{"canonical":"https://sealedbidder.com/opportunities/n4523a50853036","key":"N4523A50853036","url":"https://sealedbidder.com/opportunities/n4523a50853036","title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","solicitation_number":"N4523A50853036","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-05-06T17:00:00Z","first_posted":"2025-04-22","last_posted":"2025-04-23","department":"DEPT OF DEFENSE","subagency":"DEFENSE LOGISTICS AGENCY","office":"DLA MARITIME - PUGET SOUND","naics":"334519","psc":"6350","set_aside":"SBA","place_state":"WA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"53035","place_county_name":"Kitsap County","place_city":"5307695","place_city_name":"Bremerton","winner":null,"award_amount":null,"publications":[{"notice_id":"6064a69d06dd48beafdae5fbeb8a392b","title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","solicitation_number":"N4523A50853036","notice_type":"r","base_type":"r","posted":"2025-04-22","posted_at":"2025-04-22T16:58:46.424Z","due_at":"2025-05-06T17:00:00Z","due_date":"2025-05-06","cancelled":false,"archived":true,"archive_date":"2025-05-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6064a69d06dd48beafdae5fbeb8a392b/view","enriched":true,"history":[{"index":4,"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-23T15:19:26.869Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7af6020534834ccbae8f1cb7a5743afa","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":2,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T17:03:42.871Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"8c9b1026a2e44f7495c9b414c22491fb","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":1,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T16:58:46.424Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b","solicitation_number":"N4523A50853036"}]},{"notice_id":"8c9b1026a2e44f7495c9b414c22491fb","title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","solicitation_number":"N4523A50853036","notice_type":"r","base_type":"r","posted":"2025-04-22","posted_at":"2025-04-22T17:03:42.871Z","due_at":"2025-05-06T17:00:00Z","due_date":"2025-05-06","cancelled":false,"archived":true,"archive_date":"2025-05-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8c9b1026a2e44f7495c9b414c22491fb/view","enriched":true,"history":[{"index":4,"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-23T15:19:26.869Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7af6020534834ccbae8f1cb7a5743afa","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":2,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T17:03:42.871Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"8c9b1026a2e44f7495c9b414c22491fb","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":1,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T16:58:46.424Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b","solicitation_number":"N4523A50853036"}]},{"notice_id":"7af6020534834ccbae8f1cb7a5743afa","title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","solicitation_number":"N4523A50853036","notice_type":"r","base_type":"r","posted":"2025-04-23","posted_at":"2025-04-23T15:19:26.869Z","due_at":"2025-05-06T17:00:00Z","due_date":"2025-05-06","cancelled":false,"archived":true,"archive_date":"2025-05-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7af6020534834ccbae8f1cb7a5743afa/view","enriched":true,"history":[{"index":4,"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-23T15:19:26.869Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7af6020534834ccbae8f1cb7a5743afa","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":2,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T17:03:42.871Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"8c9b1026a2e44f7495c9b414c22491fb","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":1,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T16:58:46.424Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b","solicitation_number":"N4523A50853036"}]}],"latest_notice_id":"7af6020534834ccbae8f1cb7a5743afa","first_type":"r","notices":[{"dates":{"posted":"2025-04-22","posted_at":"2025-04-22T16:58:46.424Z","created_at":"2025-04-22T16:51:17.992Z","modified_at":"2025-05-22T03:55:52.133Z","response_deadline":{"raw":"2025-05-06T10:00:00-07:00","utc":"2025-05-06T17:00:00Z","date":"2025-05-06","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6064a69d06dd48beafdae5fbeb8a392b/view"},"naics":{"codes":["334519"],"primary":"334519"},"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","agency":{"office":{"code":"SPMYM2","name":"DLA MARITIME - PUGET SOUND"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"98314-5000","city":"BREMERTON","state":"WA","country":"USA"},"organization_id":"500032826","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-21","archive_type":"auto15"},"history":[{"index":4,"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-23T15:19:26.869Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7af6020534834ccbae8f1cb7a5743afa","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":2,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T17:03:42.871Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"8c9b1026a2e44f7495c9b414c22491fb","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":1,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T16:58:46.424Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b","solicitation_number":"N4523A50853036"}],"contacts":[{"fax":"3604764121","name":"JACK EDWARDS","role":"primary","email":"JACK.EDWARDS@DLA.MIL","phone":"3608139577"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"6064a69d06dd48beafdae5fbeb8a392b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"6064a69d06dd48beafdae5fbeb8a392b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T03:12:32.997439641Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"5cdfdea308beef790ed84a8a388ff05fd72b245210f87a93c463044af17f321d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T03:12:32.997439641Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>SOURCES SOUGHT SYNOPSIS &nbsp;- PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</strong></p>\n\n<p>The Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.</p>\n\n<ol>\n\t<li>&nbsp;PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION &ndash; QTY 1</li>\n\t<li>MFG: GENERON</li>\n</ol>\n\n<p>SPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</p>\n\n<p>1. <u>SCOPE</u><u>:</u></p>\n\n<p>1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government</p>\n\n<p>for a &ldquo;Turnkey&rdquo; Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification</p>\n\n<p>provides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating</p>\n\n<p>System. This system should be designed to supply a continuous flow of nitrogen of a minimum of</p>\n\n<p>300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%</p>\n\n<p>(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.</p>\n\n<p>1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the</p>\n\n<p>Government&rsquo;s intent that a single (primary) contractor experienced in the production of membrane</p>\n\n<p>generating system technology in the marine industrial environment be awarded this contract and be</p>\n\n<p>responsible for the accomplishment of all work, including 3rd party certifications.</p>\n\n<p>2. <u>CONTAINER:</u></p>\n\n<p>2.1. The NPU shall be a stand-alone, &ldquo;Turnkey&rdquo; system. All components for the NPU should be installed</p>\n\n<p>within a max 8&rsquo; wide x 8&rsquo; high x 10&rsquo; long insulated, able to withstand when ambient temperatures drop to</p>\n\n<p>28&deg;F. ISO container, designed to permit relocation by crane, truck, and forklift.</p>\n\n<p>2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and</p>\n\n<p>should require only integration, assembly, operational verification and certification in final configuration</p>\n\n<p>to meet the contract specifications.