Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 9,309 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Presolicitation

Maxcyte ExPERT STx Flow Electroporation Platform Generation 3 System

NOI-NIAID-24-2224326

National Institutes of Health, National Institutes of Health Niaid. Analytical Laboratory Instrument Manufacturing.

Response deadline

June 26, 2024 at 5:00 PM EDT

Closed 884 days ago. Posted June 21, 2024. Scheduled to archive July 11, 2024.

Get the next one like this from National Institutes of Health by email, the day it is posted.Find my opportunities

This one closed in 2024

53 like it are open now in analytical laboratory instrument manufacturing

All 53 open in analytical laboratory instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the presolicitation of June 21, 2024. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

PRE-SOLICITATION NOTICE **NOTICE OF INTENT NOI-NIAID-24-2224326 NAICS – 334516 This is a Notice of Intent, not a request for proposal. The National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH) intends to negotiate on an other than full and open competition basis with MaxCyte Inc to procure a Maxcyte ExPERT STx Flow Electroporation Platform Generation 3 system.

Maxcyte will provide a one-year warranty, technical support, installation, training, and ongoing technical assistance. The Cell Line Development Team at the Vaccine Production Program (VPP) of the Vaccine Research Center (VRC) is responsible for generating clonally-derived cell lines expressing monoclonal antibodies and vaccine candidates that will be used for clinical manufacturing.

Additionally, the team generates material using transient expression and stable pool generation processes that provide reagent-grade material to support pre-clinical and clinical studies. These processes all begin with transfection of a mammalian cell line with plasmid DNA encoding the protein of interest. Efficient transfection requires significant optimization of the transfection method and conditions to ensure high transfection efficiency and cell viability.

The MaxCyte STx scalable transfection system is a validated platform for cell transfection using flow electroporation. It enables rapid and efficient transfection of multiple cell types with a variety of molecules at various scales without specific reagents. The MaxCyte STX operates as a sterile, closed system that provides unparalleled consistency, flexibility, scalability, and loading efficiency. It offers the ability to transfect cells at scales ranging from 75 thousand to 20 billion cells.

Currently the VPP uses an older model of this instrument to initiate all CLD processes including transient protein production, stable pool generation, and single cell cloning. The VPP has optimized protocols to ensure high transfection efficiency and cell viability. The scalability of the instrument is unique and allows the program to consistently transfect cells at various scales depending on the material need.

After 10 years of reliable use, the VPP is beginning to experience intermittent issues with the instrument. Acquiring the newer model will allow the VPP to have a seamless transition and continue to use all existing SOPs without impact to their processes as the core technology of the instrument remains the same. Changing to a different instrument or transfection method would require significant redevelopment and would be likely to significantly impact the project timelines, efficiency, and production levels.

The statutory authority for this sole source requirement is 41 U.S.C. 1901(e)(2) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL.

All responsible sources that could provide comparable services may submit a capability statement that will be considered by email (subject line to reference NOI-NIAID-24-2224326) to Dana Monroe at dana.monroe@nih.gov by 5:00 pm eastern time Wednesday, June 26, 2024. All responses received by the closing date of this synopsis will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. June 21, 2024

    Presolicitation

    Due June 26, 2024 at 5:00 PM EDT. SAM.gov, notice 2535fe6cdb2b4c0eaffb9e871ac17be0

Points of contact