{"canonical":"https://sealedbidder.com/opportunities/n0016426snb96","key":"N0016426SNB96","url":"https://sealedbidder.com/opportunities/n0016426snb96","title":"REGENERATIVE BATTERY CYCLER","solicitation_number":"N0016426SNB96","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-08T16:00:00Z","first_posted":"2026-07-23","last_posted":"2026-07-23","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NSWC CRANE","naics":"334515","psc":"6130","set_aside":null,"place_state":"IN","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"18101","place_county_name":"Martin County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"98bccec55b734202982d0ed7d11d6e9a","title":"REGENERATIVE BATTERY CYCLER","solicitation_number":"N0016426SNB96","notice_type":"s","base_type":"s","posted":"2026-07-23","posted_at":"2026-07-23T20:42:48.807Z","due_at":"2026-05-08T16:00:00Z","due_date":"2026-05-08","cancelled":false,"archived":true,"archive_date":"2026-05-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/98bccec55b734202982d0ed7d11d6e9a/view","enriched":true,"history":[{"index":3,"title":"REGENERATIVE BATTERY CYCLER","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-23T20:42:48.807Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"98bccec55b734202982d0ed7d11d6e9a","solicitation_number":"N0016426SNB96"}]}],"latest_notice_id":"98bccec55b734202982d0ed7d11d6e9a","first_type":"s","notices":[{"dates":{"posted":"2026-07-23","posted_at":"2026-07-23T20:42:48.807Z","created_at":"2026-07-23T20:40:59.948Z","modified_at":"2026-07-24T03:55:45.366Z","response_deadline":{"raw":"2026-05-08T12:00:00-04:00","utc":"2026-05-08T16:00:00Z","date":"2026-05-08","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/98bccec55b734202982d0ed7d11d6e9a/view"},"naics":{"codes":["334515"],"primary":"334515"},"title":"REGENERATIVE BATTERY CYCLER","agency":{"office":{"code":"N00164","name":"NSWC CRANE"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"47522-5001","city":"CRANE","state":"IN","country":"USA"},"organization_id":"100076494","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-23","archive_type":"auto15"},"history":[{"index":3,"title":"REGENERATIVE BATTERY CYCLER","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-23T20:42:48.807Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"98bccec55b734202982d0ed7d11d6e9a","solicitation_number":"N0016426SNB96"}],"contacts":[{"name":"Amy Haworth","role":"primary","email":"amy.haworth@navy.mil","phone":"8128545497"},{"name":"ANDREW FICKLIN","role":"secondary","email":"andrew.b.ficklin.civ@us.navy.mil","phone":"8123813258"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"98bccec55b734202982d0ed7d11d6e9a","lineage_id":"98bccec55b734202982d0ed7d11d6e9a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-28T02:03:29.168532615Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"6a0dfac38e6bc582552fc3d1907c847ae3deed17c16eafac1602c2568031c182","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-28T02:03:29.168532615Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>MARKET SURVEY - SOURCES SOUGHT SYNOPSIS: The Government is issuing this RFl/sources sought announcement as part of market survey to identify qualified sources capable of providing a regenerative battery cycler to replace NHR 9200 cyclers. This equipment will be utilized to test, cycle, and evaluate large-scale lead-acid battery systems to include VRLA chemistries. used in mission-critical facility backup and maritime applications.&nbsp; To enable seamless regenerative discharge and recharge cycles, the equipment must function as a bi-directional DC source and load.</p>\n\n<p></p>\n\n<p>The Contractor shall provide a turnkey testing system, including all necessary power hardware, control software, environmental sensor integration, and safety interlocks required to safely cycle high-capacity lead-acid battery banks.</p>\n\n<p>Interested sources must demonstrate the capability to provide a system that meets or exceeds the following specifications:</p>\n\n<p></p>\n\n<p>Electrical &amp; Performance Specifications</p>\n\n<p></p>\n\n<p>Parameter</p>\n\n<p>Required Specification</p>\n\n<p>Voltage Range</p>\n\n<p>1 - 40V</p>\n\n<p>Current Range</p>\n\n<p>0 - 3000A (Charge and Discharge)</p>\n\n<p>Power Range (Charge)</p>\n\n<p>0 - 40 kW</p>\n\n<p>Power Range (Discharge)</p>\n\n<p>0 - 60 kW</p>\n\n<p>Facility Input Power</p>\n\n<p>480 VAC, 3-Phase, 60 Hz, 80A</p>\n\n<p>Cooling</p>\n\n<p>Air Cooling is preferred</p>\n\n<p>Regenerative Power Efficiency</p>\n\n<p>Regenerative discharge capabilities of at least 90%</p>\n\n<p></p>\n\n<p>AC Ripple Limitation</p>\n\n<p>AC ripple voltage imposed on the DC bus must be less than 0.5% RMS of the float voltage</p>\n\n<p>Voltage Regulation Precision</p>\n\n<p>Maintain a steady-state DC output voltage regulation of +/- 0.5% (or tighter) across all operating ranges, independent of line voltage fluctuations or rapid load transitions.