Combined synopsis and solicitation
Agilent 6560 Ion Mobility LC/Q-TOF System Upgrade
RFQ25Q1285887
Food and Drug Administration, FDA Office of Acq Grant SVCS. Analytical Laboratory Instrument Manufacturing.
Response deadline
June 23, 2025 at 10:00 AM EDT
Closed 521 days ago. Posted June 23, 2025, first published June 13, 2025. Scheduled to archive July 8, 2025.
Get the next one like this from Food and Drug Administration by email, the day it is posted.Find my opportunities
This one closed in 2025
53 like it are open now in analytical laboratory instrument manufacturing
- Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due tomorrowNov 27 - Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology, Department of Commerce NIST
Sources soughtNAICS 334516Ship to Gaithersburg, MDNIST-MML-FY27-SS01Due in 2 daysNov 28 - Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
Department of the Army, W6QK ACC-APG Adelphi
SolicitationNAICS 334516Ship to MDW911QX27QA015Due in 5 daysDec 1
All 53 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 10 days from the day the solicitation was posted, June 13, 2025, to the deadline. The deadline moved 3 times: it was first June 23, 2025 and ended as June 23, 2025.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Background
DPQR is requesting a suite of hardware and software updates to our Agilent 6560B ion mobility high resolution quadrupole time-of-flight mass spectrometer (IM-QTOF) platform to address the increasing regulatory research needs and sample testing requests for the evaluation of complex pharmaceutical drug products, e.g. complex generics, biosimilars, and emerging drug entities. Mass spectrometry is a tool for measuring molecular mass information of various types of drug products: small molecules, peptides, proteins, oligonucleotides, etc. Recent advances of integrating ion mobility with mass spectrometry provides additional information regarding the analytes’ gas phase collision cross section (CCS) which can be used to infer various structural information of the analyte as well as possible isomer identification. Advanced ion mobility techniques such as collision-induced unfolding (CIU) can be further used to monitor the conformational dynamics of biomolecules and gain insight into their higher-order structure (HOS). The regulatory evaluation from the perspectives of product characterization, quality control, and sameness or similarity assessment for complex pharmaceutical products has always been challenging due to their complex structure and/or impurity profile. It is critical that the FDA laboratories have the facility and capability to fully characterize the complex drug products which helps address the regulatory inquires and concerns during the review process. Currently, DPQR has an instrument platform consisting of an Agilent 6560B IM-QTOF system connected to an Agilent RapidFire 365 robotic sampling platform. We aim to upgrade the current platform by incorporating a CIU activation cell to our 6560 system and a biologic compatible high performance liquid chromatography system, enabling advanced separation prior to mass spectrometry analysis, through a hardware upgrade as well as software upgrade for interpreting advanced ion mobility mass spectrometry data. This platform will advance DPQR’s analytical capability and research readiness to generate critical evidence to support both new, generic, and biosimilar drug applications.
Scope
To obtain a software and hardware upgrade to the existing Agilent 6560B IM-QTOP System
Requirement
Contractor shall provide the following salient characteristics to the Agilent 6560B IM-QTOP upgrade:
Item 1: Instrument
-A hardware upgrade to the Agilent 6560B IM-QTOF instrument allowing for collision-induced unfolding (CIU) capabilities for ions, such as antibodies (MW 150 kDa), from native to their extended conformation states. This upgrade should be fully compatible, both hardware and software, to existing Agilent 6560B platform instrumentation and should not introduce any detriment to instrument capacity.
-An ultra performance liquid chromatography (UPLC) system that is biocompatible, have a binary system (1300bar), thermally controlled multiplate sampler (4 C to 40 C) and column compartment (4 C to 60 C), variable wavelength detector, and flex bench mobile cart for easy movement. This UPLC system must be fully compatible, both hardware and software, to existing Agilent 6560B platform instrumentation and easy to swap in/out with the currently linked Agilent RapidFire 365 system.
-Required source ion optic hardware needed for analysis of peptide, proteins, antibodies, and oligonucleotides.
Item 2: Software
-Software that is compatible with data generated from the upgraded Agilent 6560B and purchased UPLC system to allow for data/library management, targeted/non-targeted analysis, peptide/protein analysis, oligonucleotide analysis, compound discovery, etc.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Combined Synopsis for Aligent 1290.pdf463 KB, June 13, 2025
- Combined Sysnopsis Upgrade to Agilent 6580B IM-QTOP system.pdf399 KB, June 23, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 13, 2025
Combined synopsis and solicitation
Due June 23, 2025 at 10:00 AM EDT. SAM.gov, notice 4bb19354972f454b846564910cb2ab23
4 revisions on SAM
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 13, 2025: publish, combined synopsis and solicitation
June 23, 2025
Combined synopsis and solicitation
Due June 25, 2025 at 10:00 AM EDT. SAM.gov, notice 013970ac56f24f0e847f0b0d57c69dfa
4 revisions on SAM
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 13, 2025: publish, combined synopsis and solicitation
June 23, 2025
Combined synopsis and solicitation
Due June 27, 2025 at 10:00 AM EDT. SAM.gov, notice 477a9b07ce664b7c8640c5e5003cdb01
4 revisions on SAM
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 13, 2025: publish, combined synopsis and solicitation
June 23, 2025
Combined synopsis and solicitation
Due June 23, 2025 at 10:00 AM EDT. SAM.gov, notice e5127f8e7b564851b2d144eb5d8118c1
4 revisions on SAM
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 23, 2025: publish, combined synopsis and solicitation
- June 13, 2025: publish, combined synopsis and solicitation
Points of contact
- Warren Jacksonwarren.jackson@fda.hhs.gov3018377147