</p>\n\n<p>2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative</p>\n\n<p>designs that improve system function, capacity, size, weight, or cost are encouraged to be included by the</p>\n\n<p>offeror in response.</p>\n\n<p>2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,</p>\n\n<p>snow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The</p>\n\n<p>operating environment is marine waterfront; therefore, components and coatings must be selected for</p>\n\n<p>protection from this corrosive environment.</p>\n\n<p>2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of</p>\n\n<p>300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and</p>\n\n<p>delivery of industrial grade Nitrogen. Operational performance design of the NPU should target the</p>\n\n<p>General Industrial usage.</p>\n\n<p>3. <u>SAMPLING REQUIREMENTS:</u></p>\n\n<p>3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally</p>\n\n<p>Recognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is</p>\n\n<p>properly marked with NRTL certification marking.</p>\n\n<p>4. <u>SET UP SERVICES AND TESTING</u>:</p>\n\n<p>4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and</p>\n\n<p>tested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall</p>\n\n<p>provide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen</p>\n\n<p>generator.</p>\n\n<p>4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.</p>\n\n<p>5. <u>TRAINING:</u></p>\n\n<p>5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of</p>\n\n<p>operation of the unit to include proper maintenance of the system. Customer will be charged at the current</p>\n\n<p>daily service rate, plus travel and living expenses.</p>\n\n<p>6. <u>NOISE:</u></p>\n\n<p>6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure</p>\n\n<p>ambient noise levels outside &lt;84db not to exceed &lt;103db and inside of the containerized unit &lt;104db not</p>\n\n<p>to exceed &lt;120db.</p>\n\n<p>7. <u>SOFTWARE:</u></p>\n\n<p>7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard</p>\n\n<p>factory set process control valve, Zirconium oxide oxygen analyzer.</p>\n\n<p>8. <u>REQUIREMENTS:</u></p>\n\n<p>8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After</p>\n\n<p>delivery, the unit shall require only the connection of power, routing of condensate, and testing in</p>\n\n<p>accordance with this specification.</p>\n\n<p>8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both</p>\n\n<p>in-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to</p>\n\n<p>certified standards that have known valid relationships to nationally accepted industry standards.</p>\n\n<p>8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of</p>\n\n<p>85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).</p>\n\n<p>8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be</p>\n\n<p>installed on the inlet piping.</p>\n\n<p>8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed</p>\n\n<p>through an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any</p>\n\n<p>Hydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built</p>\n\n<p>in .01 dust particulate wrap to ensure no carbon particulates enter the membranes.</p>\n\n<p>8.6. All electrical components to meet an area classification of Safe No Hazard.</p>\n\n<p>8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt</p>\n\n<p>supply, 480 Volt 3 Phase, 60 Hertz</p>\n\n<p>The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334515 &ndash; Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals</p>\n\n<p><strong><u>THERE IS NO SOLICITATION AT THIS TIME.&nbsp;</u></strong>This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.&nbsp;</p>\n\n<p>If your organization has the potential capacity to provide these items, please provide the following information:</p>\n\n<ol>\n\t<li>Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,</li>\n\t<li>Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.</li>\n</ol>\n\n<p>Responses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil</p>\n\n<p>If you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil</p>\n\n<p>Attachments/Links</p>\n\n<p>No attachments or links have been added to this opportunity.</p>\n\n<p>Contact Information</p>\n\n<p>Contracting Office Address</p>\n\n<ul>\n\t<li>CONTRACTING DIVISION (DLA-PME) 467 W STREET</li>\n\t<li>BREMERTON, WA 98314-5000</li>\n\t<li>USA</li>\n</ul>\n\n<p>Primary Point of Contact</p>\n\n<ul>\n\t<li><strong>JACK EDWARDS</strong></li>\n\t<li>JACK.EDWARDS@DLA.MIL</li>\n\t<li>Phone Number&nbsp;360-813-9577</li>\n</ul>\n\n<p></p>\n\n<p></p>","text":"SOURCES SOUGHT SYNOPSIS - PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\nThe Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.\n\n• PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION – QTY 1\n\n• MFG: GENERON\n\nSPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\n1. SCOPE:\n\n1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government\n\nfor a “Turnkey” Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification\n\nprovides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating\n\nSystem. This system should be designed to supply a continuous flow of nitrogen of a minimum of\n\n300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%\n\n(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.\n\n1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the\n\nGovernment’s intent that a single (primary) contractor experienced in the production of membrane\n\ngenerating system technology in the marine industrial environment be awarded this contract and be\n\nresponsible for the accomplishment of all work, including 3rd party certifications.\n\n2. CONTAINER:\n\n2.1. The NPU shall be a stand-alone, “Turnkey” system. All components for the NPU should be installed\n\nwithin a max 8’ wide x 8’ high x 10’ long insulated, able to withstand when ambient temperatures drop to\n\n28°F. ISO container, designed to permit relocation by crane, truck, and forklift.\n\n2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and\n\nshould require only integration, assembly, operational verification and certification in final configuration\n\nto meet the contract specifications.\n\n2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative\n\ndesigns that improve system function, capacity, size, weight, or cost are encouraged to be included by the\n\nofferor in response.\n\n2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,\n\nsnow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The\n\noperating environment is marine waterfront; therefore, components and coatings must be selected for\n\nprotection from this corrosive environment.\n\n2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of\n\n300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and\n\ndelivery of industrial grade Nitrogen. Operational performance design of the NPU should target the\n\nGeneral Industrial usage.\n\n3. SAMPLING REQUIREMENTS:\n\n3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally\n\nRecognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is\n\nproperly marked with NRTL certification marking.\n\n4. SET UP SERVICES AND TESTING:\n\n4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and\n\ntested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall\n\nprovide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen\n\ngenerator.\n\n4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.\n\n5. TRAINING:\n\n5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of\n\noperation of the unit to include proper maintenance of the system. Customer will be charged at the current\n\ndaily service rate, plus travel and living expenses.\n\n6. NOISE:\n\n6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure\n\nambient noise levels outside <84db not to exceed <103db and inside of the containerized unit <104db not\n\nto exceed <120db.\n\n7. SOFTWARE:\n\n7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard\n\nfactory set process control valve, Zirconium oxide oxygen analyzer.