{"canonical":"https://sealedbidder.com/opportunities/panrsa26p0000033738","key":"PANRSA26P0000033738","url":"https://sealedbidder.com/opportunities/panrsa26p0000033738","title":"Lab Microphone System","solicitation_number":"PANRSA-26-P-0000-033738","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-14T15:00:00Z","first_posted":"2026-03-09","last_posted":"2026-10-13","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QK ACC-RSA","naics":"334310","psc":"5965","set_aside":"SBA","place_state":"AL","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"01089","place_county_name":"Madison County","place_city":"0163912","place_city_name":"Redstone Arsenal","winner":"GFS SUPPLY & SERVICES COMPANY, INC.","award_amount":"35888.40","publications":[{"notice_id":"4a52cefe29534e7f99be1a704e54d095","title":"Lab Standard Microphone System","solicitation_number":"PANRSA-26-P-0000-033738","notice_type":"s","base_type":"s","posted":"2026-03-09","posted_at":"2026-03-09T18:01:10.979Z","due_at":"2026-03-18T21:00:00Z","due_date":"2026-03-18","cancelled":false,"archived":true,"archive_date":"2026-04-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4a52cefe29534e7f99be1a704e54d095/view","enriched":true,"history":[{"index":3,"title":"Lab Standard Microphone System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T15:30:50.362Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"1c6d967af342496f9cb7fd7f99032aff","solicitation_number":"PANRSA-26-P-0000-033738","parent_opportunity_id":"4a52cefe29534e7f99be1a704e54d095"},{"index":1,"title":"Lab Standard Microphone System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-09T18:01:10.979Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"4a52cefe29534e7f99be1a704e54d095","solicitation_number":"PANRSA-26-P-0000-033738"}]},{"notice_id":"1c6d967af342496f9cb7fd7f99032aff","title":"Lab Standard Microphone System","solicitation_number":"PANRSA-26-P-0000-033738","notice_type":"s","base_type":"s","posted":"2026-03-26","posted_at":"2026-03-26T15:30:50.362Z","due_at":"2026-04-02T21:00:00Z","due_date":"2026-04-02","cancelled":false,"archived":true,"archive_date":"2026-04-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1c6d967af342496f9cb7fd7f99032aff/view","enriched":true,"history":[{"index":3,"title":"Lab Standard Microphone System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T15:30:50.362Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"1c6d967af342496f9cb7fd7f99032aff","solicitation_number":"PANRSA-26-P-0000-033738","parent_opportunity_id":"4a52cefe29534e7f99be1a704e54d095"},{"index":1,"title":"Lab Standard Microphone System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-09T18:01:10.979Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"4a52cefe29534e7f99be1a704e54d095","solicitation_number":"PANRSA-26-P-0000-033738"}]},{"notice_id":"0d0e838f8655416295148c385a3983c5","title":"Lab Microphone System","solicitation_number":"PANRSA-26-P-0000-033738","notice_type":"o","base_type":"o","posted":"2026-06-30","posted_at":"2026-06-30T13:36:00.993Z","due_at":"2026-07-14T15:00:00Z","due_date":"2026-07-14","cancelled":false,"archived":true,"archive_date":"2026-07-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0d0e838f8655416295148c385a3983c5/view","enriched":true,"history":[{"index":3,"title":"Lab Microphone System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-30T13:36:00.993Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0d0e838f8655416295148c385a3983c5","solicitation_number":"PANRSA-26-P-0000-033738"}]},{"notice_id":"067ac36dbdd048c4a491db117b2b4193","title":"Lab Microphone System","solicitation_number":"PANRSA-26-P-0000-033738","notice_type":"a","base_type":"a","posted":"2026-10-13","posted_at":"2026-10-13T16:59:45.702Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-24","removed_at":null,"award_number":"W9124P-26-P-A093","awardee_name":"GFS SUPPLY & SERVICES COMPANY, INC.","amount":"35888.40","link_sam":"https://sam.gov/workspace/contract/opp/067ac36dbdd048c4a491db117b2b4193/view","enriched":true,"history":[{"index":1,"title":"Lab Microphone System","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-13T16:59:45.702Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"067ac36dbdd048c4a491db117b2b4193","solicitation_number":"PANRSA-26-P-0000-033738"}]}],"latest_notice_id":"067ac36dbdd048c4a491db117b2b4193","first_type":"s","notices":[{"dates":{"posted":"2026-03-09","posted_at":"2026-03-09T18:01:10.979Z","created_at":"2026-03-09T17:55:54.584Z","modified_at":"2026-04-18T03:55:46.116Z","response_deadline":{"raw":"2026-03-18T16:00:00-05:00","utc":"2026-03-18T21:00:00Z","date":"2026-03-18","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4a52cefe29534e7f99be1a704e54d095/view"},"naics":{"codes":["334310"],"primary":"334310"},"title":"Lab