{"canonical":"https://sealedbidder.com/opportunities/n6449825p510122","key":"N6449825P510122","url":"https://sealedbidder.com/opportunities/n6449825p510122","title":"Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)","solicitation_number":"N6449825P510122","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-12T19:00:00Z","first_posted":"2025-03-28","last_posted":"2025-03-28","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NSWC PHILADELPHIA DIV","naics":"541511","psc":"7A20","set_aside":null,"place_state":"PA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"42101","place_county_name":"Philadelphia County","place_city":"4260000","place_city_name":"Philadelphia","winner":null,"award_amount":null,"publications":[{"notice_id":"ddf76723ee404ebcb9c3ca725cde3764","title":"Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)","solicitation_number":"N6449825P510122","notice_type":"r","base_type":"r","posted":"2025-03-28","posted_at":"2025-03-28T14:58:15.775Z","due_at":"2025-04-12T19:00:00Z","due_date":"2025-04-12","cancelled":false,"archived":true,"archive_date":"2025-04-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ddf76723ee404ebcb9c3ca725cde3764/view","enriched":true,"history":[{"index":3,"title":"Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-28T14:58:15.775Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ddf76723ee404ebcb9c3ca725cde3764","solicitation_number":"N6449825P510122"}]}],"latest_notice_id":"ddf76723ee404ebcb9c3ca725cde3764","first_type":"r","notices":[{"dates":{"posted":"2025-03-28","posted_at":"2025-03-28T14:58:15.775Z","created_at":"2025-03-28T14:42:05.676Z","modified_at":"2025-04-27T04:04:40.171Z","response_deadline":{"raw":"2025-04-12T15:00:00-04:00","utc":"2025-04-12T19:00:00Z","date":"2025-04-12","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ddf76723ee404ebcb9c3ca725cde3764/view"},"naics":{"codes":["541511"],"primary":"541511"},"title":"Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)","agency":{"office":{"code":"N64498","name":"NSWC PHILADELPHIA DIV"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"19112-1403","city":"PHILADELPHIA","state":"PA","country":"USA"},"organization_id":"500020522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-27","archive_type":"auto15"},"history":[{"index":3,"title":"Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-28T14:58:15.775Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ddf76723ee404ebcb9c3ca725cde3764","solicitation_number":"N6449825P510122"}],"contacts":[{"name":"Stefan Kitzinger","role":"primary","email":"stefan.b.kitzinger.civ@us.navy.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"ddf76723ee404ebcb9c3ca725cde3764","lineage_id":"ddf76723ee404ebcb9c3ca725cde3764","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T12:22:37.484242603Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"48fa6c3da5e9f16727a8ab9f9f1edb47aa3740b22e51b1ed8063ef3e1cd0575b","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T12:22:37.484242603Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>RFI</p>\n\n<p></p>\n\n<p>THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). NSWCPD has a requirement for Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)</p>\n\n<p></p>\n\n<p>The Contractor shall provide Non-Recurring Engineering (NRE) support services to further the development of fire alarm control panel and complete the following objectives:</p>\n\n<p></p>\n\n<ol>\n\t<li>Enhance the FX-4000N platform by incorporating dual temperature trigger points for the System Sensor 5251 Heat Detector when used with the ALCN-4792MISO loop adder in CLIP mode. Introduce two reporting thresholds based on pulse width measurements:</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>600-1400 &micro;s = Normal</li>\n\t\t<li>1401-1750 &micro;s = 105&deg;F Alarm</li>\n\t\t<li>Above 1751 &micro;s = 125&deg;F Alarm</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p>These thresholds align with the sensitivity specifications provided by System Sensor, allowing a tolerance level of &plusmn;50 &mu;s (pulse width) or approximately &plusmn;3-4&deg;F. The system will adhere to the standard alarm temperature settings of 105&deg;F (standard) and 125&deg;F (high temperature)</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>Currently, the configuration tool from Securiplex supports defining alarm points between 35&deg;F and 189&deg;F. This project will ensure compatibility and accurate temperature reporting within this range.