{"canonical":"https://sealedbidder.com/opportunities/n0003326pr02399","key":"N0003326PR02399","url":"https://sealedbidder.com/opportunities/n0003326pr02399","title":"Bio-Medical Equipment Maintenance for USNS Comfort","solicitation_number":"N0003326PR02399","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-07T18:00:00Z","first_posted":"2026-06-26","last_posted":"2026-06-26","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"DEPT OF THE NAVY","naics":"621511","psc":"J065","set_aside":"SBA","place_state":"VA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"c685e5955ab34c9cb49f1dd320a4be7b","title":"Bio-Medical Equipment Maintenance for USNS Comfort","solicitation_number":"N0003326PR02399","notice_type":"s","base_type":"s","posted":"2026-06-26","posted_at":"2026-06-26T15:34:10.690Z","due_at":"2026-07-07T18:00:00Z","due_date":"2026-07-07","cancelled":false,"archived":true,"archive_date":"2026-07-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c685e5955ab34c9cb49f1dd320a4be7b/view","enriched":true,"history":[{"index":3,"title":"Bio-Medical Equipment Maintenance for USNS Comfort","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-26T15:34:10.690Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"c685e5955ab34c9cb49f1dd320a4be7b","solicitation_number":"N0003326PR02399"}]}],"latest_notice_id":"c685e5955ab34c9cb49f1dd320a4be7b","first_type":"s","notices":[{"dates":{"posted":"2026-06-26","posted_at":"2026-06-26T15:34:10.690Z","created_at":"2026-06-26T15:23:25.875Z","modified_at":"2026-07-23T03:55:45.027Z","response_deadline":{"raw":"2026-07-07T14:00:00-04:00","utc":"2026-07-07T18:00:00Z","date":"2026-07-07","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c685e5955ab34c9cb49f1dd320a4be7b/view"},"naics":{"codes":["621511"],"primary":"621511"},"title":"Bio-Medical Equipment Maintenance for USNS Comfort","agency":{"office":{"name":"DEPT OF THE NAVY"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"organization_id":"300000188","organization_type":"AGENCY"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-22","archive_type":"auto15"},"history":[{"index":3,"title":"Bio-Medical Equipment Maintenance for USNS Comfort","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-26T15:34:10.690Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"c685e5955ab34c9cb49f1dd320a4be7b","solicitation_number":"N0003326PR02399"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"c685e5955ab34c9cb49f1dd320a4be7b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"c685e5955ab34c9cb49f1dd320a4be7b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-01T00:55:02.991592317Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"cd8de62b8f173f25dee3ce77a6af35e5491fd9272ba5d465d0e16ed1b6c83085","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-01T00:55:02.991592317Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Pre-Solicitation Notice</p>\n\n<p>Notice of Intent to Sole Source</p>\n\n<p>USNS Comfort T-AH 20 requires calibration services for its 90 Biomedical Test, Measurement, and Diagnostic Equipment (TMDE) to maintain operational readiness and ensure patient safety. Without these services, the equipment will not be certified, resulting in a break in service and a failure to meet healthcare standards. Furthermore, medical equipment that does not have a concurrent service history is deemed unsafe, not recommended for patient use and will affect mission readiness plus operational capabilities.</p>\n\n<p><strong>Need:</strong></p>\n\n<p>USNS COMFORT T-AH 20 is responsible for Naval worldwide medical response during combat operation and or humanitarian relief for allied Nations. The vessel is equipped with over 2,600 pieces of medical equipment to constantly provide high level medical care at its 1,000-patient capacity. This medical equipment is required to have semiannual or annual calibration and examination using unit and manufacture specific Biomedical Test, Measurement, and Diagnostic Equipment&rsquo;s (TMDE). This TMDE is required to ensure patient safety, maintain mission readiness, and uphold operational standards.&nbsp; The equipment is regularly serviced, and periodic recertification is required to ensure that every tool remains accurate and fully functional for its users. Southeastern Biomedical Associates (incumbent) had provided all the required services for this requirement to include calibration services, shipping, and travel. Our Market research revealed that Southeastern Biomedical Associates is the only company capable of meeting the requirement.</p>\n\n<p>Without periodic recertification, there is a significant risk of equipment failure, false data, or rapid wear-and-tear that could compromise medical operations. Keeping these tools properly maintained avoids treatment errors, ensure units are always ready for deployment, and extend the lifespan of the equipment to reduce long-term costs.</p>\n\n<p>The Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1(Equipment List) &ndash; USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.</p>\n\n<p>NOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.</p>\n\n<p>The USNS Comfort is a ready-5 status ship, so it is critical to have Bio Med equipment up and run according to manufacturer&rsquo;s OEM.</p>\n\n<p>USNS Comfort (T-AH 20) 90 Biomedical Test Equipment items identified below:</p>\n\n<p>ITEM</p>\n\n<p>ECN</p>\n\n<p>NOMENCLATURE</p>\n\n<p>MANUFACTURER</p>\n\n<p>MODEL NAME</p>\n\n<p>MFR. S/N</p>\n\n<p>001</p>\n\n<p>5135</p>\n\n<p>PHOTOTACHOMETER</p>\n\n<p>AMETEK TCI</p>\n\n<p>1726</p>\n\n<p>32594144</p>\n\n<p>002</p>\n\n<p>5485</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>99B</p>\n\n<p>DM6820583</p>\n\n<p>003</p>\n\n<p>60245</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>99B</p>\n\n<p>DM7310704</p>\n\n<p>004</p>\n\n<p>60248</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>99B</p>\n\n<p>DM7310706</p>\n\n<p>005</p>\n\n<p>60638</p>\n\n<p>TESTER, IMPLANTABLE CARDIAC PACEMAKER</p>\n\n<p>BIO TEK INSTRUMENTS INC</p>\n\n<p>PMA-1</p>\n\n<p>2184</p>\n\n<p>006</p>\n\n<p>70180</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>DYNATECH NEVADA</p>\n\n<p>207B</p>\n\n<p>3294</p>\n\n<p>007</p>\n\n<p>70242</p>\n\n<p>SAMPLER, ENVIRONMENTAL, AIR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>INCU</p>\n\n<p>6050303</p>\n\n<p>008</p>\n\n<p>92022</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SIMS LEVEL 1 INC</p>\n\n<p>HLTA-40</p>\n\n<p>1999 0162</p>\n\n<p>009</p>\n\n<p>92023</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SIMS LEVEL 1 INC</p>\n\n<p>HLTA-40</p>\n\n<p>2002 0102</p>\n\n<p>010</p>\n\n<p>92054</p>\n\n<p>TESTER, DEFIBRILLATOR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>QED 6</p>\n\n<p>9122026</p>\n\n<p>011</p>\n\n<p>92055</p>\n\n<p>TESTER, DEFIBRILLATOR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>QED 6</p>\n\n<p>9122024</p>\n\n<p>012</p>\n\n<p>92327</p>\n\n<p>METER, WATT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>UW4</p>\n\n<p>9069005</p>\n\n<p>013</p>\n\n<p>92353</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM4-1G</p>\n\n<p>50057</p>\n\n<p>014</p>\n\n<p>92354</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM4-1G</p>\n\n<p>50070</p>\n\n<p>015</p>\n\n<p>92355</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM4-1G</p>\n\n<p>50056</p>\n\n<p>016</p>\n\n<p>92450</p>\n\n<p>FLOWMETER, GAS</p>\n\n<p>FLUKE