Solicitation
Environmental Chamber
PR329505
Department of Energy, ORNL Ut-Battelle LLC-DOE Contractor. Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing.
Response deadline
December 19, 2024 at 2:00 PM EST
Closed 706 days ago. Posted November 26, 2024. Scheduled to archive January 3, 2025.
Get the next one like this from Department of Energy by email, the day it is posted.Find my opportunities
This one closed in 2024
25 like it are open now in air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing
- FILTER ELEMENT,AIR CON
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationSmall businessNAICS 333415Ship to the buyerSPE8E827Q0072Due tomorrowNov 25 - POWER,BREEZER
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationSmall businessNAICS 333415Ship to the buyerSPE8E727Q0025Due tomorrowNov 25 - FILTER ELEMENT,AIR CON
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationSmall businessNAICS 333415Ship to the buyerSPE8E827Q0071Due tomorrowNov 25
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 333415 (air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing), means no more than 1,250 employees, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 23 days from the day the solicitation was posted, November 26, 2024, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Environmental Chamber Company requires the design and installation of a 60,000 to 300,000 Btu/h automated air enthalpy chamber. For the operation of this apparatus, the upper chamber will be operated over an ambient temperature range of -32 to 66°C (-25 to 150°F) and the lower chamber must simulate a wide range of indoor temperatures from 7 to 66°C (45 to 150°F). The chamber is to be a stacked configuration with an overall height of 26 feet with the upper chamber 14 feet tall and the lower chamber 12 feet tall.
The floor area for both upper and lower chambers is to be 22 feet by 22 feet. The facility shall conform to the instruments and test requirements and provide the conditions specified in the attached document. The facility will use either the Outdoor Air Enthalpy or the Refrigerant Enthalpy method as the Standard Test Method secondary check to the performance results as prescribed in ASHRAE 37. Airflow tunnels (code testers) should be supplied for both chamber rooms.
The code testers should be integrated with the automated end-to-end DAS and provide required level of accuracy, ease of use and reliability. The code testers shall be designed and constructed in accordance with ASHRAE 37 by the Seller. See attached: "Environmental Chamber Combined Docs" for further details.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
November 26, 2024
Solicitation
Due December 19, 2024 at 2:00 PM EST. SAM.gov, notice eae67be81fc2462ebe84673707f41c54
Points of contact
- Laura HydenHydenln@ornl.gov865-341-4201