\n\n8. REQUIREMENTS:\n\n8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After\n\ndelivery, the unit shall require only the connection of power, routing of condensate, and testing in\n\naccordance with this specification.\n\n8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both\n\nin-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to\n\ncertified standards that have known valid relationships to nationally accepted industry standards.\n\n8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of\n\n85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).\n\n8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be\n\ninstalled on the inlet piping.\n\n8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed\n\nthrough an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any\n\nHydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built\n\nin .01 dust particulate wrap to ensure no carbon particulates enter the membranes.\n\n8.6. All electrical components to meet an area classification of Safe No Hazard.\n\n8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt\n\nsupply, 480 Volt 3 Phase, 60 Hertz\n\nThe results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334515 – Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals\n\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.\n\nIf your organization has the potential capacity to provide these items, please provide the following information:\n\n• Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,\n\n• Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.\n\nResponses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil\n\nIf you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil\n\nAttachments/Links\n\nNo attachments or links have been added to this opportunity.\n\nContact Information\n\nContracting Office Address\n\n• CONTRACTING DIVISION (DLA-PME) 467 W STREET\n\n• BREMERTON, WA 98314-5000\n\n• USA\n\nPrimary Point of Contact\n\n• JACK EDWARDS\n\n• JACK.EDWARDS@DLA.MIL\n\n• Phone Number 360-813-9577","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"N4523A50853036","place_of_performance":{"zip":"98314","city":{"code":"7695","name":"Bremerton"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6350"},{"dates":{"posted":"2025-04-22","posted_at":"2025-04-22T17:03:42.871Z","created_at":"2025-04-22T17:02:04.222Z","modified_at":"2025-05-22T03:55:52.133Z","response_deadline":{"raw":"2025-05-06T10:00:00-07:00","utc":"2025-05-06T17:00:00Z","date":"2025-05-06","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8c9b1026a2e44f7495c9b414c22491fb/view"},"naics":{"codes":["334519"],"primary":"334519"},"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","agency":{"office":{"code":"SPMYM2","name":"DLA MARITIME - PUGET SOUND"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"98314-5000","city":"BREMERTON","state":"WA","country":"USA"},"organization_id":"500032826","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-21","archive_type":"auto15"},"history":[{"index":4,"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-23T15:19:26.869Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7af6020534834ccbae8f1cb7a5743afa","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":2,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T17:03:42.871Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"8c9b1026a2e44f7495c9b414c22491fb","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":1,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T16:58:46.424Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b","solicitation_number":"N4523A50853036"}],"contacts":[{"fax":"3604764121","name":"JACK EDWARDS","role":"primary","email":"JACK.EDWARDS@DLA.MIL","phone":"3608139577"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"8c9b1026a2e44f7495c9b414c22491fb","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"6064a69d06dd48beafdae5fbeb8a392b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T03:20:58.630428154Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"939e6b9f6bb8c2bd8ef5b2afc7eecdd5ab605338ef7ad1f53d9009f499ad685d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T03:20:58.630428154Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>SOURCES SOUGHT SYNOPSIS &nbsp;- PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</strong></p>\n\n<p>The Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.</p>\n\n<ol>\n\t<li>&nbsp;PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION &ndash; QTY 1</li>\n\t<li>MFG: GENERON</li>\n</ol>\n\n<p>SPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</p>\n\n<p>1. <u>SCOPE</u><u>:</u></p>\n\n<p>1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government</p>\n\n<p>for a &ldquo;Turnkey&rdquo; Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification</p>\n\n<p>provides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating</p>\n\n<p>System. This system should be designed to supply a continuous flow of nitrogen of a minimum of</p>\n\n<p>300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%</p>\n\n<p>(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.</p>\n\n<p>1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the</p>\n\n<p>Government&rsquo;s intent that a single (primary) contractor experienced in the production of membrane</p>\n\n<p>generating system technology in the marine industrial environment be awarded this contract and be</p>\n\n<p>responsible for the accomplishment of all work, including 3rd party certifications.</p>\n\n<p>2. <u>CONTAINER:</u></p>\n\n<p>2.1. The NPU shall be a stand-alone, &ldquo;Turnkey&rdquo; system. All components for the NPU should be installed</p>\n\n<p>within a max 8&rsquo; wide x 8&rsquo; high x 10&rsquo; long insulated, able to withstand when ambient temperatures drop to</p>\n\n<p>28&deg;F. ISO container, designed to permit relocation by crane, truck, and forklift.</p>\n\n<p>2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and</p>\n\n<p>should require only integration, assembly, operational verification and certification in final configuration</p>\n\n<p>to meet the contract specifications.</p>\n\n<p>2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative</p>\n\n<p>designs that improve system function, capacity, size, weight, or cost are encouraged to be included by the</p>\n\n<p>offeror in response.</p>\n\n<p>2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,</p>\n\n<p>snow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The</p>\n\n<p>operating environment is marine waterfront; therefore, components and coatings must be selected for</p>\n\n<p>protection from this corrosive environment.</p>\n\n<p>2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of</p>\n\n<p>300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and</p>\n\n<p>delivery of industrial grade Nitrogen. Operational performance design of the NPU should target the</p>\n\n<p>General Industrial usage.</p>\n\n<p>3. <u>SAMPLING REQUIREMENTS:</u></p>\n\n<p>3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally</p>\n\n<p>Recognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is</p>\n\n<p>properly marked with NRTL certification marking.</p>\n\n<p>4. <u>SET UP SERVICES AND TESTING</u>:</p>\n\n<p>4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and</p>\n\n<p>tested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall</p>\n\n<p>provide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen</p>\n\n<p>generator.</p>\n\n<p>4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.</p>\n\n<p>5. <u>TRAINING:</u></p>\n\n<p>5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of</p>\n\n<p>operation of the unit to include proper maintenance of the system. Customer will be charged at the current</p>\n\n<p>daily service rate, plus travel and living expenses.</p>\n\n<p>6. <u>NOISE:</u></p>\n\n<p>6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure</p>\n\n<p>ambient noise levels outside &lt;84db not to exceed &lt;103db and inside of the containerized unit &lt;104db not</p>\n\n<p>to exceed &lt;120db.