</p>\n\n<p></p>\n\n<p>Design &amp; Integration Capabilities</p>\n\n<p></p>\n\n<p>Feature</p>\n\n<p>Requirement</p>\n\n<p>System Architecture</p>\n\n<p>Bi-directional DC source/load and battery cycling equipment utilizing a modular design.</p>\n\n<p>Parallel Channel Scaling</p>\n\n<p>Capable of paralleling multiple channels to multiply the current capacity</p>\n\n<p>Control Modes</p>\n\n<p>System must support Constant Voltage (CV), Constant Current (CC), and Constant Power (CP) along with pulsing operational modes.</p>\n\n<p>Hardware Integration</p>\n\n<p>Must be fully compatible with National Instruments (NI) CompactRIO (cRIO) controllers and data acquisition (DAQ) systems.</p>\n\n<p>Software Integration</p>\n\n<p>Must be LabVIEW compatible and support standard integration utilizing Interchangeable Virtual Instrument (IVI) drivers.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>The system must incorporate multiple independent layers of hardware and software safety controls to protect personnel, facility infrastructure, and the Unit Under Test (UUT). The system must meet or exceed the following safety capabilities:</p>\n\n<p></p>\n\n<p>Safety Feature</p>\n\n<p>Requirement</p>\n\n<p>Physical Isolation</p>\n\n<p>Must feature internal, independent electromechanical safety contactors on the DC output channels.</p>\n\n<p>Hardware Interlocks</p>\n\n<p>Must include a dedicated, dual-channel external wired interlock loop for integration with thermal chambers or external safety gates, alongside a front-mounted physical Emergency Stop (E-Stop) Interlocks.</p>\n\n<p>UUT Protection Circuits</p>\n\n<p>Must feature integrated reverse-polarity checking and a soft-start pre-charge circuit to prevent in-rush current surges upon battery connection.</p>\n\n<p>Programmable Protection</p>\n\n<p>Software and firmware must allow users to define strict, fast-acting trip thresholds for Over-Voltage (OV), Under-Voltage (UV), Over-Current (OC), and Over-Power (OP).</p>\n\n<p>Communication Fail-Safe</p>\n\n<p>Must feature a programmable hardware watchdog timer that automatically shuts down the outputs and opens isolation contactors if communications with the master controller (e.g., cRIO) are interrupted.</p>\n\n<p></p>\n\n<p>Warranty and Maintenance:</p>\n\n<p></p>\n\n<p>Support Category</p>\n\n<p>Requirement</p>\n\n<p>Standard Warranty</p>\n\n<p>Provide details on the standard OEM warranty (minimum 12 months preferred), including coverage details (parts, labor, and travel) and return-to-factory vs. on-site repair terms.</p>\n\n<p>Preventive Maintenance</p>\n\n<p>Describe available preventive maintenance agreements (PMAs), including the recommended frequency of on-site inspections, fan/filter replacements, and thermal checks.</p>\n\n<p>Calibration Services</p>\n\n<p>Detail the requirements and procedures for system calibration. The system must be capable of being calibrated to ISO/IEC 17025:2017 standards. Specify if calibration can be performed on-site or if the unit must be returned to the manufacturer.</p>\n\n<p>Technical Support</p>\n\n<p>Provide information on available technical support structures, including guaranteed response times (e.g., 24/48-hour response), availability of remote diagnostics, and software update access.</p>\n\n<p></p>\n\n<p>The technical specifications listed represent the Government&#39;s target operational baseline. If interested sources cannot meet these exact thresholds (e.g., specific voltage, current, or power ranges), they are requested to submit their standard commercial capabilities, highlighting where their system deviates, and propose alternative configurations that could meet the overall mission objective of replacing the NHR 9200-60 with equivalent or upgraded equipment.</p>\n\n<p></p>\n\n<p></p>\n\n<p>Responses should include the following:</p>\n\n<p></p>\n\n<p>Include your companies technical and manufacturing capabilities and quality certifications held. Lastly, please provide a history of your company and past performance on Government contracts if any.</p>\n\n<p></p>\n\n<p>This submission may be in the form of product literature, operating instructions, and/or supplemental technical documentation that define the item(s) and associated hardware. Potential sources should provide any delivery, shipping or warranty information.