{"canonical":"https://sealedbidder.com/opportunities/slac366098atcacrate","key":"SLAC366098ATCACRATE","url":"https://sealedbidder.com/opportunities/slac366098atcacrate","title":"ATCA crate","solicitation_number":"SLAC_366098_ATCACrate","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-16T00:00:00Z","first_posted":"2026-07-09","last_posted":"2026-07-09","department":"ENERGY, DEPARTMENT OF","subagency":"ENERGY, DEPARTMENT OF","office":"SLAC Natl Accel Lab -DOE Contractor","naics":"3333","psc":"AJ12","set_aside":null,"place_state":"CA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"06081","place_county_name":"San Mateo County","place_city":"0646870","place_city_name":"Menlo Park","winner":null,"award_amount":null,"publications":[{"notice_id":"9a46c194f3444d4e91dd190b8e3bcef8","title":"ATCA crate","solicitation_number":"SLAC_366098_ATCACrate","notice_type":"o","base_type":"o","posted":"2026-07-09","posted_at":"2026-07-09T19:27:58.506Z","due_at":"2026-07-16T00:00:00Z","due_date":"2026-07-15","cancelled":false,"archived":true,"archive_date":"2026-07-30","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9a46c194f3444d4e91dd190b8e3bcef8/view","enriched":true,"history":[{"index":3,"title":"ATCA crate","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T19:27:58.506Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9a46c194f3444d4e91dd190b8e3bcef8","solicitation_number":"SLAC_366098_ATCACrate"}]}],"latest_notice_id":"9a46c194f3444d4e91dd190b8e3bcef8","first_type":"o","notices":[{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T19:27:58.506Z","created_at":"2026-07-09T19:23:27.936Z","modified_at":"2026-07-30T05:07:21.536Z","response_deadline":{"raw":"2026-07-15T17:00:00-07:00","utc":"2026-07-16T00:00:00Z","date":"2026-07-15","time":"17:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9a46c194f3444d4e91dd190b8e3bcef8/view"},"naics":{"codes":["3333"],"primary":"3333"},"title":"ATCA crate","agency":{"office":{"code":"899040","name":"SLAC Natl Accel Lab -DOE Contractor"},"subtier":{"code":"8900","name":"ENERGY, DEPARTMENT OF"},"department":{"code":"089","name":"ENERGY, DEPARTMENT OF"},"office_address":{"zip":"94025","city":"Menlo Park","state":"CA","country":"USA"},"organization_id":"500046233","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-30","archive_type":"auto15"},"history":[{"index":3,"title":"ATCA crate","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T19:27:58.506Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9a46c194f3444d4e91dd190b8e3bcef8","solicitation_number":"SLAC_366098_ATCACrate"}],"contacts":[{"name":"Katherine Jill A. Coh","role":"primary","email":"kcoh@slac.stanford.edu","phone":"6509262770"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9a46c194f3444d4e91dd190b8e3bcef8","lineage_id":"9a46c194f3444d4e91dd190b8e3bcef8","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T02:46:22.409414885Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"14f44f493ee8217324ef4215ba671aa00aca67533c412be82927916549843ce9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T02:46:22.409414885Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.</p>\n\n<p><br />\nThe follow has been attached for you to complete and review:</p>\n\n<p></p>\n\n<p>1.) Quote</p>\n\n<p>2.) Reps &amp; Certs</p>\n\n<p>3.) FP Commercial Supplies-Services T&amp;C&rsquo;s ( August&nbsp; 2023 )</p>\n\n<p>4.) Buy American Act (BAA)</p>\n\n<p></p>\n\n<p></p>\n\n<p>Requested for Quote:</p>\n\n<p>Technical Specifications Listed below:</p>\n\n<p><strong>1.1 </strong>Product must support 4-Slots in a 4U rack space. (Two independent switch slots and 2-slots for application slots).</p>\n\n<p><strong>1.2 </strong>Product shall be 40G compatible, dual star or fully replicated mesh backplane</p>\n\n<p><strong>1.3 </strong>Product Shelf Manager must have front panel Ethernet interface for RMCP and front panel RJ45 - RS232 interface for console access.</p>\n\n<p><strong>1.4 </strong>Product shall possess redundant shelf manager support and include a fully compliant shelf manager that runs pigeon point software SHM700 or higher.&nbsp;</p>\n\n<p><strong>1.5 </strong>Product must support AC input power configuration</p>\n\n<p><strong>1.6 </strong>Product shall have Hot-swap and redundant power supply support and have at least one 1100W AC power supply at 110V input (low-line input range VAC 85-132).</p>\n\n<p><strong>1.7 </strong>Product shall have Hot-swap and redundant fan tray installed with fan speed adjustable.