BIOMEDICAL RADIATION MANAGEMENT</p>\n\n<p>VT MOBILE</p>\n\n<p>9777010</p>\n\n<p>017</p>\n\n<p>92796</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87V</p>\n\n<p>92070276</p>\n\n<p>018</p>\n\n<p>92877</p>\n\n<p>PHOTOTACHOMETER</p>\n\n<p>ELECTROMATIC EQUIPMENT CO. INC</p>\n\n<p>DT-205L</p>\n\n<p>C086B0087</p>\n\n<p>019</p>\n\n<p>92880</p>\n\n<p>TESTER, VENTILATOR</p>\n\n<p>MALLINCKRODT INC</p>\n\n<p>PTS 2000</p>\n\n<p>4150823002</p>\n\n<p>020</p>\n\n<p>93357</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4071</p>\n\n<p>021</p>\n\n<p>93358</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4069</p>\n\n<p>022</p>\n\n<p>93359</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4068</p>\n\n<p>023</p>\n\n<p>93360</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4072</p>\n\n<p>024</p>\n\n<p>93361</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4066</p>\n\n<p>025</p>\n\n<p>93362</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4070</p>\n\n<p>026</p>\n\n<p>94026</p>\n\n<p>RADIOMETER, LASER</p>\n\n<p>OPHIR OPTRONICS INC</p>\n\n<p>NOVA</p>\n\n<p>610308</p>\n\n<p>027</p>\n\n<p>N/A</p>\n\n<p>LASER POWER SENSOR</p>\n\n<p>OPHIR OPTRONICS INC</p>\n\n<p>30 (150)A-HE-SH-17, ROH</p>\n\n<p>585851</p>\n\n<p>028</p>\n\n<p>94186</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>9802051</p>\n\n<p>029</p>\n\n<p>94187</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>9802007</p>\n\n<p>030</p>\n\n<p>94286</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SMITHS MEDICAL ASD INC</p>\n\n<p>HLTA-40</p>\n\n<p>S112A00093</p>\n\n<p>031</p>\n\n<p>95381</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SMITHS MEDICAL</p>\n\n<p>DSTA-40</p>\n\n<p>S111A00867</p>\n\n<p>032</p>\n\n<p>95563</p>\n\n<p>SAMPLER, ENVIRONMENTAL, AIR, GAS/VAPOR</p>\n\n<p>RIKEN KEIKI CO LTD</p>\n\n<p>FI-21</p>\n\n<p>469010011ES</p>\n\n<p>033</p>\n\n<p>95905</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>33080280</p>\n\n<p>034</p>\n\n<p>95906</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670345</p>\n\n<p>035</p>\n\n<p>95907</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670346</p>\n\n<p>036</p>\n\n<p>95908</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670331</p>\n\n<p>037</p>\n\n<p>95910</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670348</p>\n\n<p>038</p>\n\n<p>95911</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680159</p>\n\n<p>039</p>\n\n<p>95912</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680155</p>\n\n<p>040</p>\n\n<p>95913</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680160</p>\n\n<p>041</p>\n\n<p>95914</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680162</p>\n\n<p>042</p>\n\n<p>95915</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680161</p>\n\n<p>043</p>\n\n<p>95916</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>33080281</p>\n\n<p>044</p>\n\n<p>95968</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PROSIM 8</p>\n\n<p>3396033</p>\n\n<p>045</p>\n\n<p>95969</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PROSIM 8</p>\n\n<p>3399037</p>\n\n<p>046</p>\n\n<p>95992</p>\n\n<p>TESTER, DEFIBRILLATOR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>IMPULSE 7000DP</p>\n\n<p>340109</p>\n\n<p>047</p>\n\n<p>95996</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA615</p>\n\n<p>3401026</p>\n\n<p>048</p>\n\n<p>95997</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA615</p>\n\n<p>3400035</p>\n\n<p>049</p>\n\n<p>96023</p>\n\n<p>TESTER, VENTILATOR</p>\n\n<p>COVIDIEN NELLCOR/PURITAN BENNETT</p>\n\n<p>PTS200</p>\n\n<p>417 1441 002</p>\n\n<p>050</p>\n\n<p>96242</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA620</p>\n\n<p>3230500</p>\n\n<p>051</p>\n\n<p>96244</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA620</p>\n\n<p>3248029</p>\n\n<p>052</p>\n\n<p>96247</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESA LABORATORIES INC</p>\n\n<p>90XL</p>\n\n<p>9X006008</p>\n\n<p>053</p>\n\n<p>96250</p>\n\n<p>POWER METER, ULTRASOUND, THERAPEUTIC UNIT</p>\n\n<p>BC GROUP INTERNATIONAL INC</p>\n\n<p>USP 50SP</p>\n\n<p>901265701027</p>\n\n<p>054</p>\n\n<p>96303</p>\n\n<p>ELECTRICAL CONDUCTIVITY METER, DIALYSATE</p>\n\n<p>YSI INC</p>\n\n<p>PRO30</p>\n\n<p>18A102848</p>\n\n<p>055</p>\n\n<p>96304</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED, SKIN</p>\n\n<p>EXERGEN CORP</p>\n\n<p>TAT-5000</p>\n\n<p>A148613</p>\n\n<p>056</p>\n\n<p>96335</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED, SKIN</p>\n\n<p>EXERGEN CORP</p>\n\n<p>TAT 5000</p>\n\n<p>A826169</p>\n\n<p>057</p>\n\n<p>96336</p>\n\n<p>PH METER</p>\n\n<p>MYRON L CO</p>\n\n<p>UNK</p>\n\n<p>611479</p>\n\n<p>058</p>\n\n<p>96482</p>\n\n<p>SIMULATOR, CARDIAC, HEART BEAT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PS320</p>\n\n<p>4219020</p>\n\n<p>059</p>\n\n<p>96729</p>\n\n<p>STRAIN GAUGES</p>\n\n<p>SCIENTIFIC INDUSTRIES INC</p>\n\n<p>FC1K</p>\n\n<p>F22010001066</p>\n\n<p>060</p>\n\n<p>97048</p>\n\n<p>TESTER, ELECTROSURGICAL UNIT</p>\n\n<p>BC GROUP INTERNATIONAL INC</p>\n\n<p>ESU2400</p>\n\n<p>7378H1128</p>\n\n<p>061</p>\n\n<p>97049</p>\n\n<p>TESTER, ELECTROSURGICAL UNIT</p>\n\n<p>BC GROUP INTERNATIONAL INC</p>\n\n<p>ESU2400</p>\n\n<p>7378H1131</p>\n\n<p>062</p>\n\n<p>97157</p>\n\n<p>TEMPERATURE MONITOR, ELECTRONIC</p>\n\n<p>STRYKER MEDICAL</p>\n\n<p>MISTRAL-AIR TEST</p>\n\n<p>160700174</p>\n\n<p>063</p>\n\n<p>97177</p>\n\n<p>SIMULATOR, CARDIAC, HEART BEAT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PS320</p>\n\n<p>4933023</p>\n\n<p>064</p>\n\n<p>97211</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>5093005</p>\n\n<p>065</p>\n\n<p>97212</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>5093006</p>\n\n<p>066</p>\n\n<p>97224</p>\n\n<p>SIMULATOR, CARDIAC, HEART BEAT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PS320</p>\n\n<p>4961032</p>\n\n<p>067</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3695</p>\n\n<p>068</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3693</p>\n\n<p>069</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3697</p>\n\n<p>070</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3694</p>\n\n<p>071</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3698</p>\n\n<p>072</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3696</p>\n\n<p>073</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ProSim SPOT</p>\n\n<p>3379022</p>\n\n<p>074</p>\n\n<p>N/A</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESALABS</p>\n\n<p>90XL pH Module</p>\n\n<p>PH002430</p>\n\n<p>075</p>\n\n<p>N/A</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESALABS</p>\n\n<p>90XL Dialysis Conductivity Temperature Module</p>\n\n<p>DCT06813</p>\n\n<p>076</p>\n\n<p>N/A</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESALABS</p>\n\n<p>90XL Differential PressureModule 30 PSID</p>\n\n<p>DP306254</p>\n\n<p>077</p>\n\n<p>N/A</p>\n\n<p>RESISTOR, POWER 200ohm 250 Watt</p>\n\n<p>DALE (BC BIOMEDICAL)</p>\n\n<p>NH-250</p>\n\n<p>7480992061346</p>\n\n<p>078</p>\n\n<p>N/A</p>\n\n<p>RESISTOR, POWER 200ohm 250 Watt</p>\n\n<p>DALE (BC