</p>\n\n<p>Responses from Small and Small Disadvantaged Business firms are highly encouraged. Firms responding should indicate if they are a small business, a socially and economically disadvantaged business, 8(a) firms, historically black colleges or universities, and minority institutions.</p>\n\n<p>Responses to the RFI shall include the following:</p>\n\n<p>Submitter&#39;s Name</p>\n\n<p>Street Address, City, State, NINE-Digit zip code</p>\n\n<p>Point of Contact (POC)</p>\n\n<p>Cage Code</p>\n\n<p>Size and Socioeconomic Status</p>\n\n<p>POC Telephone and facsimile numbers</p>\n\n<p>Announcement Number: N0016426SNB96</p>\n\n<p></p>\n\n<p>Contractors must be properly registered in the Government System for Award Management database (SAM). Offerors may obtain information on SAM registration and annual confirmation requirements by calling 1-866-606-8220, or via the Internet at www.sam.gov.</p>\n\n<p>At the current time, NO FUNDING IS AVAILABLE for contractual efforts. This sources sought synopsis does not constitute an Invitation for Bids (IFB), a Request for Quote (RFQ), or a Request for Proposal (RFP) and it should not be construed as a commitment of any kind by the government to issue a formal solicitation or ultimately award a contract. The US Government is in no way liable to pay for or reimburse any companies or entities that respond to this announcement. Any costs incurred by interested companies in response to this announcement will NOT be reimbursed.</p>\n\n<p>Please refer to announcement number N0016426SNB96 in all correspondence and communications. E-mail point of contact for information regarding the subject RFI is Amy Haworth; amy.n.haworth.civ@us.navy.mil and Andrew Ficklin; andrew.b.ficklin.civ@us.navy.mil.</p>\n\n<p>All changes that occur will be posted to the beta.SAM.gov website.</p>","text":"MARKET SURVEY - SOURCES SOUGHT SYNOPSIS: The Government is issuing this RFl/sources sought announcement as part of market survey to identify qualified sources capable of providing a regenerative battery cycler to replace NHR 9200 cyclers. This equipment will be utilized to test, cycle, and evaluate large-scale lead-acid battery systems to include VRLA chemistries. used in mission-critical facility backup and maritime applications. To enable seamless regenerative discharge and recharge cycles, the equipment must function as a bi-directional DC source and load.\n\nThe Contractor shall provide a turnkey testing system, including all necessary power hardware, control software, environmental sensor integration, and safety interlocks required to safely cycle high-capacity lead-acid battery banks.\n\nInterested sources must demonstrate the capability to provide a system that meets or exceeds the following specifications:\n\nElectrical & Performance Specifications\n\nParameter\n\nRequired Specification\n\nVoltage Range\n\n1 - 40V\n\nCurrent Range\n\n0 - 3000A (Charge and Discharge)\n\nPower Range (Charge)\n\n0 - 40 kW\n\nPower Range (Discharge)\n\n0 - 60 kW\n\nFacility Input Power\n\n480 VAC, 3-Phase, 60 Hz, 80A\n\nCooling\n\nAir Cooling is preferred\n\nRegenerative Power Efficiency\n\nRegenerative discharge capabilities of at least 90%\n\nAC Ripple Limitation\n\nAC ripple voltage imposed on the DC bus must be less than 0.5% RMS of the float voltage\n\nVoltage Regulation Precision\n\nMaintain a steady-state DC output voltage regulation of +/- 0.5% (or tighter) across all operating ranges, independent of line voltage fluctuations or rapid load transitions.\n\nDesign & Integration Capabilities\n\nFeature\n\nRequirement\n\nSystem Architecture\n\nBi-directional DC source/load and battery cycling equipment utilizing a modular design.\n\nParallel Channel Scaling\n\nCapable of paralleling multiple channels to multiply the current capacity\n\nControl Modes\n\nSystem must support Constant Voltage (CV), Constant Current (CC), and Constant Power (CP) along with pulsing operational modes.\n\nHardware Integration\n\nMust be fully compatible with National Instruments (NI) CompactRIO (cRIO) controllers and data acquisition (DAQ) systems.\n\nSoftware Integration\n\nMust be LabVIEW compatible and support standard integration utilizing Interchangeable Virtual Instrument (IVI) drivers.\n\nThe system must incorporate multiple independent layers of hardware and software safety controls to protect personnel, facility infrastructure, and the Unit Under Test (UUT). The system must meet or exceed the following safety capabilities:\n\nSafety Feature\n\nRequirement\n\nPhysical Isolation\n\nMust feature internal, independent electromechanical safety contactors on the DC output channels.\n\nHardware Interlocks\n\nMust include a dedicated, dual-channel external wired interlock loop for integration with thermal chambers or external safety gates, alongside a front-mounted physical Emergency Stop (E-Stop) Interlocks.