{"canonical":"https://sealedbidder.com/opportunities/n6449825qxxxx","key":"N6449825QXXXX","url":"https://sealedbidder.com/opportunities/n6449825qxxxx","title":"LCS Independence Data Acquisition Units (DAU)","solicitation_number":"N6449825QXXXX","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-06T20:00:00Z","first_posted":"2025-01-14","last_posted":"2025-01-22","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NSWC PHILADELPHIA DIV","naics":"334111","psc":"7B22","set_aside":null,"place_state":"PA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"42101","place_county_name":"Philadelphia County","place_city":"4260000","place_city_name":"Philadelphia","winner":null,"award_amount":null,"publications":[{"notice_id":"3f706d8c17894a639e2c91bfea62f8ef","title":"Request for Information - Network Switch Racks","solicitation_number":"N6449825QXXXX","notice_type":"r","base_type":"r","posted":"2025-01-14","posted_at":"2025-01-14T20:00:59.458Z","due_at":"2025-01-29T20:00:00Z","due_date":"2025-01-29","cancelled":false,"archived":true,"archive_date":"2025-02-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3f706d8c17894a639e2c91bfea62f8ef/view","enriched":true,"history":[{"index":3,"title":"Request for Information - Network Switch Racks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T20:00:59.458Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3f706d8c17894a639e2c91bfea62f8ef","solicitation_number":"N6449825QXXXX"}]},{"notice_id":"5dc7469b70a24ce295e6e15d64fefd5e","title":"LCS Independence Data Acquisition Units (DAU)","solicitation_number":"N6449825QXXXX","notice_type":"k","base_type":"r","posted":"2025-01-22","posted_at":"2025-01-22T12:01:18.746Z","due_at":"2025-02-06T20:00:00Z","due_date":"2025-02-06","cancelled":false,"archived":true,"archive_date":"2025-02-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5dc7469b70a24ce295e6e15d64fefd5e/view","enriched":true,"history":[{"index":6,"title":"LCS Independence Data Acquisition Units (DAU)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-22T12:01:18.746Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5dc7469b70a24ce295e6e15d64fefd5e","solicitation_number":"N6449825QXXXX","related_opportunity_id":"9d5f475799c24af7ad3644a931f14d8a"},{"index":3,"title":"LCS Independence Data Acquisition Units (DAU)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2024-12-18T18:13:13.053Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"9d5f475799c24af7ad3644a931f14d8a","solicitation_number":"N6449824RFPREQPD510221"}]}],"latest_notice_id":"5dc7469b70a24ce295e6e15d64fefd5e","first_type":"r","notices":[{"dates":{"posted":"2025-01-14","posted_at":"2025-01-14T20:00:59.458Z","created_at":"2025-01-14T19:38:40.302Z","modified_at":"2025-02-14T04:55:43.458Z","response_deadline":{"raw":"2025-01-29T15:00:00-05:00","utc":"2025-01-29T20:00:00Z","date":"2025-01-29","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3f706d8c17894a639e2c91bfea62f8ef/view"},"naics":{"codes":["334111"],"primary":"334111"},"title":"Request for Information - Network Switch Racks","agency":{"office":{"code":"N64498","name":"NSWC PHILADELPHIA DIV"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"19112-1403","city":"PHILADELPHIA","state":"PA","country":"USA"},"organization_id":"500020522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-13","archive_type":"auto15"},"history":[{"index":3,"title":"Request for Information - Network Switch Racks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T20:00:59.458Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3f706d8c17894a639e2c91bfea62f8ef","solicitation_number":"N6449825QXXXX"}],"contacts":[{"name":"Shawn M. Waters","role":"primary","email":"shawn.m.waters@navy.