</p>\n\n<p><strong>1.8 </strong>Product must provide cooling at normal operating for at least 300W per front slot and 36W per rear slot.</p>\n\n<p><strong>1.9 </strong>Product shall have switch slot located at the top and application slots located at the bottom. The bottom panel shall be removable or allow for a cutout opening to provide access to the internal board slot 4.</p>\n\n<p><strong>1.10 </strong>Product Ambient Operation Temperature Range shall be 0 ~ 50C.</p>\n\n<p><strong>1.11 </strong>Product shall have clearance space for all RTM boards</p>\n\n<p><strong>1.12 </strong>Product shall have removable air filter(s).</p>\n\n<p><strong>1.13 </strong>Product shall have labels for all logical slots.</p>\n\n<p><strong>1.14 </strong>Product shall have Three (3) Year Warranty from time of delivery for all part and labor.</p>\n\n<p><strong>2. Schedule and Delivery Date.&nbsp; </strong>Offeror shall quote product lead time as weeks after receipt of order (ARO) meeting the University&rsquo;s project schedule or an alternate schedule acceptable to the University.</p>\n\n<p></p>\n\n<p>Required item(s) are listed below:</p>\n\n<p></p>\n\n<p>11A04GJA48Y4HGBS-SLAC2 &ndash; qty 3</p>\n\n<p>Mechanical PNRE &ndash; qty 1</p>\n\n<p>Backplane NRE- qty 1</p>\n\n<p></p>\n\n<p>Quote is for product only; no on-site services permitted.</p>\n\n<p></p>\n\n<p>Source selection will be based on Lowest Priced Method and best Lead-Time.</p>\n\n<p></p>\n\n<p>Please provide a price and lead time quotation by 7/15/2026.</p>\n\n<p><strong>Send quote to </strong><strong>Jhamieb@SLAC.stanford.edu</strong><strong>.</strong></p>\n\n<p></p>\n\n<p>Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?</p>\n\n<p></p>\n\n<p>Buy American Act Certification (BAA) applies to awards over $15,000 unit price.</p>\n\n<p></p>\n\n<p>Representations &amp; Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.</p>\n\n<p></p>\n\n<p><em>Please include in your proposals the <strong><u>Harmonized Tariff Schedule (HTS Code)&amp; </u></strong></em><strong><u>Export Control Classification Number (ECCN)</u></strong> <em>&nbsp;if applicable.</em></p>\n\n<p></p>\n\n<p>All subcontractors are required to register in the System for Award Management (www.sam.gov).</p>\n\n<p></p>\n\n<p>If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.</p>\n\n<p></p>\n\n<p>The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order. Please mark up terms and conditions if you wish to negotiate. No mark ups mean that you accept SLAC Terms and Conditions.</p>\n\n<p></p>\n\n<p>Payment Terms will be NET-30</p>\n\n<p></p>\n\n<p><strong><u>Domestic Suppliers</u> - Freight terms will be FOB Destination Prepaid and Add. </strong></p>\n\n<p><strong><u>Foreign Supplier</u> - Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid.</strong></p>\n\n<p></p>\n\n<p>You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.</p>\n\n<p></p>\n\n<p>Contact me directly with any questions.</p>\n\n<p></p>\n\n<p></p>\n\n<p>Kind Regards,</p>\n\n<p></p>\n\n<p></p>\n\n<p>Jhamie Serena</p>\n\n<p><strong>Procurement Commodities Team</strong></p>\n\n<p>SLAC National Accelerator Laboratory</p>\n\n<p>2575 Sand Hill Road Menlo Park, CA 94025</p>\n\n<p>P- 650-926-2201</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.\n\nThe follow has been attached for you to complete and review:\n\n1.) Quote\n\n2.) Reps & Certs\n\n3.) FP Commercial Supplies-Services T&C’s ( August 2023 )\n\n4.) Buy American Act (BAA)\n\nRequested for Quote:\n\nTechnical Specifications Listed below:\n\n1.1 Product must support 4-Slots in a 4U rack space. (Two independent switch slots and 2-slots for application slots).\n\n1.2 Product shall be 40G compatible, dual star or fully replicated mesh backplane\n\n1.3 Product Shelf Manager must have front panel Ethernet interface for RMCP and front panel RJ45 - RS232 interface for console access.\n\n1.4 Product shall possess redundant shelf manager support and include a fully compliant shelf manager that runs pigeon point software SHM700 or higher.\n\n1.5 Product must support AC input power configuration\n\n1.6 Product shall have Hot-swap and redundant power supply support and have at least one 1100W AC power supply at 110V input (low-line input range VAC 85-132).\n\n1.7 Product shall have Hot-swap and redundant fan tray installed with fan speed adjustable.\n\n1.8 Product must provide cooling at normal operating for at least 300W per front slot and 36W per rear slot.