BIOMEDICAL)</p>\n\n<p>NH-250</p>\n\n<p>7480992061347</p>\n\n<p>079</p>\n\n<p>96331</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687316</p>\n\n<p>080</p>\n\n<p>96332</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687317</p>\n\n<p>081</p>\n\n<p>96333</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687315</p>\n\n<p>082</p>\n\n<p>96334</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687332</p>\n\n<p>083</p>\n\n<p>N/A</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>TEKTRONIX</p>\n\n<p>TDS3012BNV</p>\n\n<p>B03336</p>\n\n<p>084</p>\n\n<p>N/A</p>\n\n<p>MEGOHMMETER</p>\n\n<p>BIDDLE</p>\n\n<p>212559</p>\n\n<p>951260</p>\n\n<p>085</p>\n\n<p>N/A</p>\n\n<p>TORQUE WRENCH 0-75 IN LBS</p>\n\n<p>CDI</p>\n\n<p>751DI</p>\n\n<p>4-85</p>\n\n<p>086</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>SIMPSON</p>\n\n<p>260-6XLP</p>\n\n<p>29</p>\n\n<p>087</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>77/BN</p>\n\n<p>56910583</p>\n\n<p>088</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>87V</p>\n\n<p>48220146</p>\n\n<p>089</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>87V</p>\n\n<p>48220150</p>\n\n<p>090</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>87V</p>\n\n<p>14160460</p>\n\n<p></p>\n\n<p>The Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1 &ndash; USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.</p>\n\n<p>NOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.</p>\n\n<p>Service deemed outside of the scope of this requirement.&nbsp; Defects in equipment or repairs beyond normal preventative and corrective maintenance are deemed to be outside the scope of this requirement.&nbsp; In these incidences, the Contractor shall immediately notify Contracting Officer, Contracting Officer Representative (COR), and Chief Biomedical Repair Tech (BMET) in writing and a written cost estimate for the repair/replacement.</p>\n\n<p>This notice of intent is not a request for competitive proposals. Sources interested in responding to this notice are required to submit a capability statement that includes management and technical data and price information, in sufficient detail and with convincing evidence that clearly demonstrates the capability to perform the required work. Capability statements shall not exceed five (8.5 x 11 inch) pages using a font size no smaller than 10-point. All capability statements received by the due date of this notice will be considered by the Government. A request for documentation or additional information will not be considered as an affirmative response or acceptance of the capability statement. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement or to proceed with a sole source contract. Capability statements should also include the business size and cage code.</p>\n\n<p>Capability statements are due by 2:00 PM Local Time, 07 July 2026. Capability statements shall be submitted by e-mail ONLY as a Microsoft Word or Adobe PDF attachment to the following address: curtis.e.cardoza.civ@us.navy.mil.</p>","text":"Pre-Solicitation Notice\n\nNotice of Intent to Sole Source\n\nUSNS Comfort T-AH 20 requires calibration services for its 90 Biomedical Test, Measurement, and Diagnostic Equipment (TMDE) to maintain operational readiness and ensure patient safety. Without these services, the equipment will not be certified, resulting in a break in service and a failure to meet healthcare standards. Furthermore, medical equipment that does not have a concurrent service history is deemed unsafe, not recommended for patient use and will affect mission readiness plus operational capabilities.\n\nNeed:\n\nUSNS COMFORT T-AH 20 is responsible for Naval worldwide medical response during combat operation and or humanitarian relief for allied Nations. The vessel is equipped with over 2,600 pieces of medical equipment to constantly provide high level medical care at its 1,000-patient capacity. This medical equipment is required to have semiannual or annual calibration and examination using unit and manufacture specific Biomedical Test, Measurement, and Diagnostic Equipment’s (TMDE). This TMDE is required to ensure patient safety, maintain mission readiness, and uphold operational standards. The equipment is regularly serviced, and periodic recertification is required to ensure that every tool remains accurate and fully functional for its users. Southeastern Biomedical Associates (incumbent) had provided all the required services for this requirement to include calibration services, shipping, and travel. Our Market research revealed that Southeastern Biomedical Associates is the only company capable of meeting the requirement.\n\nWithout periodic recertification, there is a significant risk of equipment failure, false data, or rapid wear-and-tear that could compromise medical operations. Keeping these tools properly maintained avoids treatment errors, ensure units are always ready for deployment, and extend the lifespan of the equipment to reduce long-term costs.\n\nThe Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1(Equipment List) – USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.\n\nNOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.\n\nThe USNS Comfort is a ready-5 status ship, so it is critical to have Bio Med equipment up and run according to manufacturer’s OEM.\n\nUSNS Comfort (T-AH 20) 90 Biomedical Test Equipment items identified below:\n\nITEM\n\nECN\n\nNOMENCLATURE\n\nMANUFACTURER\n\nMODEL NAME\n\nMFR. S/N\n\n001\n\n5135\n\nPHOTOTACHOMETER\n\nAMETEK TCI\n\n1726\n\n32594144\n\n002\n\n5485\n\nOSCILLOSCOPE\n\nFLUKE BIOMEDICAL\n\n99B\n\nDM6820583\n\n003\n\n60245\n\nOSCILLOSCOPE\n\nFLUKE BIOMEDICAL\n\n99B\n\nDM7310704\n\n004\n\n60248\n\nOSCILLOSCOPE\n\nFLUKE BIOMEDICAL\n\n99B\n\nDM7310706\n\n005\n\n60638\n\nTESTER, IMPLANTABLE CARDIAC PACEMAKER\n\nBIO TEK INSTRUMENTS INC\n\nPMA-1\n\n2184\n\n006\n\n70180\n\nPRESSURE METER, DIGITAL\n\nDYNATECH NEVADA\n\n207B\n\n3294\n\n007\n\n70242\n\nSAMPLER, ENVIRONMENTAL, AIR\n\nFLUKE BIOMEDICAL\n\nINCU\n\n6050303\n\n008\n\n92022\n\nTHERMOMETER, ELECTRONIC\n\nSIMS LEVEL 1 INC\n\nHLTA-40\n\n1999 0162\n\n009\n\n92023\n\nTHERMOMETER, ELECTRONIC\n\nSIMS LEVEL 1 INC\n\nHLTA-40\n\n2002 0102\n\n010\n\n92054\n\nTESTER, DEFIBRILLATOR\n\nFLUKE BIOMEDICAL\n\nQED 6\n\n9122026\n\n011\n\n92055\n\nTESTER, DEFIBRILLATOR\n\nFLUKE BIOMEDICAL\n\nQED 6\n\n9122024\n\n012\n\n92327\n\nMETER, WATT\n\nFLUKE BIOMEDICAL\n\nUW4\n\n9069005\n\n013\n\n92353\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM4-1G\n\n50057\n\n014\n\n92354\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM4-1G\n\n50070\n\n015\n\n92355\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM4-1G\n\n50056\n\n016\n\n92450\n\nFLOWMETER, GAS\n\nFLUKE BIOMEDICAL RADIATION MANAGEMENT\n\nVT MOBILE\n\n9777010\n\n017\n\n92796\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87V\n\n92070276\n\n018\n\n92877\n\nPHOTOTACHOMETER\n\nELECTROMATIC EQUIPMENT CO. INC\n\nDT-205L\n\nC086B0087\n\n019\n\n92880\n\nTESTER, VENTILATOR\n\nMALLINCKRODT INC\n\nPTS 2000\n\n4150823002\n\n020\n\n93357\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4071\n\n021\n\n93358\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4069\n\n022\n\n93359\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4068\n\n023\n\n93360\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4072\n\n024\n\n93361\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4066\n\n025\n\n93362\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4070\n\n026\n\n94026\n\nRADIOMETER, LASER\n\nOPHIR OPTRONICS INC\n\nNOVA\n\n610308\n\n027\n\nN/A\n\nLASER POWER SENSOR\n\nOPHIR