</p>\n\n<p>7. <u>SOFTWARE:</u></p>\n\n<p>7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard</p>\n\n<p>factory set process control valve, Zirconium oxide oxygen analyzer.</p>\n\n<p>8. <u>REQUIREMENTS:</u></p>\n\n<p>8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After</p>\n\n<p>delivery, the unit shall require only the connection of power, routing of condensate, and testing in</p>\n\n<p>accordance with this specification.</p>\n\n<p>8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both</p>\n\n<p>in-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to</p>\n\n<p>certified standards that have known valid relationships to nationally accepted industry standards.</p>\n\n<p>8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of</p>\n\n<p>85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).</p>\n\n<p>8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be</p>\n\n<p>installed on the inlet piping.</p>\n\n<p>8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed</p>\n\n<p>through an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any</p>\n\n<p>Hydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built</p>\n\n<p>in .01 dust particulate wrap to ensure no carbon particulates enter the membranes.</p>\n\n<p>8.6. All electrical components to meet an area classification of Safe No Hazard.</p>\n\n<p>8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt</p>\n\n<p>supply, 480 Volt 3 Phase, 60 Hertz</p>\n\n<p>The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334519</p>\n\n<p><strong><u>THERE IS NO SOLICITATION AT THIS TIME.&nbsp;</u></strong>This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.&nbsp;</p>\n\n<p>If your organization has the potential capacity to provide these items, please provide the following information:</p>\n\n<ol>\n\t<li>Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,</li>\n\t<li>Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.</li>\n</ol>\n\n<p>Responses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil</p>\n\n<p>If you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil</p>\n\n<p>Attachments/Links</p>\n\n<p>No attachments or links have been added to this opportunity.</p>\n\n<p>Contact Information</p>\n\n<p>Contracting Office Address</p>\n\n<ul>\n\t<li>CONTRACTING DIVISION (DLA-PME) 467 W STREET</li>\n\t<li>BREMERTON, WA 98314-5000</li>\n\t<li>USA</li>\n</ul>\n\n<p>Primary Point of Contact</p>\n\n<ul>\n\t<li><strong>JACK EDWARDS</strong></li>\n\t<li>JACK.EDWARDS@DLA.MIL</li>\n\t<li>Phone Number&nbsp;360-813-9577</li>\n</ul>\n\n<p></p>\n\n<p></p>","text":"SOURCES SOUGHT SYNOPSIS - PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\nThe Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.\n\n• PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION – QTY 1\n\n• MFG: GENERON\n\nSPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\n1. SCOPE:\n\n1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government\n\nfor a “Turnkey” Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification\n\nprovides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating\n\nSystem. This system should be designed to supply a continuous flow of nitrogen of a minimum of\n\n300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%\n\n(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.\n\n1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the\n\nGovernment’s intent that a single (primary) contractor experienced in the production of membrane\n\ngenerating system technology in the marine industrial environment be awarded this contract and be\n\nresponsible for the accomplishment of all work, including 3rd party certifications.\n\n2. CONTAINER:\n\n2.1. The NPU shall be a stand-alone, “Turnkey” system. All components for the NPU should be installed\n\nwithin a max 8’ wide x 8’ high x 10’ long insulated, able to withstand when ambient temperatures drop to\n\n28°F. ISO container, designed to permit relocation by crane, truck, and forklift.\n\n2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and\n\nshould require only integration, assembly, operational verification and certification in final configuration\n\nto meet the contract specifications.\n\n2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative\n\ndesigns that improve system function, capacity, size, weight, or cost are encouraged to be included by the\n\nofferor in response.\n\n2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,\n\nsnow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The\n\noperating environment is marine waterfront; therefore, components and coatings must be selected for\n\nprotection from this corrosive environment.\n\n2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of\n\n300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and\n\ndelivery of industrial grade Nitrogen. Operational performance design of the NPU should target the\n\nGeneral Industrial usage.\n\n3. SAMPLING REQUIREMENTS:\n\n3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally\n\nRecognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is\n\nproperly marked with NRTL certification marking.\n\n4. SET UP SERVICES AND TESTING:\n\n4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and\n\ntested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall\n\nprovide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen\n\ngenerator.\n\n4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.\n\n5. TRAINING:\n\n5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of\n\noperation of the unit to include proper maintenance of the system. Customer will be charged at the current\n\ndaily service rate, plus travel and living expenses.\n\n6. NOISE:\n\n6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure\n\nambient noise levels outside <84db not to exceed <103db and inside of the containerized unit <104db not\n\nto exceed <120db.\n\n7. SOFTWARE:\n\n7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard\n\nfactory set process control valve, Zirconium oxide oxygen analyzer.\n\n8. REQUIREMENTS:\n\n8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After\n\ndelivery, the unit shall require only the connection of power, routing of condensate, and testing in\n\naccordance with this specification.\n\n8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both\n\nin-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to\n\ncertified standards that have known valid relationships to nationally accepted industry standards.\n\n8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of\n\n85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).\n\n8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be\n\ninstalled on the inlet piping.\n\n8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed\n\nthrough an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any\n\nHydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built\n\nin .01 dust particulate wrap to ensure no carbon particulates enter the membranes.\n\n8.6. All electrical components to meet an area classification of Safe No Hazard.\n\n8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt\n\nsupply, 480 Volt 3 Phase, 60 Hertz\n\nThe results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334519\n\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.\n\nIf your organization has the potential capacity to provide these items, please provide the following information:\n\n• Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,\n\n• Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.\n\nResponses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil\n\nIf you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil\n\nAttachments/Links\n\nNo attachments or links have been added to this opportunity.