{"canonical":"https://sealedbidder.com/opportunities/n6247325rj503","key":"N6247325RJ503","url":"https://sealedbidder.com/opportunities/n6247325rj503","title":"Bldg. 175 Replace Fuel Underground Storage Tank, NAS Lemoore, CA","solicitation_number":"N62473-25-R-J514","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":null,"first_posted":"2025-03-10","last_posted":"2026-02-03","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NAVFACSYSCOM SOUTHWEST","naics":"236220","psc":"Z2GC","set_aside":"SBA","place_state":"CA","place_scope":"site","site":"Naval Air Station Lemoore","place_state_source":null,"place_evidence":null,"place_county":"06031","place_county_name":"Kings County","place_city":"0641152","place_city_name":"Lemoore","winner":"WU & ASSOCIATES INC","award_amount":"2640000.00","publications":[{"notice_id":"35bbef245f9a43deb32db28f45582a32","title":"Replace Warehouse Lighting, Bldg. 140, NAS Lemoore, CA","solicitation_number":"N62473-25-R-J503","notice_type":"a","base_type":"a","posted":"2025-03-10","posted_at":"2025-03-10T23:50:36.127Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-03-21","removed_at":null,"award_number":"N62473-20-D-1103","awardee_name":"WU & ASSOCIATES INC","amount":"719000.00","link_sam":"https://sam.gov/workspace/contract/opp/35bbef245f9a43deb32db28f45582a32/view","enriched":true,"history":[{"index":3,"title":"Replace Warehouse Lighting, Bldg. 140, NAS Lemoore, CA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-10T23:50:36.127Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"35bbef245f9a43deb32db28f45582a32","solicitation_number":"N62473-25-R-J503"}]},{"notice_id":"798ccd8a16544627b2ed796aae8216ac","title":"Bldg. 175 Replace Fuel Underground Storage Tank, NAS Lemoore, CA","solicitation_number":"N62473-25-R-J514","notice_type":"a","base_type":"a","posted":"2026-02-03","posted_at":"2026-02-03T05:20:17.944Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-02-16","removed_at":null,"award_number":"N62473-20-D-1103","awardee_name":"WU & ASSOCIATES INC","amount":"2640000.00","link_sam":"https://sam.gov/workspace/contract/opp/798ccd8a16544627b2ed796aae8216ac/view","enriched":true,"history":[{"index":3,"title":"Bldg. 175 Replace Fuel Underground Storage Tank, NAS Lemoore, CA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-03T05:20:17.944Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"798ccd8a16544627b2ed796aae8216ac","solicitation_number":"N62473-25-R-J514"}]}],"latest_notice_id":"798ccd8a16544627b2ed796aae8216ac","first_type":"a","notices":[{"award":{"date":"2025-03-06","amount":"719000.00","number":"N62473-20-D-1103","awardee":{"raw":"WU & ASSOCIATES INC Mount Laurel NJ 08054 USA","uei":"MLSMLM5BFMW5","cage":"0P2R2","name":"WU & ASSOCIATES INC","location":{"zip":"08054","city":{"code":"49020","name":"Mount Laurel"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}},"delivery_order_number":"N62473-25-F-4302"},"dates":{"posted":"2025-03-10","posted_at":"2025-03-10T23:50:36.127Z","award_date":"2025-03-06","created_at":"2025-03-10T23:33:00.070Z","modified_at":"2025-03-22T03:55:45.478Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/35bbef245f9a43deb32db28f45582a32/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Replace Warehouse Lighting, Bldg. 140, NAS Lemoore, CA","agency":{"office":{"code":"N62473","name":"NAVFACSYSCOM SOUTHWEST"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"92132-0001","city":"SAN DIEGO","state":"CA","country":"USA"},"organization_id":"500045870","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-21","archive_type":"auto15"},"history":[{"index":3,"title":"Replace Warehouse Lighting, Bldg. 140, NAS Lemoore, CA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-10T23:50:36.127Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"35bbef245f9a43deb32db28f45582a32","solicitation_number":"N62473-25-R-J503"}],"contacts":[{"name":"Nathalie