# Multi -Roof Replacement Project

Canonical: https://sealedbidder.com/opportunities/rfp26021r

- Solicitation number: RFP26-021R
- Notice type: Solicitation
- Status: Closed. Deadline was February 27, 2026 at 4:00 PM EST
- Department: Department of Energy
- Contracting office: Princeton Lab - DOE Contractor (899035)
- NAICS: 236220 Commercial and Institutional Building Construction
- Product or service code: Y1EZ Construction Of Other Industrial Buildings
- Small business size standard: $45 million in average annual receipts (13 CFR 121.201, NAICS 236220)
- Place of performance: Princeton, New Jersey
- County: Mercer County (FIPS 34021). https://sealedbidder.com/counties/mercer-county-nj-34021
- City: Princeton. https://sealedbidder.com/cities/princeton-nj-3460900
- First posted: January 27, 2026
- Last posted: January 28, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/8de1da092b6343039e06f3f23d7df974/view

## Reading this notice

- Kind of notice: Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline.
- Who may compete: SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates.
- Time to respond: Bidders had 31 days from the day the solicitation was posted, January 27, 2026, to the deadline. The deadline moved once: it was first February 24, 2026 and ended as February 27, 2026.

## Description

There are several existing roofs (C50 ESAT Building/C52 PLT Power Building/C60 C Site Pump

House/D45 Rad Waste Handling Facility) which are past their useful life requiring costly

maintenance to upkeep. Severe water infiltration occurs regularly at failing joints, punctures,

and flashing. Portions of existing metal coping have pulled away during storm events causing

large sections of membrane to separate from the substrate. A catastrophic failure to one of

these roofs would negatively impact the ability to conduct the top priority experimental

operations in the Laboratory.

1.2. SCOPE

1.2.1. The Subcontractor shall provide all materials, labor, supervision, equipment, and expertise

required replace the noted roofs and specified components per the associated contract

documents. Construction scope includes the following:

1.2.1.1. Remove and replace existing built-up roofs at PPPL. Buildings include:

1.2.1.1.1. C50 &ndash; ESAT Building

1.2.1.1.2. C52 &ndash; PLT Power Building

1.2.1.1.3. C60 &ndash; C Site Pump House

1.2.1.1.4. D45 &ndash; Rad Waste Handling Facility

1.2.1.2. Demolition including removal of existing membrane, cover board, insulation, metal trim,

flashing, coping and any other miscellaneous roofing material accessories.

1.2.1.3. Remove and recycle stone ballast on ballasted roofs. Recycle documentation to be

provided to PPPL.

1.2.1.4. Additional integrated roof elements shall be inspected and replaced as specified within

this SOW. Elements include: wood blocking, roof drains, gutters, scuppers, downspouts,

and metal/concrete roof panels.

1.2.1.5. Abandoned equipment shall be removed to a point that does not affect new roof

installation. Any equipment that should be temporarily relocated so roof replacement

work can be completed shall be the responsibility of the roofing contractor.

1.2.1.6. Contractor to furnish and install 2 layers of 2.6&rdquo; ISO.

1.2.1.7. Contractor to furnish and install &frac12;&rdquo; HD coverboard mechanically fastened.

1.2.1.8. Contractor to furnish and install 145 mil Carlisle Fleeceback EPDM, black in color adhered

to coverboard.

1.2.1.9. Contractor to furnish and install counter flashing and copings, expansion joints and other

roofing components as required for manufacturer&rsquo;s warranty.

Page 3 of 21

1.2.1.10. The new roof system shall be comprised of the following materials: EPDM membrane,

cover board, and insulation.

1.2.1.10.1. Meets a minimum insulating value of R-30 average. Modifications to the existing

building envelope are required to accommodate additional insulation.

1.2.1.10.2. Flexible walkway pads shall be provided to all operating equipment/drain locations

and as necessary to meet manufacturer&rsquo;s requirements.

