{"canonical":"https://sealedbidder.com/opportunities/n0016425snb91","key":"N0016425SNB91","url":"https://sealedbidder.com/opportunities/n0016425snb91","title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","solicitation_number":"N0016425SNB91","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-18T19:00:00Z","first_posted":"2025-09-04","last_posted":"2025-09-10","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NSWC CRANE","naics":"339115","psc":"5855","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 5855)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"8d5d23c5ef604b9d8aa723ad783c93d0","title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","solicitation_number":"N0016425SNB91","notice_type":"s","base_type":"s","posted":"2025-09-04","posted_at":"2025-09-04T20:24:46.466Z","due_at":"2025-09-18T19:00:00Z","due_date":"2025-09-18","cancelled":false,"archived":true,"archive_date":"2025-10-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8d5d23c5ef604b9d8aa723ad783c93d0/view","enriched":true,"history":[{"index":3,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-10T15:37:44.246Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7aa2637965d04d83929075e937674c44","solicitation_number":"N0016425SNB91","parent_opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0"},{"index":1,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-04T20:24:46.466Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0","solicitation_number":"N0016425SNB91"}]},{"notice_id":"7aa2637965d04d83929075e937674c44","title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","solicitation_number":"N0016425SNB91","notice_type":"s","base_type":"s","posted":"2025-09-10","posted_at":"2025-09-10T15:37:44.246Z","due_at":"2025-09-18T19:00:00Z","due_date":"2025-09-18","cancelled":false,"archived":true,"archive_date":"2025-10-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7aa2637965d04d83929075e937674c44/view","enriched":true,"history":[{"index":3,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-10T15:37:44.246Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7aa2637965d04d83929075e937674c44","solicitation_number":"N0016425SNB91","parent_opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0"},{"index":1,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-04T20:24:46.466Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0","solicitation_number":"N0016425SNB91"}]}],"latest_notice_id":"7aa2637965d04d83929075e937674c44","first_type":"s","notices":[{"dates":{"posted":"2025-09-04","posted_at":"2025-09-04T20:24:46.466Z","created_at":"2025-09-04T18:53:42.194Z","modified_at":"2025-10-04T04:00:10.197Z","response_deadline":{"raw":"2025-09-18T15:00:00-04:00","utc":"2025-09-18T19:00:00Z","date":"2025-09-18","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8d5d23c5ef604b9d8aa723ad783c93d0/view"},"naics":{"codes":["339115"],"primary":"339115"},"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","agency":{"office":{"code":"N00164","name":"NSWC CRANE"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"47522-5001","city":"CRANE","state":"IN","country":"USA"},"organization_id":"100076494","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-03","archive_type":"auto15"},"history":[{"index":3,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-10T15:37:44.246Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7aa2637965d04d83929075e937674c44","solicitation_number":"N0016425SNB91","parent_opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0"},{"index":1,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-04T20:24:46.466Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0","solicitation_number":"N0016425SNB91"}],"contacts":[{"name":"Nathaniel Chesterson","role":"primary","email":"Nathaniel.p.chesterson.civ@us.navy.mil"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"8d5d23c5ef604b9d8aa723ad783c93d0","lineage_id":"8d5d23c5ef604b9d8aa723ad783c93d0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-01T02:11:05.749255681Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"3b69ef06d6f611892f67f6de2f6a6d6edc11dcb503b0436fc662883b9d1c129a","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-01T02:11:05.749255681Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>Request for information (RFI)</strong></p>\n\n<p><strong>For</strong></p>\n\n<p><strong>Elecro-Optic/Infrared systems in the commercial industry</strong></p>\n\n<p><strong>N0016425SNB91</strong></p>\n\n<p>THIS IS A REQUEST FOR INFORMATION (RFI) FOR MARKET RESEARCH PURPOSES ONLY.&nbsp; This is a RFI and not a formal solicitation.&nbsp; If the requirements are sought, a formal solicitation will be announced separately at a later time.&nbsp; Information provided to the Government as a result of this posting is strictly voluntary and given with no expectation of compensation, and clearly provided at no cost to the Government.&nbsp;The Naval Surface Warfare Center Crane Division (NSWC-CR) is seeking information on EO/IR systems in the commercial industry, to provide recommendations for a system to be installed on a new platform. The system will consist of a Wide Field of View (WFOV) subsystem and a Narrow Field of View (NFOV) subsystem. NSWC-CR would like feedback on the following performance characteristics.