{"canonical":"https://sealedbidder.com/opportunities/nistamdpmlssn2606","key":"NISTAMDPMLSSN2606","url":"https://sealedbidder.com/opportunities/nistamdpmlssn2606","title":"Advanced Multichannel Multispectral Photodetection System","solicitation_number":"NIST-AMD-PML-SSN-26-06","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-12T13:00:00Z","first_posted":"2026-06-05","last_posted":"2026-06-05","department":"COMMERCE, DEPARTMENT OF","subagency":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6695","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2431175","place_city_name":"Gaithersburg","winner":null,"award_amount":null,"publications":[{"notice_id":"0d5f4422b4b046f6b3724c6151e4ec95","title":"Advanced Multichannel Multispectral Photodetection System","solicitation_number":"NIST-AMD-PML-SSN-26-06","notice_type":"r","base_type":"r","posted":"2026-06-05","posted_at":"2026-06-05T13:11:59.965Z","due_at":"2026-06-12T13:00:00Z","due_date":"2026-06-12","cancelled":false,"archived":true,"archive_date":"2026-06-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0d5f4422b4b046f6b3724c6151e4ec95/view","enriched":true,"history":[{"index":4,"title":"Advanced Multichannel Multispectral Photodetection System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-10T17:30:06.671Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5e38c46333d448bb93393f247220655d","solicitation_number":"1333ND26QNB680346","related_opportunity_id":"0d5f4422b4b046f6b3724c6151e4ec95"},{"index":3,"title":"Advanced Multichannel Multispectral Photodetection System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T13:11:59.965Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0d5f4422b4b046f6b3724c6151e4ec95","solicitation_number":"NIST-AMD-PML-SSN-26-06"}]}],"latest_notice_id":"0d5f4422b4b046f6b3724c6151e4ec95","first_type":"r","notices":[{"dates":{"posted":"2026-06-05","posted_at":"2026-06-05T13:11:59.965Z","created_at":"2026-06-05T13:08:11.816Z","modified_at":"2026-06-28T04:13:13.853Z","response_deadline":{"raw":"2026-06-12T09:00:00-04:00","utc":"2026-06-12T13:00:00Z","date":"2026-06-12","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0d5f4422b4b046f6b3724c6151e4ec95/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Advanced Multichannel Multispectral Photodetection System","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_id":"100182905","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-27","archive_type":"auto15"},"history":[{"index":4,"title":"Advanced Multichannel Multispectral Photodetection System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-10T17:30:06.671Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5e38c46333d448bb93393f247220655d","solicitation_number":"1333ND26QNB680346","related_opportunity_id":"0d5f4422b4b046f6b3724c6151e4ec95"},{"index":3,"title":"Advanced Multichannel Multispectral Photodetection System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T13:11:59.965Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0d5f4422b4b046f6b3724c6151e4ec95","solicitation_number":"NIST-AMD-PML-SSN-26-06"}],"contacts":[{"name":"Robert Singman","role":"primary","email":"robert.singman@nist.gov","phone":"3019756388"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"0d5f4422b4b046f6b3724c6151e4ec95","lineage_id":"0d5f4422b4b046f6b3724c6151e4ec95","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T15:31:03.903742582Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"79e26ef87044a414ed57c7a462cadd89ab0f570194639802bdaade7ed3ed7f2f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T15:31:03.903742582Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The National Institute of Standards and Technology (NIST), Biophysical and Biomedical Measurement Group (BBMG) within the Microsystems and Nanotechnology Division of the Physical Measurement Laboratory (PML) requires an advanced spectral photodetection system for incorporation into NIST&rsquo;s unique and world-class Serial Flow Cytometer for high temporal and spectral resolution optical measurements of biological micro and nanoparticles. This will enable accomplishment of our mission of developing microscale measurement science and technology applied to characterization of biological systems.<br />\nFlow cytometry is a technology that rapidly analyzes properties of thousands of single cells or particles per second as they flow in a fluid stream. A laser incident on the fluid stream interrogates the cells, which can be labeled with fluorescent markers to enable the quantification of specific cell markers and classification of different cell types within populations. NIST develops a Serial Flow Cytometer (SFC) that uses multiple light sources to repeat optical measurements of single cells to provide uncertainty quantification (UQ). UQ is a valuable outcome that enables optimization of flow cytometers and modeling to improve confidence in flow cytometry measurements and instrument comparability.