</p>\n\n<p></p>\n\n<ol>\n\t<li>Remove lockout feature from MGC-4000 configuration that denies user access to the panel after five (5) failed password attempts</li>\n</ol>\n\n<p></p>\n\n<p>The LHD/A MCS Team will take ownership of the completed deliverables and retain the right to use said deliverables through the consideration of a suitable manufacturer. The Contractor shall acknowledge that they retain no right to the completed deliverables.</p>\n\n<p></p>\n\n<p><strong>APPLICABLE DOCUMENTS </strong></p>\n\n<ul>\n\t<li>Navy Issuances</li>\n</ul>\n\n<p>https://www.secnav.navy.mil/doni/default.aspx</p>\n\n<ul>\n\t<li>DOD Issuances</li>\n</ul>\n\n<p>https://www.defense.gov/Resources/Forms-Directives-Instructions/</p>\n\n<ul>\n\t<li>NAVSEAINST Library</li>\n</ul>\n\n<p>https://www.navsea.navy.mil/Resources/Instructions/</p>\n\n<p></p>\n\n<p>The Contractor shall reference and utilize the latest version available when performing tasks within this PWS.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>REQUIREMENTS</strong></p>\n\n<p></p>\n\n<ol>\n\t<li>Contractor shall enhance the FX-4000N platform by incorporating dual temperature trigger points through the completion of the following phases:</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Requirement Specification &amp; Feasibility Study\n\t\t<ol>\n\t\t\t<li>Define firmware and configurator change requirements.</li>\n\t\t\t<li>Conduct an exploratory study and initial testing on 5251 System sensor heat sensors.</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Firmware &amp; Configurator Development\n\t\t<ol>\n\t\t\t<li>Develop and implement necessary changes in firmware and the configurator.</li>\n\t\t\t<li>Conduct QA testing to ensure accurate reporting and compliance with specifications.</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>Contractor shall modify the MGC-4000 lockout configuration through the completion of the following phases:</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Upgrade the MGC-4000 configuration locking mechanism for US Navy panel.</li>\n\t\t<li>Update firmware and configurator accordingly.</li>\n\t\t<li>Perform Internal QA testing for validation of locking mechanism.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p><strong>CDRLS</strong></p>\n\n<p></p>\n\n<p>Status Report: (CDRL A001)<strong> - </strong>Contractor shall provide status reports as needed.</p>\n\n<p></p>\n\n<p></p>\n\n<p>SUBMISSION OF RESPONSES: Responses shall include specific details regarding the ability to provide the required items to meet the needs of the Government. Responses shall discuss how your product/service will meet the requirements.&nbsp;</p>\n\n<p></p>\n\n<p>Responses are not to exceed two (2) pages. Responses shall be in electronic format.&nbsp; A cover page for the response shall be included. The cover page shall include the company name, address, CAGE Code, Business Size Status for the North American Industry Classification System (NAICS) code of this RFI and points of contract (names, email, and telephone numbers) at a minimum.&nbsp; The cover page is not considered in the total page count.</p>\n\n<p></p>\n\n<p>NSWCPD will accept only electronic unclassified submission of responses. Responses shall be sent to Stefan Kitzinger at stefan.b.kitzinger.civ@us.navy.mil with the subject line &quot;RFI N6449825P510122.&quot; All responses shall be unclassified and submitted no later than 03:00 PM EST on 12 April 2025.</p>\n\n<p></p>\n\n<p>This RFI is for market research purposes only and does NOT constitute a Request for Proposal (RFP).&nbsp; This notice shall not be construed as a contract, a promise to contract, or as a commitment of any kind by the Government.&nbsp; The Government is NOT seeking or accepting unsolicited proposals.&nbsp; This RFI Notice is issued solely for conducting market research in accordance with FAR Part 10 and gathering information for planning purposes.