</p>\n\n<p><em>WFOV Subsystem</em></p>\n\n<ol>\n\t<li>System(s) capable of detection and tracking of the below contacts with associated range performance</li>\n</ol>\n\n<p>Contact Type &nbsp; &nbsp; &nbsp; &nbsp; Min Range &nbsp; &nbsp; &nbsp; &nbsp; Max Range&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Conditions </p>\n\n<p>Small Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; High Visibility (HV) Day, HV Night</p>\n\n<p>Small Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Degraded Visibility (DV) Day, DV Night</p>\n\n<p>Medium Vessel&nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 9.2 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night</p>\n\n<p>Medium Vessel&nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Large Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 11 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night</p>\n\n<p>Large Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Small Buoy&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; HV Day, HV Night</p>\n\n<p>Small Buoy&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Medium Buoy &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night </p>\n\n<p>Medium Buoy &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4.8 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DV Day, DV Night </p>\n\n<p>Large Buoy &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 6.5 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night </p>\n\n<p>Large Buoy &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4.8 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DV Day, DV Night </p>\n\n<p>Person in the Water &nbsp; 0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;  0.9 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; HV Day, HV Night </p>\n\n<p>Person in the Water&nbsp;  0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.4 km DV&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Day, DV Night </p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 2. System(s) with unobstructed 360&deg; azimuthal coverage.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 3. +/-45&deg; redundant coverage relative to the ship&rsquo;s centerline.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 4. System(s) with an unobstructed elevation coverage from 10&deg; relative below the horizon to 10&deg; relative above the horizon.</p>\n\n<p><em>NFOV Subsystem</em></p>\n\n<ol>\n\t<li>System(s) capable of cued detection, tracking, laser range finding, and EO/IR imagery for object classification and identification.\n\t<ul>\n\t\t<li>Automatic Classification at 100 to 5600 meters.</li>\n\t\t<li>Automatic Identification at 100 to 4800 meters.</li>\n\t</ul>\n\t</li>\n\t<li>System(s) with unobstructed 360&deg; azimuthal coverage.</li>\n\t<li>+/- 45&deg; redundant coverage relative to the ship&rsquo;s centerline.</li>\n\t<li>System(s) with an unobstructed elevation coverage from 15&deg; relative below the horizon to 35&deg; relative above the horizon.</li>\n</ol>\n\n<p><em>Other Requirements</em></p>\n\n<ol>\n\t<li>IP level of at least IP66.</li>\n\t<li>An operational temperature range of -9 to 49 &deg;C.</li>\n\t<li>Update rate of &ge;0.5Hz</li>\n</ol>\n\n<p>Please respond if you meet the above. Responses are also encouraged to provide feedback and any potentially unduly restrictive desired characteristics.</p>\n\n<p>Responses are preferred to be prepared so that when printed, they meet the following requirements: 8.5x11 inch paper, single-spaced typed lines, 1 inch margins, 12 point Times New Roman font.&nbsp; Tables may use 10-point font. &nbsp;Respondents are responsible for ensuring the legibility of all table, charts, etc., and should assume that when their response is printed or copied, it will be done in black and white.&nbsp; Respond with the following information/documentation:</p>\n\n<ol>\n\t<li>Technical literature/data with complete description and specifications illustrating the ability of the apparatus to meet the above characteristics in the request for information.</li>\n\t<li>Company Name and/or affiliate information, including parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime).</li>\n\t<li>Size of business and type of business (i.e. large, 8(a), Women-Owned, Hub-Zone, Veteran owned, Service Disabled Veteran Owned Business).</li>\n\t<li>A list of customers for current, relevant work performed for government or non-government entities showing past performance.</li>\n\t<li>Two points of contact including name, title, phone, fax, e-mail address and CAGE Code, and UEI number.</li>\n</ol>\n\n<p>Only manufacturers, prime contractors and authorized distributors should respond.</p>\n\n<p>Direct expression of interested as well as required documentation should be submitted to NWSC-CR, JXQY using reference number N0016425SNB91 sent via email to Nathaniel Chesterson via email at Nathaniel.p.chesterson.civ@us.navy.mil no later than 3:00 pm EST on 18 SEP 2025.&nbsp;</p>\n\n<p>This Request for Information is for information and planning purposes only and shall not be construed as a commitment by the Government.&nbsp; The Government will make NO reimbursement for any costs associated with providing information in response to this announcement, or any follow-up information requests. If a formal solicitation is issued, the Government reserves the right to consider any type of socio-economic set-aside.