</p>\n\n<p><br />\nNIST requires a complete, multichannel and multispectral photodetector system as listed below in the Scope and specified below in Minimum Requirements. The system will integrate directly into NIST&rsquo;s Serial Flow Cytometer to perform sensitive, dynamic, and hyperspectral fluorescence measurements of rapidly flowing micro and nanoparticles including cells, gene therapy nanoparticles, and fluorescence calibration particles. Incorporation of the system within NIST instruments requires compatible connections to optical lines and routing of voltage signals to NIST recording devices.</p>\n\n<p>The advanced photodetector system is critical to achieve NIST project missions as it will enable the R&amp;D team to build generalizable, multimodal cytometric tools with world-class deep spectral probing to advance Critical and Emerging Technologies (CETs) in Biotechnology.</p>","text":"The National Institute of Standards and Technology (NIST), Biophysical and Biomedical Measurement Group (BBMG) within the Microsystems and Nanotechnology Division of the Physical Measurement Laboratory (PML) requires an advanced spectral photodetection system for incorporation into NIST’s unique and world-class Serial Flow Cytometer for high temporal and spectral resolution optical measurements of biological micro and nanoparticles. This will enable accomplishment of our mission of developing microscale measurement science and technology applied to characterization of biological systems.\n\nFlow cytometry is a technology that rapidly analyzes properties of thousands of single cells or particles per second as they flow in a fluid stream. A laser incident on the fluid stream interrogates the cells, which can be labeled with fluorescent markers to enable the quantification of specific cell markers and classification of different cell types within populations. NIST develops a Serial Flow Cytometer (SFC) that uses multiple light sources to repeat optical measurements of single cells to provide uncertainty quantification (UQ). UQ is a valuable outcome that enables optimization of flow cytometers and modeling to improve confidence in flow cytometry measurements and instrument comparability.\n\nNIST requires a complete, multichannel and multispectral photodetector system as listed below in the Scope and specified below in Minimum Requirements. The system will integrate directly into NIST’s Serial Flow Cytometer to perform sensitive, dynamic, and hyperspectral fluorescence measurements of rapidly flowing micro and nanoparticles including cells, gene therapy nanoparticles, and fluorescence calibration particles. Incorporation of the system within NIST instruments requires compatible connections to optical lines and routing of voltage signals to NIST recording devices.\n\nThe advanced photodetector system is critical to achieve NIST project missions as it will enable the R&D team to build generalizable, multimodal cytometric tools with world-class deep spectral probing to advance Critical and Emerging Technologies (CETs) in Biotechnology.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"NIST-AMD-PML-SSN-26-06","place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6695"}],"due_at":"2026-06-12T13:00:00Z","due_date":"2026-06-12","closes_at":"2026-06-12T13:00:00Z","awardable":true,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T15:33:52.429093Z","principal_notice_id":"0d5f4422b4b046f6b3724c6151e4ec95","description":{"text":"The National Institute of Standards and Technology (NIST), Biophysical and Biomedical Measurement Group (BBMG) within the Microsystems and Nanotechnology Division of the Physical Measurement Laboratory (PML) requires an advanced spectral photodetection system for incorporation into NIST’s unique and world-class Serial Flow Cytometer for high temporal and spectral resolution optical measurements of biological micro and nanoparticles. This will enable accomplishment of our mission of developing microscale measurement science and technology applied to characterization of biological systems.\n\nFlow cytometry is a technology that rapidly analyzes properties of thousands of single cells or particles per second as they flow in a fluid stream. A laser incident on the fluid stream interrogates the cells, which can be labeled with fluorescent markers to enable the quantification of specific cell markers and classification of different cell types within populations. NIST develops a Serial Flow Cytometer (SFC) that uses multiple light sources to repeat optical measurements of single cells to provide uncertainty quantification (UQ). UQ is a valuable outcome that enables optimization of flow cytometers and modeling to improve confidence in flow cytometry measurements and instrument comparability.