Special notice
RTP RASD LAB Notice of Intent to Agilent
RTP_RASDLAB_Notice_of_Intent_to_Agilent
Environmental Protection Agency, Water, Tribal & Science Division. Analytical Laboratory Instrument Manufacturing.
Response deadline
August 20, 2026 at 12:00 PM EDT
Closed 99 days ago. Posted August 14, 2026. Scheduled to archive August 21, 2026.
Get the next one like this from Environmental Protection Agency by email, the day it is posted.Find my opportunities
This one closed in 2026
53 like it are open now in analytical laboratory instrument manufacturing
- PROBE,EDDY CURRENT
Defense Logistics Agency, DLA Aviation
Combined synopsis and solicitationSmall businessNAICS 334516Ship to the buyerSPE4A627T115JDue tomorrowNov 27 - NCSS - Coldhead Exchange Parts and Calibration for
National Institutes of Health, National Institutes of Health Olao
Combined synopsis and solicitationNAICS 334516Ship to the buyer75N98027Q00098Due in 3 daysNov 30 - NOI to Sole Source ESLfemto Laser
Departmental Offices, Ibc Acq SVCS Directorate
PresolicitationNAICS 334516Ship to the buyer140D0426Q0057Due in 4 daysDec 1
All 53 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary
Description
As published on SAM.gov.
Notice of Intent for Sole Source
The Environmental Protection Agency (EPA) in Research Triangle Park (RTP) in Durham, North Carolina intends to award, on a sole source basis, to Agilent in accordance with RFO 6.103-1(b) to purchase one high-performance liquid chromatograph (HPLC) interfaced to a triple quad mass spectrometer (MS/MS) and associated peripherals. This procurement is recommended to be processed without full and open competition.
EPA’s Office of Chemical Safety and Pollution Prevention(OCSPP) Office of Mission Critical Operations, Risk Assessment Support Division’s Laboratory is needing a HPLC to support research that meets OCSPP’s programmatic needs and will replace an aging and outdated instrument utilized exclusively for EDSP assays (eg., steroid and thyroid hormone assays) while simultaneously enhancing high-throughput capabilities for in-vitro screening assays within EDSP and other data requests. This equipment is vital for high-throughput assay automation to generate data for many aspects of OCSPP’s mission to gain knowledge about chemicals and their associated effects on human health and the environment. Agilent-manufactured instruments include unique specifications that are required to conduct the specific assays integral to OCSPP’s work, these instruments include technology that is proprietary to Agilent. These instruments are directly compatible with existing Government-owned Agilent hardware and software in order to continue performance of previously developed assays without interruption
The itemized required elements of acquisition are:
- 6495C Instrument #1 (Options listed below) —
- G6495CAR – Certified Pre-owned 6495C Triple Quadrupole LC/MS System. Includes: 6495 LC/TQ, PC, installation and introduction, and 1Y SW upgrade/phone.
- M5930AA – MassHunter Workstation Software for LC/TQ. Includes installation software and user license for non-workstation system
- G2255-68700 – Vial plate for 54x2ml vials, 6/pk
- SYS-LM-6495 – LCMS 6495 iFunnel QQQ - Ship-to Country - USA Enhanced Ext.Wty -Govt/Acad -3yrs Total
- G1191AR – Certified Pre-owned 1290 Infinity II HPLC System, including high speed pump with integrated degasser, diode array detector, multi-column thermostat with valve drive, and multisampler with thermostat.
- 3 Year Full System Warranty
- 6495C Instrument #2: High-throughput w/ StreamSelect —
- M5930AA – MassHunter Workstation Software for LC/TQ. Includes installation software and user license for non-workstation system
- G4936CA – CTC PAL3 Series II RSI LC injector with LC/MS tool, PAL injector valve (up to 1300 bar) and valve drive kit for 2-stream StreamSelect system. Installation service is included.
- G7120A – 1290 Infinity III High Speed Pump. Power range1300 bar and 5ml/min flow, binary high pressure mixing, lowest delay, highest precision and accuracy. Includes Active Seal Wash, Tool Kit, Solvent Cabinet, bottles and ISET.
- G7116B – 1290 Infinity III Multicolumn Thermostat. Capacity up to 8 columns, temperature range 4 deg C. to 110 deg C. Includes 1.6uL Quick-Connect Heat Exchanger, Quick-Connect fitting and two Quick-Turn fittings. Valve drive optional.
- 5068-0034 – 50 ul Capillary Loop (SST)
- 5023-0202 – Patch Cable Shielded 7M
- G1969-85026 – HPLC Flushing Solvent - 500 mL
- 5022-2184 – Union, stand LC flow, no fitting
- 5063-6598 – Tefzel ferrules/SS rings, 1/8 in 10/PK
- 5063-6599 – PPS nuts, 1/8 in, 1/4-28 thread 10/PK
- 5062-2483 – Solvent tubing, 5m, 1.5mm id, 3mm od Solvent tubing 5m
- 01018-60025 – Solvent inlet filter, stainless steel Solvent inlet filter, stainless steel for external channel only.
- G6075A – StreamSelect System Bench
- G6495CAR – Certified Pre-owned 6495C Triple Quadrupole LC/MS System. Includes: 6495 LC/TQ, PC, installation and introduction, and 1Y SW upgrade/phone.
- SYS-LM-6495-X – LCMS 6495 iFunnel QQQ Advanced Functions. Ship-to Country - USA Enhanced Ext.Wty -Govt/Acad -3yrs Total
- 3 Year Full System Warranty
- (OTHER - BELOW) —
- H2149A – Training: Method and Application Consulting On-site consulting for a maximum of 4 participants. Certificates and manuals not included.
- Schematics and Wiring Diagrams (upon request).
This Notice of Intent is not a request for proposals. This notice of intent is for information purposes only; therefore, no solicitation will result from this announcement.
All capability statements received within 5 days after publication of this notice will be considered by the Government. Responses must be supported with clear and convincing evidence to clearly be able to provide the services outlined and itemized pricing that is sufficient to make a determination that competition is feasible. A request for documentation will not be considered as an affirmative response. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Contracting Officer. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement.
Submit questions or concerns via email (using PDF, MS Word, Excel attachments) to Contract Specialist, Jeremy Melby, at melby.jeremy@epa.gov. No telephone calls will be accepted.
The NAICS code for this procurement is: 334516 - Analytical Laboratory Instrument Manufacturing
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Notice of Intent for Sole Source (003).pdf445 KB, August 14, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
August 14, 2026
Special notice
Due August 20, 2026 at 12:00 PM EDT. SAM.gov, notice 3528298dce75476693fad9fe0ed13463
1 revision on SAM
- August 14, 2026: publish, special notice
Points of contact
- Melby, Jeremymelby.jeremy@epa.gov9195410314