\n\nUUT Protection Circuits\n\nMust feature integrated reverse-polarity checking and a soft-start pre-charge circuit to prevent in-rush current surges upon battery connection.\n\nProgrammable Protection\n\nSoftware and firmware must allow users to define strict, fast-acting trip thresholds for Over-Voltage (OV), Under-Voltage (UV), Over-Current (OC), and Over-Power (OP).\n\nCommunication Fail-Safe\n\nMust feature a programmable hardware watchdog timer that automatically shuts down the outputs and opens isolation contactors if communications with the master controller (e.g., cRIO) are interrupted.\n\nWarranty and Maintenance:\n\nSupport Category\n\nRequirement\n\nStandard Warranty\n\nProvide details on the standard OEM warranty (minimum 12 months preferred), including coverage details (parts, labor, and travel) and return-to-factory vs. on-site repair terms.\n\nPreventive Maintenance\n\nDescribe available preventive maintenance agreements (PMAs), including the recommended frequency of on-site inspections, fan/filter replacements, and thermal checks.\n\nCalibration Services\n\nDetail the requirements and procedures for system calibration. The system must be capable of being calibrated to ISO/IEC 17025:2017 standards. Specify if calibration can be performed on-site or if the unit must be returned to the manufacturer.\n\nTechnical Support\n\nProvide information on available technical support structures, including guaranteed response times (e.g., 24/48-hour response), availability of remote diagnostics, and software update access.\n\nThe technical specifications listed represent the Government's target operational baseline. If interested sources cannot meet these exact thresholds (e.g., specific voltage, current, or power ranges), they are requested to submit their standard commercial capabilities, highlighting where their system deviates, and propose alternative configurations that could meet the overall mission objective of replacing the NHR 9200-60 with equivalent or upgraded equipment.\n\nResponses should include the following:\n\nInclude your companies technical and manufacturing capabilities and quality certifications held. Lastly, please provide a history of your company and past performance on Government contracts if any.\n\nThis submission may be in the form of product literature, operating instructions, and/or supplemental technical documentation that define the item(s) and associated hardware. Potential sources should provide any delivery, shipping or warranty information.\n\nResponses from Small and Small Disadvantaged Business firms are highly encouraged. Firms responding should indicate if they are a small business, a socially and economically disadvantaged business, 8(a) firms, historically black colleges or universities, and minority institutions.\n\nResponses to the RFI shall include the following:\n\nSubmitter's Name\n\nStreet Address, City, State, NINE-Digit zip code\n\nPoint of Contact (POC)\n\nCage Code\n\nSize and Socioeconomic Status\n\nPOC Telephone and facsimile numbers\n\nAnnouncement Number: N0016426SNB96\n\nContractors must be properly registered in the Government System for Award Management database (SAM). Offerors may obtain information on SAM registration and annual confirmation requirements by calling 1-866-606-8220, or via the Internet at www.sam.gov.\n\nAt the current time, NO FUNDING IS AVAILABLE for contractual efforts. This sources sought synopsis does not constitute an Invitation for Bids (IFB), a Request for Quote (RFQ), or a Request for Proposal (RFP) and it should not be construed as a commitment of any kind by the government to issue a formal solicitation or ultimately award a contract. The US Government is in no way liable to pay for or reimburse any companies or entities that respond to this announcement. Any costs incurred by interested companies in response to this announcement will NOT be reimbursed.\n\nPlease refer to announcement number N0016426SNB96 in all correspondence and communications. E-mail point of contact for information regarding the subject RFI is Amy Haworth; amy.n.haworth.civ@us.navy.mil and Andrew Ficklin; andrew.b.ficklin.civ@us.navy.mil.\n\nAll changes that occur will be posted to the beta.SAM.gov website.