\n\nContact Information\n\nContracting Office Address\n\n• CONTRACTING DIVISION (DLA-PME) 467 W STREET\n\n• BREMERTON, WA 98314-5000\n\n• USA\n\nPrimary Point of Contact\n\n• JACK EDWARDS\n\n• JACK.EDWARDS@DLA.MIL\n\n• Phone Number 360-813-9577","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"N4523A50853036","place_of_performance":{"zip":"98314","city":{"code":"7695","name":"Bremerton"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6350"},{"dates":{"posted":"2025-04-23","posted_at":"2025-04-23T15:19:26.869Z","created_at":"2025-04-23T15:19:01.597Z","modified_at":"2025-05-22T03:55:52.133Z","response_deadline":{"raw":"2025-05-06T10:00:00-07:00","utc":"2025-05-06T17:00:00Z","date":"2025-05-06","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7af6020534834ccbae8f1cb7a5743afa/view"},"naics":{"codes":["334519"],"primary":"334519"},"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","agency":{"office":{"code":"SPMYM2","name":"DLA MARITIME - PUGET SOUND"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"98314-5000","city":"BREMERTON","state":"WA","country":"USA"},"organization_id":"500032826","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-21","archive_type":"auto15"},"history":[{"index":4,"title":"PORTABLE NITROGEN PRODUCTION UNIT -FIRE SUPPRESSION","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-23T15:19:26.869Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7af6020534834ccbae8f1cb7a5743afa","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":2,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T17:03:42.871Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"8c9b1026a2e44f7495c9b414c22491fb","solicitation_number":"N4523A50853036","parent_opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b"},{"index":1,"title":"PORTABLE NITROGEN PRODUCITON UNIT -FIRE SUPPRESSION","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-22T16:58:46.424Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6064a69d06dd48beafdae5fbeb8a392b","solicitation_number":"N4523A50853036"}],"contacts":[{"fax":"3604764121","name":"JACK EDWARDS","role":"primary","email":"JACK.EDWARDS@DLA.MIL","phone":"3608139577"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"7af6020534834ccbae8f1cb7a5743afa","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"6064a69d06dd48beafdae5fbeb8a392b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T02:32:32.333478390Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"e682c16c56175a035987216eeeed94d0639f0eb1f6f3d358bda04c3654bdf855","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T02:32:32.333478390Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>SOURCES SOUGHT SYNOPSIS &nbsp;- PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</strong></p>\n\n<p>The Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.</p>\n\n<ol>\n\t<li>&nbsp;PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION &ndash; QTY 1</li>\n\t<li>MFG: GENERON</li>\n</ol>\n\n<p>SPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</p>\n\n<p>1. <u>SCOPE</u><u>:</u></p>\n\n<p>1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government</p>\n\n<p>for a &ldquo;Turnkey&rdquo; Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification</p>\n\n<p>provides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating</p>\n\n<p>System. This system should be designed to supply a continuous flow of nitrogen of a minimum of</p>\n\n<p>300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%</p>\n\n<p>(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.</p>\n\n<p>1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the</p>\n\n<p>Government&rsquo;s intent that a single (primary) contractor experienced in the production of membrane</p>\n\n<p>generating system technology in the marine industrial environment be awarded this contract and be</p>\n\n<p>responsible for the accomplishment of all work, including 3rd party certifications.</p>\n\n<p>2. <u>CONTAINER:</u></p>\n\n<p>2.1. The NPU shall be a stand-alone, &ldquo;Turnkey&rdquo; system. All components for the NPU should be installed</p>\n\n<p>within a max 8&rsquo; wide x 8&rsquo; high x 10&rsquo; long insulated, able to withstand when ambient temperatures drop to</p>\n\n<p>28&deg;F. ISO container, designed to permit relocation by crane, truck, and forklift.</p>\n\n<p>2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and</p>\n\n<p>should require only integration, assembly, operational verification and certification in final configuration</p>\n\n<p>to meet the contract specifications.</p>\n\n<p>2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative</p>\n\n<p>designs that improve system function, capacity, size, weight, or cost are encouraged to be included by the</p>\n\n<p>offeror in response.</p>\n\n<p>2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,</p>\n\n<p>snow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The</p>\n\n<p>operating environment is marine waterfront; therefore, components and coatings must be selected for</p>\n\n<p>protection from this corrosive environment.</p>\n\n<p>2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of</p>\n\n<p>300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and</p>\n\n<p>delivery of industrial grade Nitrogen. Operational performance design of the NPU should target the</p>\n\n<p>General Industrial usage.</p>\n\n<p>3. <u>SAMPLING REQUIREMENTS:</u></p>\n\n<p>3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally</p>\n\n<p>Recognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is</p>\n\n<p>properly marked with NRTL certification marking.</p>\n\n<p>4. <u>SET UP SERVICES AND TESTING</u>:</p>\n\n<p>4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and</p>\n\n<p>tested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall</p>\n\n<p>provide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen</p>\n\n<p>generator.</p>\n\n<p>4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.</p>\n\n<p>5. <u>TRAINING:</u></p>\n\n<p>5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of</p>\n\n<p>operation of the unit to include proper maintenance of the system. Customer will be charged at the current</p>\n\n<p>daily service rate, plus travel and living expenses.</p>\n\n<p>6. <u>NOISE:</u></p>\n\n<p>6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure</p>\n\n<p>ambient noise levels outside &lt;84db not to exceed &lt;103db and inside of the containerized unit &lt;104db not</p>\n\n<p>to exceed &lt;120db.</p>\n\n<p>7. <u>SOFTWARE:</u></p>\n\n<p>7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard</p>\n\n<p>factory set process control valve, Zirconium oxide oxygen analyzer.</p>\n\n<p>8. <u>REQUIREMENTS:</u></p>\n\n<p>8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After</p>\n\n<p>delivery, the unit shall require only the connection of power, routing of condensate, and testing in</p>\n\n<p>accordance with this specification.</p>\n\n<p>8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both</p>\n\n<p>in-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to</p>\n\n<p>certified standards that have known valid relationships to nationally accepted industry standards.</p>\n\n<p>8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of</p>\n\n<p>85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).</p>\n\n<p>8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be</p>\n\n<p>installed on the inlet piping.</p>\n\n<p>8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed</p>\n\n<p>through an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any</p>\n\n<p>Hydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built</p>\n\n<p>in .01 dust particulate wrap to ensure no carbon particulates enter the membranes.</p>\n\n<p>8.6. All electrical components to meet an area classification of Safe No Hazard.</p>\n\n<p>8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt</p>\n\n<p>supply, 480 Volt 3 Phase, 60 Hertz</p>\n\n<p>The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334519</p>\n\n<p><strong><u>THERE IS NO SOLICITATION AT THIS TIME.