\n\nNIST requires a complete, multichannel and multispectral photodetector system as listed below in the Scope and specified below in Minimum Requirements. The system will integrate directly into NIST’s Serial Flow Cytometer to perform sensitive, dynamic, and hyperspectral fluorescence measurements of rapidly flowing micro and nanoparticles including cells, gene therapy nanoparticles, and fluorescence calibration particles. Incorporation of the system within NIST instruments requires compatible connections to optical lines and routing of voltage signals to NIST recording devices.\n\nThe advanced photodetector system is critical to achieve NIST project missions as it will enable the R&D team to build generalizable, multimodal cytometric tools with world-class deep spectral probing to advance Critical and Emerging Technologies (CETs) in Biotechnology.","html":"<p>The National Institute of Standards and Technology (NIST), Biophysical and Biomedical Measurement Group (BBMG) within the Microsystems and Nanotechnology Division of the Physical Measurement Laboratory (PML) requires an advanced spectral photodetection system for incorporation into NIST&rsquo;s unique and world-class Serial Flow Cytometer for high temporal and spectral resolution optical measurements of biological micro and nanoparticles. This will enable accomplishment of our mission of developing microscale measurement science and technology applied to characterization of biological systems.<br />\nFlow cytometry is a technology that rapidly analyzes properties of thousands of single cells or particles per second as they flow in a fluid stream. A laser incident on the fluid stream interrogates the cells, which can be labeled with fluorescent markers to enable the quantification of specific cell markers and classification of different cell types within populations. NIST develops a Serial Flow Cytometer (SFC) that uses multiple light sources to repeat optical measurements of single cells to provide uncertainty quantification (UQ). UQ is a valuable outcome that enables optimization of flow cytometers and modeling to improve confidence in flow cytometry measurements and instrument comparability.</p>\n\n<p><br />\nNIST requires a complete, multichannel and multispectral photodetector system as listed below in the Scope and specified below in Minimum Requirements. The system will integrate directly into NIST&rsquo;s Serial Flow Cytometer to perform sensitive, dynamic, and hyperspectral fluorescence measurements of rapidly flowing micro and nanoparticles including cells, gene therapy nanoparticles, and fluorescence calibration particles. Incorporation of the system within NIST instruments requires compatible connections to optical lines and routing of voltage signals to NIST recording devices.</p>\n\n<p>The advanced photodetector system is critical to achieve NIST project missions as it will enable the R&amp;D team to build generalizable, multimodal cytometric tools with world-class deep spectral probing to advance Critical and Emerging Technologies (CETs) in Biotechnology.</p>","origin":"detail"},"contacts":[{"name":"Robert Singman","role":"primary","email":"robert.singman@nist.gov","phone":"3019756388"}],"place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"03f665cb9fe84114ae15be227a826520","name":"09-Sources Sought Notice-Photodetector System.pdf","kind":"file","mime_type":".pdf","size_bytes":212605,"posted_at":"2026-06-05T13:11:59.965Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/03f665cb9fe84114ae15be227a826520/download","mirrored":false}],"awards":[],"related":[{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"NISTSS26CHIPS13","latest_notice_id":"0124b2bd52b742b8a14350289fc0626d","title":"Sources Sought Notice for Mid-IR Optical Frequency Comb","solicitation_number":"NIST-SS26-CHIPS-13","notice_type":"r","first_type":"r","first_posted":"2025-11-19","last_posted":"2025-11-19","notices":1,"due_at":"2026-12-03T22:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"573067270009","latest_notice_id":"ff7a062def984637aae7109d5026d17c","title":"Sources Sought: Polarization-Entangled Photon Source","solicitation_number":"573067-27-0009","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6035","set_aside":null,"state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"NISTSS26CHIPS16","latest_notice_id":"f06db812fc2549fc995d22d26b2dbc5c","title":"Sources Sought Notice for Continuous Wave Parametric Oscillator (CW OPO) Laser System","solicitation_number":"NIST-SS26-CHIPS-16","notice_type":"r","first_type":"r","first_posted":"2025-11-20","last_posted":"2025-11-20","notices":1,"due_at":"2026-12-05T16:00:00Z","due_date":"2026-12-05","closes_at":"2026-12-05T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"1333ND27R0001","latest_notice_id":"bb1373be92d643798f65aae817d7aba0","title":"CUP Preventative Maintenance and Repair, NIST, Boulder, CO","solicitation_number":"1333ND27R0001","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-09T22:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"811310","psc":"Z1JZ","set_aside":"SBA","state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}