Presolicitation
Notice of Intent to Sole Source- Super Resolution Microscope
NB644020-25-01702
National Institute of Standards and Technology, Department of Commerce NIST. Analytical Laboratory Instrument Manufacturing.
Response deadline
August 19, 2025 at 11:00 AM EDT
Closed 464 days ago. Posted August 4, 2025. Scheduled to archive September 3, 2025.
Get the next one like this from National Institute of Standards and Technology by email, the day it is posted.Find my opportunities
This one closed in 2025
55 like it are open now in analytical laboratory instrument manufacturing
- Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due tomorrowNov 27 - Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology, Department of Commerce NIST
Sources soughtNAICS 334516Ship to Gaithersburg, MDNIST-MML-FY27-SS01Due in 2 daysNov 28 - Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
Department of the Army, W6QK ACC-APG Adelphi
SolicitationNAICS 334516Ship to MDW911QX27QA015Due in 5 daysDec 1
All 55 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the presolicitation of August 4, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Notice of Intent to Sole Source
Agency Name: National Institute of Standards and Technology (NIST
Description: The National Institute of Standards and Technology (NIST) intends to award a sole-source contract to Oxford NanoImaging Inc of San Diego CA, for a Super Resolution Microscope. The Biosystems and Biomaterials Division (BBD) of the National Institute of Standards and Technology requires a super-resolution microscopy system for the quantitative, spatial measurement of biological molecules in viruses, viral vectors, biological nanoparticles, and living cells. This need has three critical criteria, one related to the required capabilities and two related to safety, for integration into existing laboratory engineering safety controls and for the laser safety of the system itself. BBD has considered conventional format microscope systems that can deliver the needed measurement capabilities and found none that include both necessary safety criteria. BBD has also considered non-conventional format, integrated microscopy systems and found that only the Oxford Nanoimaging ONI Nanoimager instrument meets all three critical criteria of the Government's need.
Justification: This sole-source procurement is justified under FAR 6.302-1, as Oxford NanoImaging is the only responsible source capable of providing the Super Resolution Microscope due to critical criteria 1, the system must be imaging based with brightfield and fluorescence modes hardware capabilities for 100x magnification, epifluorescence illumination, highly inclined and laminated optical sheet (HILO) fluorescence illumination, and total internal reflectance fluorescence (TIRF) illumination. These criteria are necessary for the single system to be capable of providing required measurements across the nanometer to micrometer length scales presented by the range of biological materials BBD currently needs to measure and characterize. Critical criteria 2, the system must be compatible with placement inside an existing, conventional biological safety cabinet (BSC) within BBD's laboratories. As such, the system must have an overall footprint no larger than 36" x 24" x 20" (w x d x h) to fit within the working volume of the BSC. In addition, the system must be constructed so as not to require any external vibration isolation or stabilization in excess of a placement surface that can support the physical weight of the system with a maximum system weight of 70 kg. These criteria are necessary since the biological materials to be studied by BBD include biological materials at biosafety levels 1 to 2+ and, therefore, require a biosafety enclosure for operator (person) protection during manipulations of the measurement samples. Furthermore, BBD needs to incorporate these new measurement capabilities into an existing laboratory space with one conventional BSC and no capacity to accommodate any measurement instrument-specific biological safety enclosures. Critical criteria 3, the system must operate as a class 1 laser device at all times during user operation. BBD's existing laboratory space for these measurements with biological materials is not equipped with the necessary engineering controls that would allow safe operation of laser devices classified above class 1 during user operation, and such engineering modifications are not currently feasible.
Contact Information: For inquiries, please contact Don Graham, Contracting Officer at donald.graham@nist.gov
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
August 4, 2025
Presolicitation
Due August 19, 2025 at 11:00 AM EDT. SAM.gov, notice 4799bdc4d6ff408389299ae05e3ea820
1 revision on SAM
- August 4, 2025: publish, presolicitation
Points of contact
- Don Grahamdeg@NIST.GOV3019758567