Combined synopsis and solicitation
Procurement of Benchtop Environmental Temp/Humidity Chamber
OC-2026-136029
Food and Drug Administration, FDA Office of Acq Grant SVCS. Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables.
Response deadline
September 25, 2026 at 12:00 PM EDT
Closed 61 days ago. Posted September 23, 2026, first published September 21, 2026. Scheduled to archive October 10, 2026.
Get the next one like this from Food and Drug Administration by email, the day it is posted.Find my opportunities
This one closed in 2026
30 like it are open now in instruments and related products manufacturing for measuring, displaying, and controlling industrial process variables
- RFI Process control system plumbing and programming
Department of the Army, W6QK ACC-APG Natick
Sources soughtNAICS 334513Natick, MARFIProcessControlSystemPlumbingAndProgrammingDue tomorrowNov 26 - Peel 3 3D Scanners and Software BPA
Department of the Navy, NSWC Carderock
Combined synopsis and solicitationSmall businessNAICS 334513Ship to the buyerN0016727Q1010Due todayNov 25 - SPE4A527R0007; 6685014552559; Indicator, Pressure
Defense Logistics Agency, DLA Aviation
PresolicitationNAICS 334513Ship to VASPE4A527R0007Due todayNov 25
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334513 (instruments and related products manufacturing for measuring, displaying, and controlling industrial process variables), means no more than 750 employees, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 4 days from the day the solicitation was posted, September 21, 2026, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. The NAICS for this requirement is: 334516. The government is not obligated to make an award. The Government is not obligated to pay costs incurred by the Contractor during quote preparation and quote submission.
Background: The FDA laboratory at the Winchester Engineering Analytical Center (WEAC) uses an environmental chamber to condition regulatory samples (such as tampons, gowns, patches, etc.) at specific temperature and humidity levels before physical testing. The chamber also supports CDRH-directed research and test method development for other medical devices received by the laboratory for analysis.
Minimum Performance Requirements/Salient Characteristics:
This is a Brand Name or Equal requirement. Products other than the aforementioned are acceptable but shall meet all the salient characteristics contained in the Minimum Technical Requirements below:
All of the following system requirements are minimum requirements. Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated by the WEAC prior to purchase:
General
The contractor shall provide an environmental chamber that uniformly conditions samples across a variety of temperature and humidity settings. The chamber must meet the following specifications:
- Temperature range: at least -20°C to 180°C
- Humidity range: 10% to 95% relative humidity (RH)
- Capacity: 4 cu. Ft.
- Power: Standard power cord and plug (no hardwiring)
- Water supply: Easily accessible water supply connection
- Humidity sensor: Solid-state humidity sensor
- Leak Detection: Must have a water leak containment and detection system
- Viewing window: For visual monitoring of samples
- Interior shelf: At least one internal shelf
- Mobility: Mobile cart with space-saving footprint (lab has no bench space and limited floor space for the chamber)
- Cable port: At least one 2-inch diameter cable port with a flexible plug
- Calibration: Factory calibration with an ISO 17025 certificate, or instrument calibration at start-up with ISO 17025 certificate
- Warranty: At least one year
Additional Specifications are included in the updated attachments
On-site Installation, Training and Commissioning
- On-site installation and commissioning of the Environmental Chamber
Trade and Service Specification
- All components shall be newly manufactured, not used or refurbished, and/or previously used for demonstration.
- System installation shall occur after being received at the laboratory.
- The entire system shall be warranted for parts and labor for a minimum of 12 months from date of formal government acceptance after on-site installation.
- The warranty must include unlimited telephone/e-mail support for questions regarding operation.
Additional Section 508 Requirements:
-
-
- Must meet WCAG 2.0 A and AA
- E101.2 Equivalent Facilitation (Appendix A, Application and Scoping Requirements)
- E203 Access to Functionality (Appendix A, Application and Scoping Requirements)
- E204 Functional Performance Criteria (Appendix A, Application and Scoping Requirements)
- E205 Electronic Content (Appendix A, Application and Scoping Requirements)
- 302 Functional Performance Criteria (Appendix C, Functional Performance Criteria and Technical Requirements)
- Electronic content must be accessible to HHS acceptance criteria. Checklist for various formats are available at https://www.hhs.gov/web/section-508/making-files-
-
accessible/index.html, or from the Section 508 Coordinator listed at https://www.hhs.gov/web/section-508/additional- resources/section-508-
contacts/index.html. Materials that are final items for delivery should be accompanied by the appropriate checklist, except upon approval of the Contracting Officer or Representative.
-
-
- E208 Support Documentation and Services (Appendix A, Application and Scoping Requirements)
- Chapter 6 Support Documentation and Services (Appendix C, Functional Performance Criteria
- E206 Hardware (Appendix A, Application and Scoping Requirements)
- Chapter 4 Hardware (Appendix C, Functional Performance Criteria and Technical Requirements) and Technical Requirements)
- E207 Software (Appendix A, Application and Scoping Requirements)
- Chapter 5 Software (Appendix C, Functional Performance Criteria and Technical Requirements)
-
Place of Performance:
The prospective vendor should provide insured shipping of equipment to:
U.S. Food and Drug Administration,
Winchester Engineering and Analytical Center
(WEAC)
Office of Specialty Laboratories and Enforcement Support
109 Holton Street
Winchester, MA 01890
Period of Performance:
Performance begins on the date of formal government acceptance and continues through the end of the manufacturer's warranty period.
Quotes are due by email on or before September 25 2026, by 12:00 P.M. (Eastern Standard Time) and should be sent to brandon.rafus@fda.hhs.gov.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Combined Synopsis Solicitation- FDA-RFQ- OC-2026-136029.pdf417 KB, September 21, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
September 21, 2026
Combined synopsis and solicitation
Due September 25, 2026 at 12:00 PM EDT. SAM.gov, notice 8b366130444f467bbf9556ba8ea6632a
1 revision on SAM
- September 21, 2026: publish, combined synopsis and solicitation
September 23, 2026
Combined synopsis and solicitation
Due September 25, 2026 at 12:00 PM EDT. SAM.gov, notice ab4d6b0cc41e42909c812cd9c517d6a6
2 revisions on SAM
- September 23, 2026: publish, combined synopsis and solicitation
- September 21, 2026: publish, combined synopsis and solicitation
Points of contact
- Brandon Rafusbrandon.rafus@fda.hhs.gov