Combined synopsis and solicitation
Agilent Infinity II 1290 or Equivalent
RFQ25Q1284011
Food and Drug Administration, FDA Office of Acq Grant SVCS. Analytical Laboratory Instrument Manufacturing.
Response deadline
June 23, 2025 at 10:00 AM EDT
Closed 521 days ago. Posted June 13, 2025, first published June 11, 2025. Scheduled to archive July 8, 2025.
Get the next one like this from Food and Drug Administration by email, the day it is posted.Find my opportunities
This one closed in 2025
53 like it are open now in analytical laboratory instrument manufacturing
- NANO-AEROSOL HYGROSCOPICITY- CLOUD CONDENSATION ANALYZER
Department of the Air Force, FA8601 AFLCMC Pzio
Sources soughtNAICS 334516Ship to Wright-Patterson AFB, OHFA860127Q0031Due tomorrowNov 27 - Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due tomorrowNov 27 - Mechanical Components
National Aeronautics and Space Administration, NASA Shared Services Center
Combined synopsis and solicitationNAICS 334516Ship to MS80NSSC27949537QDue tomorrowNov 27
All 53 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 12 days from the day the solicitation was posted, June 11, 2025, to the deadline. The deadline moved once: it was first June 18, 2025 and ended as June 23, 2025.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
- Background
The Office of Pharmaceutical Quality Research (OPQR), part of CDER’s super Office of Pharmaceutical Quality, protects the public health by assuring the quality and availability of drugs and biologics by conducting mission-relevant research that addresses current and future needs to support: Science- and risk-based quality assessments of regulatory submissions; Standard, guidance, and policy development; Pharmaceutical quality surveillance, and Rapid responses to public health issues. The acquisition 1290 Infinity II LC System with ELSD will provide a robust high-performance liquid chromatography instrument suitable for a wide range of analytical applications.
-
- Scope
To obtain an Agilent 1290 Infinity II LC System with DAD and ELSD or equivalent for use in DPQR- STL.
-
- Requirement
The contractor shall provide (1) Agilent 1290 II LC System with DAD and ELSD or equivalent with the following salient characteristics:
- The Ultra-High Performance Liquid Chromatograph shall comply with the following quality requirements:
- ISO/IEC 17025-2017 https://www.iso.org/standard/39883.html, https://www.iso.org/standard/66912.html
- ISO 9001:2008 https://www.iso.org/standard/46486.html
- 21 CFR Part 11 Compliance https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/cfrsearch.cfm
- USP, cGMP/cGLP
https://login.usp.org/cas/login?service=http%3A%2F%2Fonline.uspnf.com%2Fcas%2Flogin
- High Speed Pump
- Settable flow range: Setpoints 0.001—5 ml/min, in 0.001 ml/min increments
- Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min)
- Active Seal Wash: Included with sensor
- Flow accuracy: 1 <±1.0 %
- Multisampler
- Maximum load of 16 microplates and up to 6,144 samples for unmatched sample capacity
- Integrated sample thermostat
- Multi-wash capability.
- Dual needle injection
- Column Compartment
- Compartment capacity up to 8 columns
- Column Compartment Temperature Range 4 °C to 110 °C
- Heat Exchanger
- Column Tracing
- Diode Array Detector
- RFID technology for flow cells
- Simultaneous detection of up to eight signals for increased sensitivity and selectivity
- Less baseline drift for more reliable and robust peak integration
- Pressure Range up to 1300 bar (18,855 psi)
- Full Audit Trail Capabilities
- Inside Delivery
- Installation, instrument configuration, and operational qualification
- Familiarization Training for 3-5 users
Trade and Service Specs
- Equipment shall be newly manufactured, not used, refurbished, or previously used for demonstration.
- The Contractor shall provide a minimum of a one-year manufacturing warranty for all manufactured equipment and parts. The warranty shall be included with the equipment and not separately priced. The warranty shall include at a minimum: coverage on all non-consumable items and parts supplied including base instrument, factory-certified replacement parts, engineer labor and travel costs. Any equipment repair and maintenance work shall be performed by an OEM-trained engineer. This factory-trained engineer shall have (verified by the OEM) the following: 1) access to OEM factory telephone support; 2) access to the most current OEM factory training for both hardware and software components; and 3) access to all current OEM factory parts, not build-to-order parts. The OEM-trained service engineer shall not use salvaged parts from other instruments for performing maintenance and repairs. All parts used in PM and repairs must be guaranteed, factory-tested, OEM quality parts.
- Instrument operators shall have access to a technical representative call center at no additional charge, for technical assistance and troubleshooting, which is staffed by senior engineers to provide a high level of expertise for troubleshooting the instrument.
- The Contractor shall provide training and validation of the equipment and software on site at the time of installation. Sufficient familiarization training for 3-5 users per delivery onsite location will be provided, such that operators may independently operate the instrument and with increased familiarity and proficiency. The training shall include manuals and any consumables to be used during training.
- The Contractor shall provide installation qualification with an employee who can provide proof of installation qualification/operation qualification (IQ/OQ) certification. The qualification and verification report shall include the standard operating procedures and the allowed manufacturer limits for the instrument. A copy of the calibration report and the qualification and verification report(s) shall be reviewed and approved by an FDA representative before installation of the equipment and execution of protocols.
- Inside delivery, disposing pallets, boxes, and any associated garbage, and unpacking the equipment and inventory of parts with a lab representative.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Combined Synopsis for Aligent 1290.pdf463 KB, June 11, 2025
- Combined Synopsis for Aligent Infinity II 1290.pdf463 KB, June 13, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 11, 2025
Combined synopsis and solicitation
Due June 18, 2025 at 10:00 AM EDT. SAM.gov, notice 93e2cebb0a344db495c05103d392537c
2 revisions on SAM
- June 13, 2025: publish, combined synopsis and solicitation
- June 11, 2025: publish, combined synopsis and solicitation
June 13, 2025
Combined synopsis and solicitation
Due June 23, 2025 at 10:00 AM EDT. SAM.gov, notice d2ffb3901f05446d9a151e4d47dff601
2 revisions on SAM
- June 13, 2025: publish, combined synopsis and solicitation
- June 11, 2025: publish, combined synopsis and solicitation
Points of contact
- Warren Jacksonwarren.jackson@fda.hhs.gov3018377147