{"canonical":"https://sealedbidder.com/opportunities/ht942626pe028","key":"HT942626PE028","url":"https://sealedbidder.com/opportunities/ht942626pe028","title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","solicitation_number":"HT942626PE028","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":null,"first_posted":"2026-07-16","last_posted":"2026-07-16","department":"DEPT OF DEFENSE","subagency":"DEFENSE HEALTH AGENCY (DHA)","office":"DEFENSE HEALTH AGENCY","naics":"334516","psc":"6640","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24025","place_county_name":"Harford County","place_city":null,"place_city_name":null,"winner":"MEDTEC BIOLAB, INC.","award_amount":"82500.00","publications":[{"notice_id":"8261a2975622420e87f78c08fb306658","title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","solicitation_number":"HT942626PE028","notice_type":"a","base_type":"s","posted":"2026-07-16","posted_at":"2026-07-16T19:53:27.283Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-07-31","removed_at":null,"award_number":"HT942626PE028","awardee_name":"MEDTEC BIOLAB, INC.","amount":"82500.00","link_sam":"https://sam.gov/workspace/contract/opp/8261a2975622420e87f78c08fb306658/view","enriched":true,"history":[{"index":6,"title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T19:53:27.283Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8261a2975622420e87f78c08fb306658","solicitation_number":"HT942626PE028","related_opportunity_id":"8815decbc2e144d2ba12e285f261c0f0"},{"index":3,"title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-13T15:18:17.651Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8815decbc2e144d2ba12e285f261c0f0","solicitation_number":"PANDHA-26-P-0000-039389"}]}],"latest_notice_id":"8261a2975622420e87f78c08fb306658","first_type":"a","notices":[{"award":{"date":"2026-07-16","amount":"82500.00","number":"HT942626PE028","awardee":{"raw":"MEDTEC BIOLAB, INC. Durham NC 27705 USA","uei":"QYG6BZ5CG396","cage":"1LHZ6","name":"MEDTEC BIOLAB, INC.","location":{"zip":"27705","city":{"code":"19000","name":"Durham"},"state":{"code":"NC","name":"North Carolina"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-07-16","posted_at":"2026-07-16T19:53:27.283Z","award_date":"2026-07-16","created_at":"2026-07-16T19:30:04.464Z","modified_at":"2026-07-31T05:06:25.353Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/8261a2975622420e87f78c08fb306658/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","agency":{"office":{"code":"HT9426","name":"DEFENSE HEALTH AGENCY"},"subtier":{"code":"97DH","name":"DEFENSE HEALTH AGENCY (DHA)"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"21702","city":"FORT DETRICK","state":"MD","country":"USA"},"organization_id":"500196158","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-31","archive_type":"auto15"},"history":[{"index":6,"title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T19:53:27.283Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8261a2975622420e87f78c08fb306658","solicitation_number":"HT942626PE028","related_opportunity_id":"8815decbc2e144d2ba12e285f261c0f0"},{"index":3,"title":"Air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-13T15:18:17.651Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8815decbc2e144d2ba12e285f261c0f0","solicitation_number":"PANDHA-26-P-0000-039389"}],"contacts":[{"name":"Ken Grenier","role":"primary","email":"kenneth.e.grenier2.civ@health.mil"},{"name":"Jesse Nisley","role":"secondary","email":"jesse.d.nisley.civ@health.mil"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"8261a2975622420e87f78c08fb306658","lineage_id":"8815decbc2e144d2ba12e285f261c0f0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T02:07:38.283129992Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"27d00dcafbd029eba8852966e48955fd3e47ea17a5e0a6c6eabd7e9f02bc4545","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T02:07:38.283129992Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>USAMRICD requires the acquisition of an air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty. &nbsp;Acquisition of a high-performance ALI exposure system is needed to provide controlled environmental chamber with aerosol exposure capabilities, including gas, vapor, particulate, and mixed aerosols, to human ALI models (ciliated airway, alveolar/endothelial deep lung, commercial pulmonary tissue, precision cut lung slices) of the human respiratory tract. The ALI exposure system required will need temperature and humidity control and real-time monitoring, modular, versatile, and flexible design to adapt system to match test article exposure characteristics, ability to hold different ALI insert and tissue types, use electrostatic deposition to maximize particle deposition on tissue models, expose between 6 &ndash; 24 samples at one time to one or multiple doses, provide high quality and repeatable data comparable to published scientific literature, compatibility to interface with different atmosphere generation systems, provide real-time deposited mass dose data to ALI models, and provide easy maintenance, cleaning, and turnaround times for next experiment. The requirement will also need any associated sample holders and real-time monitoring software supporting the specialized software and equipment. &nbsp;The CelTox Sampler system from MEDTEC BIOLAB, INC. is the only identified ALI exposure system capable of meeting the minimal essential characteristics (MEC).</p>","text":"USAMRICD requires the acquisition of an air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty. Acquisition of a high-performance ALI exposure system is needed to provide controlled environmental chamber with aerosol exposure capabilities, including gas, vapor, particulate, and mixed aerosols, to human ALI models (ciliated airway, alveolar/endothelial deep lung, commercial pulmonary tissue, precision cut lung slices) of the human respiratory tract. The ALI exposure system required will need temperature and humidity control and real-time monitoring, modular, versatile, and flexible design to adapt system to match test article exposure characteristics, ability to hold different ALI insert and tissue types, use electrostatic deposition to maximize particle deposition on tissue models, expose between 6 – 24 samples at one time to one or multiple doses, provide high quality and repeatable data comparable to published scientific literature, compatibility to interface with different atmosphere generation systems, provide real-time deposited mass dose data to ALI models, and provide easy maintenance, cleaning, and turnaround times for next experiment. The requirement will also need any associated sample holders and