OPTRONICS INC\n\n30 (150)A-HE-SH-17, ROH\n\n585851\n\n028\n\n94186\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n9802051\n\n029\n\n94187\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n9802007\n\n030\n\n94286\n\nTHERMOMETER, ELECTRONIC\n\nSMITHS MEDICAL ASD INC\n\nHLTA-40\n\nS112A00093\n\n031\n\n95381\n\nTHERMOMETER, ELECTRONIC\n\nSMITHS MEDICAL\n\nDSTA-40\n\nS111A00867\n\n032\n\n95563\n\nSAMPLER, ENVIRONMENTAL, AIR, GAS/VAPOR\n\nRIKEN KEIKI CO LTD\n\nFI-21\n\n469010011ES\n\n033\n\n95905\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n33080280\n\n034\n\n95906\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670345\n\n035\n\n95907\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670346\n\n036\n\n95908\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670331\n\n037\n\n95910\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670348\n\n038\n\n95911\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680159\n\n039\n\n95912\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680155\n\n040\n\n95913\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680160\n\n041\n\n95914\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680162\n\n042\n\n95915\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680161\n\n043\n\n95916\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n33080281\n\n044\n\n95968\n\nSIMULATOR, MULTIPARAMETER\n\nFLUKE BIOMEDICAL\n\nPROSIM 8\n\n3396033\n\n045\n\n95969\n\nSIMULATOR, MULTIPARAMETER\n\nFLUKE BIOMEDICAL\n\nPROSIM 8\n\n3399037\n\n046\n\n95992\n\nTESTER, DEFIBRILLATOR\n\nFLUKE BIOMEDICAL\n\nIMPULSE 7000DP\n\n340109\n\n047\n\n95996\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA615\n\n3401026\n\n048\n\n95997\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA615\n\n3400035\n\n049\n\n96023\n\nTESTER, VENTILATOR\n\nCOVIDIEN NELLCOR/PURITAN BENNETT\n\nPTS200\n\n417 1441 002\n\n050\n\n96242\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA620\n\n3230500\n\n051\n\n96244\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA620\n\n3248029\n\n052\n\n96247\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESA LABORATORIES INC\n\n90XL\n\n9X006008\n\n053\n\n96250\n\nPOWER METER, ULTRASOUND, THERAPEUTIC UNIT\n\nBC GROUP INTERNATIONAL INC\n\nUSP 50SP\n\n901265701027\n\n054\n\n96303\n\nELECTRICAL CONDUCTIVITY METER, DIALYSATE\n\nYSI INC\n\nPRO30\n\n18A102848\n\n055\n\n96304\n\nTHERMOMETER, ELECTRONIC, INFRARED, SKIN\n\nEXERGEN CORP\n\nTAT-5000\n\nA148613\n\n056\n\n96335\n\nTHERMOMETER, ELECTRONIC, INFRARED, SKIN\n\nEXERGEN CORP\n\nTAT 5000\n\nA826169\n\n057\n\n96336\n\nPH METER\n\nMYRON L CO\n\nUNK\n\n611479\n\n058\n\n96482\n\nSIMULATOR, CARDIAC, HEART BEAT\n\nFLUKE BIOMEDICAL\n\nPS320\n\n4219020\n\n059\n\n96729\n\nSTRAIN GAUGES\n\nSCIENTIFIC INDUSTRIES INC\n\nFC1K\n\nF22010001066\n\n060\n\n97048\n\nTESTER, ELECTROSURGICAL UNIT\n\nBC GROUP INTERNATIONAL INC\n\nESU2400\n\n7378H1128\n\n061\n\n97049\n\nTESTER, ELECTROSURGICAL UNIT\n\nBC GROUP INTERNATIONAL INC\n\nESU2400\n\n7378H1131\n\n062\n\n97157\n\nTEMPERATURE MONITOR, ELECTRONIC\n\nSTRYKER MEDICAL\n\nMISTRAL-AIR TEST\n\n160700174\n\n063\n\n97177\n\nSIMULATOR, CARDIAC, HEART BEAT\n\nFLUKE BIOMEDICAL\n\nPS320\n\n4933023\n\n064\n\n97211\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n5093005\n\n065\n\n97212\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n5093006\n\n066\n\n97224\n\nSIMULATOR, CARDIAC, HEART BEAT\n\nFLUKE BIOMEDICAL\n\nPS320\n\n4961032\n\n067\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3695\n\n068\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3693\n\n069\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3697\n\n070\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3694\n\n071\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3698\n\n072\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3696\n\n073\n\nN/A\n\nSIMULATOR Sp02\n\nFLUKE BIOMEDICAL\n\nProSim SPOT\n\n3379022\n\n074\n\nN/A\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESALABS\n\n90XL pH Module\n\nPH002430\n\n075\n\nN/A\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESALABS\n\n90XL Dialysis Conductivity Temperature Module\n\nDCT06813\n\n076\n\nN/A\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESALABS\n\n90XL Differential PressureModule 30 PSID\n\nDP306254\n\n077\n\nN/A\n\nRESISTOR, POWER 200ohm 250 Watt\n\nDALE (BC BIOMEDICAL)\n\nNH-250\n\n7480992061346\n\n078\n\nN/A\n\nRESISTOR, POWER 200ohm 250 Watt\n\nDALE (BC BIOMEDICAL)\n\nNH-250\n\n7480992061347\n\n079\n\n96331\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687316\n\n080\n\n96332\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687317\n\n081\n\n96333\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687315\n\n082\n\n96334\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687332\n\n083\n\nN/A\n\nOSCILLOSCOPE\n\nTEKTRONIX\n\nTDS3012BNV\n\nB03336\n\n084\n\nN/A\n\nMEGOHMMETER\n\nBIDDLE\n\n212559\n\n951260\n\n085\n\nN/A\n\nTORQUE WRENCH 0-75 IN LBS\n\nCDI\n\n751DI\n\n4-85\n\n086\n\nN/A\n\nMULTIMETER\n\nSIMPSON\n\n260-6XLP\n\n29\n\n087\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n77/BN\n\n56910583\n\n088\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n87V\n\n48220146\n\n089\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n87V\n\n48220150\n\n090\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n87V\n\n14160460\n\nThe Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1 – USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.\n\nNOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.\n\nService deemed outside of the scope of this requirement. Defects in equipment or repairs beyond normal preventative and corrective maintenance are deemed to be outside the scope of this requirement. In these incidences, the Contractor shall immediately notify Contracting Officer, Contracting Officer Representative (COR), and Chief Biomedical Repair Tech (BMET) in writing and a written cost estimate for the repair/replacement.\n\nThis notice of intent is not a request for competitive proposals. Sources interested in responding to this notice are required to submit a capability statement that includes management and technical data and price information, in sufficient detail and with convincing evidence that clearly demonstrates the capability to perform the required work. Capability statements shall not exceed five (8.5 x 11 inch) pages using a font size no smaller than 10-point. All capability statements received by the due date of this notice will be considered by the Government. A request for documentation or additional information will not be considered as an affirmative response or acceptance of the capability statement. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement or to proceed with a sole source contract. Capability statements should also include the business size and cage code.\n\nCapability statements are due by 2:00 PM Local Time, 07 July 2026. Capability statements shall be submitted by e-mail ONLY as a Microsoft Word or Adobe PDF attachment to the following address: curtis.e.cardoza.civ@us.navy.mil.