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"N0016426SNB96","place_of_performance":{"zip":"47522","state":{"code":"IN","name":"Indiana"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6130"}],"due_at":"2026-05-08T16:00:00Z","due_date":"2026-05-08","closes_at":"2026-05-08T16:00:00Z","awardable":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","state":"IN","county":"18101","county_name":"Martin County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-28T02:20:17.536431Z","principal_notice_id":"98bccec55b734202982d0ed7d11d6e9a","description":{"text":"MARKET SURVEY - SOURCES SOUGHT SYNOPSIS: The Government is issuing this RFl/sources sought announcement as part of market survey to identify qualified sources capable of providing a regenerative battery cycler to replace NHR 9200 cyclers. This equipment will be utilized to test, cycle, and evaluate large-scale lead-acid battery systems to include VRLA chemistries. used in mission-critical facility backup and maritime applications. To enable seamless regenerative discharge and recharge cycles, the equipment must function as a bi-directional DC source and load.\n\nThe Contractor shall provide a turnkey testing system, including all necessary power hardware, control software, environmental sensor integration, and safety interlocks required to safely cycle high-capacity lead-acid battery banks.\n\nInterested sources must demonstrate the capability to provide a system that meets or exceeds the following specifications:\n\nElectrical & Performance Specifications\n\nParameter\n\nRequired Specification\n\nVoltage Range\n\n1 - 40V\n\nCurrent Range\n\n0 - 3000A (Charge and Discharge)\n\nPower Range (Charge)\n\n0 - 40 kW\n\nPower Range (Discharge)\n\n0 - 60 kW\n\nFacility Input Power\n\n480 VAC, 3-Phase, 60 Hz, 80A\n\nCooling\n\nAir Cooling is preferred\n\nRegenerative Power Efficiency\n\nRegenerative discharge capabilities of at least 90%\n\nAC Ripple Limitation\n\nAC ripple voltage imposed on the DC bus must be less than 0.5% RMS of the float voltage\n\nVoltage Regulation Precision\n\nMaintain a steady-state DC output voltage regulation of +/- 0.5% (or tighter) across all operating ranges, independent of line voltage fluctuations or rapid load transitions.\n\nDesign & Integration Capabilities\n\nFeature\n\nRequirement\n\nSystem Architecture\n\nBi-directional DC source/load and battery cycling equipment utilizing a modular design.\n\nParallel Channel Scaling\n\nCapable of paralleling multiple channels to multiply the current capacity\n\nControl Modes\n\nSystem must support Constant Voltage (CV), Constant Current (CC), and Constant Power (CP) along with pulsing operational modes.\n\nHardware Integration\n\nMust be fully compatible with National Instruments (NI) CompactRIO (cRIO) controllers and data acquisition (DAQ) systems.\n\nSoftware Integration\n\nMust be LabVIEW compatible and support standard integration utilizing Interchangeable Virtual Instrument (IVI) drivers.\n\nThe system must incorporate multiple independent layers of hardware and software safety controls to protect personnel, facility infrastructure, and the Unit Under Test (UUT). The system must meet or exceed the following safety capabilities:\n\nSafety Feature\n\nRequirement\n\nPhysical Isolation\n\nMust feature internal, independent electromechanical safety contactors on the DC output channels.\n\nHardware Interlocks\n\nMust include a dedicated, dual-channel external wired interlock loop for integration with thermal chambers or external safety gates, alongside a front-mounted physical Emergency Stop (E-Stop) Interlocks.\n\nUUT Protection Circuits\n\nMust feature integrated reverse-polarity checking and a soft-start pre-charge circuit to prevent in-rush current surges upon battery connection.\n\nProgrammable Protection\n\nSoftware and firmware must allow users to define strict, fast-acting trip thresholds for Over-Voltage (OV), Under-Voltage (UV), Over-Current (OC), and Over-Power (OP).\n\nCommunication Fail-Safe\n\nMust feature a programmable hardware watchdog timer that automatically shuts down the outputs and opens isolation contactors if communications with the master controller (e.g., cRIO) are interrupted.\n\nWarranty and Maintenance:\n\nSupport Category\n\nRequirement\n\nStandard Warranty\n\nProvide details on the standard OEM warranty (minimum 12 months preferred), including coverage details (parts, labor, and travel) and return-to-factory vs. on-site repair terms.\n\nPreventive Maintenance\n\nDescribe available preventive maintenance agreements (PMAs), including the recommended frequency of on-site inspections, fan/filter replacements, and thermal checks.\n\nCalibration Services\n\nDetail the requirements and procedures for system calibration. The system must be capable of being calibrated to ISO/IEC 17025:2017 standards. Specify if calibration can be performed on-site or if the unit must be returned to the manufacturer.\n\nTechnical Support\n\nProvide information on available technical support structures, including guaranteed response times (e.g., 24/48-hour response), availability of remote diagnostics, and software update access.