Combined synopsis and solicitation
SCBA Breathing-Air Compressor and Fill Station System
PCA-ORS-08834
National Institutes of Health, National Institutes of Health Nhlbi. Air and Gas Compressor Manufacturing.
Awarded
$154,995.00 obligated so far on USAspending
Get the next one like this from National Institutes of Health by email, the day it is posted.Find my opportunities
This one was awarded in 2026
28 like it are open now in air and gas compressor manufacturing
- Service Air System Revitalization
Department of the Air Force, FA9101 Aedc PKP Procrmnt BR
Sources soughtNAICS 333912Ship to TNFA9101_Service_Air_System_RevitalizationDue todayNov 25 - PARTS KIT,COMPRESSOR 4310-01-480-5743
Defense Logistics Agency, DLA Weapons Support
Sources soughtNAICS 333912Ship to San Diego, CASPE7M127R0008Due todayNov 25 - COMPRESSOR UNIT
Department of the Army, W6QK ACC-RSA
SolicitationNAICS 333912Ship to Fort Bliss, TXW31P4Q27RA010Due tomorrowNov 26
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 333912 (air and gas compressor manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 4 days from the day the solicitation was posted, September 21, 2026, to the deadline.
- How it ended
- Awarded to Delray Industries LLC on September 29, 2026, 4 days after offers were due. The contracting office reported 22 offers (competed under simplified acquisition procedures).
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
COMBINED SYNOPSIS/SOLICITATION (BRAND-NAME)
SCBA Breathing-Air Compressor and Fill Station System
Agency: Department of Health and Human Services (HHS) Sub-Agency: National Institutes of Health (NIH), Office of Research Services (ORS), Division of Fire and Rescue Services
Classification / NAICS Code: 333912 – Air and Gas Compressor Manufacturing Product Service Code (PSC): 4310 – Compressors and Vacuum Pumps
Solicitation / RFQ Number: PCA-ORS-08834
Notice Type
This is a combined synopsis/solicitation for a commercial product prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information in this notice. This announcement constitutes the only solicitation; quotations are being requested and a separate written solicitation will not be issued.
This requirement is being conducted as a Simplified Acquisition under FAR Part 13 and as a commercial acquisition under FAR Part 12. This is a brand-name requirement. All responsible sources capable of supplying the specified brand-name item, including authorized dealers, may submit a quotation that will be considered by the Government.
Description of Requirement
The NIH Division of Fire and Rescue Services requires a fully integrated breathing-air compressor and SCBA fill station capable of safely and efficiently filling SCBA cylinders used in emergency response, hazardous materials operations, technical rescue incidents, and firefighter training. The system must support continuous operational readiness, minimize operator error, provide automated fill management, and maintain electronic records required for respiratory protection and equipment management programs.
The required item is the BAUER UNICUS® 4i-18-E3 (or the specific configuration described below), including delivery, installation, commissioning, and operator training.
Brand-Name Justification
This requirement is restricted to the BAUER UNICUS® 4i brand-name configuration. Based on market research, the BAUER UNICUS® 4i integrates the following required capabilities within a single factory-engineered platform:
- Fully automated SCBA filling – automatically identifies allowable cylinder fill pressures and fills to maximum rated pressure without manual valve manipulation, reducing operator error.
- Automatic cascade management – solid-state automatic cascade system that optimizes storage-bank utilization and fill sequencing.
- Integrated RFID tracking and compliance documentation – records cylinder identification, fill history, operator information, fill pressures, and hydrostatic test/expiration dates; prevents filling expired cylinders and generates permanent electronic records supporting NFPA 1989 and OSHA documentation requirements.
- NFPA-compliant three-position containment fill station – allows simultaneous filling of multiple cylinders while protecting personnel from catastrophic cylinder failure.
- Single integrated system – combines compressor, purification, storage, cascade controls, RFID management, and containment fill station in one package, reducing installation complexity, maintenance, training burden, and lifecycle cost.
- Operational readiness/safety – 18.0 SCFM output at 6000 PSI, with manual bypass capability during power outages for emergency continuity.
The full justification is documented in the Brand-Name Justification signed by the Assistant Fire Chief, NIH Fire Department, and is available upon request.
Salient Characteristics / Configuration
The quoted system shall include, at minimum:
- UNICUS 4i, four-cylinder recharging station; 18 SCFM charging rate; 6000 PSI; three-phase electric (208V, 3-phase, 60 Hz available at the site)
- BAUER breathing-air purification system
- Solid-state automatic cascade system
- RFID reader/management with cloud service
- Three-position NFPA-compliant containment fill station (accommodating cylinders up to 31" overall length)
- Four (4) ASME-rated storage cylinders
- Electronic CO monitor with shutdown
- Remote fill panel/hose connection (regulator, gauge, isolation valve, hose reel with hose) to support remote filling of the HazMat unit cascade system
- Manual bypass capability for power-outage operation
Included Services
- Delivery to NIH, Building 51, Bethesda, MD
- Freight, startup, air testing, and one operator training session
- Installation and commissioning
(Offerors shall state clearly what installation/electrical scope is and is not included in their quote.)
Place of Performance
NIH, Building 51, Bethesda, MD 20892.
Schedule / Period of Performance
- Delivery: approximately 6–8 weeks after receipt of order (state firm lead time in quote)
- Installation and commissioning: within 2 weeks after delivery
- Total period of performance not to exceed 90 calendar days from award
Basis for Award
Award will be made to the responsible offeror whose quotation conforms to the brand-name requirement and represents the best value / lowest price technically acceptable to the Government. [Confirm evaluation approach — LPTA vs. best value.]
Applicable Provisions and Clauses
- FAR 52.212-1 – Instructions to Offerors—Commercial Products and Commercial Services
- FAR 52.212-2 – Evaluation—Commercial Products and Commercial Services [insert evaluation factors]
- FAR 52.212-4 – Contract Terms and Conditions—Commercial Products and Commercial Services
- FAR 52.212-5 – Contract Terms and Conditions Required to Implement Statutes or Executive Orders
Offerors shall include a completed copy of FAR 52.212-3, Offeror Representations and Certifications, or confirm active SAM registration with representations and certifications completed. Quotations shall include the offeror's UEI.
Response Due Date
Quotations are due no later than September 25, 2026, 3:00 PM ET.
Submission Instructions
Quotations shall be submitted by email to the Contracting POC below. Vendors are responsible for confirming receipt.
Point of Contact
Contracting Officer / Specialist: Travis Brown Email: travis.brown@nih.gov
This notice will be posted at SAM.gov (sam.gov) in accordance with FAR Part 5. The Government reserves the right to make award without discussions. This notice does not obligate the Government to award a contract or pay any costs incurred in the preparation of a response.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Delray Industries LLC
- UEI
- XM6GWU81SKN8
- CAGE
- 7T1Z7
- Vendor location
- Winchester, VA
- Contract
- 75N98026P01923, purchase order
- Obligated
- $154,995.00
- Actions
- 1 between September 29, 2026 and September 29, 2026
- Competition
- Competed Under SAP, 22 offers received
- Set-aside reported
- No Set Aside Used.
- Described as
- Scba Breathing-Air Compressor and Fill Station System
- Match
- solicitation number PCAORS08834 equals the FPDS solicitation identifier; same sub-agency 7529 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
September 21, 2026
Combined synopsis and solicitation
Due September 25, 2026 at 3:00 PM EDT. SAM.gov, notice bbafc89166324fa3ba794bd7ee368566
1 revision on SAM
- September 21, 2026: publish, combined synopsis and solicitation
Points of contact
- R. Travis Browntravis.brown@nih.gov