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"3f706d8c17894a639e2c91bfea62f8ef","lineage_id":"3f706d8c17894a639e2c91bfea62f8ef","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-25T03:34:30.882819597Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"3837657235a4d1973f7266e6d5d84e7c13082e56ce8ba773131f6537a95d36ce","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-25T03:34:30.882819597Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). The Naval Surface Warfare Center Philadelphia Division (NSWCPD) Navigation Critical Distribution System (NCDS) support team has a requirement for CVN 70 network switch racks. Below are some of the general and form-fit-function (FFF) specific requirements. The Government is seeking all possible solutions/responses to meet this requirement. Responses are sought for existing products that can be modified to fit the Government&rsquo;s need.**this is not a request for purchase order**</p>\n\n<p></p>\n\n<p><u>GENERAL</u></p>\n\n<ul>\n\t<li>Appurtenant equipment to assemble rack and components shall include, but are not limited to, terminal boards, cabling, EMI power filters, labels etc.</li>\n\t<li>Any COTS software/licenses/technical manuals or other data purchased as part of a component purchase shall be provided to the government.</li>\n\t<li>All wiring/cabling installed shall be labeled in plain language to identify component being connected &ndash; eg &ldquo;Power A to Core Network Switch PS 1&rdquo;</li>\n\t<li>Front and Rear Rack rails shall be tapped (threaded not straight/thru holes).</li>\n\t<li>Metal hinges shall be used.</li>\n\t<li>Rack front door and removable side &amp; rear panels shall be lockable.</li>\n\t<li>The design shall ensure that no components or fiber connectors contact front door or rear/side panels when closed.</li>\n\t<li>Shock Isolators shall be included on rack assembly (bottom and sway) when delivered.</li>\n</ul>\n\n<p></p>\n\n<p><u>FFF REQUIREMENTS</u></p>\n\n<p>Weight: The overall weight of the rack shall not exceed 1000 lbs.</p>\n\n<p>Center of Gravity: Center of Gravity (COG) shall be approximately 26.05 in from the bottom of the rack, 12.11 in from the left side of the rack, and 14.58 in from the front of the rack.</p>\n\n<p>Dimensions: External dimensions, including bolt pattern are critical. The dimensions of the rack, including the shock mounts, sway mounts and rigging bolts, shall be 78.75 in. x 24.06 in. x 37.46 in. (Height x Width x Depth) with a maximum shock excursion of 3.5 in. around the entire perimeter of the rack.</p>\n\n<p>Patch Panels: The racks shall include four (4) total fiber optic patch panels with 48 fiber optic ST couplers per patch panel, allowing for 192 total fiber optic termination points.</p>\n\n<p>Uninterruptible Power Supplies (UPS): The racks must include two (2) Uninterruptible Power Supplies capable of providing uninterrupted power to all components inside the rack for a minimum of 30 minutes in the case of a complete loss of power.</p>\n\n<p>Power Distribution Unit (PDU): Power from UPSs shall be distributed to all internal electrical components via PDUs. Internal rack components having redundant power supplies shall have each power supply fed from a different PDU.</p>\n\n<p>Core Network Switch Requirements: 2 Siemens MX5000 *<strong>or equivalent</strong>* switch chassis (MR1),</p>\n\n<p>each having the following module configuration:</p>\n\n<p>Core Switch #1 (Top):</p>\n\n<p>2 AC Power Supplies (MHIF)</p>\n\n<p>1 Control Module (MCM01, L3SEL3HW)</p>\n\n<p>1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)</p>\n\n<p>1 4-port 1000BaseLX Line Module (M4FG03)</p>\n\n<p>4 8-port 100BaseFX Line Modules (M8FX11)</p>\n\n<p>1 16-port 10/100BaseTx Line Module (M16TX01)</p>\n\n<p>Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01</p>\n\n<p></p>\n\n<p>Core Switch #2 (Top):</p>\n\n<p>2 AC Power Supplies (MHIF)</p>\n\n<p>1 Control Module (MCM01, L3SEL3HW)</p>\n\n<p>1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)</p>\n\n<p>1 4-port 1000BaseLX Line Module (M4FG03)</p>\n\n<p>4 8-port 100BaseFX Line Modules (M8FX11)</p>\n\n<p>1 16-port 10/100BaseTx Line Module (M16TX01)</p>\n\n<p>Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01</p>\n\n<p>Each Core Network Switch shall have a minimum of 1U spacing between itself and the rack enclosure or other rack components.