{"canonical":"https://sealedbidder.com/opportunities/n4215826sn001","key":"N4215826SN001","url":"https://sealedbidder.com/opportunities/n4215826sn001","title":"Temp Chiller Rental","solicitation_number":"N4215826SN001","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-15T21:00:00Z","first_posted":"2026-04-13","last_posted":"2026-04-13","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NORFOLK NAVAL SHIPYARD GF","naics":"532490","psc":"W035","set_aside":null,"place_state":"SC","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"45015","place_county_name":"Berkeley County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"c94cac6e269c424fb06af745825b170a","title":"Temp Chiller Rental","solicitation_number":"N4215826SN001","notice_type":"p","base_type":"p","posted":"2026-04-13","posted_at":"2026-04-13T18:38:31.698Z","due_at":"2026-04-15T21:00:00Z","due_date":"2026-04-15","cancelled":false,"archived":true,"archive_date":"2026-04-30","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c94cac6e269c424fb06af745825b170a/view","enriched":true,"history":[{"index":3,"title":"Temp Chiller Rental","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-13T18:38:31.698Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c94cac6e269c424fb06af745825b170a","solicitation_number":"N4215826SN001"}]}],"latest_notice_id":"c94cac6e269c424fb06af745825b170a","first_type":"p","notices":[{"dates":{"posted":"2026-04-13","posted_at":"2026-04-13T18:38:31.698Z","created_at":"2026-04-13T18:33:44.706Z","modified_at":"2026-05-01T03:55:44.397Z","response_deadline":{"raw":"2026-04-15T17:00:00-04:00","utc":"2026-04-15T21:00:00Z","date":"2026-04-15","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c94cac6e269c424fb06af745825b170a/view"},"naics":{"codes":["532490"],"primary":"532490"},"title":"Temp Chiller Rental","agency":{"office":{"code":"N42158","name":"NORFOLK NAVAL SHIPYARD GF"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"23709-1001","city":"PORTSMOUTH","state":"VA","country":"USA"},"organization_id":"500021471","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-30","archive_type":"auto15"},"history":[{"index":3,"title":"Temp Chiller Rental","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-13T18:38:31.698Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c94cac6e269c424fb06af745825b170a","solicitation_number":"N4215826SN001"}],"contacts":[{"name":"Gordon Weston","role":"primary","email":"gordon.t.weston3.civ@us.navy.mil","phone":"7573960964"},{"name":"Rebekah Riggins","role":"secondary","email":"rebekah.r.riggins.civ@us.navy.mil","phone":"7579674014"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"c94cac6e269c424fb06af745825b170a","lineage_id":"c94cac6e269c424fb06af745825b170a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-07T02:23:38.264089450Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"5de40398396f9ac27b02f0e1a56504ae30dfd51dff29b2ad39b0c6a16a4ea2f4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-07T02:23:38.264089450Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Chill Water Unit shall be a minimum 150 Ton Capacity Chiller.</p>\n\n<p>Must be air-cooled.</p>\n\n<p>Must be operable on a single 460/480 (V), <u>400 Amp</u> Breaker (<u>MAXIMUM</u>).</p>\n\n<p>Must be provided with a male 500 mcm Camlock electrical connection.</p>\n\n<p>Single Circulating pump (minimum).</p>\n\n<p><strong>CRITICAL SYSTEM SUPPORT: Unit must be capable of operating twenty-four (24) hours a day, seven (7) days a Week.</strong></p>\n\n<p>At a minimum, the pumping system shall be capable of providing 450 GPM at 300 feet of head pressure.&nbsp; Supplemental pumps may be provided if needed to meet required pressure/flow rates, but a pump integral to the chiller unit would be preferred.</p>\n\n<p>Unit must have two (2) each inlets. Inlets must be 2-1/2&rdquo; Male NPT. All inlet connections shall have isolation globe valves installed.</p>\n\n<p>Unit must have two (2) each outlets. Outlets must be 2-1/2&rdquo; Male NPT. All outlet connections shall have isolation globe valves installed.</p>\n\n<p>The gross weight of the unit shall be clearly marked on the outside of the unit as outlined in Paragraph 11.