</p>\n\n<p></p>\n\n<p>The Government WILL NOT PAY for any information received in response to this RFI, and the Government will not compensate the respondent for any cost incurred in developing the response to this RFI. The Government will not release any information marked with a proprietary legend received in response to this RFI to any firms, agencies or individuals outside the Government without written permission in accordance with the legend. Please be advised that all submissions become Government property and will not be returned. PHONE CALLS WILL NOT BE ACCEPTED.</p>\n\n<p></p>\n\n<p></p>","text":"RFI\n\nTHIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). NSWCPD has a requirement for Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)\n\nThe Contractor shall provide Non-Recurring Engineering (NRE) support services to further the development of fire alarm control panel and complete the following objectives:\n\n• Enhance the FX-4000N platform by incorporating dual temperature trigger points for the System Sensor 5251 Heat Detector when used with the ALCN-4792MISO loop adder in CLIP mode. Introduce two reporting thresholds based on pulse width measurements:\n\n•\n\n• 600-1400 µs = Normal\n\n• 1401-1750 µs = 105°F Alarm\n\n• Above 1751 µs = 125°F Alarm\n\nThese thresholds align with the sensitivity specifications provided by System Sensor, allowing a tolerance level of ±50 μs (pulse width) or approximately ±3-4°F. The system will adhere to the standard alarm temperature settings of 105°F (standard) and 125°F (high temperature)\n\nCurrently, the configuration tool from Securiplex supports defining alarm points between 35°F and 189°F. This project will ensure compatibility and accurate temperature reporting within this range.\n\n• Remove lockout feature from MGC-4000 configuration that denies user access to the panel after five (5) failed password attempts\n\nThe LHD/A MCS Team will take ownership of the completed deliverables and retain the right to use said deliverables through the consideration of a suitable manufacturer. The Contractor shall acknowledge that they retain no right to the completed deliverables.\n\nAPPLICABLE DOCUMENTS\n\n• Navy Issuances\n\nhttps://www.secnav.navy.mil/doni/default.aspx\n\n• DOD Issuances\n\nhttps://www.defense.gov/Resources/Forms-Directives-Instructions/\n\n• NAVSEAINST Library\n\nhttps://www.navsea.navy.mil/Resources/Instructions/\n\nThe Contractor shall reference and utilize the latest version available when performing tasks within this PWS.\n\nREQUIREMENTS\n\n• Contractor shall enhance the FX-4000N platform by incorporating dual temperature trigger points through the completion of the following phases:\n\n•\n\n• Requirement Specification & Feasibility Study\n\n• Define firmware and configurator change requirements.\n\n• Conduct an exploratory study and initial testing on 5251 System sensor heat sensors.\n\n•\n\n• Firmware & Configurator Development\n\n• Develop and implement necessary changes in firmware and the configurator.\n\n• Conduct QA testing to ensure accurate reporting and compliance with specifications.\n\n• Contractor shall modify the MGC-4000 lockout configuration through the completion of the following phases:\n\n•\n\n• Upgrade the MGC-4000 configuration locking mechanism for US Navy panel.\n\n• Update firmware and configurator accordingly.\n\n• Perform Internal QA testing for validation of locking mechanism.\n\nCDRLS\n\nStatus Report: (CDRL A001) - Contractor shall provide status reports as needed.\n\nSUBMISSION OF RESPONSES: Responses shall include specific details regarding the ability to provide the required items to meet the needs of the Government. Responses shall discuss how your product/service will meet the requirements.\n\nResponses are not to exceed two (2) pages. Responses shall be in electronic format. A cover page for the response shall be included. The cover page shall include the company name, address, CAGE Code, Business Size Status for the North American Industry Classification System (NAICS) code of this RFI and points of contract (names, email, and telephone numbers) at a minimum. The cover page is not considered in the total page count.\n\nNSWCPD will accept only electronic unclassified submission of responses. Responses shall be sent to Stefan Kitzinger at stefan.b.kitzinger.civ@us.navy.mil with the subject line \"RFI N6449825P510122.