</p>\n\n<p></p>\n\n<p>Cable Management Tray:</p>\n\n<p>2U rack height, used to route and cover/store fiber jumper slack</p>\n\n<p>Located below lowest Core Network Switch</p>\n\n<p>Ortronics OR-808044549 or similar.</p>\n\n<p></p>\n\n<p>Rack Mount Sealed PC CPU: The rack-mountable workstations shall adhere to standard Electronics Industries Alliance (EIA) 19 inch rack mounting standards.</p>\n\n<p>Windows 10 or later OS / RHEL 8 or later OS</p>\n\n<p>8GB RAM (threshold), 16 GB RAM (objective)</p>\n\n<p>Minimum 2 RJ45 10/100/1000Base-TX Ethernet ports</p>\n\n<p>Minimum 2x 100Base-FX ports</p>\n\n<p>Minimum of 1 SFP for 1000Base-LX</p>\n\n<p>Minimum 1 SVGA, 1 DVI and 1 DisplayPort or HDMI</p>\n\n<p>Locking front cover with any ports and on/off button covered with common key currently used within US Navy Fleet.</p>\n\n<p>Capable of using installed KVM and display</p>\n\n<p>Sealed &ndash; no fans</p>\n\n<p>0-60C operating range minimum.</p>\n\n<p>2x 500GB solid state removable hard drives minimum</p>\n\n<p>USB ports front and rear (qty 2 min front qty 2 rear min)</p>\n\n<p>2U Max Height</p>\n\n<p>Shall be able to be serviced without having to remove from rack.</p>\n\n<p>3.10 Pull Out Keyboard/Trackball/Display:</p>\n\n<p>1U pull out keyboard Trackball and Display for Rack Mount Sealed PC CPU</p>\n\n<p>Must be able to pull out and lock into place and open screen at least to 90degree perpendicular to keyboard.</p>\n\n<p></p>\n\n<p>Modular Master Clock: Brandywine Modular Master Clock *<strong>or equivalent</strong>* having the following module configuration:</p>\n\n<p>2 AC Power Supply Modules (033000014)</p>\n\n<p>2 Modular Master Clock Rubidium Oscillator Assemblies (033000004)</p>\n\n<p>2 Modular Master Clock Modules (033000003)</p>\n\n<p>1 Optical Crosslink Module (033000011)</p>\n\n<p>1 NTP Server Module (033000015)</p>\n\n<p>10 Universal Output Signal Modules (033000010)</p>\n\n<p>3.12 Ship Control System (SCS) Network Switch (CVN Configuration Only):</p>\n\n<p>1 Siemens MX5000 switch chassis (MR1), having the following module configuration:</p>\n\n<p>2 AC Power Supplies (MHIF)</p>\n\n<p>1 Control Module (MCM01)</p>\n\n<p>1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)</p>\n\n<p>6 8-port 100BaseFX Line Modules (M8FX11)</p>\n\n<p>Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G04+H04+J04</p>\n\n<p></p>\n\n<p>Environmental Qualification Testing: Network Switch Racks shall meet shock (MIL-DTL-901), vibration (MIL-STD-167), and EMI (MIL-STD-461).</p>\n\n<p>Final rack assembly (including all internal components in their service mounting positions) shall be designed to meet all requirements of the Referenced Documents including vibration, shock, EMC, temperature, humidity, fungus, and inclination. If not previously referenced in this document, the latest revision of the following shall apply as minimum standards:</p>\n\n<p>Shock: MIL-S-901 Grade A</p>\n\n<p>Vibration: MIL-STD-167</p>\n\n<p>EMC: MIL-STD-461</p>\n\n<p>Operating Temperature: 0-50oC (objective) 45 oC (threshold), MIL-STD-810</p>\n\n<p>Non-operating Temperature: -40 - 70oC, MIL-STD-810</p>\n\n<p>Relative Humidity: 10 &ndash; 90% non-condensing, MIL-STD-810</p>\n\n<p>Salt fog and fungus: MIL-STD-810</p>","text":"THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). The Naval Surface Warfare Center Philadelphia Division (NSWCPD) Navigation Critical Distribution System (NCDS) support team has a requirement for CVN 70 network switch racks. Below are some of the general and form-fit-function (FFF) specific requirements. The Government is seeking all possible solutions/responses to meet this requirement. Responses are sought for existing products that can be modified to fit the Government’s need.