78b196b7e16f0a8","title":"Electric Power Resiliency Building 56","solicitation_number":"SP330027Q0012","notice_type":"k","base_type":"k","posted":"2026-11-12","posted_at":"2026-11-12T19:54:02.156Z","due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","cancelled":false,"archived":false,"archive_date":"2027-03-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9a99b38488df4a31a78b196b7e16f0a8/view","enriched":true,"history":[{"index":2,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T19:54:02.156Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9a99b38488df4a31a78b196b7e16f0a8","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}]},{"notice_id":"08ca315dd7f74f64bd118120a4f094aa","title":"Electric Power Resiliency Building 56","solicitation_number":"SP330027Q0012","notice_type":"k","base_type":"k","posted":"2026-11-13","posted_at":"2026-11-13T16:05:48.289Z","due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","cancelled":false,"archived":false,"archive_date":"2027-03-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/08ca315dd7f74f64bd118120a4f094aa/view","enriched":true,"history":[{"index":3,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-13T16:05:48.289Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"08ca315dd7f74f64bd118120a4f094aa","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":2,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T19:54:02.156Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9a99b38488df4a31a78b196b7e16f0a8","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}]},{"notice_id":"f2e61a65f7bf4ad09ddc552b7ed8dd8e","title":"Electric Power Resiliency Building 56","solicitation_number":"SP330027Q0012","notice_type":"k","base_type":"k","posted":"2026-11-16","posted_at":"2026-11-16T16:02:54.990Z","due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","cancelled":false,"archived":false,"archive_date":"2027-03-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f2e61a65f7bf4ad09ddc552b7ed8dd8e/view","enriched":true,"history":[{"index":4,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-16T16:02:54.990Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f2e61a65f7bf4ad09ddc552b7ed8dd8e","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":3,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-13T16:05:48.289Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"08ca315dd7f74f64bd118120a4f094aa","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":2,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T19:54:02.156Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9a99b38488df4a31a78b196b7e16f0a8","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}]}],"latest_notice_id":"f2e61a65f7bf4ad09ddc552b7ed8dd8e","first_type":"k","notices":[{"dates":{"posted":"2026-11-10","posted_at":"2026-11-10T19:07:36.417Z","created_at":"2026-11-10T19:07:36.310Z","modified_at":"2026-11-10T19:07:36.417Z","response_deadline":{"raw":"2026-12-09T13:00:00-05:00","utc":"2026-12-09T18:00:00Z","date":"2026-12-09","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ee3c354d33444f8ea8302fb2f23df40c/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Electric Power Resiliency Building 56","agency":{"office":{"code":"SP3300","name":"DLA DISTRIBUTION"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"17070-5002","city":"NEW CUMBERLAND","state":"PA","country":"USA"},"organization_id":"500045599","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-31","archive_type":"auto_custom"},"history":[{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}],"contacts":[{"name":"PAUL HOLBERT","role":"primary","email":"paul.holbert@dla.mil","phone":"6146935733"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"ee3c354d33444f8ea8302fb2f23df40c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ee3c354d33444f8ea8302fb2f23df40c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T07:52:16.756751831Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"0257206118ebe9482b80da2b24f1e441-27\"","fetched_at":"2026-11-11T04:50:18.941800608Z","row_sha256":"0084ae3327456edb1b4de9e451f567972cdc9c224f30aaed8124703d8f6f79e5","last_modified":"2026-11-11T04:30:18Z"},"updated_at":"2026-11-12T07:52:16.756751831Z","first_seen_at":"2026-11-11T04:50:18.941800608Z"},"description":{"html":"This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish  at theDefense Distribution San Joaquin California.Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaicsystem for building 56. but not limited to:The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed thelisting and qualification tests. All design and installation shall comply with the most recent version of each document.The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor.The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistentwith and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines.There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame sizecircuit breaker spaces are available.","text":"This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at theDefense Distribution San Joaquin California.Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaicsystem for building 56. but not limited to:The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed thelisting and qualification tests. All design and installation shall comply with the most recent version of each document.The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor.The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistentwith and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines.There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame sizecircuit breaker spaces are available.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"SP330027Q0012","place_of_performance":{"zip":"95304","street":"Tracy CA"},"product_service_code":"Z2GZ"},{"dates":{"posted":"2026-11-12","posted_at":"2026-11-12T19:54:02.156Z","created_at":"2026-11-12T19:54:00.965Z","modified_at":"2026-11-12T19:54:02.156Z","response_deadline":{"raw":"2026-12-09T13:00:00-05:00","utc":"2026-12-09T18:00:00Z","date":"2026-12-09","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9a99b38488df4a31a78b196b7e16f0a8/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Electric Power Resiliency Building 56","agency":{"office":{"code":"SP3300","name":"DLA DISTRIBUTION"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"17070-5002","city":"NEW CUMBERLAND","state":"PA","country":"USA"},"organization_id":"500045599","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-31","archive_type":"auto_custom"},"history":[{"index":2,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T19:54:02.156Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9a99b38488df4a31a78b196b7e16f0a8","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}],"contacts":[{"name":"PAUL HOLBERT","role":"primary","email":"paul.holbert@dla.mil","phone":"6146935733"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"9a99b38488df4a31a78b196b7e16f0a8","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ee3c354d33444f8ea8302fb2f23df40c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-13T06:36:04.633134982Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"7ba2d1e3bb2c190af43f4e83137c445a-27\"","fetched_at":"2026-11-13T05:16:19.555733301Z","row_sha256":"a313ded19c5acddca2d0c33c01c9c34f9a18b6da2539dbb17b281338e7fc3672","last_modified":"2026-11-13T04:30:18Z"},"updated_at":"2026-11-13T06:36:04.633134982Z","first_seen_at":"2026-11-13T05:16:19.555733301Z"},"description":{"html":"Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish  at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","text":"Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"SP330027Q0012","place_of_performance":{"zip":"95304","street":"Tracy CA"},"product_service_code":"Z2GZ"},{"dates":{"posted":"2026-11-13","posted_at":"2026-11-13T16:05:48.289Z","created_at":"2026-11-13T16:05:47.526Z","modified_at":"2026-11-13T16:05:48.289Z","response_deadline":{"raw":"2026-12-09T13:00:00-05:00","utc":"2026-12-09T18:00:00Z","date":"2026-12-09","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/08ca315dd7f74f64bd118120a4f094aa/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Electric Power Resiliency Building 56","agency":{"office":{"code":"SP3300","name":"DLA DISTRIBUTION"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"17070-5002","city":"NEW CUMBERLAND","state":"PA","country":"USA"},"organization_id":"500045599","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-31","archive_type":"auto_custom"},"history":[{"index":3,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-13T16:05:48.289Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"08ca315dd7f74f64bd118120a4f094aa","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":2,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T19:54:02.156Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9a99b38488df4a31a78b196b7e16f0a8","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}],"contacts":[{"name":"PAUL HOLBERT","role":"primary","email":"paul.holbert@dla.mil","phone":"6146935733"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"08ca315dd7f74f64bd118120a4f094aa","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ee3c354d33444f8ea8302fb2f23df40c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-14T23:22:56.353291458Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"d9cb0cc47d6e1c814f4476c5bd0dd2db-27\"","fetched_at":"2026-11-14T05:13:21.634727272Z","row_sha256":"27b295a65734d790179e84e88474172254093782a92b79dd079421095789e831","last_modified":"2026-11-14T04:30:20Z"},"updated_at":"2026-11-14T23:22:56.353291458Z","first_seen_at":"2026-11-14T05:13:21.634727272Z"},"description":{"html":"Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish  at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","text":"Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"SP330027Q0012","place_of_performance":{"zip":"95304","street":"Tracy CA"},"product_service_code":"Z2GZ"},{"dates":{"posted":"2026-11-16","posted_at":"2026-11-16T16:02:54.990Z","created_at":"2026-11-16T16:02:53.917Z","modified_at":"2026-11-16T16:02:54.990Z","response_deadline":{"raw":"2026-12-09T13:00:00-05:00","utc":"2026-12-09T18:00:00Z","date":"2026-12-09","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f2e61a65f7bf4ad09ddc552b7ed8dd8e/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Electric Power Resiliency Building 56","agency":{"office":{"code":"SP3300","name":"DLA DISTRIBUTION"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"17070-5002","city":"NEW CUMBERLAND","state":"PA","country":"USA"},"organization_id":"500045599","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-31","archive_type":"auto_custom"},"history":[{"index":4,"title":"Electric Power Resiliency Building 56","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-16T16:02:54.990Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f2e61a65f7bf4ad09ddc552b7ed8dd8e","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":3,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-13T16:05:48.289Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"08ca315dd7f74f64bd118120a4f094aa","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":2,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T19:54:02.156Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9a99b38488df4a31a78b196b7e16f0a8","solicitation_number":"SP330027Q0012","parent_opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c"},{"index":1,"title":"Electric Power Resiliency Building 56","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:07:36.417Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ee3c354d33444f8ea8302fb2f23df40c","solicitation_number":"SP330027Q0012"}],"contacts":[{"name":"PAUL HOLBERT","role":"primary","email":"paul.holbert@dla.mil","phone":"6146935733"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"f2e61a65f7bf4ad09ddc552b7ed8dd8e","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ee3c354d33444f8ea8302fb2f23df40c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T07:34:27.861840646Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"85e14329eca27c595e9baeb82aefb456-27\"","fetched_at":"2026-11-17T04:39:38.100364673Z","row_sha256":"d57f88bcbabd369f28ac605d9aef7730135d028bf236d0401dce21c4b0543d05","last_modified":"2026-11-17T04:30:19Z"},"updated_at":"2026-11-17T07:34:27.861840646Z","first_seen_at":"2026-11-17T04:39:38.100364673Z"},"description":{"html":"Amendment 0003 is being issued to change the original SF1449 cover page to correct Block 8 from 12/07/2026 to 12/09/2026 as provided for in the rest of the solicitation.  Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish  at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","text":"Amendment 0003 is being issued to change the original SF1449 cover page to correct Block 8 from 12/07/2026 to 12/09/2026 as provided for in the rest of the solicitation. Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"SP330027Q0012","place_of_performance":{"zip":"95304","street":"Tracy CA"},"product_service_code":"Z2GZ"}],"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-17T04:42:47.571825Z","principal_notice_id":"f2e61a65f7bf4ad09ddc552b7ed8dd8e","description":{"text":"Amendment 0003 is being issued to change the original SF1449 cover page to correct Block 8 from 12/07/2026 to 12/09/2026 as provided for in the rest of the solicitation. Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","html":"Amendment 0003 is being issued to change the original SF1449 cover page to correct Block 8 from 12/07/2026 to 12/09/2026 as provided for in the rest of the solicitation.  Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish  at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.","origin":"detail"},"contacts":[{"name":"PAUL HOLBERT","role":"primary","email":"paul.holbert@dla.mil","phone":"6146935733"}],"place_of_performance":{"zip":"95304","street":"Tracy CA"},"office_address":{"zip":"17070-5002","city":"NEW CUMBERLAND","state":"PA","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[{"resource_id":"8a7c09bd601848cfab08ddecdfc412af","name":"Department of Defense Procurement Toolbox","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-10T19:07:36.417Z","export_controlled":false,"sha256":null,"url":"https://toolbox-piee.eb.mil/","mirrored":false},{"resource_id":"93a4a95a5a5e4db78ec169b195a90458","name":"Registration Instructions for the PIEE Solicitation Module","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-10T19:07:36.417Z","export_controlled":false,"sha256":null,"url":"https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf","mirrored":false},{"resource_id":"38da9e4a395d4c558dfaecf3da8eac16","name":"Web Based Training for the PIEE Solicitation Module","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-10T19:07:36.417Z","export_controlled":false,"sha256":null,"url":"https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml","mirrored":false},{"resource_id":"e4591e5125024d58977bc0b6479796a1","name":"PIEE Solicitation Module Link for SP330027Q0012","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-10T19:07:36.417Z","export_controlled":false,"sha256":null,"url":"https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=SP330027Q0012&noticeType=CombinedSynopsisSolicitation","mirrored":false}],"awards":[],"related":[{"key":"SP330027Q0037","latest_notice_id":"15eabc45d39f4c05a8b10a85d5eb04af","title":"Barrier Material for Red River","solicitation_number":"SP3300-27-Q-0037","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"326112","psc":"8135","set_aside":"SBA","state":"TX","county":"48037","county_name":"Bowie County","city":"4872368","city_name":"Texarkana","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SP330027Q0035","latest_notice_id":"8d7c8757b48b4cac9cd6fee70553c976","title":"DDAA Forklift Rentals","solicitation_number":"SP330027Q0035","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"532490","psc":"W039","set_aside":null,"state":"AL","county":"01015","county_name":"Calhoun County","city":"0101852","city_name":"Anniston","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"SP330027Q0036","latest_notice_id":"95b60d2e54fb4285a505d703eabeac5a","title":"Oxygen Bottle Shipping Containers","solicitation_number":"SP330027Q0036","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-07T17:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"332439","psc":"8145","set_aside":"SBA","state":"CA","county":"06077","county_name":"San Joaquin County","city":"0680238","city_name":"Tracy","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SP330027Q0011","latest_notice_id":"45066985ccdb460a8380113ba1f54d04","title":"Cross Connection Hazard Assessment","solicitation_number":"SP330027Q0011","notice_type":"k","first_type":"k","first_posted":"2026-11-06","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-14T17:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"541380","psc":"F107","set_aside":"SBA","state":"CA","county":"06077","county_name":"San Joaquin County","city":"0680238","city_name":"Tracy","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"SP330025Q5012","latest_notice_id":"54b07db33bdb49729b67a65ce5f288a6","title":"Cushion Packaging Material LTC for DLA","solicitation_number":"SP330025Q5012","notice_type":"k","first_type":"k","first_posted":"2025-04-28","last_posted":"2025-06-03","notices":3,"due_at":"2029-05-29T19:00:00Z","due_date":"2029-05-29","closes_at":"2029-05-29T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"326140","psc":"8135","set_aside":"SBA","state":"PA","county":"42133","county_name":"York County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"N6893627Q0028","latest_notice_id":"b80f8c2632fc496ca50fac60c257cbb8","title":"AECS and Installation","solicitation_number":"N6893627Q0028","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T00:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-04T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N68936","office_name":"NAVAL AIR WARFARE CENTER","naics":"238210","psc":"6350","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6350)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027B00021","latest_notice_id":"f14011e030dc4ff2b67287c1a0a65a30","title":"Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution.","solicitation_number":"36C25027B0002_1","notice_type":"o","first_type":"o","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-12-09T15:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"Z1DA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"DOIASAM270006","latest_notice_id":"ae9341b336f7412d981ef5b0b49d2d63","title":"S--BIA Electrical Utility O&M Services","solicitation_number":"DOIASAM270006","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1450","sub_name":"BUREAU OF INDIAN AFFAIRS","office_key":"o-140A11","office_name":"WESTERN REGION","naics":"238210","psc":"S112","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"T; EMERGENCY RESPONSE OPERATIONS; AND REMOTE","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open_total":38,"indexable":true}