Sources sought

Gas Chromatograph with Dual Electron Capture Detector (GS-Dual ECD)

PANHCA-25-P-0000-025637

Department of the Army, W40M Mrco Europe. Surgical and Medical Instrument Manufacturing.

Response deadline

July 29, 2025 at 6:00 AM EDT

Closed 485 days ago. Posted July 23, 2025. Scheduled to archive August 13, 2025.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2025

15 like it are open now in surgical and medical instrument manufacturing

All 15 open in surgical and medical instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339112 (surgical and medical instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of July 23, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

THIS IS A SOURCES SOUGHT/REQUEST FOR INFORMATION ONLY. This is not a Solicitation Announcement, nor is it a Request for Proposal. This request does not obligate the Government in any contract award. The USAHCA – Medical Readiness Contracting Office Europe-USAHCA-MRCO-EUR is issuing the sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support the requirement for Gas Chromatograph with Dual Electron Capture Detector. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 339112 (Surgical and Medical Instrument Manufacturing) with business size standard 1,000 Employees.  PSC code is 6630 – Chemical Analysis Instruments.

The anticipated delivery 45 days after contract award.

The delivery address:

Regional Landstuhl Medical Center

Landstuhl, Germany

S

ALIENT CHARACTERISTICS

Brand Name or Equal

• Gas Chromatograph with dual Electron Capture Detector (GC-μECD) and dual liquid autosamplers with the ability to screen drinking water and food samples for a wide array of prominent and emergent organic pollutants simultaneously.

o Operation Workstation must be included with the equipment.

o Data acquisition and processing software to control instrument and process data must be included.

o System must run all software on Windows 11.

o System must have two split/split less injection ports.

o System must have two Electron Capture Detectors with EPCs.

o The instrument must have capability for simultaneous and independent detection of each ECD.

o Equipment must be able to operate on 230V/50 Hz.

• Two liquid autosamplers must be included with the equipment, including a tray for samples. o Auto-sampler tray with capacity of at least 150 samples and ability to cool samples ≤6C.

o Instrument must include two autosamplers with the capability for simultaneous dual column injection onto two inlets.

• The GC system must have an integrated compartment with capability for at least 2 columns with quick-connect fittings for facile switching between methods.

• The instrument must have capability for simultaneous and independent detection of each ECD.

• The system should come equipped with all necessary consumables to run methods EPA 505, 504.1, 515.4 and 553.2 (Split less liners, Dissimilar Pesticide columns, ferrules, seals, etc.)

• The system must come with a minimum of a one-year warranty.

• The system must come with operation and troubleshooting manuals.

• Instrument must be installed by a qualified service representative and properly verified for use.

If you are interested in participating in this requirement and/or your organization has the potential capacity to perform these services, please submit the following to the Point of Contacts (POC) information listed below: 

1.  Name and Address of your Firm
2.  Point of Contact (name/phone/email)
3.  Company website
4.  Unique Entity identifier (UEI) number
5.  Commercial and Government Entity (CAGE) code 

6.  Capability statement -

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 23, 2025

    Sources sought

    Due July 29, 2025 at 6:00 AM EDT. SAM.gov, notice 73114fdc98b142efbb8939f5409d7506

    1 revision on SAM
    • July 23, 2025: publish, sources sought

Points of contact