**this is not a request for purchase order**\n\nGENERAL\n\n• Appurtenant equipment to assemble rack and components shall include, but are not limited to, terminal boards, cabling, EMI power filters, labels etc.\n\n• Any COTS software/licenses/technical manuals or other data purchased as part of a component purchase shall be provided to the government.\n\n• All wiring/cabling installed shall be labeled in plain language to identify component being connected – eg “Power A to Core Network Switch PS 1”\n\n• Front and Rear Rack rails shall be tapped (threaded not straight/thru holes).\n\n• Metal hinges shall be used.\n\n• Rack front door and removable side & rear panels shall be lockable.\n\n• The design shall ensure that no components or fiber connectors contact front door or rear/side panels when closed.\n\n• Shock Isolators shall be included on rack assembly (bottom and sway) when delivered.\n\nFFF REQUIREMENTS\n\nWeight: The overall weight of the rack shall not exceed 1000 lbs.\n\nCenter of Gravity: Center of Gravity (COG) shall be approximately 26.05 in from the bottom of the rack, 12.11 in from the left side of the rack, and 14.58 in from the front of the rack.\n\nDimensions: External dimensions, including bolt pattern are critical. The dimensions of the rack, including the shock mounts, sway mounts and rigging bolts, shall be 78.75 in. x 24.06 in. x 37.46 in. (Height x Width x Depth) with a maximum shock excursion of 3.5 in. around the entire perimeter of the rack.\n\nPatch Panels: The racks shall include four (4) total fiber optic patch panels with 48 fiber optic ST couplers per patch panel, allowing for 192 total fiber optic termination points.\n\nUninterruptible Power Supplies (UPS): The racks must include two (2) Uninterruptible Power Supplies capable of providing uninterrupted power to all components inside the rack for a minimum of 30 minutes in the case of a complete loss of power.\n\nPower Distribution Unit (PDU): Power from UPSs shall be distributed to all internal electrical components via PDUs. Internal rack components having redundant power supplies shall have each power supply fed from a different PDU.\n\nCore Network Switch Requirements: 2 Siemens MX5000 *or equivalent* switch chassis (MR1),\n\neach having the following module configuration:\n\nCore Switch #1 (Top):\n\n2 AC Power Supplies (MHIF)\n\n1 Control Module (MCM01, L3SEL3HW)\n\n1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)\n\n1 4-port 1000BaseLX Line Module (M4FG03)\n\n4 8-port 100BaseFX Line Modules (M8FX11)\n\n1 16-port 10/100BaseTx Line Module (M16TX01)\n\nFull MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01\n\nCore Switch #2 (Top):\n\n2 AC Power Supplies (MHIF)\n\n1 Control Module (MCM01, L3SEL3HW)\n\n1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)\n\n1 4-port 1000BaseLX Line Module (M4FG03)\n\n4 8-port 100BaseFX Line Modules (M8FX11)\n\n1 16-port 10/100BaseTx Line Module (M16TX01)\n\nFull MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01\n\nEach Core Network Switch shall have a minimum of 1U spacing between itself and the rack enclosure or other rack components.\n\nCable Management Tray:\n\n2U rack height, used to route and cover/store fiber jumper slack\n\nLocated below lowest Core Network Switch\n\nOrtronics OR-808044549 or similar.\n\nRack Mount Sealed PC CPU: The rack-mountable workstations shall adhere to standard Electronics Industries Alliance (EIA) 19 inch rack mounting standards.