</p>","text":"Request for information (RFI)\n\nFor\n\nElecro-Optic/Infrared systems in the commercial industry\n\nN0016425SNB91\n\nTHIS IS A REQUEST FOR INFORMATION (RFI) FOR MARKET RESEARCH PURPOSES ONLY. This is a RFI and not a formal solicitation. If the requirements are sought, a formal solicitation will be announced separately at a later time. Information provided to the Government as a result of this posting is strictly voluntary and given with no expectation of compensation, and clearly provided at no cost to the Government. The Naval Surface Warfare Center Crane Division (NSWC-CR) is seeking information on EO/IR systems in the commercial industry, to provide recommendations for a system to be installed on a new platform. The system will consist of a Wide Field of View (WFOV) subsystem and a Narrow Field of View (NFOV) subsystem. NSWC-CR would like feedback on the following performance characteristics.\n\nWFOV Subsystem\n\n• System(s) capable of detection and tracking of the below contacts with associated range performance\n\nContact Type  Min Range  Max Range Conditions\n\nSmall Vessel 0.1 km 5.5 km High Visibility (HV) Day, HV Night\n\nSmall Vessel 0.1 km 4.8 km Degraded Visibility (DV) Day, DV Night\n\nMedium Vessel 0.1 km 9.2 km HV Day, HV Night\n\nMedium Vessel 0.1 km 5.5 km DV Day, DV Night\n\nLarge Vessel 0.1 km 11 km HV Day, HV Night\n\nLarge Vessel 0.1 km 5.5 km DV Day, DV Night\n\nSmall Buoy 0.1 km 4.8 km HV Day, HV Night\n\nSmall Buoy 0.1 km 3.8 km DV Day, DV Night\n\nMedium Buoy  0.1 km  5.5 km  HV Day, HV Night\n\nMedium Buoy  0.1 km  4.8 km  DV Day, DV Night\n\nLarge Buoy  0.1 km  6.5 km  HV Day, HV Night\n\nLarge Buoy  0.1 km  4.8 km  DV Day, DV Night\n\nPerson in the Water  0.1 km  0.9 km  HV Day, HV Night\n\nPerson in the Water  0.1 km  0.4 km DV Day, DV Night\n\n2. System(s) with unobstructed 360° azimuthal coverage.\n\n3. +/-45° redundant coverage relative to the ship’s centerline.\n\n4. System(s) with an unobstructed elevation coverage from 10° relative below the horizon to 10° relative above the horizon.\n\nNFOV Subsystem\n\n• System(s) capable of cued detection, tracking, laser range finding, and EO/IR imagery for object classification and identification.\n\n• Automatic Classification at 100 to 5600 meters.\n\n• Automatic Identification at 100 to 4800 meters.\n\n• System(s) with unobstructed 360° azimuthal coverage.\n\n• +/- 45° redundant coverage relative to the ship’s centerline.\n\n• System(s) with an unobstructed elevation coverage from 15° relative below the horizon to 35° relative above the horizon.\n\nOther Requirements\n\n• IP level of at least IP66.\n\n• An operational temperature range of -9 to 49 °C.\n\n• Update rate of ≥0.5Hz\n\nPlease respond if you meet the above. Responses are also encouraged to provide feedback and any potentially unduly restrictive desired characteristics.\n\nResponses are preferred to be prepared so that when printed, they meet the following requirements: 8.5x11 inch paper, single-spaced typed lines, 1 inch margins, 12 point Times New Roman font. Tables may use 10-point font. Respondents are responsible for ensuring the legibility of all table, charts, etc., and should assume that when their response is printed or copied, it will be done in black and white. Respond with the following information/documentation:\n\n• Technical literature/data with complete description and specifications illustrating the ability of the apparatus to meet the above characteristics in the request for information.\n\n• Company Name and/or affiliate information, including parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime).\n\n• Size of business and type of business (i.e. large, 8(a), Women-Owned, Hub-Zone, Veteran owned, Service Disabled Veteran Owned Business).\n\n• A list of customers for current, relevant work performed for government or non-government entities showing past performance.\n\n• Two points of contact including name, title, phone, fax, e-mail address and CAGE Code, and UEI number.\n\nOnly manufacturers, prime contractors and authorized distributors should respond.\n\nDirect expression of interested as well as required documentation should be submitted to NWSC-CR, JXQY using reference number N0016425SNB91 sent via email to Nathaniel Chesterson via email at Nathaniel.p.chesterson.civ@us.navy.mil no later than 3:00 pm EST on 18 SEP 2025.\n\nThis Request for Information is for information and planning purposes only and shall not be construed as a commitment by the Government. The Government will make NO reimbursement for any costs associated with providing information in response to this announcement, or any follow-up information requests. If a formal solicitation is issued, the Government reserves the right to consider any type of socio-economic set-aside.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"N0016425SNB91","product_service_code":"5855"},{"dates":{"posted":"2025-09-10","posted_at":"2025-09-10T15:37:44.246Z","created_at":"2025-09-10T15:02:09.338Z","modified_at":"2025-10-04T04:00:10.197Z","response_deadline":{"raw":"2025-09-18T15:00:00-04:00","utc":"2025-09-18T19:00:00Z","date":"2025-09-18","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7aa2637965d04d83929075e937674c44/view"},"naics":{"codes":["339115"],"primary":"339115"},"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","agency":{"office":{"code":"N00164","name":"NSWC CRANE"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"47522-5001","city":"CRANE","state":"IN","country":"USA"},"organization_id":"100076494","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-03","archive_type":"auto15"},"history":[{"index":3,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-10T15:37:44.246Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7aa2637965d04d83929075e937674c44","solicitation_number":"N0016425SNB91","parent_opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0"},{"index":1,"title":"Request