\" All responses shall be unclassified and submitted no later than 03:00 PM EST on 12 April 2025.\n\nThis RFI is for market research purposes only and does NOT constitute a Request for Proposal (RFP). This notice shall not be construed as a contract, a promise to contract, or as a commitment of any kind by the Government. The Government is NOT seeking or accepting unsolicited proposals. This RFI Notice is issued solely for conducting market research in accordance with FAR Part 10 and gathering information for planning purposes.\n\nThe Government WILL NOT PAY for any information received in response to this RFI, and the Government will not compensate the respondent for any cost incurred in developing the response to this RFI. The Government will not release any information marked with a proprietary legend received in response to this RFI to any firms, agencies or individuals outside the Government without written permission in accordance with the legend. Please be advised that all submissions become Government property and will not be returned. PHONE CALLS WILL NOT BE ACCEPTED.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"N6449825P510122","place_of_performance":{"city":{"code":"60000","name":"Philadelphia"},"state":{"code":"PA","name":"Pennsylvania"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"7A20"}],"due_at":"2025-04-12T19:00:00Z","due_date":"2025-04-12","closes_at":"2025-04-12T19:00:00Z","awardable":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-19T12:56:39.825423Z","principal_notice_id":"ddf76723ee404ebcb9c3ca725cde3764","description":{"text":"RFI\n\nTHIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). NSWCPD has a requirement for Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)\n\nThe Contractor shall provide Non-Recurring Engineering (NRE) support services to further the development of fire alarm control panel and complete the following objectives:\n\n• Enhance the FX-4000N platform by incorporating dual temperature trigger points for the System Sensor 5251 Heat Detector when used with the ALCN-4792MISO loop adder in CLIP mode. Introduce two reporting thresholds based on pulse width measurements:\n\n•\n\n• 600-1400 µs = Normal\n\n• 1401-1750 µs = 105°F Alarm\n\n• Above 1751 µs = 125°F Alarm\n\nThese thresholds align with the sensitivity specifications provided by System Sensor, allowing a tolerance level of ±50 μs (pulse width) or approximately ±3-4°F. The system will adhere to the standard alarm temperature settings of 105°F (standard) and 125°F (high temperature)\n\nCurrently, the configuration tool from Securiplex supports defining alarm points between 35°F and 189°F. This project will ensure compatibility and accurate temperature reporting within this range.\n\n• Remove lockout feature from MGC-4000 configuration that denies user access to the panel after five (5) failed password attempts\n\nThe LHD/A MCS Team will take ownership of the completed deliverables and retain the right to use said deliverables through the consideration of a suitable manufacturer. The Contractor shall acknowledge that they retain no right to the completed deliverables.\n\nAPPLICABLE DOCUMENTS\n\n• Navy Issuances\n\nhttps://www.secnav.navy.mil/doni/default.aspx\n\n• DOD Issuances\n\nhttps://www.defense.gov/Resources/Forms-Directives-Instructions/\n\n• NAVSEAINST Library\n\nhttps://www.navsea.navy.mil/Resources/Instructions/\n\nThe Contractor shall reference and utilize the latest version available when performing tasks within this PWS.\n\nREQUIREMENTS\n\n• Contractor shall enhance the FX-4000N platform by incorporating dual temperature trigger points through the completion of the following phases:\n\n•\n\n• Requirement Specification & Feasibility Study\n\n• Define firmware and configurator change requirements.\n\n• Conduct an exploratory study and initial testing on 5251 System sensor heat sensors.\n\n•\n\n• Firmware & Configurator Development\n\n• Develop and implement necessary changes in firmware and the configurator.\n\n• Conduct QA testing to ensure accurate reporting and compliance with specifications.\n\n• Contractor shall modify the MGC-4000 lockout configuration through the completion of the following phases:\n\n•\n\n• Upgrade the MGC-4000 configuration locking mechanism for US Navy panel.