{"canonical":"https://sealedbidder.com/opportunities/slac358643rga","key":"SLAC358643RGA","url":"https://sealedbidder.com/opportunities/slac358643rga","title":"RGA","solicitation_number":"SLAC_358643_RGA","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-20T00:00:00Z","first_posted":"2025-09-04","last_posted":"2025-09-04","department":"ENERGY, DEPARTMENT OF","subagency":"ENERGY, DEPARTMENT OF","office":"SLAC Natl Accel Lab -DOE Contractor","naics":"3333","psc":"AJ12","set_aside":null,"place_state":"CA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"06081","place_county_name":"San Mateo County","place_city":"0646870","place_city_name":"Menlo Park","winner":null,"award_amount":null,"publications":[{"notice_id":"488c27e3fe744611a1615f6da707c91a","title":"RGA","solicitation_number":"SLAC_358643_RGA","notice_type":"o","base_type":"o","posted":"2025-09-04","posted_at":"2025-09-04T17:37:14.445Z","due_at":"2025-09-20T00:00:00Z","due_date":"2025-09-19","cancelled":false,"archived":true,"archive_date":"2025-10-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/488c27e3fe744611a1615f6da707c91a/view","enriched":true,"history":[{"index":3,"title":"RGA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-04T17:37:14.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"488c27e3fe744611a1615f6da707c91a","solicitation_number":"SLAC_358643_RGA"}]}],"latest_notice_id":"488c27e3fe744611a1615f6da707c91a","first_type":"o","notices":[{"dates":{"posted":"2025-09-04","posted_at":"2025-09-04T17:37:14.445Z","created_at":"2025-09-04T17:34:24.827Z","modified_at":"2025-10-05T04:00:11.067Z","response_deadline":{"raw":"2025-09-19T17:00:00-07:00","utc":"2025-09-20T00:00:00Z","date":"2025-09-19","time":"17:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/488c27e3fe744611a1615f6da707c91a/view"},"naics":{"codes":["3333"],"primary":"3333"},"title":"RGA","agency":{"office":{"code":"899040","name":"SLAC Natl Accel Lab -DOE Contractor"},"subtier":{"code":"8900","name":"ENERGY, DEPARTMENT OF"},"department":{"code":"089","name":"ENERGY, DEPARTMENT OF"},"office_address":{"zip":"94025","city":"Menlo Park","state":"CA","country":"USA"},"organization_id":"500046233","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-04","archive_type":"auto15"},"history":[{"index":3,"title":"RGA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-04T17:37:14.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"488c27e3fe744611a1615f6da707c91a","solicitation_number":"SLAC_358643_RGA"}],"contacts":[{"name":"Katherine Jill A. Coh","role":"primary","email":"kcoh@slac.stanford.edu","phone":"6509262770"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"488c27e3fe744611a1615f6da707c91a","lineage_id":"488c27e3fe744611a1615f6da707c91a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-01T01:52:24.872152193Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8f3d902d2523523b33319a7f74d0d10729f6662013e9da810ab3d6705c297081","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-01T01:52:24.872152193Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy.&nbsp; As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Required item(s) listed below</strong></p>\n\n<p></p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Mass range: 1&ndash;200 atomic mass units (amu)</p>\n\n<p>2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.</p>\n\n<p>3.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.</p>\n\n<p>4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Detector: Twin detector, Faraday cup and Channeltron electron multiplier.</p>\n\n<p>5.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.</p>\n\n<p>6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum measurement speed: 1000 measurements per second.</p>\n\n<p>7.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.</p>\n\n<p>8.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Filament: Twin filament. Oxide coated iridium.</p>\n\n<p>9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source control option:</p>\n\n<p>Electron emission: Software variable 1 &mu;A to 2 mA.</p>\n\n<p>Electron energy: Software variable 0 to 150 eV.</p>\n\n<p>Ion energy: Software variable 0 to 10 eV.</p>\n\n<p>10.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.</p>\n\n<p>RC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.</p>\n\n<p>8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).</p>\n\n<p>4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).</p>\n\n<p>11.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.</p>\n\n<p>12.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Analyzer mounting flange: DN-35-CF (2&frac34;&quot;/70 mm O.D. Conflat-type).</p>\n\n<p>13.