for information (RFI) For Elecro-Optic/Infrared systems in the commercial industry","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-04T20:24:46.466Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8d5d23c5ef604b9d8aa723ad783c93d0","solicitation_number":"N0016425SNB91"}],"contacts":[{"name":"Nathaniel Chesterson","role":"primary","email":"Nathaniel.p.chesterson.civ@us.navy.mil"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"7aa2637965d04d83929075e937674c44","lineage_id":"8d5d23c5ef604b9d8aa723ad783c93d0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-31T01:52:31.020372829Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"1d9a7c69504b7ba4da54a62d957a7d7f8cef60c0ad0c3d7d034d23edf4439b7c","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-31T01:52:31.020372829Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>AMENDMENT 0001:</strong></p>\n\n<p>The purpose of this amendment is to add an attachment.</p>\n\n<p><u><strong>ORIGINAL POSTING:</strong></u></p>\n\n<p><strong>Request for information (RFI)</strong></p>\n\n<p><strong>For</strong></p>\n\n<p><strong>Elecro-Optic/Infrared systems in the commercial industry</strong></p>\n\n<p><strong>N0016425SNB91</strong></p>\n\n<p>THIS IS A REQUEST FOR INFORMATION (RFI) FOR MARKET RESEARCH PURPOSES ONLY.&nbsp; This is a RFI and not a formal solicitation.&nbsp; If the requirements are sought, a formal solicitation will be announced separately at a later time.&nbsp; Information provided to the Government as a result of this posting is strictly voluntary and given with no expectation of compensation, and clearly provided at no cost to the Government.&nbsp;The Naval Surface Warfare Center Crane Division (NSWC-CR) is seeking information on EO/IR systems in the commercial industry, to provide recommendations for a system to be installed on a new platform. The system will consist of a Wide Field of View (WFOV) subsystem and a Narrow Field of View (NFOV) subsystem. NSWC-CR would like feedback on the following performance characteristics.</p>\n\n<p><em>WFOV Subsystem</em></p>\n\n<ol>\n\t<li>System(s) capable of detection and tracking of the below contacts with associated range performance</li>\n</ol>\n\n<p>Contact Type &nbsp; &nbsp; &nbsp; &nbsp; Min Range &nbsp; &nbsp; &nbsp; &nbsp; Max Range&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Conditions </p>\n\n<p>Small Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; High Visibility (HV) Day, HV Night</p>\n\n<p>Small Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Degraded Visibility (DV) Day, DV Night</p>\n\n<p>Medium Vessel&nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 9.2 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night</p>\n\n<p>Medium Vessel&nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Large Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 11 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night</p>\n\n<p>Large Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Small Buoy&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; HV Day, HV Night</p>\n\n<p>Small Buoy&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Medium Buoy &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night </p>\n\n<p>Medium Buoy &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4.8 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DV Day, DV Night </p>\n\n<p>Large Buoy &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 6.5 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night </p>\n\n<p>Large Buoy &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4.8 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DV Day, DV Night </p>\n\n<p>Person in the Water &nbsp; 0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;  0.9 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; HV Day, HV Night </p>\n\n<p>Person in the Water&nbsp;  0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.4 km DV&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Day, DV Night </p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 2. System(s) with unobstructed 360&deg; azimuthal coverage.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 3. +/-45&deg; redundant coverage relative to the ship&rsquo;s centerline.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 4. System(s) with an unobstructed elevation coverage from 10&deg; relative below the horizon to 10&deg; relative above the horizon.</p>\n\n<p><em>NFOV Subsystem</em></p>\n\n<ol>\n\t<li>System(s) capable of cued detection, tracking, laser range finding, and EO/IR imagery for object classification and identification.\n\t<ul>\n\t\t<li>Automatic Classification at 100 to 5600 meters.</li>\n\t\t<li>Automatic Identification at 100 to 4800 meters.</li>\n\t</ul>\n\t</li>\n\t<li>System(s) with unobstructed 360&deg; azimuthal coverage.</li>\n\t<li>+/- 45&deg; redundant coverage relative to the ship&rsquo;s centerline.</li>\n\t<li>System(s) with an unobstructed elevation coverage from 15&deg; relative below the horizon to 35&deg; relative above the horizon.</li>\n</ol>\n\n<p><em>Other Requirements</em></p>\n\n<ol>\n\t<li>IP level of at least IP66.</li>\n\t<li>An operational temperature range of -9 to 49 &deg;C.</li>\n\t<li>Update rate of &ge;0.5Hz</li>\n</ol>\n\n<p>Please respond if you meet the above. Responses are also encouraged to provide feedback and any potentially unduly restrictive desired characteristics.