&nbsp; If the unit is not a complete unit, the gross weight of each component shall be clearly marked on each component.</p>\n\n<p>Unit must be free standing and have forklift slots (capable of being moved with a forklift).&nbsp; If the unit is not a complete unit, each component shall be capable of being moved with a forklift as well.</p>\n\n<p>Chiller Unit to be equipped with <u>operational</u> Inlet and Outlet Pressure Gages.&nbsp; Pressure gages are to be located on the contractor provided supply and discharge manifolds.</p>\n\n<p>Unit shall have an electronic monitoring system that monitors inlet and outlet temperatures and flow rates.</p>\n\n<p>Desired output water temperature range is 45&deg; F - 55&deg; F.</p>\n\n<p>Evaporator must be capable of delivering a leaving temperature of less than 45 &deg;F.</p>\n\n<p>Condenser must be capable of operating in a wide ambient temperature range (0-125 &deg;F).</p>\n\n<p>Shown in figure below, Contractor is to provide all equipment from the return manifold to the supply manifold. &nbsp;System shall be a complete unit.&nbsp; If pump is separate, vendor will provide and install all piping/valves/fittings as required to couple pump to the Chill Water Unit. &nbsp;Vendor is to provide extra fittings and hoses to support installation, as required. If the system requires assembly, the system shall be assembled in such a way that it does not cause tripping hazards by minimizing the lengths of hoses between components.&nbsp; If lengths of hoses are longer than needed, it should be able to be coiled and put somewhere out of the way of normal foot traffic.&nbsp; Hoses shall be routed in a way that does not cause the hose to kink and reduce flowrate.</p>\n\n<p>If chiller system holds 55 gallons or more of fuel or oil or similar fluid, provide an environmental catch tank capable of holding at least 110% of the capacity of the fuel, oil and other fluids required to operate the rental unit.</p>\n\n<p>Unit must be affixed with a metal tag designating the supplying company, a POC responsible for repairs and maintenance, and a phone number for the POC who is responsible for repairs and maintenance.</p>\n\n<p>Contractor must provide instruction manual and training as requested.</p>\n\n<p>Contractor provided equipment (i.e. hoses, manifolds, etc.) shall have insulation installed around them to reduce temperature losses in the Chill Water System.</p>\n\n<p></p>\n\n<p>Interested vendors should notify contract speicialist of their interest</p>","text":"Chill Water Unit shall be a minimum 150 Ton Capacity Chiller.\n\nMust be air-cooled.\n\nMust be operable on a single 460/480 (V), 400 Amp Breaker (MAXIMUM).\n\nMust be provided with a male 500 mcm Camlock electrical connection.\n\nSingle Circulating pump (minimum).\n\nCRITICAL SYSTEM SUPPORT: Unit must be capable of operating twenty-four (24) hours a day, seven (7) days a Week.\n\nAt a minimum, the pumping system shall be capable of providing 450 GPM at 300 feet of head pressure. Supplemental pumps may be provided if needed to meet required pressure/flow rates, but a pump integral to the chiller unit would be preferred.\n\nUnit must have two (2) each inlets. Inlets must be 2-1/2” Male NPT. All inlet connections shall have isolation globe valves installed.\n\nUnit must have two (2) each outlets. Outlets must be 2-1/2” Male NPT. All outlet connections shall have isolation globe valves installed.\n\nThe gross weight of the unit shall be clearly marked on the outside of the unit as outlined in Paragraph 11. If the unit is not a complete unit, the gross weight of each component shall be clearly marked on each component.\n\nUnit must be free standing and have forklift slots (capable of being moved with a forklift). If the unit is not a complete unit, each component shall be capable of being moved with a forklift as well.\n\nChiller Unit to be equipped with operational Inlet and Outlet Pressure Gages. Pressure gages are to be located on the contractor provided supply and discharge manifolds.\n\nUnit shall have an electronic monitoring system that monitors inlet and outlet temperatures and flow rates.\n\nDesired output water temperature range is 45° F - 55° F.