Standard Microphone System","agency":{"office":{"code":"W9124P","name":"W6QK ACC-RSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"35898-5200","city":"REDSTONE ARSENAL","state":"AL","country":"USA"},"organization_id":"500045860","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-02","archive_type":"auto15"},"history":[{"index":3,"title":"Lab Standard Microphone System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T15:30:50.362Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"1c6d967af342496f9cb7fd7f99032aff","solicitation_number":"PANRSA-26-P-0000-033738","parent_opportunity_id":"4a52cefe29534e7f99be1a704e54d095"},{"index":1,"title":"Lab Standard Microphone System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-09T18:01:10.979Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"4a52cefe29534e7f99be1a704e54d095","solicitation_number":"PANRSA-26-P-0000-033738"}],"contacts":[{"name":"Lisa Armes","role":"primary","email":"lisa.s.armes.civ@army.mil"},{"name":"LaToya Whitsett","role":"secondary","email":"latoya.t.whitsett.civ@army.mil"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"4a52cefe29534e7f99be1a704e54d095","lineage_id":"4a52cefe29534e7f99be1a704e54d095","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T10:46:04.854603693Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"568072e3e47e46a038415a79db4660dd186729e15c800c5a4d45f8f4cab4498f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T10:46:04.854603693Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The U.S. Army Contracting Command-Redstone, Operations, Services, &amp; Training Division, plans to obtain information to serve as market research to help identify potential sources that can provide a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):</p>\n\n<p><strong>4180&mdash;PTO</strong>&nbsp;&nbsp; 1/2&quot; Calibration Condenser Microphone, laboratory standard. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p><strong>ET-2014-W-002</strong>- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp; Qty: 1</p>\n\n<p><strong>4160&mdash;PTO</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1&quot; Laboratory Standard Pressure Microphone, 200V Polarization.&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p><strong>ET-2014-W-001</strong>-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty:1</p>\n\n<p><strong>AO-0087-D-012-</strong> Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85&deg;C (185&deg;F)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Qty:1</p>\n\n<p><strong>Shipping&nbsp; </strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;Qty: 2</p>\n\n<p>This RFI will utilize NAICS Code 334310.</p>","text":"The U.S. Army Contracting Command-Redstone, Operations, Services, & Training Division, plans to obtain information to serve as market research to help identify potential sources that can provide a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):\n\n4180—PTO 1/2\" Calibration Condenser Microphone, laboratory standard. Qty: 1\n\nET-2014-W-002- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180 Qty: 1\n\n4160—PTO 1\" Laboratory Standard Pressure Microphone, 200V Polarization. Qty: 1\n\nET-2014-W-001-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022 Qty:1\n\nAO-0087-D-012- Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85°C (185°F) Qty:1\n\nShipping Qty: 2\n\nThis RFI will utilize NAICS Code 334310.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"PANRSA-26-P-0000-033738","place_of_performance":{"zip":"35898","city":{"code":"63912","name":"Redstone Arsenal"},"state":{"code":"AL","name":"Alabama"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5965"},{"dates":{"posted":"2026-03-26","posted_at":"2026-03-26T15:30:50.362Z","created_at":"2026-03-26T15:28:38.944Z","modified_at":"2026-04-18T03:55:46.116Z","response_deadline":{"raw":"2026-04-02T16:00:00-05:00","utc":"2026-04-02T21:00:00Z","date":"2026-04-02","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1c6d967af342496f9cb7fd7f99032aff/view"},"naics":{"codes":["334310"],"primary":"334310"},"title":"Lab Standard Microphone System","agency":{"office":{"code":"W9124P","name":"W6QK ACC-RSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"35898-5200","city":"REDSTONE ARSENAL","state":"AL","country":"USA"},"organization_id":"500045860","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-17","archive_type":"auto15"},"history":[{"index":3,"title":"Lab