</p>\n\n<p>Responses are preferred to be prepared so that when printed, they meet the following requirements: 8.5x11 inch paper, single-spaced typed lines, 1 inch margins, 12 point Times New Roman font.&nbsp; Tables may use 10-point font. &nbsp;Respondents are responsible for ensuring the legibility of all table, charts, etc., and should assume that when their response is printed or copied, it will be done in black and white.&nbsp; Respond with the following information/documentation:</p>\n\n<ol>\n\t<li>Technical literature/data with complete description and specifications illustrating the ability of the apparatus to meet the above characteristics in the request for information.</li>\n\t<li>Company Name and/or affiliate information, including parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime).</li>\n\t<li>Size of business and type of business (i.e. large, 8(a), Women-Owned, Hub-Zone, Veteran owned, Service Disabled Veteran Owned Business).</li>\n\t<li>A list of customers for current, relevant work performed for government or non-government entities showing past performance.</li>\n\t<li>Two points of contact including name, title, phone, fax, e-mail address and CAGE Code, and UEI number.</li>\n</ol>\n\n<p>Only manufacturers, prime contractors and authorized distributors should respond.</p>\n\n<p>Direct expression of interested as well as required documentation should be submitted to NWSC-CR, JXQY using reference number N0016425SNB91 sent via email to Nathaniel Chesterson via email at Nathaniel.p.chesterson.civ@us.navy.mil no later than 3:00 pm EST on 18 SEP 2025.&nbsp;</p>\n\n<p>This Request for Information is for information and planning purposes only and shall not be construed as a commitment by the Government.&nbsp; The Government will make NO reimbursement for any costs associated with providing information in response to this announcement, or any follow-up information requests. If a formal solicitation is issued, the Government reserves the right to consider any type of socio-economic set-aside.</p>","text":"AMENDMENT 0001:\n\nThe purpose of this amendment is to add an attachment.\n\nORIGINAL POSTING:\n\nRequest for information (RFI)\n\nFor\n\nElecro-Optic/Infrared systems in the commercial industry\n\nN0016425SNB91\n\nTHIS IS A REQUEST FOR INFORMATION (RFI) FOR MARKET RESEARCH PURPOSES ONLY. This is a RFI and not a formal solicitation. If the requirements are sought, a formal solicitation will be announced separately at a later time. Information provided to the Government as a result of this posting is strictly voluntary and given with no expectation of compensation, and clearly provided at no cost to the Government. The Naval Surface Warfare Center Crane Division (NSWC-CR) is seeking information on EO/IR systems in the commercial industry, to provide recommendations for a system to be installed on a new platform. The system will consist of a Wide Field of View (WFOV) subsystem and a Narrow Field of View (NFOV) subsystem. NSWC-CR would like feedback on the following performance characteristics.\n\nWFOV Subsystem\n\n• System(s) capable of detection and tracking of the below contacts with associated range performance\n\nContact Type  Min Range  Max Range Conditions\n\nSmall Vessel 0.1 km 5.5 km High Visibility (HV) Day, HV Night\n\nSmall Vessel 0.1 km 4.8 km Degraded Visibility (DV) Day, DV Night\n\nMedium Vessel 0.1 km 9.2 km HV Day, HV Night\n\nMedium Vessel 0.1 km 5.5 km DV Day, DV Night\n\nLarge Vessel 0.1 km 11 km HV Day, HV Night\n\nLarge Vessel 0.1 km 5.5 km DV Day, DV Night\n\nSmall Buoy 0.1 km 4.8 km HV Day, HV Night\n\nSmall Buoy 0.1 km 3.8 km DV Day, DV Night\n\nMedium Buoy  0.1 km  5.5 km  HV Day, HV Night\n\nMedium Buoy  0.1 km  4.8 km  DV Day, DV Night\n\nLarge Buoy  0.1 km  6.5 km  HV Day, HV Night\n\nLarge Buoy  0.1 km  4.8 km  DV Day, DV Night\n\nPerson in the Water  0.1 km  0.9 km  HV Day, HV Night\n\nPerson in the Water  0.1 km  0.4 km DV Day, DV Night\n\n2. System(s) with unobstructed 360° azimuthal coverage.\n\n3. +/-45° redundant coverage relative to the ship’s centerline.\n\n4. System(s) with an unobstructed elevation coverage from 10° relative below the horizon to 10° relative above the horizon.\n\nNFOV Subsystem\n\n• System(s) capable of cued detection, tracking, laser range finding, and EO/IR imagery for object classification and identification.\n\n• Automatic Classification at 100 to 5600 meters.\n\n• Automatic Identification at 100 to 4800 meters.\n\n• System(s) with unobstructed 360° azimuthal coverage.\n\n• +/- 45° redundant coverage relative to the ship’s centerline.\n\n• System(s) with an unobstructed elevation coverage from 15° relative below the horizon to 35° relative above the horizon.\n\nOther Requirements\n\n• IP level of at least IP66.\n\n• An operational temperature range of -9 to 49 °C.\n\n• Update rate of ≥0.5Hz\n\nPlease respond if you meet the above. Responses are also encouraged to provide feedback and any potentially unduly restrictive desired characteristics.\n\nResponses are preferred to be prepared so that when printed, they meet the following requirements: 8.5x11 inch paper, single-spaced typed lines, 1 inch margins, 12 point Times New Roman font. Tables may use 10-point font. Respondents are responsible for ensuring the legibility of all table, charts, etc., and should assume that when their response is printed or copied, it will be done in black and white. Respond with the following information/documentation:\n\n• Technical literature/data with complete description and specifications illustrating the ability of the apparatus to meet the above characteristics in the request for information.