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"N0003326PR02399","place_of_performance":{"zip":"23501","state":{"code":"VA","name":"Virginia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J065"}],"due_at":"2026-07-07T18:00:00Z","due_date":"2026-07-07","closes_at":"2026-07-07T18:00:00Z","awardable":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-n-DEPTOFTHENAVY","office_name":"DEPT OF THE NAVY","state":"VA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-01T01:11:37.507596Z","principal_notice_id":"c685e5955ab34c9cb49f1dd320a4be7b","description":{"text":"Pre-Solicitation Notice\n\nNotice of Intent to Sole Source\n\nUSNS Comfort T-AH 20 requires calibration services for its 90 Biomedical Test, Measurement, and Diagnostic Equipment (TMDE) to maintain operational readiness and ensure patient safety. Without these services, the equipment will not be certified, resulting in a break in service and a failure to meet healthcare standards. Furthermore, medical equipment that does not have a concurrent service history is deemed unsafe, not recommended for patient use and will affect mission readiness plus operational capabilities.\n\nNeed:\n\nUSNS COMFORT T-AH 20 is responsible for Naval worldwide medical response during combat operation and or humanitarian relief for allied Nations. The vessel is equipped with over 2,600 pieces of medical equipment to constantly provide high level medical care at its 1,000-patient capacity. This medical equipment is required to have semiannual or annual calibration and examination using unit and manufacture specific Biomedical Test, Measurement, and Diagnostic Equipment’s (TMDE). This TMDE is required to ensure patient safety, maintain mission readiness, and uphold operational standards. The equipment is regularly serviced, and periodic recertification is required to ensure that every tool remains accurate and fully functional for its users. Southeastern Biomedical Associates (incumbent) had provided all the required services for this requirement to include calibration services, shipping, and travel. Our Market research revealed that Southeastern Biomedical Associates is the only company capable of meeting the requirement.\n\nWithout periodic recertification, there is a significant risk of equipment failure, false data, or rapid wear-and-tear that could compromise medical operations. Keeping these tools properly maintained avoids treatment errors, ensure units are always ready for deployment, and extend the lifespan of the equipment to reduce long-term costs.\n\nThe Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1(Equipment List) – USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.\n\nNOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.\n\nThe USNS Comfort is a ready-5 status ship, so it is critical to have Bio Med equipment up and run according to manufacturer’s OEM.\n\nUSNS Comfort (T-AH 20) 90 Biomedical Test Equipment items identified below:\n\nITEM\n\nECN\n\nNOMENCLATURE\n\nMANUFACTURER\n\nMODEL NAME\n\nMFR. S/N\n\n001\n\n5135\n\nPHOTOTACHOMETER\n\nAMETEK TCI\n\n1726\n\n32594144\n\n002\n\n5485\n\nOSCILLOSCOPE\n\nFLUKE BIOMEDICAL\n\n99B\n\nDM6820583\n\n003\n\n60245\n\nOSCILLOSCOPE\n\nFLUKE BIOMEDICAL\n\n99B\n\nDM7310704\n\n004\n\n60248\n\nOSCILLOSCOPE\n\nFLUKE BIOMEDICAL\n\n99B\n\nDM7310706\n\n005\n\n60638\n\nTESTER, IMPLANTABLE CARDIAC PACEMAKER\n\nBIO TEK INSTRUMENTS INC\n\nPMA-1\n\n2184\n\n006\n\n70180\n\nPRESSURE METER, DIGITAL\n\nDYNATECH NEVADA\n\n207B\n\n3294\n\n007\n\n70242\n\nSAMPLER, ENVIRONMENTAL, AIR\n\nFLUKE BIOMEDICAL\n\nINCU\n\n6050303\n\n008\n\n92022\n\nTHERMOMETER, ELECTRONIC\n\nSIMS LEVEL 1 INC\n\nHLTA-40\n\n1999 0162\n\n009\n\n92023\n\nTHERMOMETER, ELECTRONIC\n\nSIMS LEVEL 1 INC\n\nHLTA-40\n\n2002 0102\n\n010\n\n92054\n\nTESTER, DEFIBRILLATOR\n\nFLUKE BIOMEDICAL\n\nQED 6\n\n9122026\n\n011\n\n92055\n\nTESTER, DEFIBRILLATOR\n\nFLUKE BIOMEDICAL\n\nQED 6\n\n9122024\n\n012\n\n92327\n\nMETER, WATT\n\nFLUKE BIOMEDICAL\n\nUW4\n\n9069005\n\n013\n\n92353\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM4-1G\n\n50057\n\n014\n\n92354\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM4-1G\n\n50070\n\n015\n\n92355\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM4-1G\n\n50056\n\n016\n\n92450\n\nFLOWMETER, GAS\n\nFLUKE BIOMEDICAL RADIATION MANAGEMENT\n\nVT MOBILE\n\n9777010\n\n017\n\n92796\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87V\n\n92070276\n\n018\n\n92877\n\nPHOTOTACHOMETER\n\nELECTROMATIC EQUIPMENT CO. INC\n\nDT-205L\n\nC086B0087\n\n019\n\n92880\n\nTESTER, VENTILATOR\n\nMALLINCKRODT INC\n\nPTS 2000\n\n4150823002\n\n020\n\n93357\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4071\n\n021\n\n93358\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4069\n\n022\n\n93359\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4068\n\n023\n\n93360\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4072\n\n024\n\n93361\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4066\n\n025\n\n93362\n\nSIMULATOR, MULTIPARAMETER\n\nPRONK TECHNOLOGIES INC\n\nSIM CUBE\n\n4070\n\n026\n\n94026\n\nRADIOMETER, LASER\n\nOPHIR OPTRONICS INC\n\nNOVA\n\n610308\n\n027\n\nN/A\n\nLASER POWER SENSOR\n\nOPHIR OPTRONICS INC\n\n30 (150)A-HE-SH-17, ROH\n\n585851\n\n028\n\n94186\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n9802051\n\n029\n\n94187\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n9802007\n\n030\n\n94286\n\nTHERMOMETER, ELECTRONIC\n\nSMITHS MEDICAL ASD INC\n\nHLTA-40\n\nS112A00093\n\n031\n\n95381\n\nTHERMOMETER, ELECTRONIC\n\nSMITHS MEDICAL\n\nDSTA-40\n\nS111A00867\n\n032\n\n95563\n\nSAMPLER, ENVIRONMENTAL, AIR, GAS/VAPOR\n\nRIKEN KEIKI CO LTD\n\nFI-21\n\n469010011ES\n\n033\n\n95905\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n33080280\n\n034\n\n95906\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670345\n\n035\n\n95907\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670346\n\n036\n\n95908\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670331\n\n037\n\n95910\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32670348\n\n038\n\n95911\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680159\n\n039\n\n95912\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680155\n\n040\n\n95913\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680160\n\n041\n\n95914\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680162\n\n042\n\n95915\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n32680161\n\n043\n\n95916\n\nELECTRICAL MULTIMETERS\n\nFLUKE BIOMEDICAL\n\n87 V\n\n33080281\n\n044\n\n95968\n\nSIMULATOR, MULTIPARAMETER\n\nFLUKE BIOMEDICAL\n\nPROSIM 8\n\n3396033\n\n045\n\n95969\n\nSIMULATOR, MULTIPARAMETER\n\nFLUKE BIOMEDICAL\n\nPROSIM 8\n\n3399037\n\n046\n\n95992\n\nTESTER, DEFIBRILLATOR\n\nFLUKE BIOMEDICAL\n\nIMPULSE 7000DP\n\n340109\n\n047\n\n95996\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA615\n\n3401026\n\n048\n\n95997\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA615\n\n3400035\n\n049\n\n96023\n\nTESTER, VENTILATOR\n\nCOVIDIEN NELLCOR/PURITAN BENNETT\n\nPTS200\n\n417 1441 002\n\n050\n\n96242\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA620\n\n3230500\n\n051\n\n96244\n\nTESTER, ELECTRICAL SAFETY\n\nFLUKE BIOMEDICAL\n\nESA620\n\n3248029\n\n052\n\n96247\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESA LABORATORIES INC\n\n90XL\n\n9X006008\n\n053\n\n96250\n\nPOWER METER, ULTRASOUND, THERAPEUTIC UNIT\n\nBC GROUP INTERNATIONAL INC\n\nUSP 50SP\n\n901265701027\n\n054\n\n96303\n\nELECTRICAL CONDUCTIVITY METER, DIALYSATE\n\nYSI INC\n\nPRO30\n\n18A102848\n\n055\n\n96304\n\nTHERMOMETER, ELECTRONIC, INFRARED, SKIN\n\nEXERGEN