\n\n1.9 Product shall have switch slot located at the top and application slots located at the bottom. The bottom panel shall be removable or allow for a cutout opening to provide access to the internal board slot 4.\n\n1.10 Product Ambient Operation Temperature Range shall be 0 ~ 50C.\n\n1.11 Product shall have clearance space for all RTM boards\n\n1.12 Product shall have removable air filter(s).\n\n1.13 Product shall have labels for all logical slots.\n\n1.14 Product shall have Three (3) Year Warranty from time of delivery for all part and labor.\n\n2. Schedule and Delivery Date. Offeror shall quote product lead time as weeks after receipt of order (ARO) meeting the University’s project schedule or an alternate schedule acceptable to the University.\n\nRequired item(s) are listed below:\n\n11A04GJA48Y4HGBS-SLAC2 – qty 3\n\nMechanical PNRE – qty 1\n\nBackplane NRE- qty 1\n\nQuote is for product only; no on-site services permitted.\n\nSource selection will be based on Lowest Priced Method and best Lead-Time.\n\nPlease provide a price and lead time quotation by 7/15/2026.\n\nSend quote to Jhamieb@SLAC.stanford.edu.\n\nIs there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?\n\nBuy American Act Certification (BAA) applies to awards over $15,000 unit price.\n\nRepresentations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.\n\nPlease include in your proposals the Harmonized Tariff Schedule (HTS Code)& Export Control Classification Number (ECCN) if applicable.\n\nAll subcontractors are required to register in the System for Award Management (www.sam.gov).\n\nIf possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.\n\nThe resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order. Please mark up terms and conditions if you wish to negotiate. No mark ups mean that you accept SLAC Terms and Conditions.\n\nPayment Terms will be NET-30\n\nDomestic Suppliers - Freight terms will be FOB Destination Prepaid and Add.\n\nForeign Supplier - Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid.\n\nYou are requested to mark and identify proprietary/confidential information provided in response to the solicitation.\n\nContact me directly with any questions.\n\nKind Regards,\n\nJhamie Serena\n\nProcurement Commodities Team\n\nSLAC National Accelerator Laboratory\n\n2575 Sand Hill Road Menlo Park, CA 94025\n\nP- 650-926-2201","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"SLAC_366098_ATCACrate","place_of_performance":{"zip":"94025","city":{"code":"46870","name":"Menlo Park"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"AJ12"}],"due_at":"2026-07-16T00:00:00Z","due_date":"2026-07-15","closes_at":"2026-07-16T00:00:00Z","awardable":true,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T03:29:01.199186Z","principal_notice_id":"9a46c194f3444d4e91dd190b8e3bcef8","description":{"text":"SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.\n\nThe follow has been attached for you to complete and review:\n\n1.) Quote\n\n2.) Reps & Certs\n\n3.) FP Commercial Supplies-Services T&C’s ( August 2023 )\n\n4.) Buy American Act (BAA)\n\nRequested for Quote:\n\nTechnical Specifications Listed below:\n\n1.1 Product must support 4-Slots in a 4U rack space. (Two independent switch slots and 2-slots for application slots).\n\n1.2 Product shall be 40G compatible, dual star or fully replicated mesh backplane\n\n1.3 Product Shelf Manager must have front panel Ethernet interface for RMCP and front panel RJ45 - RS232 interface for console access.\n\n1.4 Product shall possess redundant shelf manager support and include a fully compliant shelf manager that runs pigeon point software SHM700 or higher.\n\n1.5 Product must support AC input power configuration\n\n1.6 Product shall have Hot-swap and redundant power supply support and have at least one 1100W AC power supply at 110V input (low-line input range VAC 85-132).\n\n1.7 Product shall have Hot-swap and redundant fan tray installed with fan speed adjustable.\n\n1.8 Product must provide cooling at normal operating for at least 300W per front slot and 36W per rear slot.\n\n1.9 Product shall have switch slot located at the top and application slots located at the bottom. The bottom panel shall be removable or allow for a cutout opening to provide access to the internal board slot 4.\n\n1.10 Product Ambient Operation Temperature Range shall be 0 ~ 50C.\n\n1.11 Product shall have clearance space for all RTM boards\n\n1.12 Product shall have removable air filter(s).\n\n1.13 Product shall have labels for all logical slots.