&nbsp;</u></strong>This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.&nbsp;</p>\n\n<p>If your organization has the potential capacity to provide these items, please provide the following information:</p>\n\n<ol>\n\t<li>Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,</li>\n\t<li>Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.</li>\n</ol>\n\n<p>Responses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil</p>\n\n<p>If you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil</p>\n\n<p>Attachments/Links</p>\n\n<p>No attachments or links have been added to this opportunity.</p>\n\n<p>Contact Information</p>\n\n<p>Contracting Office Address</p>\n\n<ul>\n\t<li>CONTRACTING DIVISION (DLA-PME) 467 W STREET</li>\n\t<li>BREMERTON, WA 98314-5000</li>\n\t<li>USA</li>\n</ul>\n\n<p>Primary Point of Contact</p>\n\n<ul>\n\t<li><strong>JACK EDWARDS</strong></li>\n\t<li>JACK.EDWARDS@DLA.MIL</li>\n\t<li>Phone Number&nbsp;360-813-9577</li>\n</ul>\n\n<p></p>\n\n<p></p>","text":"SOURCES SOUGHT SYNOPSIS - PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\nThe Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.\n\n• PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION – QTY 1\n\n• MFG: GENERON\n\nSPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\n1. SCOPE:\n\n1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government\n\nfor a “Turnkey” Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification\n\nprovides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating\n\nSystem. This system should be designed to supply a continuous flow of nitrogen of a minimum of\n\n300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%\n\n(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.\n\n1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the\n\nGovernment’s intent that a single (primary) contractor experienced in the production of membrane\n\ngenerating system technology in the marine industrial environment be awarded this contract and be\n\nresponsible for the accomplishment of all work, including 3rd party certifications.\n\n2. CONTAINER:\n\n2.1. The NPU shall be a stand-alone, “Turnkey” system. All components for the NPU should be installed\n\nwithin a max 8’ wide x 8’ high x 10’ long insulated, able to withstand when ambient temperatures drop to\n\n28°F. ISO container, designed to permit relocation by crane, truck, and forklift.\n\n2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and\n\nshould require only integration, assembly, operational verification and certification in final configuration\n\nto meet the contract specifications.\n\n2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative\n\ndesigns that improve system function, capacity, size, weight, or cost are encouraged to be included by the\n\nofferor in response.\n\n2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,\n\nsnow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The\n\noperating environment is marine waterfront; therefore, components and coatings must be selected for\n\nprotection from this corrosive environment.\n\n2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of\n\n300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and\n\ndelivery of industrial grade Nitrogen. Operational performance design of the NPU should target the\n\nGeneral Industrial usage.\n\n3. SAMPLING REQUIREMENTS:\n\n3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally\n\nRecognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is\n\nproperly marked with NRTL certification marking.\n\n4. SET UP SERVICES AND TESTING:\n\n4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and\n\ntested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall\n\nprovide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen\n\ngenerator.\n\n4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.\n\n5. TRAINING:\n\n5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of\n\noperation of the unit to include proper maintenance of the system. Customer will be charged at the current\n\ndaily service rate, plus travel and living expenses.\n\n6. NOISE:\n\n6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure\n\nambient noise levels outside <84db not to exceed <103db and inside of the containerized unit <104db not\n\nto exceed <120db.\n\n7. SOFTWARE:\n\n7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard\n\nfactory set process control valve, Zirconium oxide oxygen analyzer.\n\n8. REQUIREMENTS:\n\n8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After\n\ndelivery, the unit shall require only the connection of power, routing of condensate, and testing in\n\naccordance with this specification.\n\n8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both\n\nin-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to\n\ncertified standards that have known valid relationships to nationally accepted industry standards.\n\n8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of\n\n85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).\n\n8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be\n\ninstalled on the inlet piping.\n\n8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed\n\nthrough an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any\n\nHydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built\n\nin .01 dust particulate wrap to ensure no carbon particulates enter the membranes.\n\n8.6. All electrical components to meet an area classification of Safe No Hazard.\n\n8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt\n\nsupply, 480 Volt 3 Phase, 60 Hertz\n\nThe results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334519\n\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.\n\nIf your organization has the potential capacity to provide these items, please provide the following information:\n\n• Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,\n\n• Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.\n\nResponses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil\n\nIf you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil\n\nAttachments/Links\n\nNo attachments or links have been added to this opportunity.\n\nContact Information\n\nContracting Office Address\n\n• CONTRACTING DIVISION (DLA-PME) 467 W STREET\n\n• BREMERTON, WA 98314-5000\n\n• USA\n\nPrimary Point of Contact\n\n• JACK EDWARDS\n\n• JACK.EDWARDS@DLA.MIL\n\n• Phone Number 360-813-9577","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"N4523A50853036","place_of_performance":{"zip":"98314","city":{"code":"7695","name":"Bremerton"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6350"}],"due_at":"2025-05-06T17:00:00Z","due_date":"2025-05-06","closes_at":"2025-05-06T17:00:00Z","awardable":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-17T02:40:39.993101Z","principal_notice_id":"7af6020534834ccbae8f1cb7a5743afa","description":{"text":"SOURCES SOUGHT SYNOPSIS - PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\nThe Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.\n\n• PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION – QTY 1\n\n• MFG: GENERON\n\nSPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION\n\n1. SCOPE:\n\n1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government\n\nfor a “Turnkey” Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification\n\nprovides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating\n\nSystem. This system should be designed to supply a continuous flow of nitrogen of a minimum of\n\n300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%\n\n(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.\n\n1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the\n\nGovernment’s intent that a single (primary) contractor experienced in the production of membrane\n\ngenerating system technology in the marine industrial environment be awarded this contract and be\n\nresponsible for the accomplishment of all work, including 3rd party certifications.