\n\nEvaporator must be capable of delivering a leaving temperature of less than 45 °F.\n\nCondenser must be capable of operating in a wide ambient temperature range (0-125 °F).\n\nShown in figure below, Contractor is to provide all equipment from the return manifold to the supply manifold. System shall be a complete unit. If pump is separate, vendor will provide and install all piping/valves/fittings as required to couple pump to the Chill Water Unit. Vendor is to provide extra fittings and hoses to support installation, as required. If the system requires assembly, the system shall be assembled in such a way that it does not cause tripping hazards by minimizing the lengths of hoses between components. If lengths of hoses are longer than needed, it should be able to be coiled and put somewhere out of the way of normal foot traffic. Hoses shall be routed in a way that does not cause the hose to kink and reduce flowrate.\n\nIf chiller system holds 55 gallons or more of fuel or oil or similar fluid, provide an environmental catch tank capable of holding at least 110% of the capacity of the fuel, oil and other fluids required to operate the rental unit.\n\nUnit must be affixed with a metal tag designating the supplying company, a POC responsible for repairs and maintenance, and a phone number for the POC who is responsible for repairs and maintenance.\n\nContractor must provide instruction manual and training as requested.\n\nContractor provided equipment (i.e. hoses, manifolds, etc.) shall have insulation installed around them to reduce temperature losses in the Chill Water System.\n\nInterested vendors should notify contract speicialist of their interest","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"N4215826SN001","place_of_performance":{"zip":"29445","state":{"code":"SC","name":"South Carolina"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"W035"}],"due_at":"2026-04-15T21:00:00Z","due_date":"2026-04-15","closes_at":"2026-04-15T21:00:00Z","awardable":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","state":"SC","county":"45015","county_name":"Berkeley County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-07T03:08:43.848347Z","principal_notice_id":"c94cac6e269c424fb06af745825b170a","description":{"text":"Chill Water Unit shall be a minimum 150 Ton Capacity Chiller.\n\nMust be air-cooled.\n\nMust be operable on a single 460/480 (V), 400 Amp Breaker (MAXIMUM).\n\nMust be provided with a male 500 mcm Camlock electrical connection.\n\nSingle Circulating pump (minimum).\n\nCRITICAL SYSTEM SUPPORT: Unit must be capable of operating twenty-four (24) hours a day, seven (7) days a Week.\n\nAt a minimum, the pumping system shall be capable of providing 450 GPM at 300 feet of head pressure. Supplemental pumps may be provided if needed to meet required pressure/flow rates, but a pump integral to the chiller unit would be preferred.\n\nUnit must have two (2) each inlets. Inlets must be 2-1/2” Male NPT. All inlet connections shall have isolation globe valves installed.\n\nUnit must have two (2) each outlets. Outlets must be 2-1/2” Male NPT. All outlet connections shall have isolation globe valves installed.\n\nThe gross weight of the unit shall be clearly marked on the outside of the unit as outlined in Paragraph 11. If the unit is not a complete unit, the gross weight of each component shall be clearly marked on each component.\n\nUnit must be free standing and have forklift slots (capable of being moved with a forklift). If the unit is not a complete unit, each component shall be capable of being moved with a forklift as well.\n\nChiller Unit to be equipped with operational Inlet and Outlet Pressure Gages. Pressure gages are to be located on the contractor provided supply and discharge manifolds.\n\nUnit shall have an electronic monitoring system that monitors inlet and outlet temperatures and flow rates.\n\nDesired output water temperature range is 45° F - 55° F.\n\nEvaporator must be capable of delivering a leaving temperature of less than 45 °F.\n\nCondenser must be capable of operating in a wide ambient temperature range (0-125 °F).