CORP\n\nTAT-5000\n\nA148613\n\n056\n\n96335\n\nTHERMOMETER, ELECTRONIC, INFRARED, SKIN\n\nEXERGEN CORP\n\nTAT 5000\n\nA826169\n\n057\n\n96336\n\nPH METER\n\nMYRON L CO\n\nUNK\n\n611479\n\n058\n\n96482\n\nSIMULATOR, CARDIAC, HEART BEAT\n\nFLUKE BIOMEDICAL\n\nPS320\n\n4219020\n\n059\n\n96729\n\nSTRAIN GAUGES\n\nSCIENTIFIC INDUSTRIES INC\n\nFC1K\n\nF22010001066\n\n060\n\n97048\n\nTESTER, ELECTROSURGICAL UNIT\n\nBC GROUP INTERNATIONAL INC\n\nESU2400\n\n7378H1128\n\n061\n\n97049\n\nTESTER, ELECTROSURGICAL UNIT\n\nBC GROUP INTERNATIONAL INC\n\nESU2400\n\n7378H1131\n\n062\n\n97157\n\nTEMPERATURE MONITOR, ELECTRONIC\n\nSTRYKER MEDICAL\n\nMISTRAL-AIR TEST\n\n160700174\n\n063\n\n97177\n\nSIMULATOR, CARDIAC, HEART BEAT\n\nFLUKE BIOMEDICAL\n\nPS320\n\n4933023\n\n064\n\n97211\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n5093005\n\n065\n\n97212\n\nPRESSURE METER, DIGITAL\n\nFLUKE BIOMEDICAL\n\nDPM2PLUS\n\n5093006\n\n066\n\n97224\n\nSIMULATOR, CARDIAC, HEART BEAT\n\nFLUKE BIOMEDICAL\n\nPS320\n\n4961032\n\n067\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3695\n\n068\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3693\n\n069\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3697\n\n070\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3694\n\n071\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3698\n\n072\n\nN/A\n\nSIMULATOR Sp02\n\nPRONK TECHNOLOGIES INC\n\nOX-1\n\n0x3696\n\n073\n\nN/A\n\nSIMULATOR Sp02\n\nFLUKE BIOMEDICAL\n\nProSim SPOT\n\n3379022\n\n074\n\nN/A\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESALABS\n\n90XL pH Module\n\nPH002430\n\n075\n\nN/A\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESALABS\n\n90XL Dialysis Conductivity Temperature Module\n\nDCT06813\n\n076\n\nN/A\n\nTESTER, HEMODIALYSIS DIALYSATE\n\nMESALABS\n\n90XL Differential PressureModule 30 PSID\n\nDP306254\n\n077\n\nN/A\n\nRESISTOR, POWER 200ohm 250 Watt\n\nDALE (BC BIOMEDICAL)\n\nNH-250\n\n7480992061346\n\n078\n\nN/A\n\nRESISTOR, POWER 200ohm 250 Watt\n\nDALE (BC BIOMEDICAL)\n\nNH-250\n\n7480992061347\n\n079\n\n96331\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687316\n\n080\n\n96332\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687317\n\n081\n\n96333\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687315\n\n082\n\n96334\n\nTHERMOMETER, ELECTRONIC, INFRARED\n\nFISHER BRAND\n\nFISHER BRAND\n\n170687332\n\n083\n\nN/A\n\nOSCILLOSCOPE\n\nTEKTRONIX\n\nTDS3012BNV\n\nB03336\n\n084\n\nN/A\n\nMEGOHMMETER\n\nBIDDLE\n\n212559\n\n951260\n\n085\n\nN/A\n\nTORQUE WRENCH 0-75 IN LBS\n\nCDI\n\n751DI\n\n4-85\n\n086\n\nN/A\n\nMULTIMETER\n\nSIMPSON\n\n260-6XLP\n\n29\n\n087\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n77/BN\n\n56910583\n\n088\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n87V\n\n48220146\n\n089\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n87V\n\n48220150\n\n090\n\nN/A\n\nMULTIMETER\n\nFLUKE\n\n87V\n\n14160460\n\nThe Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1 – USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.\n\nNOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.\n\nService deemed outside of the scope of this requirement. Defects in equipment or repairs beyond normal preventative and corrective maintenance are deemed to be outside the scope of this requirement. In these incidences, the Contractor shall immediately notify Contracting Officer, Contracting Officer Representative (COR), and Chief Biomedical Repair Tech (BMET) in writing and a written cost estimate for the repair/replacement.\n\nThis notice of intent is not a request for competitive proposals. Sources interested in responding to this notice are required to submit a capability statement that includes management and technical data and price information, in sufficient detail and with convincing evidence that clearly demonstrates the capability to perform the required work. Capability statements shall not exceed five (8.5 x 11 inch) pages using a font size no smaller than 10-point. All capability statements received by the due date of this notice will be considered by the Government. A request for documentation or additional information will not be considered as an affirmative response or acceptance of the capability statement. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement or to proceed with a sole source contract. Capability statements should also include the business size and cage code.\n\nCapability statements are due by 2:00 PM Local Time, 07 July 2026. Capability statements shall be submitted by e-mail ONLY as a Microsoft Word or Adobe PDF attachment to the following address: curtis.e.cardoza.civ@us.navy.mil.","html":"<p>Pre-Solicitation Notice</p>\n\n<p>Notice of Intent to Sole Source</p>\n\n<p>USNS Comfort T-AH 20 requires calibration services for its 90 Biomedical Test, Measurement, and Diagnostic Equipment (TMDE) to maintain operational readiness and ensure patient safety. Without these services, the equipment will not be certified, resulting in a break in service and a failure to meet healthcare standards. Furthermore, medical equipment that does not have a concurrent service history is deemed unsafe, not recommended for patient use and will affect mission readiness plus operational capabilities.</p>\n\n<p><strong>Need:</strong></p>\n\n<p>USNS COMFORT T-AH 20 is responsible for Naval worldwide medical response during combat operation and or humanitarian relief for allied Nations. The vessel is equipped with over 2,600 pieces of medical equipment to constantly provide high level medical care at its 1,000-patient capacity. This medical equipment is required to have semiannual or annual calibration and examination using unit and manufacture specific Biomedical Test, Measurement, and Diagnostic Equipment&rsquo;s (TMDE). This TMDE is required to ensure patient safety, maintain mission readiness, and uphold operational standards.&nbsp; The equipment is regularly serviced, and periodic recertification is required to ensure that every tool remains accurate and fully functional for its users. Southeastern Biomedical Associates (incumbent) had provided all the required services for this requirement to include calibration services, shipping, and travel. Our Market research revealed that Southeastern Biomedical Associates is the only company capable of meeting the requirement.</p>\n\n<p>Without periodic recertification, there is a significant risk of equipment failure, false data, or rapid wear-and-tear that could compromise medical operations. Keeping these tools properly maintained avoids treatment errors, ensure units are always ready for deployment, and extend the lifespan of the equipment to reduce long-term costs.</p>\n\n<p>The Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1(Equipment List) &ndash; USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.</p>\n\n<p>NOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.</p>\n\n<p>The USNS Comfort is a ready-5 status ship, so it is critical to have Bio Med equipment up and run according to manufacturer&rsquo;s OEM.