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Dimensions:</p>\n\n<p>Analyzer insertion length from mounting flange face: 247 mm.</p>\n\n<p>RF head dimensions: Height &ndash; 117 mm, Width &ndash; 104 mm, Depth &ndash; 195 mm.</p>\n\n<p>Depth is distance from vacuum face of analyzer mounting flange.</p>\n\n<p>RC interface unit dimensions: Height: 90 mm. Width: 19&quot; rack mounting. Depth: 240 mm.</p>\n\n<p>14.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Cable lengths, RC interface to RF head: 40 m.</p>\n\n<p>15.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included</p>\n\n<p></p>\n\n<p>Quote is for product only; no on-site services permitted.</p>\n\n<p>Source selection will be based on Lowest Price and Technically Acceptable Method (LPTA).</p>\n\n<p></p>\n\n<p><strong>Technical evaluation criteria are as follows:</strong></p>\n\n<p></p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Mass range: 1&ndash;200 atomic mass units (amu)</p>\n\n<p>2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.</p>\n\n<p>3.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.</p>\n\n<p>4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Detector: Twin detector, Faraday cup and Channeltron electron multiplier.</p>\n\n<p>5.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.</p>\n\n<p>6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum measurement speed: 1000 measurements per second.</p>\n\n<p>7.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.</p>\n\n<p>8.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Filament: Twin filament. Oxide coated iridium.</p>\n\n<p>9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source control option:</p>\n\n<p>Electron emission: Software variable 1 &mu;A to 2 mA.</p>\n\n<p>Electron energy: Software variable 0 to 150 eV.</p>\n\n<p>Ion energy: Software variable 0 to 10 eV.</p>\n\n<p>10.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.</p>\n\n<p>RC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.</p>\n\n<p>8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).</p>\n\n<p>4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).</p>\n\n<p>11.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.</p>\n\n<p>12.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Analyzer mounting flange: DN-35-CF (2&frac34;&quot;/70 mm O.D. Conflat-type).</p>\n\n<p>13.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Dimensions:</p>\n\n<p>Analyzer insertion length from mounting flange face: 247 mm.</p>\n\n<p>RF head dimensions: Height &ndash; 117 mm, Width &ndash; 104 mm, Depth &ndash; 195 mm.</p>\n\n<p>Depth is distance from vacuum face of analyzer mounting flange.</p>\n\n<p>RC interface unit dimensions: Height: 90 mm. Width: 19&quot; rack mounting. Depth: 240 mm.</p>\n\n<p>14.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Cable lengths, RC interface to RF head: 40 m.</p>\n\n<p>15.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included.</p>\n\n<p></p>\n\n<p>Please provide a price and lead time quotation by 9/19/2023.</p>\n\n<p><strong>Send quote to emezzett@slac.stanford.edu.</strong></p>\n\n<p></p>\n\n<p>The bid closing date for this requirement is 9/19/2023.</p>\n\n<p></p>\n\n<p>Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?</p>\n\n<p></p>\n\n<p><strong>Buy American Act Certification (BAA</strong>) applies to awards that are over $10,000.</p>\n\n<p></p>\n\n<p><strong>Representations &amp; Certifications Rider</strong> is required. Once completed the Reps and Certs is valid for one year until</p>\n\n<p>renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.</p>\n\n<p></p>\n\n<p>All subcontractors are required to register in the System for Award Management (www.sam.gov).</p>\n\n<p>If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.</p>\n\n<p></p>\n\n<p>The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and</p>\n\n<p>Conditions for Fixed Price Commercial Supplies and Services (Rev. September 2022) will be made a part of the resulting</p>\n\n<p>order.</p>\n\n<p></p>\n\n<p>Payment Terms will be NET-30</p>\n\n<p></p>\n\n<p>Freight terms will be FOB Destination Prepaid and Add</p>\n\n<p></p>\n\n<p>You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.</p>\n\n<p>Contact me directly with any questions.</p>\n\n<p></p>\n\n<p>Kind regards,</p>\n\n<p></p>\n\n<p>Edward Mezzettta</p>\n\n<p>Procurement Commodities Team</p>\n\n<p>SLAC National Accelerator Laboratory</p>\n\n<p>2575 Sand Hill Road</p>\n\n<p>Menlo Park, CA 94025</p>\n\n<p>Email: emezzett@slac.stanford.edu</p>","text":"SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.\n\nRequired item(s) listed below\n\n1. Mass range: 1–200 atomic mass units (amu)\n\n2. Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.\n\n3. Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.\n\n4. Detector: Twin detector, Faraday cup and Channeltron electron multiplier.\n\n5. Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.\n\n6. Maximum measurement speed: 1000 measurements per second.\n\n7. Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.\n\n8. Filament: Twin filament. Oxide coated iridium.\n\n9. Ion Source control option:\n\nElectron emission: Software variable 1 μA to 2 mA.\n\nElectron energy: Software variable 0 to 150 eV.\n\nIon energy: Software variable 0 to 10 eV.\n\n10. Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.\n\nRC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.\n\n8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).\n\n4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).\n\n11. Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.\n\n12. Analyzer mounting flange: DN-35-CF (2¾\"/70 mm O.D. Conflat-type).\n\n13. Dimensions:\n\nAnalyzer insertion length from mounting flange face: 247 mm.\n\nRF head dimensions: Height – 117 mm, Width – 104 mm, Depth – 195 mm.\n\nDepth is distance from vacuum face of analyzer mounting flange.\n\nRC interface unit dimensions: Height: 90 mm. Width: 19\" rack mounting. Depth: 240 mm.\n\n14. Cable lengths, RC interface to RF head: 40 m.\n\n15. RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included\n\nQuote is for product only; no on-site services permitted.\n\nSource selection will be based on Lowest Price and Technically Acceptable Method (LPTA).\n\nTechnical evaluation criteria are as follows:\n\n1. Mass range: 1–200 atomic mass units (amu)\n\n2. Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.\n\n3. Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.\n\n4. Detector: Twin detector, Faraday cup and Channeltron electron multiplier.\n\n5. Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.\n\n6. Maximum measurement speed: 1000 measurements per second.\n\n7. Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.\n\n8. Filament: Twin filament. Oxide coated iridium.\n\n9. Ion Source control option:\n\nElectron emission: Software variable 1 μA to 2 mA.\n\nElectron energy: Software variable 0 to 150 eV.\n\nIon energy: Software variable 0 to 10 eV.\n\n10. Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.\n\nRC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.\n\n8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).\n\n4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).\n\n11. Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.\n\n12. Analyzer mounting flange: DN-35-CF (2¾\"/70 mm O.D. Conflat-type).\n\n13. Dimensions:\n\nAnalyzer insertion length from mounting flange face: 247 mm.\n\nRF head dimensions: Height – 117 mm, Width – 104 mm, Depth – 195 mm.\n\nDepth is distance from vacuum face of analyzer mounting flange.\n\nRC interface unit dimensions: Height: 90 mm. Width: 19\" rack mounting. Depth: 240 mm.\n\n14. Cable lengths, RC interface to RF head: 40 m.\n\n15. RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included.\n\nPlease provide a price and lead time quotation by 9/19/2023.\n\nSend quote to emezzett@slac.stanford.edu.\n\nThe bid closing date for this requirement is 9/19/2023.\n\nIs there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?\n\nBuy American Act Certification (BAA) applies to awards that are over $10,000.\n\nRepresentations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until\n\nrenewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.\n\nAll subcontractors are required to register in the System for Award Management (www.sam.gov).\n\nIf possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.\n\nThe resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and\n\nConditions for Fixed Price Commercial Supplies and Services (Rev. September 2022) will be made a part of the resulting\n\norder.\n\nPayment Terms will be NET-30\n\nFreight terms will be FOB Destination Prepaid and Add\n\nYou are requested to mark and identify proprietary/confidential information provided in response to the solicitation.\n\nContact me directly with any questions.\n\nKind regards,\n\nEdward Mezzettta\n\nProcurement Commodities Team\n\nSLAC National Accelerator Laboratory\n\n2575 Sand Hill Road\n\nMenlo Park, CA 94025\n\nEmail: emezzett@slac.stanford.edu","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"SLAC_358643_RGA","place_of_performance":{"zip":"94025","city":{"code":"46870","name":"Menlo Park"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"AJ12"}],"due_at":"2025-09-20T00:00:00Z","due_date":"2025-09-19","closes_at":"2025-09-20T00:00:00Z","awardable":true,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-01T02:14:55.543552Z","principal_notice_id":"488c27e3fe744611a1615f6da707c91a","description":{"text":"SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.