\n\nShown in figure below, Contractor is to provide all equipment from the return manifold to the supply manifold. System shall be a complete unit. If pump is separate, vendor will provide and install all piping/valves/fittings as required to couple pump to the Chill Water Unit. Vendor is to provide extra fittings and hoses to support installation, as required. If the system requires assembly, the system shall be assembled in such a way that it does not cause tripping hazards by minimizing the lengths of hoses between components. If lengths of hoses are longer than needed, it should be able to be coiled and put somewhere out of the way of normal foot traffic. Hoses shall be routed in a way that does not cause the hose to kink and reduce flowrate.\n\nIf chiller system holds 55 gallons or more of fuel or oil or similar fluid, provide an environmental catch tank capable of holding at least 110% of the capacity of the fuel, oil and other fluids required to operate the rental unit.\n\nUnit must be affixed with a metal tag designating the supplying company, a POC responsible for repairs and maintenance, and a phone number for the POC who is responsible for repairs and maintenance.\n\nContractor must provide instruction manual and training as requested.\n\nContractor provided equipment (i.e. hoses, manifolds, etc.) shall have insulation installed around them to reduce temperature losses in the Chill Water System.\n\nInterested vendors should notify contract speicialist of their interest","html":"<p>Chill Water Unit shall be a minimum 150 Ton Capacity Chiller.</p>\n\n<p>Must be air-cooled.</p>\n\n<p>Must be operable on a single 460/480 (V), <u>400 Amp</u> Breaker (<u>MAXIMUM</u>).</p>\n\n<p>Must be provided with a male 500 mcm Camlock electrical connection.</p>\n\n<p>Single Circulating pump (minimum).</p>\n\n<p><strong>CRITICAL SYSTEM SUPPORT: Unit must be capable of operating twenty-four (24) hours a day, seven (7) days a Week.</strong></p>\n\n<p>At a minimum, the pumping system shall be capable of providing 450 GPM at 300 feet of head pressure.&nbsp; Supplemental pumps may be provided if needed to meet required pressure/flow rates, but a pump integral to the chiller unit would be preferred.</p>\n\n<p>Unit must have two (2) each inlets. Inlets must be 2-1/2&rdquo; Male NPT. All inlet connections shall have isolation globe valves installed.</p>\n\n<p>Unit must have two (2) each outlets. Outlets must be 2-1/2&rdquo; Male NPT. All outlet connections shall have isolation globe valves installed.</p>\n\n<p>The gross weight of the unit shall be clearly marked on the outside of the unit as outlined in Paragraph 11.&nbsp; If the unit is not a complete unit, the gross weight of each component shall be clearly marked on each component.</p>\n\n<p>Unit must be free standing and have forklift slots (capable of being moved with a forklift).&nbsp; If the unit is not a complete unit, each component shall be capable of being moved with a forklift as well.</p>\n\n<p>Chiller Unit to be equipped with <u>operational</u> Inlet and Outlet Pressure Gages.&nbsp; Pressure gages are to be located on the contractor provided supply and discharge manifolds.</p>\n\n<p>Unit shall have an electronic monitoring system that monitors inlet and outlet temperatures and flow rates.</p>\n\n<p>Desired output water temperature range is 45&deg; F - 55&deg; F.</p>\n\n<p>Evaporator must be capable of delivering a leaving temperature of less than 45 &deg;F.</p>\n\n<p>Condenser must be capable of operating in a wide ambient temperature range (0-125 &deg;F).</p>\n\n<p>Shown in figure below, Contractor is to provide all equipment from the return manifold to the supply manifold. &nbsp;System shall be a complete unit.&nbsp; If pump is separate, vendor will provide and install all piping/valves/fittings as required to couple pump to the Chill Water Unit. &nbsp;Vendor is to provide extra fittings and hoses to support installation, as required. If the system requires assembly, the system shall be assembled in such a way that it does not cause tripping hazards by minimizing the lengths of hoses between components.&nbsp; If lengths of hoses are longer than needed, it should be able to be coiled and put somewhere out of the way of normal foot traffic.