\n\nThe technical specifications listed represent the Government's target operational baseline. If interested sources cannot meet these exact thresholds (e.g., specific voltage, current, or power ranges), they are requested to submit their standard commercial capabilities, highlighting where their system deviates, and propose alternative configurations that could meet the overall mission objective of replacing the NHR 9200-60 with equivalent or upgraded equipment.\n\nResponses should include the following:\n\nInclude your companies technical and manufacturing capabilities and quality certifications held. Lastly, please provide a history of your company and past performance on Government contracts if any.\n\nThis submission may be in the form of product literature, operating instructions, and/or supplemental technical documentation that define the item(s) and associated hardware. Potential sources should provide any delivery, shipping or warranty information.\n\nResponses from Small and Small Disadvantaged Business firms are highly encouraged. Firms responding should indicate if they are a small business, a socially and economically disadvantaged business, 8(a) firms, historically black colleges or universities, and minority institutions.\n\nResponses to the RFI shall include the following:\n\nSubmitter's Name\n\nStreet Address, City, State, NINE-Digit zip code\n\nPoint of Contact (POC)\n\nCage Code\n\nSize and Socioeconomic Status\n\nPOC Telephone and facsimile numbers\n\nAnnouncement Number: N0016426SNB96\n\nContractors must be properly registered in the Government System for Award Management database (SAM). Offerors may obtain information on SAM registration and annual confirmation requirements by calling 1-866-606-8220, or via the Internet at www.sam.gov.\n\nAt the current time, NO FUNDING IS AVAILABLE for contractual efforts. This sources sought synopsis does not constitute an Invitation for Bids (IFB), a Request for Quote (RFQ), or a Request for Proposal (RFP) and it should not be construed as a commitment of any kind by the government to issue a formal solicitation or ultimately award a contract. The US Government is in no way liable to pay for or reimburse any companies or entities that respond to this announcement. Any costs incurred by interested companies in response to this announcement will NOT be reimbursed.\n\nPlease refer to announcement number N0016426SNB96 in all correspondence and communications. E-mail point of contact for information regarding the subject RFI is Amy Haworth; amy.n.haworth.civ@us.navy.mil and Andrew Ficklin; andrew.b.ficklin.civ@us.navy.mil.\n\nAll changes that occur will be posted to the beta.SAM.gov website.","html":"<p>MARKET SURVEY - SOURCES SOUGHT SYNOPSIS: The Government is issuing this RFl/sources sought announcement as part of market survey to identify qualified sources capable of providing a regenerative battery cycler to replace NHR 9200 cyclers. This equipment will be utilized to test, cycle, and evaluate large-scale lead-acid battery systems to include VRLA chemistries. used in mission-critical facility backup and maritime applications.&nbsp; To enable seamless regenerative discharge and recharge cycles, the equipment must function as a bi-directional DC source and load.</p>\n\n<p></p>\n\n<p>The Contractor shall provide a turnkey testing system, including all necessary power hardware, control software, environmental sensor integration, and safety interlocks required to safely cycle high-capacity lead-acid battery banks.</p>\n\n<p>Interested sources must demonstrate the capability to provide a system that meets or exceeds the following specifications:</p>\n\n<p></p>\n\n<p>Electrical &amp; Performance Specifications</p>\n\n<p></p>\n\n<p>Parameter</p>\n\n<p>Required Specification</p>\n\n<p>Voltage Range</p>\n\n<p>1 - 40V</p>\n\n<p>Current Range</p>\n\n<p>0 - 3000A (Charge and Discharge)</p>\n\n<p>Power Range (Charge)</p>\n\n<p>0 - 40 kW</p>\n\n<p>Power Range (Discharge)</p>\n\n<p>0 - 60 kW</p>\n\n<p>Facility Input Power</p>\n\n<p>480 VAC, 3-Phase, 60 Hz, 80A</p>\n\n<p>Cooling</p>\n\n<p>Air Cooling is preferred</p>\n\n<p>Regenerative Power Efficiency</p>\n\n<p>Regenerative discharge capabilities of at least 90%</p>\n\n<p></p>\n\n<p>AC Ripple Limitation</p>\n\n<p>AC ripple voltage imposed on the DC bus must be less than 0.5% RMS of the float voltage</p>\n\n<p>Voltage Regulation Precision</p>\n\n<p>Maintain a steady-state DC output voltage regulation of +/- 0.5% (or tighter) across all operating ranges, independent of line voltage fluctuations or rapid load transitions.