\n\n1.14 Product shall have Three (3) Year Warranty from time of delivery for all part and labor.\n\n2. Schedule and Delivery Date. Offeror shall quote product lead time as weeks after receipt of order (ARO) meeting the University’s project schedule or an alternate schedule acceptable to the University.\n\nRequired item(s) are listed below:\n\n11A04GJA48Y4HGBS-SLAC2 – qty 3\n\nMechanical PNRE – qty 1\n\nBackplane NRE- qty 1\n\nQuote is for product only; no on-site services permitted.\n\nSource selection will be based on Lowest Priced Method and best Lead-Time.\n\nPlease provide a price and lead time quotation by 7/15/2026.\n\nSend quote to Jhamieb@SLAC.stanford.edu.\n\nIs there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?\n\nBuy American Act Certification (BAA) applies to awards over $15,000 unit price.\n\nRepresentations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.\n\nPlease include in your proposals the Harmonized Tariff Schedule (HTS Code)& Export Control Classification Number (ECCN) if applicable.\n\nAll subcontractors are required to register in the System for Award Management (www.sam.gov).\n\nIf possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.\n\nThe resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order. Please mark up terms and conditions if you wish to negotiate. No mark ups mean that you accept SLAC Terms and Conditions.\n\nPayment Terms will be NET-30\n\nDomestic Suppliers - Freight terms will be FOB Destination Prepaid and Add.\n\nForeign Supplier - Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid.\n\nYou are requested to mark and identify proprietary/confidential information provided in response to the solicitation.\n\nContact me directly with any questions.\n\nKind Regards,\n\nJhamie Serena\n\nProcurement Commodities Team\n\nSLAC National Accelerator Laboratory\n\n2575 Sand Hill Road Menlo Park, CA 94025\n\nP- 650-926-2201","html":"<p>SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.</p>\n\n<p><br />\nThe follow has been attached for you to complete and review:</p>\n\n<p></p>\n\n<p>1.) Quote</p>\n\n<p>2.) Reps &amp; Certs</p>\n\n<p>3.) FP Commercial Supplies-Services T&amp;C&rsquo;s ( August&nbsp; 2023 )</p>\n\n<p>4.) Buy American Act (BAA)</p>\n\n<p></p>\n\n<p></p>\n\n<p>Requested for Quote:</p>\n\n<p>Technical Specifications Listed below:</p>\n\n<p><strong>1.1 </strong>Product must support 4-Slots in a 4U rack space. (Two independent switch slots and 2-slots for application slots).</p>\n\n<p><strong>1.2 </strong>Product shall be 40G compatible, dual star or fully replicated mesh backplane</p>\n\n<p><strong>1.3 </strong>Product Shelf Manager must have front panel Ethernet interface for RMCP and front panel RJ45 - RS232 interface for console access.</p>\n\n<p><strong>1.4 </strong>Product shall possess redundant shelf manager support and include a fully compliant shelf manager that runs pigeon point software SHM700 or higher.&nbsp;</p>\n\n<p><strong>1.5 </strong>Product must support AC input power configuration</p>\n\n<p><strong>1.6 </strong>Product shall have Hot-swap and redundant power supply support and have at least one 1100W AC power supply at 110V input (low-line input range VAC 85-132).</p>\n\n<p><strong>1.7 </strong>Product shall have Hot-swap and redundant fan tray installed with fan speed adjustable.</p>\n\n<p><strong>1.8 </strong>Product must provide cooling at normal operating for at least 300W per front slot and 36W per rear slot.</p>\n\n<p><strong>1.9 </strong>Product shall have switch slot located at the top and application slots located at the bottom. The bottom panel shall be removable or allow for a cutout opening to provide access to the internal board slot 4.</p>\n\n<p><strong>1.10 </strong>Product Ambient Operation Temperature Range shall be 0 ~ 50C.</p>\n\n<p><strong>1.11 </strong>Product shall have clearance space for all RTM boards</p>\n\n<p><strong>1.12 </strong>Product shall have removable air filter(s).</p>\n\n<p><strong>1.13 </strong>Product shall have labels for all logical slots.</p>\n\n<p><strong>1.14 </strong>Product shall have Three (3) Year Warranty from time of delivery for all part and labor.</p>\n\n<p><strong>2. Schedule and Delivery Date.&nbsp; </strong>Offeror shall quote product lead time as weeks after receipt of order (ARO) meeting the University&rsquo;s project schedule or an alternate schedule acceptable to the University.