1.2.1.10.3. All materials shall be furnished by Carlisle Syntec Systems and shall meet all

manufacturer specifications to obtain a minimum manufacturer system warranty of

30 years along with a 2-year installers warranty. The warranty coverage shall

include incidental membrane punctures, damage from hail and a minimum of 72-

mph peak gust wind speeds.

1.2.1.11. Roof perimeter guardrails shall be provided on all roofs. See attached guardrail cut sheet

for details.

1.2.1.12. New and higher curbs as required due to the new roof installation work.

1.2.1.13. Contractor to build up existing roof vents as required due to the new roof work.

1.2.1.14. Expansion joint to be raised up to account for new roof insulation height for the ESAT

building roof.

1.2.1.15. Contractor to add a new roof drain at the Northwest section of the ESAT building roof.

1.2.1.16. Contractor to replace all existing roof scuppers with new.

1.2.1.17. Contractor to replace all existing roof drains with new.

1.2.1.18. Contractor to provide minimum of 12&rdquo; overlap between the existing adjacent roof

membrane system and provide written confirmation the systems are compatible.

1.2.1.19. Contractor to temporary relocate and reinstall any fall protection anchor systems

identified on roof sections.

1.2.1.20. Contractor to install secondary drainage per code in addition to existing drains for the PLT

building roof.

1.2.1.21. If necessary, existing asbestos elements shall be mitigated by PPPL. Subcontractor to

assist the abatement contractor to bring the sealed roofing material down from roof area

to grade with lift equipment. Coordination of this work shall be completed in concert with

all other construction activities. The subcontractor to follow directly after PPPL

abatement contractor to install new roofing system. The construction subcontractor shall

be responsible to coordinate all work with PPPL.

1.2.1.22. Any and all equipment that requires power disconnect has to be coordinated with PPPL a

minimum of 72 hours prior. All equipment that will be out of service shall be minimized.

1.2.1.23. All roof fans and equipment are to be salvaged, protected, and reinstalled.

THERE ARE (5) COVER LETTER SECTIONS TO THE RFP.  THERE ARE FILES ATTACHED TO EACH COVER LETTER.  TO VIEW THE ATTACHMENTS YOU MUST

(1) FIRST DOWNLOAD EACH COVER LETTER SECTION TO YOUR DESKTOP.

(2) AFTER DOWNLOADING EACH COVER LETTER--REOPENED EACH ONE (ON YOUR DESKTOP)

YOU SHOULD BE ABLE TO SEE THE ATTACHED FILES ON THE RIGHT HAND SIDE OF THE COMPUTER SCREEN.   BE SURE TO UTILIZE ADOBE ACROBAT SOFTWARE TO VIEW THE PDF FILES

## Attachments

- [SOW_C50-C52-C60-D45 Roof Replacement Work.pdf](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/11c0bd3303af4e7fbbaa285acb98e652/download)

## Open now in the same industry

194 open in NAICS 236220.

- 561-26-103 Upgrade Electrical and Plumbing in Building 18B (36C24227B0003_1), due December 14, 2026 at 11:00 AM EST. https://sealedbidder.com/opportunities/36c24227b00031
- P233 AIR TRAFFIC CONTROL TOWER AND FLIGHT SIMULATOR TRAINING FACILITY (N6945027RP233), due November 25, 2026 at 11:00 AM EST. https://sealedbidder.com/opportunities/n6945027rp233
- Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information (36C26027R0002-0006), due November 25, 2026 at 12:00 PM EST. https://sealedbidder.com/opportunities/36c26027r00020006

## Publications

- January 27, 2026: Solicitation, due February 24, 2026 at 4:00 PM EST. Notice d5d5914d879e4bd69a9bc1f628a3d4e8. https://sam.gov/workspace/contract/opp/d5d5914d879e4bd69a9bc1f628a3d4e8/view
- January 28, 2026: Solicitation, due February 27, 2026 at 4:00 PM EST. Notice 8de1da092b6343039e06f3f23d7df974. https://sam.gov/workspace/contract/opp/8de1da092b6343039e06f3f23d7df974/view

## Points of contact

- Jimmy Russell, jrussell@pppl.gov, 6092433963

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/rfp26021r.