\n\nWindows 10 or later OS / RHEL 8 or later OS\n\n8GB RAM (threshold), 16 GB RAM (objective)\n\nMinimum 2 RJ45 10/100/1000Base-TX Ethernet ports\n\nMinimum 2x 100Base-FX ports\n\nMinimum of 1 SFP for 1000Base-LX\n\nMinimum 1 SVGA, 1 DVI and 1 DisplayPort or HDMI\n\nLocking front cover with any ports and on/off button covered with common key currently used within US Navy Fleet.\n\nCapable of using installed KVM and display\n\nSealed – no fans\n\n0-60C operating range minimum.\n\n2x 500GB solid state removable hard drives minimum\n\nUSB ports front and rear (qty 2 min front qty 2 rear min)\n\n2U Max Height\n\nShall be able to be serviced without having to remove from rack.\n\n3.10 Pull Out Keyboard/Trackball/Display:\n\n1U pull out keyboard Trackball and Display for Rack Mount Sealed PC CPU\n\nMust be able to pull out and lock into place and open screen at least to 90degree perpendicular to keyboard.\n\nModular Master Clock: Brandywine Modular Master Clock *or equivalent* having the following module configuration:\n\n2 AC Power Supply Modules (033000014)\n\n2 Modular Master Clock Rubidium Oscillator Assemblies (033000004)\n\n2 Modular Master Clock Modules (033000003)\n\n1 Optical Crosslink Module (033000011)\n\n1 NTP Server Module (033000015)\n\n10 Universal Output Signal Modules (033000010)\n\n3.12 Ship Control System (SCS) Network Switch (CVN Configuration Only):\n\n1 Siemens MX5000 switch chassis (MR1), having the following module configuration:\n\n2 AC Power Supplies (MHIF)\n\n1 Control Module (MCM01)\n\n1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)\n\n6 8-port 100BaseFX Line Modules (M8FX11)\n\nFull MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G04+H04+J04\n\nEnvironmental Qualification Testing: Network Switch Racks shall meet shock (MIL-DTL-901), vibration (MIL-STD-167), and EMI (MIL-STD-461).\n\nFinal rack assembly (including all internal components in their service mounting positions) shall be designed to meet all requirements of the Referenced Documents including vibration, shock, EMC, temperature, humidity, fungus, and inclination. If not previously referenced in this document, the latest revision of the following shall apply as minimum standards:\n\nShock: MIL-S-901 Grade A\n\nVibration: MIL-STD-167\n\nEMC: MIL-STD-461\n\nOperating Temperature: 0-50oC (objective) 45 oC (threshold), MIL-STD-810\n\nNon-operating Temperature: -40 - 70oC, MIL-STD-810\n\nRelative Humidity: 10 – 90% non-condensing, MIL-STD-810\n\nSalt fog and fungus: MIL-STD-810","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"N6449825QXXXX","place_of_performance":{"zip":"19112","city":{"code":"60000","name":"Philadelphia"},"state":{"code":"PA","name":"Pennsylvania"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"7H20"},{"dates":{"posted":"2025-01-22","posted_at":"2025-01-22T12:01:18.746Z","created_at":"2025-01-22T11:51:51.132Z","modified_at":"2025-02-22T04:55:43.509Z","response_deadline":{"raw":"2025-02-06T15:00:00-05:00","utc":"2025-02-06T20:00:00Z","date":"2025-02-06","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5dc7469b70a24ce295e6e15d64fefd5e/view"},"naics":{"codes":["334111"],"primary":"334111"},"title":"LCS Independence Data Acquisition Units (DAU)","agency":{"office":{"code":"N64498","name":"NSWC PHILADELPHIA DIV"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"19112-1403","city":"PHILADELPHIA","state":"PA","country":"USA"},"organization_id":"500020522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-21","archive_type":"auto15"},"history":[{"index":6,"title":"LCS Independence Data Acquisition Units (DAU)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-22T12:01:18.746Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5dc7469b70a24ce295e6e15d64fefd5e","solicitation_number":"N6449825QXXXX","related_opportunity_id":"9d5f475799c24af7ad3644a931f14d8a"},{"index":3,"title":"LCS Independence Data Acquisition Units (DAU)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2024-12-18T18:13:13.053Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"9d5f475799c24af7ad3644a931f14d8a","solicitation_number":"N6449824RFPREQPD510221"}],"contacts":[{"name":"Jillian Randazzo","role":"primary","email":"jillian.randazzo.civ@us.navy.