real-time monitoring software supporting the specialized software and equipment. The CelTox Sampler system from MEDTEC BIOLAB, INC. is the only identified ALI exposure system capable of meeting the minimal essential characteristics (MEC).","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"HT942626PE028","place_of_performance":{"zip":"21010","city":{"code":"35825","name":"Gunpowder"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":null,"due_date":null,"closes_at":null,"awardable":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9426","office_name":"DEFENSE HEALTH AGENCY","state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"QYG6BZ5CG396","amount":"82500.00","linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-29T02:10:09.077374Z","principal_notice_id":"8261a2975622420e87f78c08fb306658","description":{"text":"USAMRICD requires the acquisition of an air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty. Acquisition of a high-performance ALI exposure system is needed to provide controlled environmental chamber with aerosol exposure capabilities, including gas, vapor, particulate, and mixed aerosols, to human ALI models (ciliated airway, alveolar/endothelial deep lung, commercial pulmonary tissue, precision cut lung slices) of the human respiratory tract. The ALI exposure system required will need temperature and humidity control and real-time monitoring, modular, versatile, and flexible design to adapt system to match test article exposure characteristics, ability to hold different ALI insert and tissue types, use electrostatic deposition to maximize particle deposition on tissue models, expose between 6 – 24 samples at one time to one or multiple doses, provide high quality and repeatable data comparable to published scientific literature, compatibility to interface with different atmosphere generation systems, provide real-time deposited mass dose data to ALI models, and provide easy maintenance, cleaning, and turnaround times for next experiment. The requirement will also need any associated sample holders and real-time monitoring software supporting the specialized software and equipment. The CelTox Sampler system from MEDTEC BIOLAB, INC. is the only identified ALI exposure system capable of meeting the minimal essential characteristics (MEC).","html":"<p>USAMRICD requires the acquisition of an air-liquid interface (ALI) exposure system with installation and training post award and one year of warranty. &nbsp;Acquisition of a high-performance ALI exposure system is needed to provide controlled environmental chamber with aerosol exposure capabilities, including gas, vapor, particulate, and mixed aerosols, to human ALI models (ciliated airway, alveolar/endothelial deep lung, commercial pulmonary tissue, precision cut lung slices) of the human respiratory tract. The ALI exposure system required will need temperature and humidity control and real-time monitoring, modular, versatile, and flexible design to adapt system to match test article exposure characteristics, ability to hold different ALI insert and tissue types, use electrostatic deposition to maximize particle deposition on tissue models, expose between 6 &ndash; 24 samples at one time to one or multiple doses, provide high quality and repeatable data comparable to published scientific literature, compatibility to interface with different atmosphere generation systems, provide real-time deposited mass dose data to ALI models, and provide easy maintenance, cleaning, and turnaround times for next experiment. The requirement will also need any associated sample holders and real-time monitoring software supporting the specialized software and equipment. &nbsp;The CelTox Sampler system from MEDTEC BIOLAB, INC. is the only identified ALI exposure system capable of meeting the minimal essential characteristics (MEC).</p>","origin":"detail"},"contacts":[{"name":"Ken Grenier","role":"primary","email":"kenneth.e.grenier2.civ@health.mil"},{"name":"Jesse Nisley","role":"secondary","email":"jesse.d.nisley.civ@health.mil"}],"place_of_performance":{"zip":"21010","city":{"code":"35825","name":"Gunpowder"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"21702","city":"FORT DETRICK","state":"MD","country":"USA"},"naics_codes":["334516"],"award":{"date":"2026-07-16","amount":"82500.00","number":"HT942626PE028","awardee":{"raw":"MEDTEC BIOLAB, INC. Durham NC 27705 USA","uei":"QYG6BZ5CG396","cage":"1LHZ6","name":"MEDTEC BIOLAB, INC.","location":{"zip":"27705","city":{"code":"19000","name":"Durham"},"state":{"code":"NC","name":"North Carolina"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"6209d7b24d0e48e888d3542136ba0bd4","name":"MEC_Final.docx","kind":"file","mime_type":".docx","size_bytes":25964,"posted_at":"2026-07-16T19:53:27.283Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6209d7b24d0e48e888d3542136ba0bd4/download","mirrored":false}],"awards":[],"related":[{"key":"PANDHA26P0000045517","latest_notice_id":"7923a0ececfa4368bbb5088e7b8cb061","title":"SOURCES SOUGHT NOTICE/REQUEST FOR INFORMATION (RFI) for Thermal Foot Manikin Repair Services and Software update","solicitation_number":"PANDHA-26-P-0000_045517","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9426","office_name":"DEFENSE HEALTH AGENCY","naics":"811210","psc":"J066","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"REQUIRED SERVICES, PLEASE PROVIDE A WHITE PAPER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"PANDHA27P0000053236","latest_notice_id":"5f951088f4804480b06dac3326eb9a34","title":"SOURCES SOUGHT NOTICE/REQUEST FOR INFORMATION (RFI) for Siemens Reagents and Consumables","solicitation_number":"PANDHA-27-P-0000__053236","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-23","notices":2,"due_at":"2026-12-04T18:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9426","office_name":"DEFENSE HEALTH AGENCY","naics":"325413","psc":"6550","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6550)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"DHACITITRAINING","latest_notice_id":"9d2405bb70a24144b8ef27cda99ab47b","title":"Notice of Intent to Sole Source access to online research and compliance and regulatory training provided by Biomedical Research Alliance of New York LLC (BRANY)","solicitation_number":"DHA_CITI_Training","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T19:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9426","office_name":"DEFENSE HEALTH AGENCY","naics":"611430","psc":"AN11","set_aside":null,"state":"MD","county":"24021","county_name":"Frederick County","city":"2430325","city_name":"Frederick","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":53,"indexable":false}