</p>\n\n<p></p>\n\n<p>Design &amp; Integration Capabilities</p>\n\n<p></p>\n\n<p>Feature</p>\n\n<p>Requirement</p>\n\n<p>System Architecture</p>\n\n<p>Bi-directional DC source/load and battery cycling equipment utilizing a modular design.</p>\n\n<p>Parallel Channel Scaling</p>\n\n<p>Capable of paralleling multiple channels to multiply the current capacity</p>\n\n<p>Control Modes</p>\n\n<p>System must support Constant Voltage (CV), Constant Current (CC), and Constant Power (CP) along with pulsing operational modes.</p>\n\n<p>Hardware Integration</p>\n\n<p>Must be fully compatible with National Instruments (NI) CompactRIO (cRIO) controllers and data acquisition (DAQ) systems.</p>\n\n<p>Software Integration</p>\n\n<p>Must be LabVIEW compatible and support standard integration utilizing Interchangeable Virtual Instrument (IVI) drivers.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>The system must incorporate multiple independent layers of hardware and software safety controls to protect personnel, facility infrastructure, and the Unit Under Test (UUT). The system must meet or exceed the following safety capabilities:</p>\n\n<p></p>\n\n<p>Safety Feature</p>\n\n<p>Requirement</p>\n\n<p>Physical Isolation</p>\n\n<p>Must feature internal, independent electromechanical safety contactors on the DC output channels.</p>\n\n<p>Hardware Interlocks</p>\n\n<p>Must include a dedicated, dual-channel external wired interlock loop for integration with thermal chambers or external safety gates, alongside a front-mounted physical Emergency Stop (E-Stop) Interlocks.</p>\n\n<p>UUT Protection Circuits</p>\n\n<p>Must feature integrated reverse-polarity checking and a soft-start pre-charge circuit to prevent in-rush current surges upon battery connection.</p>\n\n<p>Programmable Protection</p>\n\n<p>Software and firmware must allow users to define strict, fast-acting trip thresholds for Over-Voltage (OV), Under-Voltage (UV), Over-Current (OC), and Over-Power (OP).</p>\n\n<p>Communication Fail-Safe</p>\n\n<p>Must feature a programmable hardware watchdog timer that automatically shuts down the outputs and opens isolation contactors if communications with the master controller (e.g., cRIO) are interrupted.</p>\n\n<p></p>\n\n<p>Warranty and Maintenance:</p>\n\n<p></p>\n\n<p>Support Category</p>\n\n<p>Requirement</p>\n\n<p>Standard Warranty</p>\n\n<p>Provide details on the standard OEM warranty (minimum 12 months preferred), including coverage details (parts, labor, and travel) and return-to-factory vs. on-site repair terms.</p>\n\n<p>Preventive Maintenance</p>\n\n<p>Describe available preventive maintenance agreements (PMAs), including the recommended frequency of on-site inspections, fan/filter replacements, and thermal checks.</p>\n\n<p>Calibration Services</p>\n\n<p>Detail the requirements and procedures for system calibration. The system must be capable of being calibrated to ISO/IEC 17025:2017 standards. Specify if calibration can be performed on-site or if the unit must be returned to the manufacturer.</p>\n\n<p>Technical Support</p>\n\n<p>Provide information on available technical support structures, including guaranteed response times (e.g., 24/48-hour response), availability of remote diagnostics, and software update access.</p>\n\n<p></p>\n\n<p>The technical specifications listed represent the Government&#39;s target operational baseline. If interested sources cannot meet these exact thresholds (e.g., specific voltage, current, or power ranges), they are requested to submit their standard commercial capabilities, highlighting where their system deviates, and propose alternative configurations that could meet the overall mission objective of replacing the NHR 9200-60 with equivalent or upgraded equipment.</p>\n\n<p></p>\n\n<p></p>\n\n<p>Responses should include the following:</p>\n\n<p></p>\n\n<p>Include your companies technical and manufacturing capabilities and quality certifications held. Lastly, please provide a history of your company and past performance on Government contracts if any.</p>\n\n<p></p>\n\n<p>This submission may be in the form of product literature, operating instructions, and/or supplemental technical documentation that define the item(s) and associated hardware. Potential sources should provide any delivery, shipping or warranty information.</p>\n\n<p>Responses from Small and Small Disadvantaged Business firms are highly encouraged. Firms responding should indicate if they are a small business, a socially and economically disadvantaged business, 8(a) firms, historically black colleges or universities, and minority institutions.