\n\n• Update firmware and configurator accordingly.\n\n• Perform Internal QA testing for validation of locking mechanism.\n\nCDRLS\n\nStatus Report: (CDRL A001) - Contractor shall provide status reports as needed.\n\nSUBMISSION OF RESPONSES: Responses shall include specific details regarding the ability to provide the required items to meet the needs of the Government. Responses shall discuss how your product/service will meet the requirements.\n\nResponses are not to exceed two (2) pages. Responses shall be in electronic format. A cover page for the response shall be included. The cover page shall include the company name, address, CAGE Code, Business Size Status for the North American Industry Classification System (NAICS) code of this RFI and points of contract (names, email, and telephone numbers) at a minimum. The cover page is not considered in the total page count.\n\nNSWCPD will accept only electronic unclassified submission of responses. Responses shall be sent to Stefan Kitzinger at stefan.b.kitzinger.civ@us.navy.mil with the subject line \"RFI N6449825P510122.\" All responses shall be unclassified and submitted no later than 03:00 PM EST on 12 April 2025.\n\nThis RFI is for market research purposes only and does NOT constitute a Request for Proposal (RFP). This notice shall not be construed as a contract, a promise to contract, or as a commitment of any kind by the Government. The Government is NOT seeking or accepting unsolicited proposals. This RFI Notice is issued solely for conducting market research in accordance with FAR Part 10 and gathering information for planning purposes.\n\nThe Government WILL NOT PAY for any information received in response to this RFI, and the Government will not compensate the respondent for any cost incurred in developing the response to this RFI. The Government will not release any information marked with a proprietary legend received in response to this RFI to any firms, agencies or individuals outside the Government without written permission in accordance with the legend. Please be advised that all submissions become Government property and will not be returned. PHONE CALLS WILL NOT BE ACCEPTED.","html":"<p>RFI</p>\n\n<p></p>\n\n<p>THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). NSWCPD has a requirement for Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)</p>\n\n<p></p>\n\n<p>The Contractor shall provide Non-Recurring Engineering (NRE) support services to further the development of fire alarm control panel and complete the following objectives:</p>\n\n<p></p>\n\n<ol>\n\t<li>Enhance the FX-4000N platform by incorporating dual temperature trigger points for the System Sensor 5251 Heat Detector when used with the ALCN-4792MISO loop adder in CLIP mode. Introduce two reporting thresholds based on pulse width measurements:</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>600-1400 &micro;s = Normal</li>\n\t\t<li>1401-1750 &micro;s = 105&deg;F Alarm</li>\n\t\t<li>Above 1751 &micro;s = 125&deg;F Alarm</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p>These thresholds align with the sensitivity specifications provided by System Sensor, allowing a tolerance level of &plusmn;50 &mu;s (pulse width) or approximately &plusmn;3-4&deg;F. The system will adhere to the standard alarm temperature settings of 105&deg;F (standard) and 125&deg;F (high temperature)</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>Currently, the configuration tool from Securiplex supports defining alarm points between 35&deg;F and 189&deg;F. This project will ensure compatibility and accurate temperature reporting within this range.</p>\n\n<p></p>\n\n<ol>\n\t<li>Remove lockout feature from MGC-4000 configuration that denies user access to the panel after five (5) failed password attempts</li>\n</ol>\n\n<p></p>\n\n<p>The LHD/A MCS Team will take ownership of the completed deliverables and retain the right to use said deliverables through the consideration of a suitable manufacturer. The Contractor shall acknowledge that they retain no right to the completed deliverables.