Standard Microphone System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T15:30:50.362Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"1c6d967af342496f9cb7fd7f99032aff","solicitation_number":"PANRSA-26-P-0000-033738","parent_opportunity_id":"4a52cefe29534e7f99be1a704e54d095"},{"index":1,"title":"Lab Standard Microphone System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-09T18:01:10.979Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"4a52cefe29534e7f99be1a704e54d095","solicitation_number":"PANRSA-26-P-0000-033738"}],"contacts":[{"name":"Lisa Armes","role":"primary","email":"lisa.s.armes.civ@army.mil"},{"name":"LaToya Whitsett","role":"secondary","email":"latoya.t.whitsett.civ@army.mil"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"1c6d967af342496f9cb7fd7f99032aff","lineage_id":"4a52cefe29534e7f99be1a704e54d095","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T02:50:10.156164480Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"45cb4f60754a68ffa256265735cd6af0fb138669682c693c381056e6f52267e2","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T02:50:10.156164480Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The U.S. Army Contracting Command-Redstone, Operations, Services, &amp; Training Division, plans to obtain information to serve as market research to help identify potential sources that can provide a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):</p>\n\n<p><strong>4180&mdash;PTO</strong>&nbsp;&nbsp; 1/2&quot; Calibration Condenser Microphone, laboratory standard. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p><strong>ET-2014-W-002</strong>- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp; Qty: 1</p>\n\n<p><strong>4160&mdash;PTO</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1&quot; Laboratory Standard Pressure Microphone, 200V Polarization.&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p><strong>ET-2014-W-001</strong>-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty:1</p>\n\n<p><strong>AO-0087-D-012-</strong> Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85&deg;C (185&deg;F)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Qty:1</p>\n\n<p><strong>Shipping&nbsp; </strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;Qty: 2</p>\n\n<p>This RFI will utilize NAICS Code 334310.</p>","text":"The U.S. Army Contracting Command-Redstone, Operations, Services, & Training Division, plans to obtain information to serve as market research to help identify potential sources that can provide a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):\n\n4180—PTO 1/2\" Calibration Condenser Microphone, laboratory standard. Qty: 1\n\nET-2014-W-002- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180 Qty: 1\n\n4160—PTO 1\" Laboratory Standard Pressure Microphone, 200V Polarization. Qty: 1\n\nET-2014-W-001-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022 Qty:1\n\nAO-0087-D-012- Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85°C (185°F) Qty:1\n\nShipping Qty: 2\n\nThis RFI will utilize NAICS Code 334310.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"PANRSA-26-P-0000-033738","place_of_performance":{"zip":"35898","city":{"code":"63912","name":"Redstone Arsenal"},"state":{"code":"AL","name":"Alabama"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5965"},{"dates":{"posted":"2026-06-30","posted_at":"2026-06-30T13:36:00.993Z","created_at":"2026-06-30T13:29:35.524Z","modified_at":"2026-07-29T05:07:08.128Z","response_deadline":{"raw":"2026-07-14T11:00:00-04:00","utc":"2026-07-14T15:00:00Z","date":"2026-07-14","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0d0e838f8655416295148c385a3983c5/view"},"naics":{"codes":["334310"],"primary":"334310"},"title":"Lab Microphone System","agency":{"office":{"code":"W9124P","name":"W6QK ACC-RSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"35898-5200","city":"REDSTONE ARSENAL","state":"AL","country":"USA"},"organization_id":"500045860","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-29","archive_type":"auto15"},"history":[{"index":3,"title":"Lab Microphone System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-30T13:36:00.993Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0d0e838f8655416295148c385a3983c5","solicitation_number":"PANRSA-26-P-0000-033738"}],"contacts":[{"name":"LaToya Whitsett","role":"primary","email":"latoya.t.whitsett.civ@army.mil","phone":"5206748152"},{"name":"Lisa