\n\n2. CONTAINER:\n\n2.1. The NPU shall be a stand-alone, “Turnkey” system. All components for the NPU should be installed\n\nwithin a max 8’ wide x 8’ high x 10’ long insulated, able to withstand when ambient temperatures drop to\n\n28°F. ISO container, designed to permit relocation by crane, truck, and forklift.\n\n2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and\n\nshould require only integration, assembly, operational verification and certification in final configuration\n\nto meet the contract specifications.\n\n2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative\n\ndesigns that improve system function, capacity, size, weight, or cost are encouraged to be included by the\n\nofferor in response.\n\n2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,\n\nsnow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The\n\noperating environment is marine waterfront; therefore, components and coatings must be selected for\n\nprotection from this corrosive environment.\n\n2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of\n\n300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and\n\ndelivery of industrial grade Nitrogen. Operational performance design of the NPU should target the\n\nGeneral Industrial usage.\n\n3. SAMPLING REQUIREMENTS:\n\n3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally\n\nRecognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is\n\nproperly marked with NRTL certification marking.\n\n4. SET UP SERVICES AND TESTING:\n\n4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and\n\ntested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall\n\nprovide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen\n\ngenerator.\n\n4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.\n\n5. TRAINING:\n\n5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of\n\noperation of the unit to include proper maintenance of the system. Customer will be charged at the current\n\ndaily service rate, plus travel and living expenses.\n\n6. NOISE:\n\n6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure\n\nambient noise levels outside <84db not to exceed <103db and inside of the containerized unit <104db not\n\nto exceed <120db.\n\n7. SOFTWARE:\n\n7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard\n\nfactory set process control valve, Zirconium oxide oxygen analyzer.\n\n8. REQUIREMENTS:\n\n8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After\n\ndelivery, the unit shall require only the connection of power, routing of condensate, and testing in\n\naccordance with this specification.\n\n8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both\n\nin-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to\n\ncertified standards that have known valid relationships to nationally accepted industry standards.\n\n8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of\n\n85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).\n\n8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be\n\ninstalled on the inlet piping.\n\n8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed\n\nthrough an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any\n\nHydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built\n\nin .01 dust particulate wrap to ensure no carbon particulates enter the membranes.\n\n8.6. All electrical components to meet an area classification of Safe No Hazard.\n\n8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt\n\nsupply, 480 Volt 3 Phase, 60 Hertz\n\nThe results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334519\n\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.\n\nIf your organization has the potential capacity to provide these items, please provide the following information:\n\n• Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,\n\n• Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.\n\nResponses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil\n\nIf you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil\n\nAttachments/Links\n\nNo attachments or links have been added to this opportunity.\n\nContact Information\n\nContracting Office Address\n\n• CONTRACTING DIVISION (DLA-PME) 467 W STREET\n\n• BREMERTON, WA 98314-5000\n\n• USA\n\nPrimary Point of Contact\n\n• JACK EDWARDS\n\n• JACK.EDWARDS@DLA.MIL\n\n• Phone Number 360-813-9577","html":"<p><strong>SOURCES SOUGHT SYNOPSIS &nbsp;- PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</strong></p>\n\n<p>The Defense Logistics Agency Maritime Puget Sound is issuing this sources sought and request for information as a means of conducting market research to identify parties having an interest in and the resources to support a material requirement in Bremerton, WA.</p>\n\n<ol>\n\t<li>&nbsp;PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION &ndash; QTY 1</li>\n\t<li>MFG: GENERON</li>\n</ol>\n\n<p>SPECIFICATION FOR PORTABLE NITROGEN PRODUCTION UNIT FOR FIRE SUPPRESSION</p>\n\n<p>1. <u>SCOPE</u><u>:</u></p>\n\n<p>1.1. This specification reflects those characteristics that are essential to the minimum needs of the Government</p>\n\n<p>for a &ldquo;Turnkey&rdquo; Portable Nitrogen Production Unit for Fire Suppression (NPU). This specification</p>\n\n<p>provides the performance standards for purchase of an electrically driven; Nitrogen Membrane Generating</p>\n\n<p>System. This system should be designed to supply a continuous flow of nitrogen of a minimum of</p>\n\n<p>300CFM with a minimum working pressure of 85PSIG to 100PSIG, at a minimum nitrogen purity of 95%</p>\n\n<p>(Nitrogen Purity + Inerts). Feed air at a maximum of 625 CFM.</p>\n\n<p>1.2. This contract includes setup, testing, startup assistance, training, and on-site technical support. It is the</p>\n\n<p>Government&rsquo;s intent that a single (primary) contractor experienced in the production of membrane</p>\n\n<p>generating system technology in the marine industrial environment be awarded this contract and be</p>\n\n<p>responsible for the accomplishment of all work, including 3rd party certifications.</p>\n\n<p>2. <u>CONTAINER:</u></p>\n\n<p>2.1. The NPU shall be a stand-alone, &ldquo;Turnkey&rdquo; system. All components for the NPU should be installed</p>\n\n<p>within a max 8&rsquo; wide x 8&rsquo; high x 10&rsquo; long insulated, able to withstand when ambient temperatures drop to</p>\n\n<p>28&deg;F. ISO container, designed to permit relocation by crane, truck, and forklift.</p>\n\n<p>2.2. The components utilized for the design of this system are commercially available off the shelf (COTS) and</p>\n\n<p>should require only integration, assembly, operational verification and certification in final configuration</p>\n\n<p>to meet the contract specifications.</p>\n\n<p>2.3. The proposed layout of equipment will be based on average component sizing across industry. Innovative</p>\n\n<p>designs that improve system function, capacity, size, weight, or cost are encouraged to be included by the</p>\n\n<p>offeror in response.</p>\n\n<p>2.4. The NPU shall be designed for operation at sea-level altitude, in the weather exposed to sun, freezing rain,</p>\n\n<p>snow, sleet, high and low temperatures, high and low humidity, and other climactic extremes. The</p>\n\n<p>operating environment is marine waterfront; therefore, components and coatings must be selected for</p>\n\n<p>protection from this corrosive environment.</p>\n\n<p>2.5. The NPU capacity at the outlet of the shipping container shall be capable of delivering minimum of</p>\n\n<p>300CFM with a minimum of 95% purity while meeting all requirements for production, handling, and</p>\n\n<p>delivery of industrial grade Nitrogen. Operational performance design of the NPU should target the</p>\n\n<p>General Industrial usage.</p>\n\n<p>3. <u>SAMPLING REQUIREMENTS:</u></p>\n\n<p>3.1. The NPU shall be NRTL certified. The offeror will obtain and provide independent 3rd party Nationally</p>\n\n<p>Recognized Testing Laboratory (NRTL) certification listing for the NPU and ensure NPU assembly is</p>\n\n<p>properly marked with NRTL certification marking.