Zielinski","role":"primary","email":"nathalie.m.zielinski.civ@us.navy.mil","phone":"5599983892"},{"name":"Antonio Harley","role":"secondary","email":"antonio.b.harley2.civ@us.navy.mil","phone":"5599982086"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"35bbef245f9a43deb32db28f45582a32","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"35bbef245f9a43deb32db28f45582a32","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T00:43:53.516830341Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4cc1c5a4064e453aafde00c20121b2b4c1ed07887ac866fc1ea8fa330d6212b7","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T00:43:53.516830341Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>1.3 WORK COVERED BY CONTRACT DOCUMENTS</p>\n\n<p>1.3.1 Project Description The work includes retrofit existing lighting with new LED Lighting at all of the 5 priority areas in the warehouse building 140. The following is the description of the work at these 5 priority areas:</p>\n\n<p>1. Remove and dispose approximately (700) lights fixtures, in priority areas 1-5 with a combination of low bay and high bay lights.</p>\n\n<p>2. Furnish and install structure to move the location of the existing lights fixtures to the center of the rows and aisle ways.</p>\n\n<p>3. Use existing structures in priority areas 1-5 to mount the new light fixtures according to the Contract Drawings</p>\n\n<p>4 Use existing conduit and wire, and circuits feeding existing light fixtures to feed the new light fixtures.</p>\n\n<p>5 Furnish and install approximately (360)Light Emitting Diode(LED)with Circular Pie-Shaped(UFO) high bay lights, all with motion sensors. Provide an additional 5% light fixtures to the proposal ((16) LED UFO high bays).</p>\n\n<p>6 New Lights to be mounted above parts rows, and aisle ways.</p>\n\n<p>7 Remove and cap off light switches controlling existing lights.</p>\n\n<p>8 Dispose of approximately 1980 fluorescent lamps as hazardous.</p>\n\n<p>9 All new UFO LED lighting must be controlled by occupant sensors.</p>\n\n<p>10 Coordinate with facilities management service (FMS) for warehouse sensor zone setting.</p>\n\n<p>1.3.2 Location The work is located at Naval Air Station Lemoore building 140 (NASL), approximately as indicated on the Contract drawings (if provided). The exact location will be shown by the Construction Manager (CM).</p>\n\n<p>1.6 PROJECT DURATION 240 days after award</p>\n\n<p>1.7 LIQUIDATED DAMAGES $425 per Day</p>","text":"1.3 WORK COVERED BY CONTRACT DOCUMENTS\n\n1.3.1 Project Description The work includes retrofit existing lighting with new LED Lighting at all of the 5 priority areas in the warehouse building 140. The following is the description of the work at these 5 priority areas:\n\n1. Remove and dispose approximately (700) lights fixtures, in priority areas 1-5 with a combination of low bay and high bay lights.\n\n2. Furnish and install structure to move the location of the existing lights fixtures to the center of the rows and aisle ways.\n\n3. Use existing structures in priority areas 1-5 to mount the new light fixtures according to the Contract Drawings\n\n4 Use existing conduit and wire, and circuits feeding existing light fixtures to feed the new light fixtures.\n\n5 Furnish and install approximately (360)Light Emitting Diode(LED)with Circular Pie-Shaped(UFO) high bay lights, all with motion sensors. Provide an additional 5% light fixtures to the proposal ((16) LED UFO high bays).\n\n6 New Lights to be mounted above parts rows, and aisle ways.\n\n7 Remove and cap off light switches controlling existing lights.\n\n8 Dispose of approximately 1980 fluorescent lamps as hazardous.\n\n9 All new UFO LED lighting must be controlled by occupant sensors.\n\n10 Coordinate with facilities management service (FMS) for warehouse sensor zone setting.\n\n1.3.2 Location The work is located at Naval Air Station Lemoore building 140 (NASL), approximately as indicated on the Contract drawings (if provided). The exact location will be shown by the Construction Manager (CM).