</p>\n\n<p>USNS Comfort (T-AH 20) 90 Biomedical Test Equipment items identified below:</p>\n\n<p>ITEM</p>\n\n<p>ECN</p>\n\n<p>NOMENCLATURE</p>\n\n<p>MANUFACTURER</p>\n\n<p>MODEL NAME</p>\n\n<p>MFR. S/N</p>\n\n<p>001</p>\n\n<p>5135</p>\n\n<p>PHOTOTACHOMETER</p>\n\n<p>AMETEK TCI</p>\n\n<p>1726</p>\n\n<p>32594144</p>\n\n<p>002</p>\n\n<p>5485</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>99B</p>\n\n<p>DM6820583</p>\n\n<p>003</p>\n\n<p>60245</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>99B</p>\n\n<p>DM7310704</p>\n\n<p>004</p>\n\n<p>60248</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>99B</p>\n\n<p>DM7310706</p>\n\n<p>005</p>\n\n<p>60638</p>\n\n<p>TESTER, IMPLANTABLE CARDIAC PACEMAKER</p>\n\n<p>BIO TEK INSTRUMENTS INC</p>\n\n<p>PMA-1</p>\n\n<p>2184</p>\n\n<p>006</p>\n\n<p>70180</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>DYNATECH NEVADA</p>\n\n<p>207B</p>\n\n<p>3294</p>\n\n<p>007</p>\n\n<p>70242</p>\n\n<p>SAMPLER, ENVIRONMENTAL, AIR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>INCU</p>\n\n<p>6050303</p>\n\n<p>008</p>\n\n<p>92022</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SIMS LEVEL 1 INC</p>\n\n<p>HLTA-40</p>\n\n<p>1999 0162</p>\n\n<p>009</p>\n\n<p>92023</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SIMS LEVEL 1 INC</p>\n\n<p>HLTA-40</p>\n\n<p>2002 0102</p>\n\n<p>010</p>\n\n<p>92054</p>\n\n<p>TESTER, DEFIBRILLATOR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>QED 6</p>\n\n<p>9122026</p>\n\n<p>011</p>\n\n<p>92055</p>\n\n<p>TESTER, DEFIBRILLATOR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>QED 6</p>\n\n<p>9122024</p>\n\n<p>012</p>\n\n<p>92327</p>\n\n<p>METER, WATT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>UW4</p>\n\n<p>9069005</p>\n\n<p>013</p>\n\n<p>92353</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM4-1G</p>\n\n<p>50057</p>\n\n<p>014</p>\n\n<p>92354</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM4-1G</p>\n\n<p>50070</p>\n\n<p>015</p>\n\n<p>92355</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM4-1G</p>\n\n<p>50056</p>\n\n<p>016</p>\n\n<p>92450</p>\n\n<p>FLOWMETER, GAS</p>\n\n<p>FLUKE BIOMEDICAL RADIATION MANAGEMENT</p>\n\n<p>VT MOBILE</p>\n\n<p>9777010</p>\n\n<p>017</p>\n\n<p>92796</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87V</p>\n\n<p>92070276</p>\n\n<p>018</p>\n\n<p>92877</p>\n\n<p>PHOTOTACHOMETER</p>\n\n<p>ELECTROMATIC EQUIPMENT CO. INC</p>\n\n<p>DT-205L</p>\n\n<p>C086B0087</p>\n\n<p>019</p>\n\n<p>92880</p>\n\n<p>TESTER, VENTILATOR</p>\n\n<p>MALLINCKRODT INC</p>\n\n<p>PTS 2000</p>\n\n<p>4150823002</p>\n\n<p>020</p>\n\n<p>93357</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4071</p>\n\n<p>021</p>\n\n<p>93358</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4069</p>\n\n<p>022</p>\n\n<p>93359</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4068</p>\n\n<p>023</p>\n\n<p>93360</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4072</p>\n\n<p>024</p>\n\n<p>93361</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4066</p>\n\n<p>025</p>\n\n<p>93362</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>SIM CUBE</p>\n\n<p>4070</p>\n\n<p>026</p>\n\n<p>94026</p>\n\n<p>RADIOMETER, LASER</p>\n\n<p>OPHIR OPTRONICS INC</p>\n\n<p>NOVA</p>\n\n<p>610308</p>\n\n<p>027</p>\n\n<p>N/A</p>\n\n<p>LASER POWER SENSOR</p>\n\n<p>OPHIR OPTRONICS INC</p>\n\n<p>30 (150)A-HE-SH-17, ROH</p>\n\n<p>585851</p>\n\n<p>028</p>\n\n<p>94186</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>9802051</p>\n\n<p>029</p>\n\n<p>94187</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>9802007</p>\n\n<p>030</p>\n\n<p>94286</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SMITHS MEDICAL ASD INC</p>\n\n<p>HLTA-40</p>\n\n<p>S112A00093</p>\n\n<p>031</p>\n\n<p>95381</p>\n\n<p>THERMOMETER, ELECTRONIC</p>\n\n<p>SMITHS MEDICAL</p>\n\n<p>DSTA-40</p>\n\n<p>S111A00867</p>\n\n<p>032</p>\n\n<p>95563</p>\n\n<p>SAMPLER, ENVIRONMENTAL, AIR, GAS/VAPOR</p>\n\n<p>RIKEN KEIKI CO LTD</p>\n\n<p>FI-21</p>\n\n<p>469010011ES</p>\n\n<p>033</p>\n\n<p>95905</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>33080280</p>\n\n<p>034</p>\n\n<p>95906</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670345</p>\n\n<p>035</p>\n\n<p>95907</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670346</p>\n\n<p>036</p>\n\n<p>95908</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670331</p>\n\n<p>037</p>\n\n<p>95910</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32670348</p>\n\n<p>038</p>\n\n<p>95911</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680159</p>\n\n<p>039</p>\n\n<p>95912</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680155</p>\n\n<p>040</p>\n\n<p>95913</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680160</p>\n\n<p>041</p>\n\n<p>95914</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680162</p>\n\n<p>042</p>\n\n<p>95915</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>32680161</p>\n\n<p>043</p>\n\n<p>95916</p>\n\n<p>ELECTRICAL MULTIMETERS</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>87 V</p>\n\n<p>33080281</p>\n\n<p>044</p>\n\n<p>95968</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PROSIM 8</p>\n\n<p>3396033</p>\n\n<p>045</p>\n\n<p>95969</p>\n\n<p>SIMULATOR, MULTIPARAMETER</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PROSIM 8</p>\n\n<p>3399037</p>\n\n<p>046</p>\n\n<p>95992</p>\n\n<p>TESTER, DEFIBRILLATOR</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>IMPULSE 7000DP</p>\n\n<p>340109</p>\n\n<p>047</p>\n\n<p>95996</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA615</p>\n\n<p>3401026</p>\n\n<p>048</p>\n\n<p>95997</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA615</p>\n\n<p>3400035</p>\n\n<p>049</p>\n\n<p>96023</p>\n\n<p>TESTER, VENTILATOR</p>\n\n<p>COVIDIEN NELLCOR/PURITAN BENNETT</p>\n\n<p>PTS200</p>\n\n<p>417 1441 002</p>\n\n<p>050</p>\n\n<p>96242</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA620</p>\n\n<p>3230500</p>\n\n<p>051</p>\n\n<p>96244</p>\n\n<p>TESTER, ELECTRICAL SAFETY</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ESA620</p>\n\n<p>3248029</p>\n\n<p>052</p>\n\n<p>96247</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESA LABORATORIES INC</p>\n\n<p>90XL</p>\n\n<p>9X006008</p>\n\n<p>053</p>\n\n<p>96250</p>\n\n<p>POWER METER, ULTRASOUND, THERAPEUTIC UNIT</p>\n\n<p>BC GROUP INTERNATIONAL INC</p>\n\n<p>USP 50SP</p>\n\n<p>901265701027</p>\n\n<p>054</p>\n\n<p>96303</p>\n\n<p>ELECTRICAL CONDUCTIVITY METER, DIALYSATE</p>\n\n<p>YSI INC</p>\n\n<p>PRO30</p>\n\n<p>18A102848</p>\n\n<p>055</p>\n\n<p>96304</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED, SKIN</p>\n\n<p>EXERGEN CORP</p>\n\n<p>TAT-5000</p>\n\n<p>A148613</p>\n\n<p>056</p>\n\n<p>96335</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED, SKIN</p>\n\n<p>EXERGEN CORP</p>\n\n<p>TAT 5000</p>\n\n<p>A826169</p>\n\n<p>057</p>\n\n<p>96336</p>\n\n<p>PH METER</p>\n\n<p>MYRON L CO</p>\n\n<p>UNK</p>\n\n<p>611479</p>\n\n<p>058</p>\n\n<p>96482</p>\n\n<p>SIMULATOR, CARDIAC, HEART BEAT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PS320</p>\n\n<p>4219020</p>\n\n<p>059</p>\n\n<p>96729</p>\n\n<p>STRAIN GAUGES</p>\n\n<p>SCIENTIFIC INDUSTRIES INC</p>\n\n<p>FC1K</p>\n\n<p>F22010001066</p>\n\n<p>060</p>\n\n<p>97048</p>\n\n<p>TESTER, ELECTROSURGICAL UNIT</p>\n\n<p>BC GROUP INTERNATIONAL INC</p>\n\n<p>ESU2400</p>\n\n<p>7378H1128</p>\n\n<p>061</p>\n\n<p>97049</p>\n\n<p>TESTER, ELECTROSURGICAL UNIT</p>\n\n<p>BC GROUP INTERNATIONAL INC</p>\n\n<p>ESU2400</p>\n\n<p>7378H1131</p>\n\n<p>062</p>\n\n<p>97157</p>\n\n<p>TEMPERATURE MONITOR, ELECTRONIC</p>\n\n<p>STRYKER MEDICAL</p>\n\n<p>MISTRAL-AIR TEST</p>\n\n<p>160700174</p>\n\n<p>063</p>\n\n<p>97177</p>\n\n<p>SIMULATOR, CARDIAC, HEART