</p>\n\n<p></p>\n\n<p>Required item(s) are listed below:</p>\n\n<p></p>\n\n<p>11A04GJA48Y4HGBS-SLAC2 &ndash; qty 3</p>\n\n<p>Mechanical PNRE &ndash; qty 1</p>\n\n<p>Backplane NRE- qty 1</p>\n\n<p></p>\n\n<p>Quote is for product only; no on-site services permitted.</p>\n\n<p></p>\n\n<p>Source selection will be based on Lowest Priced Method and best Lead-Time.</p>\n\n<p></p>\n\n<p>Please provide a price and lead time quotation by 7/15/2026.</p>\n\n<p><strong>Send quote to </strong><strong>Jhamieb@SLAC.stanford.edu</strong><strong>.</strong></p>\n\n<p></p>\n\n<p>Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?</p>\n\n<p></p>\n\n<p>Buy American Act Certification (BAA) applies to awards over $15,000 unit price.</p>\n\n<p></p>\n\n<p>Representations &amp; Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.</p>\n\n<p></p>\n\n<p><em>Please include in your proposals the <strong><u>Harmonized Tariff Schedule (HTS Code)&amp; </u></strong></em><strong><u>Export Control Classification Number (ECCN)</u></strong> <em>&nbsp;if applicable.</em></p>\n\n<p></p>\n\n<p>All subcontractors are required to register in the System for Award Management (www.sam.gov).</p>\n\n<p></p>\n\n<p>If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.</p>\n\n<p></p>\n\n<p>The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order. Please mark up terms and conditions if you wish to negotiate. No mark ups mean that you accept SLAC Terms and Conditions.</p>\n\n<p></p>\n\n<p>Payment Terms will be NET-30</p>\n\n<p></p>\n\n<p><strong><u>Domestic Suppliers</u> - Freight terms will be FOB Destination Prepaid and Add. </strong></p>\n\n<p><strong><u>Foreign Supplier</u> - Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid.</strong></p>\n\n<p></p>\n\n<p>You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.</p>\n\n<p></p>\n\n<p>Contact me directly with any questions.</p>\n\n<p></p>\n\n<p></p>\n\n<p>Kind Regards,</p>\n\n<p></p>\n\n<p></p>\n\n<p>Jhamie Serena</p>\n\n<p><strong>Procurement Commodities Team</strong></p>\n\n<p>SLAC National Accelerator Laboratory</p>\n\n<p>2575 Sand Hill Road Menlo Park, CA 94025</p>\n\n<p>P- 650-926-2201</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Katherine Jill A. Coh","role":"primary","email":"kcoh@slac.stanford.edu","phone":"6509262770"}],"place_of_performance":{"zip":"94025","city":{"code":"46870","name":"Menlo Park"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"94025","city":"Menlo Park","state":"CA","country":"USA"},"naics_codes":["3333"],"award":null,"attachments":[{"resource_id":"1d3e66e3513a4d568e0d587526f4daa3","name":"01. BAA_Certification_08.29.2023_(D5) (1).pdf","kind":"file","mime_type":".pdf","size_bytes":583314,"posted_at":"2026-07-09T19:27:58.506Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1d3e66e3513a4d568e0d587526f4daa3/download","mirrored":false}],"awards":[],"related":[{"key":"SLAC369019DCPOWERSUPPLY","latest_notice_id":"4e4acfada72244b6a547ec75e12df836","title":"DC Power Supply","solicitation_number":"SLAC_369019_DCPowerSupply","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"3333","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"REQ369230","latest_notice_id":"229f30abcc164940aae9b631b004159c","title":"Iris aiOne System","solicitation_number":"Req-369230","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"333310","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"SLACRFP369851AT","latest_notice_id":"c34e1b68f0f94733870a9e11ab9b97ef","title":"SPEAR Beam Position Monitors (BPMs)","solicitation_number":"SLAC_RFP369851_(AT)","notice_type":"o","first_type":"o","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-05T01:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-05T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"334516","psc":"6625","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"SLACNOV2026CHEMICALINVENTORYSYSTEMCIS","latest_notice_id":"ef38bb23d27d497da5149e0735097cf8","title":"SLAC_NOV2026_CHEMICAL_INVENTORY_SYSTEM (CIS)","solicitation_number":"SLAC_NOV2026_CHEMICAL_INVENTORY_SYSTEM_(CIS)","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-19","notices":3,"due_at":"2027-01-09T01:00:00Z","due_date":"2027-01-08","closes_at":"2027-01-09T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"32599","psc":"N068","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"SLAC369019DCPOWERSUPPLY","latest_notice_id":"4e4acfada72244b6a547ec75e12df836","title":"DC Power Supply","solicitation_number":"SLAC_369019_DCPowerSupply","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"3333","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":1,"indexable":false}