\n\n1.6 PROJECT DURATION 240 days after award\n\n1.7 LIQUIDATED DAMAGES $425 per Day","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"N62473-25-R-J503","place_of_performance":{"zip":"93246","city":{"code":"41152","name":"Lemoore"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2GZ"},{"award":{"date":"2025-12-09","amount":"2640000.00","number":"N62473-20-D-1103","awardee":{"raw":"WU & ASSOCIATES INC Mount Laurel NJ 08054 USA","uei":"MLSMLM5BFMW5","cage":"0P2R2","name":"WU & ASSOCIATES INC","location":{"zip":"08054","city":{"code":"49020","name":"Mount Laurel"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}},"delivery_order_number":"N62473-26-F-0039"},"dates":{"posted":"2026-02-03","posted_at":"2026-02-03T05:20:17.944Z","award_date":"2025-12-09","created_at":"2026-02-03T05:00:18.090Z","modified_at":"2026-02-17T04:55:44.525Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/798ccd8a16544627b2ed796aae8216ac/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Bldg. 175 Replace Fuel Underground Storage Tank, NAS Lemoore, CA","agency":{"office":{"code":"N62473","name":"NAVFACSYSCOM SOUTHWEST"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"92132-0001","city":"SAN DIEGO","state":"CA","country":"USA"},"organization_id":"500045870","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"Bldg. 175 Replace Fuel Underground Storage Tank, NAS Lemoore, CA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-03T05:20:17.944Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"798ccd8a16544627b2ed796aae8216ac","solicitation_number":"N62473-25-R-J514"}],"contacts":[{"name":"Nathalie Zielinski","role":"primary","email":"nathalie.m.zielinski.civ@us.navy.mil","phone":"5599983892"},{"name":"Antonio B. Harley","role":"secondary","email":"Antonio.b.harley1@navy.mil","phone":"5599982086"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"798ccd8a16544627b2ed796aae8216ac","lineage_id":"798ccd8a16544627b2ed796aae8216ac","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T03:51:28.430408296Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"bab6793820a6c8dfe83793e242089ba7545f22b7e9427b7de450e5a80f2a093b","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T03:51:28.430408296Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The intent of this project is to replace the underground jet fuel storage<br />\ntank at the B-175 Jet Engine Test Cell with a new, double-wall,<br />\naboveground storage tank. Specific methods shall be as described below.</p>\n\n<p><br />\nWork Requirements:</p>\n\n<p><br />\na. Construction:<br />\n1. Install new concrete pad, tank footings, and containment curb in<br />\naccordance with the drawing requirements including piping and conduit<br />\npenetrations.<br />\n2. Install a new 20,000 gallon factory fabricated, double wall, protected,<br />\nabove-ground jet fuel storage tank including platform and stairway as<br />\nindicated on the drawing.<br />\n3. Install new concrete fuel pipe trench with traffic rated grating as<br />\nindicated on the drawing.<br />\n4. Install new electrical pull boxes, concrete ductbank, and conduits as indicated on the drawing.<br />\n5. Install new two new fuel pumps in accordance with the pump schedule.<br />\n6. Relocate indicated devices and piping including new cathodic protection<br />\nfor underground piping.<br />\n7. Relocate existing emergency stop panel as indicated and add a new<br />\nreadout for the automatic tank gauge system.<br />\n8. Install new stainless steel piping and valves as indicated to<br />\nre-establish all connections with the new above-ground tank.<br />\n9. Install bollards all the way around the new tank and pad area as<br />\nindicated on the drawing.<br />\n10. Install new light post where indicated on the drawing, including switch<br />\nnear the stairwell.