</p>\n\n<p>Responses to the RFI shall include the following:</p>\n\n<p>Submitter&#39;s Name</p>\n\n<p>Street Address, City, State, NINE-Digit zip code</p>\n\n<p>Point of Contact (POC)</p>\n\n<p>Cage Code</p>\n\n<p>Size and Socioeconomic Status</p>\n\n<p>POC Telephone and facsimile numbers</p>\n\n<p>Announcement Number: N0016426SNB96</p>\n\n<p></p>\n\n<p>Contractors must be properly registered in the Government System for Award Management database (SAM). Offerors may obtain information on SAM registration and annual confirmation requirements by calling 1-866-606-8220, or via the Internet at www.sam.gov.</p>\n\n<p>At the current time, NO FUNDING IS AVAILABLE for contractual efforts. This sources sought synopsis does not constitute an Invitation for Bids (IFB), a Request for Quote (RFQ), or a Request for Proposal (RFP) and it should not be construed as a commitment of any kind by the government to issue a formal solicitation or ultimately award a contract. The US Government is in no way liable to pay for or reimburse any companies or entities that respond to this announcement. Any costs incurred by interested companies in response to this announcement will NOT be reimbursed.</p>\n\n<p>Please refer to announcement number N0016426SNB96 in all correspondence and communications. E-mail point of contact for information regarding the subject RFI is Amy Haworth; amy.n.haworth.civ@us.navy.mil and Andrew Ficklin; andrew.b.ficklin.civ@us.navy.mil.</p>\n\n<p>All changes that occur will be posted to the beta.SAM.gov website.</p>","origin":"detail"},"contacts":[{"name":"Amy Haworth","role":"primary","email":"amy.haworth@navy.mil","phone":"8128545497"},{"name":"ANDREW FICKLIN","role":"secondary","email":"andrew.b.ficklin.civ@us.navy.mil","phone":"8123813258"}],"place_of_performance":{"zip":"47522","state":{"code":"IN","name":"Indiana"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"47522-5001","city":"CRANE","state":"IN","country":"USA"},"naics_codes":["334515"],"award":null,"attachments":[],"awards":[],"related":[{"key":"N0016427Q0027","latest_notice_id":"6f7b6af625774a53ac5c83392b8fb4ab","title":"EMCOR RACK SYSTEMS","solicitation_number":"N0016427Q0027","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"332439","psc":"5340","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"N0016427Q0029","latest_notice_id":"4800873b96c04d359470308f9eacba15","title":"19020-NEW/CHROMA MULTI-CHANNEL HIPOT TESTER","solicitation_number":"N0016427Q0029","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334513","psc":"6625","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0016427Q0015","latest_notice_id":"bc650f6eae154e1bac9e1d00f5828913","title":"SOLE SOURCE- DELAY LINE MODULE","solicitation_number":"N0016427Q0015","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334515","psc":"6625","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N0016427Q0033","latest_notice_id":"8c4c0bfff1654385b8566176c54b991e","title":"Printed Circuit Board (PCB)","solicitation_number":"N0016427Q0033","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334419","psc":"5963","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N0016427Q0020","latest_notice_id":"d980841723b2491fb885b4fa3e749de6","title":"SINGLE COLORED DIODE PUMP LASER TEST TEARDOWN EVALUATION AND REPAIR","solicitation_number":"N0016427Q0020","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"811310","psc":"J066","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"N0016427Q0015","latest_notice_id":"bc650f6eae154e1bac9e1d00f5828913","title":"SOLE SOURCE- DELAY LINE MODULE","solicitation_number":"N0016427Q0015","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334515","psc":"6625","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N6833526RFPREQBL310000026","latest_notice_id":"238ef98fbffe40dcb3f4c0cecc2f707e","title":"Request for Information Authorized Distributors/Resellers of Keysight Technologies Products","solicitation_number":"N68335-26-RFPREQ-BL31000-0026","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-26T22:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N68335","office_name":"NAVAIR WARFARE CTR AIRCRAFT DIV","naics":"334515","psc":"6625","set_aside":null,"state":"MS","county":"28047","county_name":"Harrison County","city":"2829700","city_name":"Gulfport","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-11T05:50:21.226923Z"},{"key":"N0010426QNF12","latest_notice_id":"6983ef64eae84b6789638a6497ae12c9","title":"SERVER,AUTOMATIC DA","solicitation_number":"N0010426QNF12","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-10-21","notices":3,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"334515","psc":"7E20","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7E20)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"}],"similar_open_total":40,"indexable":false}