Solicitation, total small business set-aside
SMALL BUSINESS MULTIPLE AWARD CONSTRUCTION PROJECT- B2189 REPLACE ROOF AND HVAC SYSTEM
N4008023R0022009
Department of the Navy, Navfacsyscom Washington. Commercial and Institutional Building Construction.
Response deadline
June 17, 2025 at 2:00 AM EDT
Closed 527 days ago. Posted May 30, 2025. Scheduled to archive July 2, 2025.
Get the next one like this from Department of the Navy by email, the day it is posted.Find my opportunities
This one closed in 2025
193 like it are open now in commercial and institutional building construction
- NIH MULTIPLE-AWARD CONSTRUCTION CONTRACT (MACC) FOR GENERAL CONSTRUCTION SERVICES
National Institutes of Health, NIH a E Construction
SolicitationNAICS 236220Bethesda, MD75N99027R00002Closes in 19 daysDec 15 - 512A5-22-700 | EHRM Infra Upgrades | Perry Point, MD CO: Samantha Mihaila CS: Ric Sochor
Department of Veterans Affairs, Pcac
SolicitationSDVOSBNAICS 236220Maryland36C77626R0118Closes in 41 daysJan 6, 2027 - RFP - Maloney Canine Vet Clinic Addition
US Secret Service, U. S. Secret Service
SolicitationSmall businessNAICS 236220Laurel, MD70US0927R70094253Closes in 46 daysJan 11, 2027
All 193 open in commercial and institutional building construction
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates. Open Small business opportunities
- Time to respond
- Bidders had 18 days from the day the solicitation was posted, May 30, 2025, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
THIS SOLICITATION IS OPEN ***EXCLUSIVELY*** TO THE FOLLOWING SMALL BUSINESS MULTIPLE AWARD CONSTRUCTION CONTRACTORS:
C.E.R., Inc.
877 Baltimore Annapolis Blvd., Suite 101
Severna Park, Maryland 21146
CJW Contractors, Inc.
13849 Park Center Rd, Suite B
Herndon, Virginia, 20171
Edifice Services JV, LLC
507 N. Frederick Ave, Suite 104
Gaithersburg, Maryland 20877
ENCON Desbuild JV3 LLC
8201 Corporate Drive, Suite 720
Hyattsville, Maryland 20785
EVCON-CWC JV, LLC
3176 ½ Bladensburg Rd NE, Suite 1
Washington, District of Columbia 20018
Fastbreak General Contractors, LLC
47 W Queens Way Suite G1
Hampton, Virginia 23669
Ocean Construction Services
104 Aragona Blvd Suite 101
Virginia Beach, Virginia 23462
Ritz Construction
47 East All Saints Street, Suite 6
Frederick, Maryland 21701
This construction project involves the replacement of roofing and HVAC systems. The following summary outlines the key components of the scope of work.
Roof Replacement:
The Roof Project includes the Removal and Installation of a new approximately 33,800 SF modified bitumen roof excluding the roofs of the Security Station and associated covered walkway to the northwest.
The Roof Work shall include but is not limited to the removal of existing: modified bitumen roofing system, ridged insulation, expansion joints, pipe sleeves, flashing and counter flashings, reglets, water damaged wood decking, metal fascia, gutters, downspouts, roof drain covers, gutters, gutter downspouts and any other related items associated with roofing work. Existing roof ladders are to be removed and reinstalled in place. The access door at the north side of highest most roof it to be removed and a new appropriately sized door is to be installed, due to the increase in roof insulation the flashings and counter flashing may conflict with the height of the door. All operations equipment is to be removed and stored per Supported Command instruction prior to work beginning. The Contractor is to remove and replace approximately 30% of joists and roof deck that are damaged due to water intrusion. The Contractor is to remove and replace in kind 500 LF of wood fascia and vent soffit in locations of water damage.
Testing of the roof drains shall be tested after roof installation, any failed roof drains are the responsibility of the contractor. Contingent on the results of the test work shall be done to ensure proper drainage. Lead testing is required prior to the beginning of work.
Provide a new roof system complies with ICC code. Provide metal flashing, counter flashing, vent sleeves, stainless steel rain covers over pitch pockets, seal base of pitch pockets with elastomeric sealant, curbs for new HVAC units, metal roof drain strainers, crickets, coping (if required), metal fascia, gutters, downspouts, and expansion joints. Interior work shall include the repair of ceilings; repair any damaged ceiling finishes to match existing (30%). The existing wood deck and joists areas to be replaced where required.
HVAC Replacement:
The HVAC project includes but is not limited to demolition and installation of new HVAC system to include ductwork, piping, wiring, control devices, and all other appurtenances comprising a complete and operable system. Contractor shall verify location and dimensions of existing mechanical and electrical equipment, shall coordinate all work prior to the start of construction.
Contractor shall comply with federal, state, and local codes and laws involving abandonment and sealing of Geothermal HVAC system. The Geothermal Loop must be sealed by a Certified Master Well Driller. All fluid in the boreholes/tubing must be removed, includes sampling of the liquid to ensure it does not contain additives making it Hazardous Waste. If it is a Hazardous Waste, the liquid must properly dispose in methods in accordance with applicable federal, state, and local codes and laws. A Well abandonment form must be submitted to Maryland Department Environmental (MDE) after sealing. Provide copy of the form to contracting officer. See Attached form in part 6.
Contractor shall provide radon testing for 90 days for each habitable room after the project completion. Contractor shall comply with Radon Testing Standard Procedures in accordance with EPA and Navy Radon Assessment and Mitigation Program (NAVRAMP) Guidebook for Naval Shore Installations.
Contractor shall provide Structural Engineer to perform roof structural analyzes, load calculation, and solution to reinforce existing roof to support the new load of HVAC equipment.
Contractor shall carefully remove existing security cameras, audio notification devices, fire alarm and detectors to accommodate the work spaces. Shall be reinstalled at their original locations after the completion of work.
Contractor shall ensure proper handling, storage and proper disposal of all hazardous material, recovery and recycle HVAC system refrigerants, test downspouts and roof drainage are functioning properly after the project completion in accordance with NAS PAX River CATEX environmental requirements. See part 6 attachment.
Provide grass sod replacement damaged during construction.
Please see the solicitation and detailed scope of work attached to this post for additional information.
If you have any questions please don’t hesitate to contact me.
v/r
Jennifer Coffman
Contract Specialist
NAVFAC Washington
Cell Phone: (202) 436-1831
Fax: (301)-342-3141
jennifer.e.coffman2.civ@us.navy.mil
22445 Peary Rd Bldg. 504
Patuxent River, MD 20670
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- N4008023R0022 RFP X009.pdf573 KB, May 30, 2025
- Atch A B2189 Replace Roof_HVAC System Specs.pdf24.8 MB, May 30, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 30, 2025
Solicitation
Due June 17, 2025 at 2:00 AM EDT. SAM.gov, notice 8e818b9be1b146ff9c9aa174c7a8a008
1 revision on SAM
- May 30, 2025: publish, solicitation
Points of contact
- Jennifer Coffmanjennifer.e.coffman2.civ@us.navy.mil(202) 436-1831
- Barbara A Thompsonbarbara.a.thompson@navy.mil3017574918