Special notice
Optical Spectrum Analyzer
NB685110-25-01261
National Institute of Standards and Technology, Department of Commerce NIST. Analytical Laboratory Instrument Manufacturing.
Response deadline
April 14, 2025 at 5:00 PM EDT
Closed 591 days ago. Posted April 4, 2025. Scheduled to archive April 29, 2025.
Get the next one like this from National Institute of Standards and Technology by email, the day it is posted.Find my opportunities
This one closed in 2025
53 like it are open now in analytical laboratory instrument manufacturing
- Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due tomorrowNov 27 - Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology, Department of Commerce NIST
Sources soughtNAICS 334516Ship to Gaithersburg, MDNIST-MML-FY27-SS01Due in 2 daysNov 28 - Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
Department of the Army, W6QK ACC-APG Adelphi
SolicitationNAICS 334516Ship to MDW911QX27QA015Due in 5 daysDec 1
All 53 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary
Description
As published on SAM.gov.
The National Institute of Standard and Technology (NIST), Sensor Science Division (SSD) requires an optical spectrum analyzer capable of providing accurate measurement of the wavelength and spectrum of an optical source to meet the research and calibration needs of the Division. Procurement of an optical spectrum analyzer (OSA), which meets the specifications described below, will improve wavelength calibration and stray light evaluation over a wide spectral range from the ultraviolet to the near infrared for a variety of optical sources.
This notice is not a request for a quotation. A solicitation document will not be issued and quotations will not be requested.
This acquisition is being conducted under the authority of FAR 13.106-1(b) via FAR 13.106-1(b). The North American Industry Classification System (NAICS) code for this acquisition is 334516, Analytical Laboratory Instrument Manufacturing.
NIST’s SSD requires an OSA for wavelength calibration and stray light evaluation in order to meet the research and calibration needs of the Division. Specifically, NIST requires an OSA that: 1) provides accurate measurement of the wavelength and spectrum of an optical source; 2) compatible for optical sources that consist of lamp-based systems and monochromator, are continuous wave (CW), are on the order of 1 μW, and have bandpass of 1.5 nm to 3 nm; 3) allows for free-space coupling optical source to the OSA; 4) has spectral range of 250 nm to 2500 nm and spectral resolution of ≤ 0.01 nm; and 5) wavelength accuracy of ≤ 0.005 nm and traceable to the International System of Units (SI) meter. After thorough evaluation, it has been determined that only Thorlabs can meet NIST’s requirements for the reasons listed below:
- Only Thorlabs provides an OSA that meets requirements for spectral range (250 nm to 2500 nm). No other manufacturer produces an OSA with capabilities below 350 nm. Additionally, wavelengths longer than 350 nm, multiple instruments would be required to cover the visible, near infrared, and shortwave infrared spectral ranges at greater expense. The Thorlabs OSA meets the requirement with a single instrument.
- The Thorlabs OSA is needed to implement effective, low uncertainty method for calibrating the wavelength scale of the monochromator of the national reference instrument for transmittance, Reference Transmittance Spectrophotometer (RTS). This instrument is provides the national scale for transmittance measurements and is used for the dissemination of the transmittance scale to stakeholders through NIST calibration services. Other common methods for calibration the wavelength scale of a monochromator include the pen-ray method and use of a calibrated array spectroradiometer. The Thorlabs OSA will yield smaller wavelength uncertainties than those obtained by the pen-ray method and eliminate the time required to calibrate and correct an array spectroradiometer.
- Thorlabs is the manufacturer of this OSA and they do not have any third-party resellers.
NIST conducted market research from January 2025 through February 2025 by internet searches, discussions with sources, and a sources sought posting. Sources sought NIST-SS25-11 was posted from January 13, 2025 to January 27, 2025 with no responses. The results of that market research revealed that only Thorlabs, 43 Sparta Ave., Newton, NJ, 07860, United States, UEI: VCJKYBSL8DL8 appears to be capable of meeting NIST’s requirements.
However, any sources that believe they are capable of meeting NIST’s minimum requirements are encouraged to respond to this notice by the response date to provide the following information at a minimum: Company Unique Entity Identifier number in https://sam.gov; details about what your company is capable of providing that meets or exceeds NIST’s minimum requirements; whether your company is an authorized reseller of the product or service being cited and evidence of such authorization; and any other information that can help NIST determine whether this requirement may be competitively satisfied.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 4, 2025
Special notice
Due April 14, 2025 at 5:00 PM EDT. SAM.gov, notice 571277b4121e4dedbeed96747357c439
1 revision on SAM
- April 4, 2025: publish, special notice
Points of contact
- Cielo Ibarracielo.ibarra@nist.gov