<br />\n11. Install new fire hydrant where indicated on the drawing.<br />\n12. Install a new eyewash station as indicated.<br />\n13. Perform all requisite equipment testing and verifications in<br />\naccordance with specification requirements.</p>\n\n<p><br />\nb. Demolition:<br />\n1. Demolish and remove all concrete as indicated above the underground<br />\ntank to provide access for excavation of the tank.<br />\n2. Remove existing devices and piping to be relocated as indicated on the<br />\ndrawing.<br />\n3. Remove existing emergency stop panel and associated conduit to be<br />\nrelocated as indicated on the drawing.<br />\n4. Remove existing cathodic protection test wells and associated cabling<br />\nand anodes where indicated.<br />\n5. Remove existing fiberglass transition sump and concrete collar as<br />\nindicated.<br />\n6. Remove the existing fuel pumps, associated devices, and electrical<br />\nboxes and conduits as indicated.<br />\n7. Excavate and completely remove the 20,000 gallon underground jet fuel<br />\nstorage tank. This tank removal must be completed (out of the ground) by<br />\nDecember 31st 2025. Liquidated damages may be assessed as detailed in<br />\nSection 1.7 for this activity.<br />\n8. Remove the concrete base beneath the existing underground tank.<br />\n9. Perform all requisite clean-up and testing associated with the removal<br />\nin accordance with all of the federal, state, and local environmental<br />\nrequirements.<br />\n10. Remove existing fire hydrant and associated piping as indicated.<br />\n10. Remove existing valve, valve box, pedestal type hose bib, and<br />\nassociated piping as indicated.<br />\n11. Remove existing bollards where indicated.<br />\n12. Remove existing concrete ductbank and conduits back to the building as<br />\nindicated.<br />\n13. Remove existing double wall fuel supply and return pipes back to the<br />\nbuilding as indicated.</p>","text":"The intent of this project is to replace the underground jet fuel storage\n\ntank at the B-175 Jet Engine Test Cell with a new, double-wall,\n\naboveground storage tank. Specific methods shall be as described below.\n\nWork Requirements:\n\na. Construction:\n\n1. Install new concrete pad, tank footings, and containment curb in\n\naccordance with the drawing requirements including piping and conduit\n\npenetrations.\n\n2. Install a new 20,000 gallon factory fabricated, double wall, protected,\n\nabove-ground jet fuel storage tank including platform and stairway as\n\nindicated on the drawing.\n\n3. Install new concrete fuel pipe trench with traffic rated grating as\n\nindicated on the drawing.\n\n4. Install new electrical pull boxes, concrete ductbank, and conduits as indicated on the drawing.\n\n5. Install new two new fuel pumps in accordance with the pump schedule.\n\n6. Relocate indicated devices and piping including new cathodic protection\n\nfor underground piping.\n\n7. Relocate existing emergency stop panel as indicated and add a new\n\nreadout for the automatic tank gauge system.\n\n8. Install new stainless steel piping and valves as indicated to\n\nre-establish all connections with the new above-ground tank.\n\n9. Install bollards all the way around the new tank and pad area as\n\nindicated on the drawing.\n\n10. Install new light post where indicated on the drawing, including switch\n\nnear the stairwell.\n\n11. Install new fire hydrant where indicated on the drawing.\n\n12. Install a new eyewash station as indicated.\n\n13. Perform all requisite equipment testing and verifications in\n\naccordance with specification requirements.\n\nb. Demolition:\n\n1. Demolish and remove all concrete as indicated above the underground\n\ntank to provide access for excavation of the tank.\n\n2. Remove existing devices and piping to be relocated as indicated on the\n\ndrawing.\n\n3. Remove existing emergency stop panel and associated conduit to be\n\nrelocated as indicated on the drawing.