Presolicitation
TSI aerodynamic particle sizer (APS) spectrometer system, catalog # 3321, with software, flow meter and filters
NOI-NIAID-24-2206603
National Institutes of Health, National Institutes of Health Niaid. Analytical Laboratory Instrument Manufacturing.
Response deadline
January 10, 2024 at 5:00 PM EST
Closed 1052 days ago. Posted January 4, 2024. Scheduled to archive January 25, 2024.
Get the next one like this from National Institutes of Health by email, the day it is posted.Find my opportunities
This one closed in 2024
53 like it are open now in analytical laboratory instrument manufacturing
- Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due todayNov 27 - Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology, Department of Commerce NIST
Sources soughtNAICS 334516Ship to Gaithersburg, MDNIST-MML-FY27-SS01Due tomorrowNov 28 - Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
Department of the Army, W6QK ACC-APG Adelphi
SolicitationNAICS 334516Ship to MDW911QX27QA015Due in 4 daysDec 1
All 53 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the presolicitation of January 4, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
PRE-SOLICITATION NOTICE ** NOTICE OF INTENT NOI-NIAID-24-2206603 NAICS – 334516, Analytical Laboratory Instrument Mfg This is a Notice of Intent, not a request for proposal.
The National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH) Integrated Research Facility (IRF) intends to negotiate on an other than full and open competition basis with TSI Incorporated of Shoreview, MN to procure an additional TSI aerodynamic particle sizer (APS) spectrometer system, catalog # 3321, with software, flow meter and filters, for the continuation of a collaborative project with the National Biodefense Analysis and Countermeasures Center (NBACC) to explore small and large particle aerosol deposition using modalities within the respiratory tract of rodents.
The Aerobiology section of the IRF develops aerosol animal models of disease caused by high consequence pathogens within high containment animal biosafety level-4 (ABSL-4) and BSL-4. Therapeutic and prophylactic agents (e.g. vaccines) are evaluated in these animal models. Additionally, this section evaluates and compares virus deposition, infectivity, and virulence among animals inoculated with aerosols versus other routes of administration (e.g. intramuscular).
A major focus of this aerosol research is exploring various particle sizes (small, intermediate and large) and monitoring deposition sites within the lower, mid and upper respiratory tract; and comparing subsequent disease course outcomes for potential medical countermeasure development. To determine the particle size for a specific aerosol run, an APS is required to generate a reading of the actual particles generated and sampled.
This provides the researcher feedback for the aerosol system and shows if desired target particle size is equivalent to the actual particle size. This TSI brand APS provides a high-resolution, real-time aerodynamic measurement of particles ranging from 0.5 to 20.0 µm, thus encompassing all size ranges affecting the respiratory tract and mucosa.
This APS uses a patented, double-crest optical laser system for sizing accuracy which results in greater small particle sizing efficiency, improved accuracy of mass-weighted distributions and virtual elimination of false background counts. All previous data recorded from the Integrated Research Facility’s aerosol animal models since inception have used these TSI brand APS systems.
Trying to correlate the data between any equipment other than this APS would require several bridging studies to ensure accuracy and proper conversion if this is even applicable. This will be very taxing/costly on facility resources. This APS is what the collaborator used during preliminary testing prior to equipment transfer. All data acquired is based on collection and analysis using APS technology. The statutory authority for this sole source requirement is 41 U.S.C.
1901 (a) (1) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL.
All responsible sources that could provide comparable services may submit a capability statement that will be considered by email (subject line to reference NOI-NIAID-24-2206603) to Dana Monroe at dana.monroe@nih.gov, by 5:00pm eastern daylight savings time Wednesday, January 10, 2024. All responses received by the closing date of this synopsis will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.