\n\nRequired item(s) listed below\n\n1. Mass range: 1–200 atomic mass units (amu)\n\n2. Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.\n\n3. Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.\n\n4. Detector: Twin detector, Faraday cup and Channeltron electron multiplier.\n\n5. Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.\n\n6. Maximum measurement speed: 1000 measurements per second.\n\n7. Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.\n\n8. Filament: Twin filament. Oxide coated iridium.\n\n9. Ion Source control option:\n\nElectron emission: Software variable 1 μA to 2 mA.\n\nElectron energy: Software variable 0 to 150 eV.\n\nIon energy: Software variable 0 to 10 eV.\n\n10. Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.\n\nRC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.\n\n8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).\n\n4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).\n\n11. Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.\n\n12. Analyzer mounting flange: DN-35-CF (2¾\"/70 mm O.D. Conflat-type).\n\n13. Dimensions:\n\nAnalyzer insertion length from mounting flange face: 247 mm.\n\nRF head dimensions: Height – 117 mm, Width – 104 mm, Depth – 195 mm.\n\nDepth is distance from vacuum face of analyzer mounting flange.\n\nRC interface unit dimensions: Height: 90 mm. Width: 19\" rack mounting. Depth: 240 mm.\n\n14. Cable lengths, RC interface to RF head: 40 m.\n\n15. RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included\n\nQuote is for product only; no on-site services permitted.\n\nSource selection will be based on Lowest Price and Technically Acceptable Method (LPTA).\n\nTechnical evaluation criteria are as follows:\n\n1. Mass range: 1–200 atomic mass units (amu)\n\n2. Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.\n\n3. Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.\n\n4. Detector: Twin detector, Faraday cup and Channeltron electron multiplier.\n\n5. Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.\n\n6. Maximum measurement speed: 1000 measurements per second.\n\n7. Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.\n\n8. Filament: Twin filament. Oxide coated iridium.\n\n9. Ion Source control option:\n\nElectron emission: Software variable 1 μA to 2 mA.\n\nElectron energy: Software variable 0 to 150 eV.\n\nIon energy: Software variable 0 to 10 eV.\n\n10. Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.\n\nRC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.\n\n8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).\n\n4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).\n\n11. Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.\n\n12. Analyzer mounting flange: DN-35-CF (2¾\"/70 mm O.D. Conflat-type).\n\n13. Dimensions:\n\nAnalyzer insertion length from mounting flange face: 247 mm.\n\nRF head dimensions: Height – 117 mm, Width – 104 mm, Depth – 195 mm.\n\nDepth is distance from vacuum face of analyzer mounting flange.\n\nRC interface unit dimensions: Height: 90 mm. Width: 19\" rack mounting. Depth: 240 mm.\n\n14. Cable lengths, RC interface to RF head: 40 m.\n\n15. RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included.\n\nPlease provide a price and lead time quotation by 9/19/2023.\n\nSend quote to emezzett@slac.stanford.edu.\n\nThe bid closing date for this requirement is 9/19/2023.\n\nIs there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?\n\nBuy American Act Certification (BAA) applies to awards that are over $10,000.\n\nRepresentations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until\n\nrenewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.\n\nAll subcontractors are required to register in the System for Award Management (www.sam.gov).\n\nIf possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.\n\nThe resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and\n\nConditions for Fixed Price Commercial Supplies and Services (Rev. September 2022) will be made a part of the resulting\n\norder.\n\nPayment Terms will be NET-30\n\nFreight terms will be FOB Destination Prepaid and Add\n\nYou are requested to mark and identify proprietary/confidential information provided in response to the solicitation.\n\nContact me directly with any questions.\n\nKind regards,\n\nEdward Mezzettta\n\nProcurement Commodities Team\n\nSLAC National Accelerator Laboratory\n\n2575 Sand Hill Road\n\nMenlo Park, CA 94025\n\nEmail: emezzett@slac.stanford.edu","html":"<p>SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy.&nbsp; As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Required item(s) listed below</strong></p>\n\n<p></p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Mass range: 1&ndash;200 atomic mass units (amu)</p>\n\n<p>2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.</p>\n\n<p>3.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.</p>\n\n<p>4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Detector: Twin detector, Faraday cup and Channeltron electron multiplier.</p>\n\n<p>5.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.</p>\n\n<p>6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum measurement speed: 1000 measurements per second.</p>\n\n<p>7.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.</p>\n\n<p>8.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Filament: Twin filament. Oxide coated iridium.</p>\n\n<p>9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source control option:</p>\n\n<p>Electron emission: Software variable 1 &mu;A to 2 mA.</p>\n\n<p>Electron energy: Software variable 0 to 150 eV.</p>\n\n<p>Ion energy: Software variable 0 to 10 eV.</p>\n\n<p>10.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.</p>\n\n<p>RC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.</p>\n\n<p>8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).</p>\n\n<p>4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).</p>\n\n<p>11.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.</p>\n\n<p>12.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Analyzer mounting flange: DN-35-CF (2&frac34;&quot;/70 mm O.D. Conflat-type).</p>\n\n<p>13.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Dimensions:</p>\n\n<p>Analyzer insertion length from mounting flange face: 247 mm.</p>\n\n<p>RF head dimensions: Height &ndash; 117 mm, Width &ndash; 104 mm, Depth &ndash; 195 mm.</p>\n\n<p>Depth is distance from vacuum face of analyzer mounting flange.</p>\n\n<p>RC interface unit dimensions: Height: 90 mm. Width: 19&quot; rack mounting. Depth: 240 mm.</p>\n\n<p>14.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Cable lengths, RC interface to RF head: 40 m.</p>\n\n<p>15.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included</p>\n\n<p></p>\n\n<p>Quote is for product only; no on-site services permitted.</p>\n\n<p>Source selection will be based on Lowest Price and Technically Acceptable Method (LPTA).</p>\n\n<p></p>\n\n<p><strong>Technical evaluation criteria are as follows:</strong></p>\n\n<p></p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Mass range: 1&ndash;200 atomic mass units (amu)</p>\n\n<p>2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum Operating Pressure:1 x 10-4 mbar with Faraday detector.</p>\n\n<p>3.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Resolution: 10% Valley between adjacent peaks of equal height throughout the mass range. Software adjustable.</p>\n\n<p>4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Detector: Twin detector, Faraday cup and Channeltron electron multiplier.</p>\n\n<p>5.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Minimum Detectable Partial Pressure: 1 x 10-11 mbar with Faraday detector. 1 x 10-15 mbar with Channeltron detector.</p>\n\n<p>6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maximum measurement speed: 1000 measurements per second.</p>\n\n<p>7.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source: Vacuum fired Ion Source. Radially symmetric, UHV compatible ion source.</p>\n\n<p>8.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Filament: Twin filament. Oxide coated iridium.</p>\n\n<p>9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Ion Source control option:</p>\n\n<p>Electron emission: Software variable 1 &mu;A to 2 mA.</p>\n\n<p>Electron energy: Software variable 0 to 150 eV.</p>\n\n<p>Ion energy: Software variable 0 to 10 eV.</p>\n\n<p>10.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN.</p>\n\n<p>RC interface unit I/O; 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.; 3 RS485 (multi protocol) to interface with a wide range of external devices, MFCs for example.</p>\n\n<p>8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).</p>\n\n<p>4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).</p>\n\n<p>11.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Power requirement: 100-240 V AC, 50-60 Hz, 250 VA.</p>\n\n<p>12.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Analyzer mounting flange: DN-35-CF (2&frac34;&quot;/70 mm O.D. Conflat-type).</p>\n\n<p>13.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Dimensions:</p>\n\n<p>Analyzer insertion length from mounting flange face: 247 mm.