\n\n• Company Name and/or affiliate information, including parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime).\n\n• Size of business and type of business (i.e. large, 8(a), Women-Owned, Hub-Zone, Veteran owned, Service Disabled Veteran Owned Business).\n\n• A list of customers for current, relevant work performed for government or non-government entities showing past performance.\n\n• Two points of contact including name, title, phone, fax, e-mail address and CAGE Code, and UEI number.\n\nOnly manufacturers, prime contractors and authorized distributors should respond.\n\nDirect expression of interested as well as required documentation should be submitted to NWSC-CR, JXQY using reference number N0016425SNB91 sent via email to Nathaniel Chesterson via email at Nathaniel.p.chesterson.civ@us.navy.mil no later than 3:00 pm EST on 18 SEP 2025.\n\nThis Request for Information is for information and planning purposes only and shall not be construed as a commitment by the Government. The Government will make NO reimbursement for any costs associated with providing information in response to this announcement, or any follow-up information requests. If a formal solicitation is issued, the Government reserves the right to consider any type of socio-economic set-aside.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"N0016425SNB91","product_service_code":"5855"}],"due_at":"2025-09-18T19:00:00Z","due_date":"2025-09-18","closes_at":"2025-09-18T19:00:00Z","awardable":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 5855)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-31T02:10:06.057010Z","principal_notice_id":"7aa2637965d04d83929075e937674c44","description":{"text":"AMENDMENT 0001:\n\nThe purpose of this amendment is to add an attachment.\n\nORIGINAL POSTING:\n\nRequest for information (RFI)\n\nFor\n\nElecro-Optic/Infrared systems in the commercial industry\n\nN0016425SNB91\n\nTHIS IS A REQUEST FOR INFORMATION (RFI) FOR MARKET RESEARCH PURPOSES ONLY. This is a RFI and not a formal solicitation. If the requirements are sought, a formal solicitation will be announced separately at a later time. Information provided to the Government as a result of this posting is strictly voluntary and given with no expectation of compensation, and clearly provided at no cost to the Government. The Naval Surface Warfare Center Crane Division (NSWC-CR) is seeking information on EO/IR systems in the commercial industry, to provide recommendations for a system to be installed on a new platform. The system will consist of a Wide Field of View (WFOV) subsystem and a Narrow Field of View (NFOV) subsystem. NSWC-CR would like feedback on the following performance characteristics.\n\nWFOV Subsystem\n\n• System(s) capable of detection and tracking of the below contacts with associated range performance\n\nContact Type  Min Range  Max Range Conditions\n\nSmall Vessel 0.1 km 5.5 km High Visibility (HV) Day, HV Night\n\nSmall Vessel 0.1 km 4.8 km Degraded Visibility (DV) Day, DV Night\n\nMedium Vessel 0.1 km 9.2 km HV Day, HV Night\n\nMedium Vessel 0.1 km 5.5 km DV Day, DV Night\n\nLarge Vessel 0.1 km 11 km HV Day, HV Night\n\nLarge Vessel 0.1 km 5.5 km DV Day, DV Night\n\nSmall Buoy 0.1 km 4.8 km HV Day, HV Night\n\nSmall Buoy 0.1 km 3.8 km DV Day, DV Night\n\nMedium Buoy  0.1 km  5.5 km  HV Day, HV Night\n\nMedium Buoy  0.1 km  4.8 km  DV Day, DV Night\n\nLarge Buoy  0.1 km  6.5 km  HV Day, HV Night\n\nLarge Buoy  0.1 km  4.8 km  DV Day, DV Night\n\nPerson in the Water  0.1 km  0.9 km  HV Day, HV Night\n\nPerson in the Water  0.1 km  0.4 km DV Day, DV Night\n\n2. System(s) with unobstructed 360° azimuthal coverage.\n\n3. +/-45° redundant coverage relative to the ship’s centerline.\n\n4. System(s) with an unobstructed elevation coverage from 10° relative below the horizon to 10° relative above the horizon.\n\nNFOV Subsystem\n\n• System(s) capable of cued detection, tracking, laser range finding, and EO/IR imagery for object classification and identification.\n\n• Automatic Classification at 100 to 5600 meters.\n\n• Automatic Identification at 100 to 4800 meters.\n\n• System(s) with unobstructed 360° azimuthal coverage.\n\n• +/- 45° redundant coverage relative to the ship’s centerline.\n\n• System(s) with an unobstructed elevation coverage from 15° relative below the horizon to 35° relative above the horizon.\n\nOther Requirements\n\n• IP level of at least IP66.\n\n• An operational temperature range of -9 to 49 °C.\n\n• Update rate of ≥0.5Hz\n\nPlease respond if you meet the above. Responses are also encouraged to provide feedback and any potentially unduly restrictive desired characteristics.\n\nResponses are preferred to be prepared so that when printed, they meet the following requirements: 8.5x11 inch paper, single-spaced typed lines, 1 inch margins, 12 point Times New Roman font. Tables may use 10-point font. Respondents are responsible for ensuring the legibility of all table, charts, etc., and should assume that when their response is printed or copied, it will be done in black and white. Respond with the following information/documentation:\n\n• Technical literature/data with complete description and specifications illustrating the ability of the apparatus to meet the above characteristics in the request for information.