</p>\n\n<p></p>\n\n<p><strong>APPLICABLE DOCUMENTS </strong></p>\n\n<ul>\n\t<li>Navy Issuances</li>\n</ul>\n\n<p>https://www.secnav.navy.mil/doni/default.aspx</p>\n\n<ul>\n\t<li>DOD Issuances</li>\n</ul>\n\n<p>https://www.defense.gov/Resources/Forms-Directives-Instructions/</p>\n\n<ul>\n\t<li>NAVSEAINST Library</li>\n</ul>\n\n<p>https://www.navsea.navy.mil/Resources/Instructions/</p>\n\n<p></p>\n\n<p>The Contractor shall reference and utilize the latest version available when performing tasks within this PWS.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>REQUIREMENTS</strong></p>\n\n<p></p>\n\n<ol>\n\t<li>Contractor shall enhance the FX-4000N platform by incorporating dual temperature trigger points through the completion of the following phases:</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Requirement Specification &amp; Feasibility Study\n\t\t<ol>\n\t\t\t<li>Define firmware and configurator change requirements.</li>\n\t\t\t<li>Conduct an exploratory study and initial testing on 5251 System sensor heat sensors.</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Firmware &amp; Configurator Development\n\t\t<ol>\n\t\t\t<li>Develop and implement necessary changes in firmware and the configurator.</li>\n\t\t\t<li>Conduct QA testing to ensure accurate reporting and compliance with specifications.</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>Contractor shall modify the MGC-4000 lockout configuration through the completion of the following phases:</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Upgrade the MGC-4000 configuration locking mechanism for US Navy panel.</li>\n\t\t<li>Update firmware and configurator accordingly.</li>\n\t\t<li>Perform Internal QA testing for validation of locking mechanism.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p><strong>CDRLS</strong></p>\n\n<p></p>\n\n<p>Status Report: (CDRL A001)<strong> - </strong>Contractor shall provide status reports as needed.</p>\n\n<p></p>\n\n<p></p>\n\n<p>SUBMISSION OF RESPONSES: Responses shall include specific details regarding the ability to provide the required items to meet the needs of the Government. Responses shall discuss how your product/service will meet the requirements.&nbsp;</p>\n\n<p></p>\n\n<p>Responses are not to exceed two (2) pages. Responses shall be in electronic format.&nbsp; A cover page for the response shall be included. The cover page shall include the company name, address, CAGE Code, Business Size Status for the North American Industry Classification System (NAICS) code of this RFI and points of contract (names, email, and telephone numbers) at a minimum.&nbsp; The cover page is not considered in the total page count.</p>\n\n<p></p>\n\n<p>NSWCPD will accept only electronic unclassified submission of responses. Responses shall be sent to Stefan Kitzinger at stefan.b.kitzinger.civ@us.navy.mil with the subject line &quot;RFI N6449825P510122.&quot; All responses shall be unclassified and submitted no later than 03:00 PM EST on 12 April 2025.</p>\n\n<p></p>\n\n<p>This RFI is for market research purposes only and does NOT constitute a Request for Proposal (RFP).&nbsp; This notice shall not be construed as a contract, a promise to contract, or as a commitment of any kind by the Government.&nbsp; The Government is NOT seeking or accepting unsolicited proposals.&nbsp; This RFI Notice is issued solely for conducting market research in accordance with FAR Part 10 and gathering information for planning purposes.</p>\n\n<p></p>\n\n<p>The Government WILL NOT PAY for any information received in response to this RFI, and the Government will not compensate the respondent for any cost incurred in developing the response to this RFI. The Government will not release any information marked with a proprietary legend received in response to this RFI to any firms, agencies or individuals outside the Government without written permission in accordance with the legend. Please be advised that all submissions become Government property and will not be returned. PHONE CALLS WILL NOT BE ACCEPTED.