</p>\n\n<p>RF head dimensions: Height &ndash; 117 mm, Width &ndash; 104 mm, Depth &ndash; 195 mm.</p>\n\n<p>Depth is distance from vacuum face of analyzer mounting flange.</p>\n\n<p>RC interface unit dimensions: Height: 90 mm. Width: 19&quot; rack mounting. Depth: 240 mm.</p>\n\n<p>14.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Cable lengths, RC interface to RF head: 40 m.</p>\n\n<p>15.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; RC interface to PC: Up to 15 meters with RS232 link. Up to 750 meters with unbridged Ethernet link. USB cable, 5 m Ethernet and 5 m RS 232 cables included.</p>\n\n<p></p>\n\n<p>Please provide a price and lead time quotation by 9/19/2023.</p>\n\n<p><strong>Send quote to emezzett@slac.stanford.edu.</strong></p>\n\n<p></p>\n\n<p>The bid closing date for this requirement is 9/19/2023.</p>\n\n<p></p>\n\n<p>Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?</p>\n\n<p></p>\n\n<p><strong>Buy American Act Certification (BAA</strong>) applies to awards that are over $10,000.</p>\n\n<p></p>\n\n<p><strong>Representations &amp; Certifications Rider</strong> is required. Once completed the Reps and Certs is valid for one year until</p>\n\n<p>renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.</p>\n\n<p></p>\n\n<p>All subcontractors are required to register in the System for Award Management (www.sam.gov).</p>\n\n<p>If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.</p>\n\n<p></p>\n\n<p>The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and</p>\n\n<p>Conditions for Fixed Price Commercial Supplies and Services (Rev. September 2022) will be made a part of the resulting</p>\n\n<p>order.</p>\n\n<p></p>\n\n<p>Payment Terms will be NET-30</p>\n\n<p></p>\n\n<p>Freight terms will be FOB Destination Prepaid and Add</p>\n\n<p></p>\n\n<p>You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.</p>\n\n<p>Contact me directly with any questions.</p>\n\n<p></p>\n\n<p>Kind regards,</p>\n\n<p></p>\n\n<p>Edward Mezzettta</p>\n\n<p>Procurement Commodities Team</p>\n\n<p>SLAC National Accelerator Laboratory</p>\n\n<p>2575 Sand Hill Road</p>\n\n<p>Menlo Park, CA 94025</p>\n\n<p>Email: emezzett@slac.stanford.edu</p>","origin":"detail"},"contacts":[{"name":"Katherine Jill A. Coh","role":"primary","email":"kcoh@slac.stanford.edu","phone":"6509262770"}],"place_of_performance":{"zip":"94025","city":{"code":"46870","name":"Menlo Park"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"94025","city":"Menlo Park","state":"CA","country":"USA"},"naics_codes":["3333"],"award":null,"attachments":[{"resource_id":"89813f66e8784418bde3a25dbae9e364","name":"01. BAA_Certification_08.29.2023_(D5) (1).pdf","kind":"file","mime_type":".pdf","size_bytes":583314,"posted_at":"2025-09-04T17:37:14.445Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/89813f66e8784418bde3a25dbae9e364/download","mirrored":false}],"awards":[],"related":[{"key":"SLAC369019DCPOWERSUPPLY","latest_notice_id":"4e4acfada72244b6a547ec75e12df836","title":"DC Power Supply","solicitation_number":"SLAC_369019_DCPowerSupply","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"3333","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"REQ369230","latest_notice_id":"229f30abcc164940aae9b631b004159c","title":"Iris aiOne System","solicitation_number":"Req-369230","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"333310","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"SLACRFP369851AT","latest_notice_id":"c34e1b68f0f94733870a9e11ab9b97ef","title":"SPEAR Beam Position Monitors (BPMs)","solicitation_number":"SLAC_RFP369851_(AT)","notice_type":"o","first_type":"o","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-05T01:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-05T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"334516","psc":"6625","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"SLACNOV2026CHEMICALINVENTORYSYSTEMCIS","latest_notice_id":"ef38bb23d27d497da5149e0735097cf8","title":"SLAC_NOV2026_CHEMICAL_INVENTORY_SYSTEM (CIS)","solicitation_number":"SLAC_NOV2026_CHEMICAL_INVENTORY_SYSTEM_(CIS)","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-19","notices":3,"due_at":"2027-01-09T01:00:00Z","due_date":"2027-01-08","closes_at":"2027-01-09T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"32599","psc":"N068","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"SLAC369019DCPOWERSUPPLY","latest_notice_id":"4e4acfada72244b6a547ec75e12df836","title":"DC Power Supply","solicitation_number":"SLAC_369019_DCPowerSupply","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"3333","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":1,"indexable":false}