&nbsp; Hoses shall be routed in a way that does not cause the hose to kink and reduce flowrate.</p>\n\n<p>If chiller system holds 55 gallons or more of fuel or oil or similar fluid, provide an environmental catch tank capable of holding at least 110% of the capacity of the fuel, oil and other fluids required to operate the rental unit.</p>\n\n<p>Unit must be affixed with a metal tag designating the supplying company, a POC responsible for repairs and maintenance, and a phone number for the POC who is responsible for repairs and maintenance.</p>\n\n<p>Contractor must provide instruction manual and training as requested.</p>\n\n<p>Contractor provided equipment (i.e. hoses, manifolds, etc.) shall have insulation installed around them to reduce temperature losses in the Chill Water System.</p>\n\n<p></p>\n\n<p>Interested vendors should notify contract speicialist of their interest</p>","origin":"detail"},"contacts":[{"name":"Gordon Weston","role":"primary","email":"gordon.t.weston3.civ@us.navy.mil","phone":"7573960964"},{"name":"Rebekah Riggins","role":"secondary","email":"rebekah.r.riggins.civ@us.navy.mil","phone":"7579674014"}],"place_of_performance":{"zip":"29445","state":{"code":"SC","name":"South Carolina"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"23709-1001","city":"PORTSMOUTH","state":"VA","country":"USA"},"naics_codes":["532490"],"award":null,"attachments":[],"awards":[],"related":[{"key":"N4215827QE016","latest_notice_id":"b4492ef2ab7c446c988244de75ad1322","title":"Filter Elements","solicitation_number":"N4215827QE016","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","naics":"333998","psc":"4330","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N4215827QE015","latest_notice_id":"791c40ed67ce44e0a92e17469b251263","title":"NNSY HOSE ASSEMBLY (AEROQUIP)","solicitation_number":"N4215827QE015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","naics":"326220","psc":"4720","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N4215827QE013","latest_notice_id":"422966a5481246f8862434961ad56289","title":"Signal Conditioner AA Lab Systems","solicitation_number":"N4215827QE013","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-30T14:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","naics":"334419","psc":"5999","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N4215827QE010","latest_notice_id":"ba36b75d969f4bee8017f1351bb3fc42","title":"Hose, Flexible","solicitation_number":"N4215827QE010","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","naics":"326220","psc":"4720","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N4215827QE008","latest_notice_id":"13ffdd0fb44e4987b10328ccd3703065","title":"Portable Liquid Nitrogen Circulation Heater","solicitation_number":"N4215827QE008","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N42158","office_name":"NORFOLK NAVAL SHIPYARD GF","naics":"333994","psc":"4520","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open":[{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"52000QR270001331","latest_notice_id":"d568fe51f8974fba897b5adfd95c15cf","title":"CGC FLORENCE FINCH Telescopic Handler Rental","solicitation_number":"52000QR270001331","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T19:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZU01","office_name":"CG-SEA-C21","naics":"532490","psc":"W039","set_aside":"SBA","state":"OR","county":"41007","county_name":"Clatsop County","city":"4103150","city_name":"Astoria","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA800326Q0012","latest_notice_id":"e7bfe00f055e411fbfb15097081f91e7","title":"FY27 Nursing Practice Oversight Course (NPOC)","solicitation_number":"FA800326Q0012","notice_type":"k","first_type":"k","first_posted":"2026-09-28","last_posted":"2026-11-24","notices":7,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8003","office_name":"FA8003 771 ENTERPRISE SOURCING SQ","naics":"532490","psc":"W099","set_aside":"SBA","state":"CO","county":"08041","county_name":"El Paso County","city":"0816000","city_name":"Colorado Springs","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":18,"indexable":false}