\n\n4. Remove existing cathodic protection test wells and associated cabling\n\nand anodes where indicated.\n\n5. Remove existing fiberglass transition sump and concrete collar as\n\nindicated.\n\n6. Remove the existing fuel pumps, associated devices, and electrical\n\nboxes and conduits as indicated.\n\n7. Excavate and completely remove the 20,000 gallon underground jet fuel\n\nstorage tank. This tank removal must be completed (out of the ground) by\n\nDecember 31st 2025. Liquidated damages may be assessed as detailed in\n\nSection 1.7 for this activity.\n\n8. Remove the concrete base beneath the existing underground tank.\n\n9. Perform all requisite clean-up and testing associated with the removal\n\nin accordance with all of the federal, state, and local environmental\n\nrequirements.\n\n10. Remove existing fire hydrant and associated piping as indicated.\n\n10. Remove existing valve, valve box, pedestal type hose bib, and\n\nassociated piping as indicated.\n\n11. Remove existing bollards where indicated.\n\n12. Remove existing concrete ductbank and conduits back to the building as\n\nindicated.\n\n13. Remove existing double wall fuel supply and return pipes back to the\n\nbuilding as indicated.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"N62473-25-R-J514","place_of_performance":{"zip":"93246","city":{"code":"41152","name":"Lemoore"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2GC"}],"due_at":null,"due_date":null,"closes_at":null,"awardable":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62473","office_name":"NAVFACSYSCOM SOUTHWEST","state":"CA","county":"06031","county_name":"Kings County","city":"0641152","city_name":"Lemoore","country":"USA","state_source":null,"state_evidence":null,"site_key":"naval-air-station-lemoore-ca","winner_key":"MLSMLM5BFMW5","amount":"2640000.00","linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-14T03:57:08.970241Z","principal_notice_id":"798ccd8a16544627b2ed796aae8216ac","description":{"text":"The intent of this project is to replace the underground jet fuel storage\n\ntank at the B-175 Jet Engine Test Cell with a new, double-wall,\n\naboveground storage tank. Specific methods shall be as described below.\n\nWork Requirements:\n\na. Construction:\n\n1. Install new concrete pad, tank footings, and containment curb in\n\naccordance with the drawing requirements including piping and conduit\n\npenetrations.\n\n2. Install a new 20,000 gallon factory fabricated, double wall, protected,\n\nabove-ground jet fuel storage tank including platform and stairway as\n\nindicated on the drawing.\n\n3. Install new concrete fuel pipe trench with traffic rated grating as\n\nindicated on the drawing.\n\n4. Install new electrical pull boxes, concrete ductbank, and conduits as indicated on the drawing.\n\n5. Install new two new fuel pumps in accordance with the pump schedule.\n\n6. Relocate indicated devices and piping including new cathodic protection\n\nfor underground piping.\n\n7. Relocate existing emergency stop panel as indicated and add a new\n\nreadout for the automatic tank gauge system.\n\n8. Install new stainless steel piping and valves as indicated to\n\nre-establish all connections with the new above-ground tank.\n\n9. Install bollards all the way around the new tank and pad area as\n\nindicated on the drawing.\n\n10. Install new light post where indicated on the drawing, including switch\n\nnear the stairwell.\n\n11. Install new fire hydrant where indicated on the drawing.\n\n12. Install a new eyewash station as indicated.\n\n13. Perform all requisite equipment testing and verifications in\n\naccordance with specification requirements.\n\nb. Demolition:\n\n1. Demolish and remove all concrete as indicated above the underground\n\ntank to provide access for excavation of the tank.\n\n2. Remove existing devices and piping to be relocated as indicated on the\n\ndrawing.