Armes","role":"secondary","email":"lisa.s.armes.civ@army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0d0e838f8655416295148c385a3983c5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"0d0e838f8655416295148c385a3983c5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T13:52:27.002405329Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"c279df63d315c758d5bd4c0a7f46f868963bdbc7a77a453ee7eac5109f4b2018","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T13:52:27.002405329Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>The U.S. Army TMDE Activity (USATA) has a requirement to implement a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):</p>\n\n<p><strong>1.0 Requirements:</strong></p>\n\n<p><strong>4180&mdash;PTO</strong>&nbsp;&nbsp; 1/2&quot; Calibration Condenser Microphone, laboratory standard. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p><strong>ET-2014-W-002</strong>- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp; Qty: 1</p>\n\n<p><strong>4160&mdash;PTO</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1&quot; Laboratory Standard Pressure Microphone, 200V Polarization.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Qty: 1</p>\n\n<p><strong>ET-2014-W-001</strong>-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Qty:1</p>\n\n<p><strong>AO-0087-D-012-</strong> Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85&deg;C (185&deg;F)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Qty:1</p>\n\n<p><strong>Shipping&nbsp; </strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;Qty: 2</p>\n\n<p><strong>2.0 Delivery Requirements</strong></p>\n\n<p>Shipping Address: U.S. Army TMDE Activity, Attn: Ricardo Gutierrez, Building 5435, Redstone Arsenal, AL 35898</p>\n\n<p></p>","text":"The U.S. Army TMDE Activity (USATA) has a requirement to implement a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):\n\n1.0 Requirements:\n\n4180—PTO 1/2\" Calibration Condenser Microphone, laboratory standard. Qty: 1\n\nET-2014-W-002- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180 Qty: 1\n\n4160—PTO 1\" Laboratory Standard Pressure Microphone, 200V Polarization. Qty: 1\n\nET-2014-W-001-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022 Qty:1\n\nAO-0087-D-012- Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85°C (185°F) Qty:1\n\nShipping Qty: 2\n\n2.0 Delivery Requirements\n\nShipping Address: U.S. Army TMDE Activity, Attn: Ricardo Gutierrez, Building 5435, Redstone Arsenal, AL 35898","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"PANRSA-26-P-0000-033738","place_of_performance":{"zip":"35898","city":{"code":"63912","name":"Redstone Arsenal"},"state":{"code":"AL","name":"Alabama"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5965"},{"award":{"date":"2026-09-24","amount":"35888.40","number":"W9124P-26-P-A093","awardee":{"raw":"GFS SUPPLY & SERVICES COMPANY, INC. East Hanover NJ 07936 USA","uei":"TRKLSHEHX274","cage":"7NNQ5","name":"GFS SUPPLY & SERVICES COMPANY, INC.","location":{"zip":"07936","city":{"code":"19210","name":"East Hanover"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-10-13","posted_at":"2026-10-13T16:59:45.702Z","award_date":"2026-09-24","created_at":"2026-10-13T16:39:01.276Z","modified_at":"2026-10-13T16:59:45.704Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/067ac36dbdd048c4a491db117b2b4193/view"},"naics":{},"title":"Lab Microphone System","agency":{"office":{"code":"W9124P","name":"W6QK ACC-RSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"35898-5200","city":"REDSTONE ARSENAL","state":"AL","country":"USA"},"organization_id":"500045860","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-24","archive_type":"auto_custom"},"history":[{"index":1,"title":"Lab Microphone System","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-13T16:59:45.702Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"067ac36dbdd048c4a491db117b2b4193","solicitation_number":"PANRSA-26-P-0000-033738"}],"contacts":[{"name":"LaToya Whitsett","role":"primary","email":"latoya.t.whitsett.civ@army.mil","phone":"5206748152"},{"name":"Lisa Armes","role":"secondary","email":"lisa.s.armes.civ@army.mil"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"067ac36dbdd048c4a491db117b2b4193","lineage_id":"067ac36dbdd048c4a491db117b2b4193","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T06:59:45.417854492Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"41eb71cbb11d7265b7d0141a8104a834-25\"","fetched_at":"2026-10-14T03:54:05.500072632Z","row_sha256":"ea24fc91c26f7512456b88bffd1b5c7a6902227fc6b15ea76f349a81de6b3054","last_modified":"2026-10-14T03:30:44Z"},"updated_at":"2026-10-14T06:59:45.417854492Z","first_seen_at":"2026-10-14T03:54:05.500072632Z"},"description":{"html":"<p>The U.S. Army TMDE Activity (USATA) has a requirement to implement a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Requirements:</strong></li>\n</ol>\n\n<p>&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p><strong>4180&mdash;PTO</strong>&nbsp;&nbsp; 1/2&quot; Calibration Condenser Microphone, laboratory standard.