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"5dc7469b70a24ce295e6e15d64fefd5e","lineage_id":"9d5f475799c24af7ad3644a931f14d8a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T11:45:51.221480282Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"7cee1003582246ca0a386a26be6c5d50c326b6d3591a79794cdd8fa6c9ae8e7b","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T11:45:51.221480282Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>The Naval Surface Warfare Center Philadelphia intends to procure LCS Independence Data Acquisition Units (DAU) Panels on a Sole Source basis from Siemens.</p>\n\n<p>The proposed contract action is for supplies or services for which the Government intends to solicit and award with only one source under authority of FAR 13.106 (b).</p>\n\n<p>Any questions regarding this notice should be emailed to: shawn.m.waters11.civ@us.navy.mil<br />\nPhone calls will NOT be accepted.</p>\n\n<p></p>\n\n<p></p>","text":"The Naval Surface Warfare Center Philadelphia intends to procure LCS Independence Data Acquisition Units (DAU) Panels on a Sole Source basis from Siemens.\n\nThe proposed contract action is for supplies or services for which the Government intends to solicit and award with only one source under authority of FAR 13.106 (b).\n\nAny questions regarding this notice should be emailed to: shawn.m.waters11.civ@us.navy.mil\n\nPhone calls will NOT be accepted.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"N6449825QXXXX","place_of_performance":{"zip":"19112","city":{"code":"60000","name":"Philadelphia"},"state":{"code":"PA","name":"Pennsylvania"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"7B22"}],"due_at":"2025-02-06T20:00:00Z","due_date":"2025-02-06","closes_at":"2025-02-06T20:00:00Z","awardable":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-24T12:35:06.945492Z","principal_notice_id":"5dc7469b70a24ce295e6e15d64fefd5e","description":{"text":"The Naval Surface Warfare Center Philadelphia intends to procure LCS Independence Data Acquisition Units (DAU) Panels on a Sole Source basis from Siemens.\n\nThe proposed contract action is for supplies or services for which the Government intends to solicit and award with only one source under authority of FAR 13.106 (b).\n\nAny questions regarding this notice should be emailed to: shawn.m.waters11.civ@us.navy.mil\n\nPhone calls will NOT be accepted.","html":"<p>The Naval Surface Warfare Center Philadelphia intends to procure LCS Independence Data Acquisition Units (DAU) Panels on a Sole Source basis from Siemens.</p>\n\n<p>The proposed contract action is for supplies or services for which the Government intends to solicit and award with only one source under authority of FAR 13.106 (b).</p>\n\n<p>Any questions regarding this notice should be emailed to: shawn.m.waters11.civ@us.navy.mil<br />\nPhone calls will NOT be accepted.</p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Jillian Randazzo","role":"primary","email":"jillian.randazzo.civ@us.navy.mil"}],"place_of_performance":{"zip":"19112","city":{"code":"60000","name":"Philadelphia"},"state":{"code":"PA","name":"Pennsylvania"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"19112-1403","city":"PHILADELPHIA","state":"PA","country":"USA"},"naics_codes":["334111"],"award":null,"attachments":[],"awards":[],"related":[{"key":"N6449827SIMACQPD600004","latest_notice_id":"fcc91441ccb349d0ae83f9af13f18275","title":"Portable Vibration Monitoring