\n\n3. Remove existing emergency stop panel and associated conduit to be\n\nrelocated as indicated on the drawing.\n\n4. Remove existing cathodic protection test wells and associated cabling\n\nand anodes where indicated.\n\n5. Remove existing fiberglass transition sump and concrete collar as\n\nindicated.\n\n6. Remove the existing fuel pumps, associated devices, and electrical\n\nboxes and conduits as indicated.\n\n7. Excavate and completely remove the 20,000 gallon underground jet fuel\n\nstorage tank. This tank removal must be completed (out of the ground) by\n\nDecember 31st 2025. Liquidated damages may be assessed as detailed in\n\nSection 1.7 for this activity.\n\n8. Remove the concrete base beneath the existing underground tank.\n\n9. Perform all requisite clean-up and testing associated with the removal\n\nin accordance with all of the federal, state, and local environmental\n\nrequirements.\n\n10. Remove existing fire hydrant and associated piping as indicated.\n\n10. Remove existing valve, valve box, pedestal type hose bib, and\n\nassociated piping as indicated.\n\n11. Remove existing bollards where indicated.\n\n12. Remove existing concrete ductbank and conduits back to the building as\n\nindicated.\n\n13. Remove existing double wall fuel supply and return pipes back to the\n\nbuilding as indicated.","html":"<p>The intent of this project is to replace the underground jet fuel storage<br />\ntank at the B-175 Jet Engine Test Cell with a new, double-wall,<br />\naboveground storage tank. Specific methods shall be as described below.</p>\n\n<p><br />\nWork Requirements:</p>\n\n<p><br />\na. Construction:<br />\n1. Install new concrete pad, tank footings, and containment curb in<br />\naccordance with the drawing requirements including piping and conduit<br />\npenetrations.<br />\n2. Install a new 20,000 gallon factory fabricated, double wall, protected,<br />\nabove-ground jet fuel storage tank including platform and stairway as<br />\nindicated on the drawing.<br />\n3. Install new concrete fuel pipe trench with traffic rated grating as<br />\nindicated on the drawing.<br />\n4. Install new electrical pull boxes, concrete ductbank, and conduits as indicated on the drawing.<br />\n5. Install new two new fuel pumps in accordance with the pump schedule.<br />\n6. Relocate indicated devices and piping including new cathodic protection<br />\nfor underground piping.<br />\n7. Relocate existing emergency stop panel as indicated and add a new<br />\nreadout for the automatic tank gauge system.<br />\n8. Install new stainless steel piping and valves as indicated to<br />\nre-establish all connections with the new above-ground tank.<br />\n9. Install bollards all the way around the new tank and pad area as<br />\nindicated on the drawing.<br />\n10. Install new light post where indicated on the drawing, including switch<br />\nnear the stairwell.<br />\n11. Install new fire hydrant where indicated on the drawing.<br />\n12. Install a new eyewash station as indicated.<br />\n13. Perform all requisite equipment testing and verifications in<br />\naccordance with specification requirements.</p>\n\n<p><br />\nb. Demolition:<br />\n1. Demolish and remove all concrete as indicated above the underground<br />\ntank to provide access for excavation of the tank.<br />\n2. Remove existing devices and piping to be relocated as indicated on the<br />\ndrawing.<br />\n3. Remove existing emergency stop panel and associated conduit to be<br />\nrelocated as indicated on the drawing.<br />\n4. Remove existing cathodic protection test wells and associated cabling<br />\nand anodes where indicated.<br />\n5. Remove existing fiberglass transition sump and concrete collar as<br />\nindicated.<br />\n6. Remove the existing fuel pumps, associated devices, and electrical<br />\nboxes and conduits as indicated.