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p></p>\n\n<p><strong>ET-2014-W-002</strong>- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; Qty: 1</p>\n\n<p></p>\n\n<p><strong>4160&mdash;PTO</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1&quot; Laboratory Standard Pressure Microphone, 200V Polarization.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p></p>\n\n<p><strong>ET-2014-W-001</strong>-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty:1</p>\n\n<p></p>\n\n<p><strong>AO-0087-D-012-</strong> Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85&deg;C (185&deg;F)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;Qty:1</p>\n\n<p></p>\n\n<p><strong>Shipping&nbsp; </strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;Qty:2 &nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Delivery Requirements</strong></li>\n</ol>\n\n<p>Shipping Address: U.S. Army TMDE Activity, Attn: Ricardo Gutierrez, Building 5435, Redstone Arsenal, AL 35898</p>\n\n<p></p>","text":"The U.S. Army TMDE Activity (USATA) has a requirement to implement a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):\n\n• Requirements:\n\n4180—PTO 1/2\" Calibration Condenser Microphone, laboratory standard. Qty: 1\n\nET-2014-W-002- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180 Qty: 1\n\n4160—PTO 1\" Laboratory Standard Pressure Microphone, 200V Polarization. Qty: 1\n\nET-2014-W-001-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022 Qty:1\n\nAO-0087-D-012- Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85°C (185°F) Qty:1\n\nShipping Qty:2\n\n• Delivery Requirements\n\nShipping Address: U.S. Army TMDE Activity, Attn: Ricardo Gutierrez, Building 5435, Redstone Arsenal, AL 35898","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"PANRSA-26-P-0000-033738","place_of_performance":{"zip":"35898","city":{"code":"63912","name":"Redstone Arsenal"},"state":{"code":"AL","name":"Alabama"},"country":{"code":"USA","name":"UNITED STATES"}}}],"due_at":"2026-07-14T15:00:00Z","due_date":"2026-07-14","closes_at":"2026-07-14T15:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9124P","office_name":"W6QK ACC-RSA","state":"AL","county":"01089","county_name":"Madison County","city":"0163912","city_name":"Redstone Arsenal","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"TRKLSHEHX274","amount":"35888.40","linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-25T06:21:39.027519Z","principal_notice_id":"067ac36dbdd048c4a491db117b2b4193","description":{"text":"The U.S. Army TMDE Activity (USATA) has a requirement to implement a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):\n\n• Requirements:\n\n4180—PTO 1/2\" Calibration Condenser Microphone, laboratory standard. Qty: 1\n\nET-2014-W-002- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180 Qty: 1\n\n4160—PTO 1\" Laboratory Standard Pressure Microphone, 200V Polarization. Qty: 1\n\nET-2014-W-001-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022 Qty:1\n\nAO-0087-D-012- Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85°C (185°F) Qty:1\n\nShipping Qty:2\n\n• Delivery Requirements\n\nShipping Address: U.S. Army TMDE Activity, Attn: Ricardo Gutierrez, Building 5435, Redstone Arsenal, AL 35898","html":"<p>The U.S. Army TMDE Activity (USATA) has a requirement to implement a brand name purchase of one (1) Lab Standard Microphone System model or equivalent that will be a suitable replacement for the 4180/4160 Microphones are the main standard for the Acoustics Lab. Three standards have been lost due to damage. Reciprocity calibration requires three microphones of the same model to function appropriately. APSL needs to replace these standards to prevent a potential shutdown of the acoustics laboratory. All accredited parameters within the acoustics lab are tied to these laboratory grade Microphones. The Lab Standard Microphone System shall include the following specifications or equivalent (if not brand name):</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Requirements:</strong></li>\n</ol>\n\n<p>&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p><strong>4180&mdash;PTO</strong>&nbsp;&nbsp; 1/2&quot; Calibration Condenser Microphone, laboratory standard.