</p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Stefan Kitzinger","role":"primary","email":"stefan.b.kitzinger.civ@us.navy.mil"}],"place_of_performance":{"city":{"code":"60000","name":"Philadelphia"},"state":{"code":"PA","name":"Pennsylvania"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"19112-1403","city":"PHILADELPHIA","state":"PA","country":"USA"},"naics_codes":["541511"],"award":null,"attachments":[{"resource_id":"4c42828b021e4a5d853506d96fd810bb","name":"RFI N6449825P510122.docx","kind":"file","mime_type":".docx","size_bytes":79667,"posted_at":"2025-03-28T14:58:15.775Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4c42828b021e4a5d853506d96fd810bb/download","mirrored":false}],"awards":[],"related":[{"key":"N6449827SIMACQPD600004","latest_notice_id":"fcc91441ccb349d0ae83f9af13f18275","title":"Portable Vibration Monitoring System","solicitation_number":"N64498-27-SIMACQ-PD-60-0004","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"334515","psc":"6625","set_aside":null,"state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N6449827Q0009","latest_notice_id":"9167089ff2304258ac4a9daebeceb25c","title":"Shipping Tarps","solicitation_number":"N6449827Q0009","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-25","notices":2,"due_at":"2026-12-02T08:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T08:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"314999","psc":"8340","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8340)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"N6449826Q0054","latest_notice_id":"0c2cbcf93dfc432aab7790af1f47ed6f","title":"**Big Blue 3 MAC** Metal printer alterations will be completed onboard USS IWA JIMA (LHD 7), USS BOXER (LHD 4), LHD 8 (USS MAKIN ISLAND)","solicitation_number":"N6449826Q0054","notice_type":"o","first_type":"o","first_posted":"2026-09-30","last_posted":"2026-11-16","notices":6,"due_at":"2026-12-02T18:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"336611","psc":"R425","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"N6449827Q0005","latest_notice_id":"759706ecaed549b1990a980bca2c9801","title":"Big Blue MAC MACHALT FY27-FY28 MA668/MA688/MA738/MA739","solicitation_number":"N6449827Q0005","notice_type":"o","first_type":"o","first_posted":"2026-10-22","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"336611","psc":"R425","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N6449826R0547","latest_notice_id":"a4b0b949fd3c4f8fbc9c1cebcd1c5b2b","title":"**SOLE SOURCE RFP to Bird-Johnson Propeller Company** Navy Propulsor and Propellers","solicitation_number":"N6449826R0547","notice_type":"o","first_type":"o","first_posted":"2026-09-14","last_posted":"2026-11-02","notices":3,"due_at":"2026-12-03T18:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N64498","office_name":"NSWC PHILADELPHIA DIV","naics":"333618","psc":"J030","set_aside":null,"state":"MA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"110 NORFOLK STREETWALPOLE, MA 02081","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-03T04:52:39.433634Z"}],"similar_open":[{"key":"FA830727RB009","latest_notice_id":"cb3d70cb9e514d10b7e487b36f3430fe","title":"Notice of Proposed Contract Action/Notice of Intent to Sole Source Platform One Party Bus Bridge 2","solicitation_number":"FA830727RB009","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-29T15:00:00Z","due_date":"2026-11-29","closes_at":"2026-11-29T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8307","office_name":"FA8307 AFLCMC HNCK HNC CYBER & NTR","naics":"541511","psc":"DA01","set_aside":null,"state":"TX","county":"48029","county_name":"Bexar County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"F3G1EB6257AG01","latest_notice_id":"7303861ff65e47f9bf4c5aa6fb472f0a","title":"30 RS Mission Planning Software Tool (MPST)","solicitation_number":"F3G1EB6257AG01","notice_type":"k","first_type":"k","first_posted":"2026-11-06","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4861","office_name":"FA4861 99 CONS LGC","naics":"541511","psc":"DA10","set_aside":"SBA","state":"NV","county":"32003","county_name":"Clark County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"HT942727SSN702","latest_notice_id":"358f37ac0fb244f1a72af3e7e9477e44","title":"Automated Cost Estimating Integrated Tools (ACEIT)","solicitation_number":"HT9427-27-SSN-702","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9427","office_name":"DEFENSE HEALTH AGENCY","naics":"541511","psc":null,"set_aside":null,"state":"MD","county":"24021","county_name":"Frederick County","city":"2430325","city_name":"Frederick","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":14,"indexable":false}