<br />\n7. Excavate and completely remove the 20,000 gallon underground jet fuel<br />\nstorage tank. This tank removal must be completed (out of the ground) by<br />\nDecember 31st 2025. Liquidated damages may be assessed as detailed in<br />\nSection 1.7 for this activity.<br />\n8. Remove the concrete base beneath the existing underground tank.<br />\n9. Perform all requisite clean-up and testing associated with the removal<br />\nin accordance with all of the federal, state, and local environmental<br />\nrequirements.<br />\n10. Remove existing fire hydrant and associated piping as indicated.<br />\n10. Remove existing valve, valve box, pedestal type hose bib, and<br />\nassociated piping as indicated.<br />\n11. Remove existing bollards where indicated.<br />\n12. Remove existing concrete ductbank and conduits back to the building as<br />\nindicated.<br />\n13. Remove existing double wall fuel supply and return pipes back to the<br />\nbuilding as indicated.</p>","origin":"detail"},"contacts":[{"name":"Nathalie Zielinski","role":"primary","email":"nathalie.m.zielinski.civ@us.navy.mil","phone":"5599983892"},{"name":"Antonio B. Harley","role":"secondary","email":"Antonio.b.harley1@navy.mil","phone":"5599982086"}],"place_of_performance":{"zip":"93246","city":{"code":"41152","name":"Lemoore"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"92132-0001","city":"SAN DIEGO","state":"CA","country":"USA"},"naics_codes":["236220"],"award":{"date":"2025-12-09","amount":"2640000.00","number":"N62473-20-D-1103","awardee":{"raw":"WU & ASSOCIATES INC Mount Laurel NJ 08054 USA","uei":"MLSMLM5BFMW5","cage":"0P2R2","name":"WU & ASSOCIATES INC","location":{"zip":"08054","city":{"code":"49020","name":"Mount Laurel"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}},"delivery_order_number":"N62473-26-F-0039"},"attachments":[],"awards":[{"award_key":"CONT_IDV_N6247320D1103_9700","permalink":"https://www.usaspending.gov/award/CONT_IDV_N6247320D1103_9700/","piid":"N6247320D1103","parent_piid":null,"award_type":null,"vendor_key":"MLSMLM5BFMW5","recipient_name":"WU & ASSOCIATES INC","recipient_uei":"MLSMLM5BFMW5","recipient_cage":"0P2R2","recipient_city":"MOUNT LAUREL","recipient_state":"NJ","sub_name":"Department of the Navy","office_name":"NAVFACSYSCOM SOUTHWEST","office_key":"o-N62473","first_action_date":"2024-04-24","last_action_date":"2026-04-14","actions":4,"obligated":"0","current_total_value":null,"potential_total_value":"99999000.00","naics":"236220","psc":"Y1AZ","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":36,"description":"ADD FAR CLAUSE 52.204- 30","method":"piid","confidence":"high","evidence":["award number N6247320D1103 equals the contract number","same awarding office N62473"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"N6247327RP00038","latest_notice_id":"7c27e49dea7a4a7780a1de2e448d545b","title":"Request for Proposals (RFP) Eight (8) Fully Furnished Apartment Units for Navy Trauma Training Center (NTTC) Students, Los Angeles, CA","solicitation_number":"N6247327RP00038","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-03T00:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62473","office_name":"NAVFACSYSCOM SOUTHWEST","naics":"531110","psc":"X1FZ","set_aside":null,"state":"CA","county":"06037","county_name":"Los Angeles County","city":"0644000","city_name":"Los Angeles","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N6247327R0006","latest_notice_id":"1484bb1bdb784f7c965ddab80dcfcf54","title":"N6247327R0006 Project Labor Agreement Request for Information","solicitation_number":"N6247327R0006","notice_type":"p","first_type":"r","first_posted":"2026-09-15","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-03T22:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62473","office_name":"NAVFACSYSCOM SOUTHWEST","naics":"237130","psc":"Y1MZ","set_aside":null,"state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"N6247326R9953","latest_notice_id":"081809a883964dffaf485090be4a155a","title":"Base