</p>\n\n<p>4. <u>SET UP SERVICES AND TESTING</u>:</p>\n\n<p>4.1. A certified technician for the nitrogen generator and all associated equipment shall be assembled, set-up and</p>\n\n<p>tested by the contractor in the area(s) designated as the test area by the receiving activity. The Contractor shall</p>\n\n<p>provide all personnel, equipment, and supplies necessary for the complete set-up and testing of the nitrogen</p>\n\n<p>generator.</p>\n\n<p>4.2. Two (2) paper copy of shutdown, startup, operating, and maintenance procedures in English.</p>\n\n<p>5. <u>TRAINING:</u></p>\n\n<p>5.1. Training can be performed on-site at the receiving facility upon arrival of the unit. Training will consist of</p>\n\n<p>operation of the unit to include proper maintenance of the system. Customer will be charged at the current</p>\n\n<p>daily service rate, plus travel and living expenses.</p>\n\n<p>6. <u>NOISE:</u></p>\n\n<p>6.1. Obtain, provide, and install an active industrial noise suppression system inside of the NPU to ensure</p>\n\n<p>ambient noise levels outside &lt;84db not to exceed &lt;103db and inside of the containerized unit &lt;104db not</p>\n\n<p>to exceed &lt;120db.</p>\n\n<p>7. <u>SOFTWARE:</u></p>\n\n<p>7.1. HMI: Displays oxygen content, feed pressure, Nitrogen pressure, run status, maintenance hours, standard</p>\n\n<p>factory set process control valve, Zirconium oxide oxygen analyzer.</p>\n\n<p>8. <u>REQUIREMENTS:</u></p>\n\n<p>8.1. The NPU shall be a complete and operational system, delivered assembled, piped, wired, and tested. After</p>\n\n<p>delivery, the unit shall require only the connection of power, routing of condensate, and testing in</p>\n\n<p>accordance with this specification.</p>\n\n<p>8.2. Provide calibration gas (GASCO 103L-159-10 or similar), calibration rig, and procedures to verify both</p>\n\n<p>in-situ (installed) O2 sensors can accurately measure a minimum purity of 95% that is calibrated to</p>\n\n<p>certified standards that have known valid relationships to nationally accepted industry standards.</p>\n\n<p>8.3. Supply a continuous flow of nitrogen from minimum of 300CFM with a minimum working pressure of</p>\n\n<p>85PSIG to 100PSIG, at a minimum nitrogen purity of 95% (Nitrogen Purity + Inerts).</p>\n\n<p>8.4. If membrane required specific temperature range to meet operational conditions a process heater shall be</p>\n\n<p>installed on the inlet piping.</p>\n\n<p>8.5. After the feed air heating step, the Feed Air is passed through another conditioning step. The feed air is passed</p>\n\n<p>through an Activated Carbon filter. The activated carbon is utilized to remove from the feed air any</p>\n\n<p>Hydrocarbons that may be present in the air stream as a result of the compression process. The filter has a built</p>\n\n<p>in .01 dust particulate wrap to ensure no carbon particulates enter the membranes.</p>\n\n<p>8.6. All electrical components to meet an area classification of Safe No Hazard.</p>\n\n<p>8.7. Power supply: 120 Volt, 1 Phase, 60 Hertz authorized to be supplied through a transformer on the 480 Volt</p>\n\n<p>supply, 480 Volt 3 Phase, 60 Hertz</p>\n\n<p>The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334519</p>\n\n<p><strong><u>THERE IS NO SOLICITATION AT THIS TIME.&nbsp;</u></strong>This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.&nbsp;</p>\n\n<p>If your organization has the potential capacity to provide these items, please provide the following information:</p>\n\n<ol>\n\t<li>Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization, including vendor CAGE code; and,</li>\n\t<li>Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.</li>\n</ol>\n\n<p>Responses are due in this office no later than 10:00 a.m. PDT, 6 MAY, 2025. Please send your capabilities statements and responses to this RFI via email directly to: jack.edwards@dla.mil</p>\n\n<p>If you have any questions concerning this opportunity, please contact: jack.edwards@dla.mil</p>\n\n<p>Attachments/Links</p>\n\n<p>No attachments or links have been added to this opportunity.</p>\n\n<p>Contact Information</p>\n\n<p>Contracting Office Address</p>\n\n<ul>\n\t<li>CONTRACTING DIVISION (DLA-PME) 467 W STREET</li>\n\t<li>BREMERTON, WA 98314-5000</li>\n\t<li>USA</li>\n</ul>\n\n<p>Primary Point of Contact</p>\n\n<ul>\n\t<li><strong>JACK EDWARDS</strong></li>\n\t<li>JACK.EDWARDS@DLA.MIL</li>\n\t<li>Phone Number&nbsp;360-813-9577</li>\n</ul>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"fax":"3604764121","name":"JACK EDWARDS","role":"primary","email":"JACK.EDWARDS@DLA.MIL","phone":"3608139577"}],"place_of_performance":{"zip":"98314","city":{"code":"7695","name":"Bremerton"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"98314-5000","city":"BREMERTON","state":"WA","country":"USA"},"naics_codes":["334519"],"award":null,"attachments":[],"awards":[],"related":[{"key":"SPMYM227Q0216","latest_notice_id":"68d97a47c2534703969754d96afbe561","title":"CASE HYD AMP 7.250 (SOLE SOURCE)","solicitation_number":"SPMYM227Q0216","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"333998","psc":"5360","set_aside":"SDVOSBC","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"SPMYM227Q0218","latest_notice_id":"c1fd0c07379643068511ec96b3b25c5b","title":"AREA MONITOR","solicitation_number":"SPMYM227Q0218","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-26T01:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"334511","psc":"6665","set_aside":null,"state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SPMYM227Q0208","latest_notice_id":"8b9e283c0f6a4722b0b2f2c79581d3f7","title":"Gasket","solicitation_number":"SPMYM227Q0208","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"339991","psc":"5330","set_aside":"SBA","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SPMYM227Q0231","latest_notice_id":"4bb52e9e2a464c7c80d01932811fbbcd","title":"SPMYM227Q0231 FOLDING PARTITION","solicitation_number":"SPMYM227Q0231","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"332510","psc":"5670","set_aside":"SBA","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SPMYM227Q1173","latest_notice_id":"367c00d1aa96482a9edf72c61d5f9561","title":"BOOTEE CANVAS IDIQ","solicitation_number":"SPMYM227Q1173","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-27T23:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"315990","psc":"8415","set_aside":"SBA","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"SPMYM227Q0051","latest_notice_id":"442d290f643b4cc88f24a08b2f7a583b","title":"PROBE EDDY CURRENT","solicitation_number":"SPMYM227Q0051","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2027-11-19T23:00:00Z","due_date":"2027-11-19","closes_at":"2027-11-19T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"334519","psc":"6635","set_aside":"SBA","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"1178021","latest_notice_id":"c4173d50f35d4be780dc718d2fdf88f1","title":"HPLC Core System","solicitation_number":"1178021","notice_type":"p","first_type":"p","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12G2","sub_name":"FOOD SAFETY AND INSPECTION SERVICE","office_key":"o-123A94","office_name":"USDA, FSIS, OAS PCMB","naics":"334519","psc":"H252","set_aside":null,"state":"FL","county":"12086","county_name":"Miami-Dade County","city":"1214250","city_name":"Coral Gables","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"SPE4A527T3404","latest_notice_id":"a34ef49f30ec469a97cb56c10001377c","title":"66--ADAPTER,SPEEDOMETER","solicitation_number":"SPE4A527T3404","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A5","office_name":"DLA AVIATION","naics":"334519","psc":"66","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TER: LINE 0001 QTY 469 UI EA DELIVER TO: W1A8 DLA DIST SAN JOAQUIN BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":49,"indexable":false}