BEAT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PS320</p>\n\n<p>4933023</p>\n\n<p>064</p>\n\n<p>97211</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>5093005</p>\n\n<p>065</p>\n\n<p>97212</p>\n\n<p>PRESSURE METER, DIGITAL</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>DPM2PLUS</p>\n\n<p>5093006</p>\n\n<p>066</p>\n\n<p>97224</p>\n\n<p>SIMULATOR, CARDIAC, HEART BEAT</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>PS320</p>\n\n<p>4961032</p>\n\n<p>067</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3695</p>\n\n<p>068</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3693</p>\n\n<p>069</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3697</p>\n\n<p>070</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3694</p>\n\n<p>071</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3698</p>\n\n<p>072</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>PRONK TECHNOLOGIES INC</p>\n\n<p>OX-1</p>\n\n<p>0x3696</p>\n\n<p>073</p>\n\n<p>N/A</p>\n\n<p>SIMULATOR Sp02</p>\n\n<p>FLUKE BIOMEDICAL</p>\n\n<p>ProSim SPOT</p>\n\n<p>3379022</p>\n\n<p>074</p>\n\n<p>N/A</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESALABS</p>\n\n<p>90XL pH Module</p>\n\n<p>PH002430</p>\n\n<p>075</p>\n\n<p>N/A</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESALABS</p>\n\n<p>90XL Dialysis Conductivity Temperature Module</p>\n\n<p>DCT06813</p>\n\n<p>076</p>\n\n<p>N/A</p>\n\n<p>TESTER, HEMODIALYSIS DIALYSATE</p>\n\n<p>MESALABS</p>\n\n<p>90XL Differential PressureModule 30 PSID</p>\n\n<p>DP306254</p>\n\n<p>077</p>\n\n<p>N/A</p>\n\n<p>RESISTOR, POWER 200ohm 250 Watt</p>\n\n<p>DALE (BC BIOMEDICAL)</p>\n\n<p>NH-250</p>\n\n<p>7480992061346</p>\n\n<p>078</p>\n\n<p>N/A</p>\n\n<p>RESISTOR, POWER 200ohm 250 Watt</p>\n\n<p>DALE (BC BIOMEDICAL)</p>\n\n<p>NH-250</p>\n\n<p>7480992061347</p>\n\n<p>079</p>\n\n<p>96331</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687316</p>\n\n<p>080</p>\n\n<p>96332</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687317</p>\n\n<p>081</p>\n\n<p>96333</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687315</p>\n\n<p>082</p>\n\n<p>96334</p>\n\n<p>THERMOMETER, ELECTRONIC, INFRARED</p>\n\n<p>FISHER BRAND</p>\n\n<p>FISHER BRAND</p>\n\n<p>170687332</p>\n\n<p>083</p>\n\n<p>N/A</p>\n\n<p>OSCILLOSCOPE</p>\n\n<p>TEKTRONIX</p>\n\n<p>TDS3012BNV</p>\n\n<p>B03336</p>\n\n<p>084</p>\n\n<p>N/A</p>\n\n<p>MEGOHMMETER</p>\n\n<p>BIDDLE</p>\n\n<p>212559</p>\n\n<p>951260</p>\n\n<p>085</p>\n\n<p>N/A</p>\n\n<p>TORQUE WRENCH 0-75 IN LBS</p>\n\n<p>CDI</p>\n\n<p>751DI</p>\n\n<p>4-85</p>\n\n<p>086</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>SIMPSON</p>\n\n<p>260-6XLP</p>\n\n<p>29</p>\n\n<p>087</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>77/BN</p>\n\n<p>56910583</p>\n\n<p>088</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>87V</p>\n\n<p>48220146</p>\n\n<p>089</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>87V</p>\n\n<p>48220150</p>\n\n<p>090</p>\n\n<p>N/A</p>\n\n<p>MULTIMETER</p>\n\n<p>FLUKE</p>\n\n<p>87V</p>\n\n<p>14160460</p>\n\n<p></p>\n\n<p>The Contractor shall provide for all-inclusive labor, supervision, parts, diagnostic equipment, inspections, and shipping, necessary for calibration and any required corrective maintenance for all equipment identified above and in attachment 1 &ndash; USNS COMFORT Biomedical Test Equipment List to perform all maintenance actions mandated by the original manufacturer specifications. The Contactor shall maintain the Biomedical Test Equipment within the original equipment manufacturer (OEM) specifications, in like new or better condition.</p>\n\n<p>NOTE: Under no circumstances shall the Contractor assume a verbal or written inquiry as authorization to provide services not specifically identified in this PWS.</p>\n\n<p>Service deemed outside of the scope of this requirement.&nbsp; Defects in equipment or repairs beyond normal preventative and corrective maintenance are deemed to be outside the scope of this requirement.&nbsp; In these incidences, the Contractor shall immediately notify Contracting Officer, Contracting Officer Representative (COR), and Chief Biomedical Repair Tech (BMET) in writing and a written cost estimate for the repair/replacement.</p>\n\n<p>This notice of intent is not a request for competitive proposals. Sources interested in responding to this notice are required to submit a capability statement that includes management and technical data and price information, in sufficient detail and with convincing evidence that clearly demonstrates the capability to perform the required work. Capability statements shall not exceed five (8.5 x 11 inch) pages using a font size no smaller than 10-point. All capability statements received by the due date of this notice will be considered by the Government. A request for documentation or additional information will not be considered as an affirmative response or acceptance of the capability statement. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement or to proceed with a sole source contract. Capability statements should also include the business size and cage code.</p>\n\n<p>Capability statements are due by 2:00 PM Local Time, 07 July 2026. Capability statements shall be submitted by e-mail ONLY as a Microsoft Word or Adobe PDF attachment to the following address: curtis.e.cardoza.civ@us.navy.mil.</p>","origin":"detail"},"contacts":null,"place_of_performance":{"zip":"23501","state":{"code":"VA","name":"Virginia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":null,"naics_codes":["621511"],"award":null,"attachments":[{"resource_id":"9987bf5da93e4fdc9e866ed7a92e12f7","name":"Notice of Intent to Sole Source - Southeastern.docx","kind":"file","mime_type":".docx","size_bytes":39294,"posted_at":"2026-06-26T15:34:10.690Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9987bf5da93e4fdc9e866ed7a92e12f7/download","mirrored":false}],"awards":[],"related":[],"similar_open":[{"key":"36C25027Q0113","latest_notice_id":"30f6d444e0f641e5b23d5b4c1ec5a384","title":"Q301--Prostate Reference Lab Testing Services","solicitation_number":"36C25027Q0113","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"621511","psc":"Q301","set_aside":null,"state":"OH","county":"39049","county_name":"Franklin County","city":"3918000","city_name":"Columbus","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26326R0063","latest_notice_id":"d70c843cc4d84fd69905d2e17ce78771","title":"NWI Offsite Pathology Services","solicitation_number":"36C26326R0063","notice_type":"o","first_type":"o","first_posted":"2026-10-09","last_posted":"2026-11-20","notices":5,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"621511","psc":"Q515","set_aside":"SBA","state":"NE","county":"31055","county_name":"Douglas County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N0018927R0001","latest_notice_id":"63940568a9a1466e83c3068f740e6182","title":"NBIMC Bloodborne Services","solicitation_number":"N0018927R0001","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T21:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00189","office_name":"NAVSUP FLT LOG CTR NORFOLK","naics":"621511","psc":"Q301","set_aside":null,"state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"DEFENSE SERUM REPOSITORY (DODSR) IN SILVER SPRING, MARYLAND","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":5,"indexable":false}