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p></p>\n\n<p><strong>ET-2014-W-002</strong>- Primary DPLA Microphone Calibration 1/3 octave frequencies 10Hz to 25 kHz for type 4180&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; Qty: 1</p>\n\n<p></p>\n\n<p><strong>4160&mdash;PTO</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1&quot; Laboratory Standard Pressure Microphone, 200V Polarization.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;Qty: 1</p>\n\n<p></p>\n\n<p><strong>ET-2014-W-001</strong>-Primary DPLA Microphone Calibration 1/3 octave frequencies 2Hz to 10kHz for type 4160. Results calculated according to IEC 61094-2:2009/AMD1:2022&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Qty:1</p>\n\n<p></p>\n\n<p><strong>AO-0087-D-012-</strong> Cable, coax single screen, BNC (M) to BNC (M), 1,2m (4.0ft), max.+85&deg;C (185&deg;F)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;Qty:1</p>\n\n<p></p>\n\n<p><strong>Shipping&nbsp; </strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;Qty:2 &nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Delivery Requirements</strong></li>\n</ol>\n\n<p>Shipping Address: U.S. Army TMDE Activity, Attn: Ricardo Gutierrez, Building 5435, Redstone Arsenal, AL 35898</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"LaToya Whitsett","role":"primary","email":"latoya.t.whitsett.civ@army.mil","phone":"5206748152"},{"name":"Lisa Armes","role":"secondary","email":"lisa.s.armes.civ@army.mil"}],"place_of_performance":{"zip":"35898","city":{"code":"63912","name":"Redstone Arsenal"},"state":{"code":"AL","name":"Alabama"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"35898-5200","city":"REDSTONE ARSENAL","state":"AL","country":"USA"},"naics_codes":[],"award":{"date":"2026-09-24","amount":"35888.40","number":"W9124P-26-P-A093","awardee":{"raw":"GFS SUPPLY & SERVICES COMPANY, INC. East Hanover NJ 07936 USA","uei":"TRKLSHEHX274","cage":"7NNQ5","name":"GFS SUPPLY & SERVICES COMPANY, INC.","location":{"zip":"07936","city":{"code":"19210","name":"East Hanover"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"70545410abe64232ad5f864bdc19758d","name":"Lab Microphone System RFQ.docx","kind":"file","mime_type":".docx","size_bytes":21790,"posted_at":"2026-06-30T13:36:00.993Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/70545410abe64232ad5f864bdc19758d/download","mirrored":false},{"resource_id":"0c14f341bbb74fdba33b6e23860b13b6","name":"Purchase Description (W80RA6-05-26C) PANRSA-26-P-0000 033738.docx","kind":"file","mime_type":".docx","size_bytes":17653,"posted_at":"2026-03-09T18:01:10.979Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0c14f341bbb74fdba33b6e23860b13b6/download","mirrored":false}],"awards":[],"related":[{"key":"PANRSA27P000001","latest_notice_id":"d42cc82803064a10a68625d59c824d29","title":"Enterprise Information Technology Support Services (ITSS)","solicitation_number":"PANRSA27P000001","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-18T16:00:00Z","due_date":"2026-12-18","closes_at":"2026-12-18T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9124P","office_name":"W6QK ACC-RSA","naics":"541512","psc":"DG01","set_aside":null,"state":"AL","county":"01089","county_name":"Madison County","city":"0163912","city_name":"Redstone Arsenal","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"N0010426QND96","latest_notice_id":"f5e2d10e7ded4876a0c86315917b9c33","title":"CIRCUIT CARD ASSEMB","solicitation_number":"N0010426QND96","notice_type":"o","first_type":"o","first_posted":"2026-08-03","last_posted":"2026-10-21","notices":6,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"334310","psc":"5965","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 5965)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"},{"key":"SPE7M227U0054","latest_notice_id":"cc0c9e61221946298b981b4be895a507","title":"59--HOLDER,HANDSET","solicitation_number":"SPE7M227U0054","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M2","office_name":"DLA WEAPONS SUPPORT","naics":"334310","psc":"59","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 58. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"SPE7M527U0079","latest_notice_id":"2fe95c7debdc4e838a80985acfc299f9","title":"59--HEADSET,ELECTRICAL","solicitation_number":"SPE7M527U0079","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M5","office_name":"DLA WEAPONS SUPPORT","naics":"334310","psc":"59","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"NTITY WILL BE 6. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":52,"indexable":false}