\n\n• Company Name and/or affiliate information, including parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime).\n\n• Size of business and type of business (i.e. large, 8(a), Women-Owned, Hub-Zone, Veteran owned, Service Disabled Veteran Owned Business).\n\n• A list of customers for current, relevant work performed for government or non-government entities showing past performance.\n\n• Two points of contact including name, title, phone, fax, e-mail address and CAGE Code, and UEI number.\n\nOnly manufacturers, prime contractors and authorized distributors should respond.\n\nDirect expression of interested as well as required documentation should be submitted to NWSC-CR, JXQY using reference number N0016425SNB91 sent via email to Nathaniel Chesterson via email at Nathaniel.p.chesterson.civ@us.navy.mil no later than 3:00 pm EST on 18 SEP 2025.\n\nThis Request for Information is for information and planning purposes only and shall not be construed as a commitment by the Government. The Government will make NO reimbursement for any costs associated with providing information in response to this announcement, or any follow-up information requests. If a formal solicitation is issued, the Government reserves the right to consider any type of socio-economic set-aside.","html":"<p><strong>AMENDMENT 0001:</strong></p>\n\n<p>The purpose of this amendment is to add an attachment.</p>\n\n<p><u><strong>ORIGINAL POSTING:</strong></u></p>\n\n<p><strong>Request for information (RFI)</strong></p>\n\n<p><strong>For</strong></p>\n\n<p><strong>Elecro-Optic/Infrared systems in the commercial industry</strong></p>\n\n<p><strong>N0016425SNB91</strong></p>\n\n<p>THIS IS A REQUEST FOR INFORMATION (RFI) FOR MARKET RESEARCH PURPOSES ONLY.&nbsp; This is a RFI and not a formal solicitation.&nbsp; If the requirements are sought, a formal solicitation will be announced separately at a later time.&nbsp; Information provided to the Government as a result of this posting is strictly voluntary and given with no expectation of compensation, and clearly provided at no cost to the Government.&nbsp;The Naval Surface Warfare Center Crane Division (NSWC-CR) is seeking information on EO/IR systems in the commercial industry, to provide recommendations for a system to be installed on a new platform. The system will consist of a Wide Field of View (WFOV) subsystem and a Narrow Field of View (NFOV) subsystem. NSWC-CR would like feedback on the following performance characteristics.</p>\n\n<p><em>WFOV Subsystem</em></p>\n\n<ol>\n\t<li>System(s) capable of detection and tracking of the below contacts with associated range performance</li>\n</ol>\n\n<p>Contact Type &nbsp; &nbsp; &nbsp; &nbsp; Min Range &nbsp; &nbsp; &nbsp; &nbsp; Max Range&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Conditions </p>\n\n<p>Small Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; High Visibility (HV) Day, HV Night</p>\n\n<p>Small Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Degraded Visibility (DV) Day, DV Night</p>\n\n<p>Medium Vessel&nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 9.2 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night</p>\n\n<p>Medium Vessel&nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Large Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 11 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night</p>\n\n<p>Large Vessel&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;5.5 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Small Buoy&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; HV Day, HV Night</p>\n\n<p>Small Buoy&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3.8 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; DV Day, DV Night</p>\n\n<p>Medium Buoy &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 5.5 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night </p>\n\n<p>Medium Buoy &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4.8 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DV Day, DV Night </p>\n\n<p>Large Buoy &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 6.5 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;HV Day, HV Night </p>\n\n<p>Large Buoy &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4.8 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DV Day, DV Night </p>\n\n<p>Person in the Water &nbsp; 0.1 km&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;  0.9 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; HV Day, HV Night </p>\n\n<p>Person in the Water&nbsp;  0.1 km &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.4 km DV&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Day, DV Night </p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 2. System(s) with unobstructed 360&deg; azimuthal coverage.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 3. +/-45&deg; redundant coverage relative to the ship&rsquo;s centerline.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; 4. System(s) with an unobstructed elevation coverage from 10&deg; relative below the horizon to 10&deg; relative above the horizon.</p>\n\n<p><em>NFOV Subsystem</em></p>\n\n<ol>\n\t<li>System(s) capable of cued detection, tracking, laser range finding, and EO/IR imagery for object classification and identification.\n\t<ul>\n\t\t<li>Automatic Classification at 100 to 5600 meters.</li>\n\t\t<li>Automatic Identification at 100 to 4800 meters.</li>\n\t</ul>\n\t</li>\n\t<li>System(s) with unobstructed 360&deg; azimuthal coverage.