Operations Support Contract (BOSC) for Naval Air Weapons Station (NAWS) China Lake, California and Other Locations as Approved","solicitation_number":"N6247326R9953","notice_type":"o","first_type":"o","first_posted":"2026-06-01","last_posted":"2026-11-24","notices":11,"due_at":"2026-12-08T22:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62473","office_name":"NAVFACSYSCOM SOUTHWEST","naics":"561210","psc":"S216","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"title","state_evidence":"NAVAL AIR WEAPONS STATION (NAWS) CHINA LAKE, CALIFORNIA","site":"China Lake","site_key":"china-lake-ca","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N6247325R0004","latest_notice_id":"7aee513b670c4568b172f27fee5ed789","title":"IDIQ SMALL BUSINESS SET-ASIDE MACC FOR PAVING PROJECTS AT VARIOUS GOVERNMENT INSTALLATIONS LOCATED IN CA, AZ, NV, UT, CO, AND NM","solicitation_number":"N6247325R0004","notice_type":"o","first_type":"r","first_posted":"2025-03-20","last_posted":"2026-11-25","notices":3,"due_at":"2026-12-08T22:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62473","office_name":"NAVFACSYSCOM SOUTHWEST","naics":"237310","psc":"Z1LB","set_aside":"SBA","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"N6247327R0014","latest_notice_id":"9e36b34d0e1d48d494fcd19d70cdcbcf","title":"IDIQ JOC 8(a) SMALL BUSINESS SET-ASIDE UNDER NAICS 238210 FOR ELECTRICAL CONTRACTORS AND OTHER WIRING INSTALLATION CONTRACTORS AT VARIOUS GOVERNMENT FACILITIES LOCATED WITHIN THE MCAGCC 29 PALMS AOR","solicitation_number":"N6247327R0014","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62473","office_name":"NAVFACSYSCOM SOUTHWEST","naics":"238210","psc":"Z2AZ","set_aside":null,"state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"MARINE CORPS AIR GROUND COMBAT CENTER TWENTYNINE PALMS, CALIFORNIA 92278","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open":[{"key":"FA890327OT005","latest_notice_id":"b720e0fdba4b4ab88d9891c5a117348f","title":"MACH1_AOI_Military Working Dog Facility_ Vandenberg Space Force_LOE 1 and LOE 2","solicitation_number":"FA8903-27-OT005","notice_type":"p","first_type":"p","first_posted":"2026-10-20","last_posted":"2026-11-13","notices":3,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8903","office_name":"FA8903 772 ESS PK","naics":"236220","psc":"Y1JZ","set_aside":null,"state":"CA","county":"06083","county_name":"Santa Barbara County","city":"0642524","city_name":"Lompoc","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26127Q0029","latest_notice_id":"2c624d0668744bc89d37e48ea7fb7fd4","title":"Amendment 0002 Y1DZ--36C261-28-AP-0022 | 612-27-1-6009-0001 | Construct Modular Imaging Center in Stockton | 612A4-CSI-002","solicitation_number":"36C26127Q0029","notice_type":"o","first_type":"p","first_posted":"2026-08-26","last_posted":"2026-10-15","notices":4,"due_at":"2026-12-04T20:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"Y1DZ","set_aside":"SDVOSBC","state":"CA","county":"06077","county_name":"San Joaquin County","city":"0626028","city_name":"French Camp","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-16T03:38:05.572608Z"},{"key":"47PD5527Q0010","latest_notice_id":"c40dbc1f3f8d405bb1db80d80e4c50cb","title":"DHS HSI Schwartz 2nd Floor Carpet Replacement","solicitation_number":"47PD5527Q0010","notice_type":"k","first_type":"k","first_posted":"2026-10-22","last_posted":"2026-11-03","notices":2,"due_at":"2026-12-05T00:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-05T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-047","dept_name":"GENERAL SERVICES ADMINISTRATION","sub_key":"s-4740","sub_name":"PUBLIC BUILDINGS SERVICE","office_key":"o-47PD55","office_name":"PBS PROJECT DELIVERY WEST - BRANCH E","naics":"236220","psc":"Z2AA","set_aside":"SBA","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-20T06:16:47.576280Z"}],"similar_open_total":193,"indexable":false}