System","solicitation_number":"N64498-27-SIMACQ-PD-60-0004","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"334515","psc":"6625","set_aside":null,"state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N6449827Q0009","latest_notice_id":"9167089ff2304258ac4a9daebeceb25c","title":"Shipping Tarps","solicitation_number":"N6449827Q0009","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-25","notices":2,"due_at":"2026-12-02T08:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T08:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"314999","psc":"8340","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8340)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"N6449826Q0054","latest_notice_id":"0c2cbcf93dfc432aab7790af1f47ed6f","title":"**Big Blue 3 MAC** Metal printer alterations will be completed onboard USS IWA JIMA (LHD 7), USS BOXER (LHD 4), LHD 8 (USS MAKIN ISLAND)","solicitation_number":"N6449826Q0054","notice_type":"o","first_type":"o","first_posted":"2026-09-30","last_posted":"2026-11-16","notices":6,"due_at":"2026-12-02T18:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"336611","psc":"R425","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"N6449827Q0005","latest_notice_id":"759706ecaed549b1990a980bca2c9801","title":"Big Blue MAC MACHALT FY27-FY28 MA668/MA688/MA738/MA739","solicitation_number":"N6449827Q0005","notice_type":"o","first_type":"o","first_posted":"2026-10-22","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"336611","psc":"R425","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N6449826R0547","latest_notice_id":"a4b0b949fd3c4f8fbc9c1cebcd1c5b2b","title":"**SOLE SOURCE RFP to Bird-Johnson Propeller Company** Navy Propulsor and Propellers","solicitation_number":"N6449826R0547","notice_type":"o","first_type":"o","first_posted":"2026-09-14","last_posted":"2026-11-02","notices":3,"due_at":"2026-12-03T18:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"333618","psc":"J030","set_aside":null,"state":"MA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"110 NORFOLK STREETWALPOLE, MA 02081","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-03T04:52:39.433634Z"}],"similar_open":[{"key":"SPE7M527U0082","latest_notice_id":"d6e06ef1253849f3bc911b5f1015bcb9","title":"59--ELECTRONIC MODULE,STAN","solicitation_number":"SPE7M527U0082","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M5","office_name":"DLA WEAPONS SUPPORT","naics":"334111","psc":"59","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"NTITY WILL BE 7. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"19PK4027Q5004","latest_notice_id":"8f5a7d9814ae4e949a2526a8caf3c1a6","title":"Supply of PD equipment","solicitation_number":"19PK4027Q5004","notice_type":"o","first_type":"o","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-30T10:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T10:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-019","dept_name":"STATE, DEPARTMENT OF","sub_key":"s-1900","sub_name":"STATE, DEPARTMENT OF","office_key":"o-19PK40","office_name":"AMERICAN CONSULATE KARACHI","naics":"334111","psc":"7520","set_aside":null,"state":"NJ","county":"34023","county_name":"Middlesex County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"FA822227Q1593","latest_notice_id":"f1e9a103e4db4794b7e4b551ef7c2343","title":"Dell PowerEdge R7725 Rackmount Server","solicitation_number":"FA8222-27-Q-1593","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-24","notices":4,"due_at":"2026-12-02T07:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T07:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8222","office_name":"FA8222 AFSC OL H PZIE","naics":"334111","psc":"7B22","set_aside":"SBA","state":"UT","county":"49011","county_name":"Davis County","city":"4974810","city_name":"Syracuse","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open_total":11,"indexable":false}