</li>\n\t<li>+/- 45&deg; redundant coverage relative to the ship&rsquo;s centerline.</li>\n\t<li>System(s) with an unobstructed elevation coverage from 15&deg; relative below the horizon to 35&deg; relative above the horizon.</li>\n</ol>\n\n<p><em>Other Requirements</em></p>\n\n<ol>\n\t<li>IP level of at least IP66.</li>\n\t<li>An operational temperature range of -9 to 49 &deg;C.</li>\n\t<li>Update rate of &ge;0.5Hz</li>\n</ol>\n\n<p>Please respond if you meet the above. Responses are also encouraged to provide feedback and any potentially unduly restrictive desired characteristics.</p>\n\n<p>Responses are preferred to be prepared so that when printed, they meet the following requirements: 8.5x11 inch paper, single-spaced typed lines, 1 inch margins, 12 point Times New Roman font.&nbsp; Tables may use 10-point font. &nbsp;Respondents are responsible for ensuring the legibility of all table, charts, etc., and should assume that when their response is printed or copied, it will be done in black and white.&nbsp; Respond with the following information/documentation:</p>\n\n<ol>\n\t<li>Technical literature/data with complete description and specifications illustrating the ability of the apparatus to meet the above characteristics in the request for information.</li>\n\t<li>Company Name and/or affiliate information, including parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime).</li>\n\t<li>Size of business and type of business (i.e. large, 8(a), Women-Owned, Hub-Zone, Veteran owned, Service Disabled Veteran Owned Business).</li>\n\t<li>A list of customers for current, relevant work performed for government or non-government entities showing past performance.</li>\n\t<li>Two points of contact including name, title, phone, fax, e-mail address and CAGE Code, and UEI number.</li>\n</ol>\n\n<p>Only manufacturers, prime contractors and authorized distributors should respond.</p>\n\n<p>Direct expression of interested as well as required documentation should be submitted to NWSC-CR, JXQY using reference number N0016425SNB91 sent via email to Nathaniel Chesterson via email at Nathaniel.p.chesterson.civ@us.navy.mil no later than 3:00 pm EST on 18 SEP 2025.&nbsp;</p>\n\n<p>This Request for Information is for information and planning purposes only and shall not be construed as a commitment by the Government.&nbsp; The Government will make NO reimbursement for any costs associated with providing information in response to this announcement, or any follow-up information requests. If a formal solicitation is issued, the Government reserves the right to consider any type of socio-economic set-aside.</p>","origin":"detail"},"contacts":[{"name":"Nathaniel Chesterson","role":"primary","email":"Nathaniel.p.chesterson.civ@us.navy.mil"}],"place_of_performance":null,"office_address":{"zip":"47522-5001","city":"CRANE","state":"IN","country":"USA"},"naics_codes":["339115"],"award":null,"attachments":[{"resource_id":"b87341296d3a4680b835590c545f531a","name":"25SNB91_SPECNOTE_0001_ATT1.docx","kind":"file","mime_type":".docx","size_bytes":13403,"posted_at":"2025-09-10T15:37:44.246Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b87341296d3a4680b835590c545f531a/download","mirrored":false}],"awards":[],"related":[{"key":"N0016427Q0014","latest_notice_id":"cbeccf2c409f4c48aedff76a3b4a4359","title":"ARBITRARY WAVEFORM GENERATOR","solicitation_number":"N0016427Q0014","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334516","psc":"6115","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"N0016426RGW20","latest_notice_id":"93e9c07a41614d00bb0dfa24604e466f","title":"N0016426RGW20-PROCUREMENT OF DESIGN AND PRODUCTION OF FLAT RAILCARS-PSC 2220- NAICS 336510","solicitation_number":"N0016426RGW20","notice_type":"o","first_type":"o","first_posted":"2026-01-21","last_posted":"2026-11-16","notices":13,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"336510","psc":"2220","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 2220)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"N0016427Q0027","latest_notice_id":"6f7b6af625774a53ac5c83392b8fb4ab","title":"EMCOR RACK SYSTEMS","solicitation_number":"N0016427Q0027","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"332439","psc":"5340","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"N0016427Q0029","latest_notice_id":"4800873b96c04d359470308f9eacba15","title":"19020-NEW/CHROMA MULTI-CHANNEL HIPOT TESTER","solicitation_number":"N0016427Q0029","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334513","psc":"6625","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0016427Q0015","latest_notice_id":"bc650f6eae154e1bac9e1d00f5828913","title":"SOLE SOURCE- DELAY LINE MODULE","solicitation_number":"N0016427Q0015","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334515","psc":"6625","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"IHS1511834","latest_notice_id":"559b1d390dfc49219e971609697c3bef","title":"All in one visual acuity system","solicitation_number":"IHS1511834","notice_type":"p","first_type":"p","first_posted":"2025-04-21","last_posted":"2025-04-21","notices":1,"due_at":"2029-04-29T12:00:00Z","due_date":"2029-04-29","closes_at":"2029-04-29T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H710","office_name":"NAVAJO AREA INDIAN HEALTH SVC","naics":"339115","psc":"6540","set_aside":"ISBEE","state":"NM","county":"35031","county_name":"McKinley County","city":"3518940","city_name":"Crownpoint","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open_total":1,"indexable":false}