Sources sought
Operations, Maintenance, and Repair of the International Outfall Interceptor (IOI) Nogales, Arizona
FY263281036
International Boundary and Water Commission: US-Mexico, Internat. Boundary and Water Comm.. Sewage Treatment Facilities.
Response deadline
June 18, 2026 at 7:00 PM EDT
Closed 160 days ago. Posted June 4, 2026. Scheduled to archive July 3, 2026.
Get the next one like this from International Boundary and Water Commission: US-Mexico by email, the day it is posted.Find my opportunities
This one closed in 2026
4 like it are open now in sewage treatment facilities
- GRCA 257282 - Replace Wastewater Plant at South Ri
National Park Service, DSC Contracting Services Division
SolicitationNAICS 221320Arizona140P2026R0101Closes in 23 daysDec 18 - Station Grand Isle Sewage Treatment
US Coast Guard, Base New Orleans
SolicitationSmall businessNAICS 221320Grand Isle, LA70Z02927QNEWO0P01Due tomorrowNov 26 - Operations and Maintenance (O&M) Services for the SBIWTP
International Boundary and Water Commission: US-Mexico, Internat. Boundary and Water Comm.
SolicitationNAICS 221320California191BWC26R0009Closes in 42 daysJan 6, 2027
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 221320 (sewage treatment facilities), means no more than $35 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation has been published under this number yet. The sources sought of June 4, 2026 is the earliest notice of the purchase.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
DRAFT SOURCES SOUGHT NOTICE
International Boundary and Water Commission, U.S. Section (USIBWC)
Operations, Maintenance, and Repair of the International Outfall Interceptor (IOI)
Nogales, Arizona
1. PURPOSE
This Sources Sought notice is issued solely for market research and information gathering in accordance with FAR Part 10. This is not a solicitation, does not constitute a Request for Quote (RFQ) or Request for Proposal (RFP), and shall not be construed as a commitment by the Government. No reimbursement will be made for any costs associated with responding to this notice.
The USIBWC is seeking to identify qualified contractors capable of performing Operations, Maintenance, and Repair (OMR) Services for the International Outfall Interceptor (IOI) located in Santa Cruz County, Rio Rico, Arizona, as specified in the Performance Work Statement (PWS) for the Nogales IOI system.
2. PROJECT BACKGROUND
The IOI conveys raw sewage originating from Nogales, Sonora (MX), Nogales, AZ, and Rio Rico, AZ to the Nogales International Wastewater Treatment Plant (NIWTP). The pipeline spans approximately 46,600 linear feet and includes 110 manholes. The PWS describes a comprehensive scope including annual inspections, smoke testing, manhole cleaning, emergency response, CMMS operation, repairs, regulatory reporting, and cybersecurity requirements for associated systems.
The anticipated contract structure is a five‑year period of performance (Base Year plus four Option Years).
3. SCOPE OF REQUIRED CAPABILITIES
Interested contractors must demonstrate capability to perform, at a minimum:
Operations & Maintenance
• Annual CCTV/Sonar inspection of entire 46,600‑ft pipeline and 110 manholes
• Smoke testing twice per year
• Routine and as‑needed cleaning; sediment, debris, and obstruction removal
• Waste disposal in accordance with Federal, state, and local regulations
• Vegetation management
• Fats, Oils, Grease (FOG), odor, and corrosion control programs
• Flow and level monitoring (15‑minute intervals), data integration with CMMS/GIS
• Operation of an IOI‑dedicated Arizona Grade IV Certified Wastewater Collection Operator onsite
• Welding shut manholes for security (tack weld specification per PWS)
• Full implementation and operation of a Computerized Maintenance Management System (CMMS) meeting FISMA High, FedRAMP High, and NIST SP 800‑171 requirements for CUI/SCADA environments
Repairs and Emergency Response
• 24/7 monitoring and rapid emergency response
• SSO Response Plan with 60‑minute dispatch and full ADEQ compliance
• Rain‑event clean‑out within 48 hours
• Pipeline and manhole repairs within 24 hours of discovery or immediate bypass implementation
• Replacement of covers, ladders, joints, seals
• Infiltration/inflow monitoring and flood‑readiness planning
Safety, Environmental, and Regulatory Requirements
• OSHA 29 CFR 1910/1926 compliance
• Arizona Department of Environmental Quality (ADEQ) coordination
• Hazardous materials evaluation and disposal (lead/asbestos, as applicable)
• Site security and coordination with DHS/CBP when required
• Compliance with applicable Public Laws, Federal standards, and building codes to the maximum extent practicable
4. SUBMISSION REQUIREMENTS
Interested firms must submit a capability statement (no more than 10 pages) addressing the following:
A. Company Information
• Name, address, UEI, CAGE code
• Point of Contact (name, title, phone, email)
• Business size/status under NAICS 221320 – Sewage Treatment Facilities
• Socioeconomic category (8(a), HUBZone, SDVOSB, WOSB, etc.)
B. Relevant Experience
• Demonstrated experience (within the past 5 years) performing O&M and emergency repair of wastewater collection systems of similar size, complexity, and regulatory sensitivity
• Experience with CMMS implementation for wastewater/collection systems
• Experience meeting NIST SP 800‑53 High, NIST SP 800‑171 Rev. 3, FIPS 140‑3, and FedRAMP High environments (if proposing cloud‑based CMMS)
C. Key Personnel
• Qualifications and certifications of proposed IOI Operator (Arizona Grade IV)
• Wastewater operations personnel and emergency response staffing capabilities
D. Technical Approach Overview
• Preliminary staffing approach
• Proposal for meeting the PWS inspection, testing, and reporting requirements
• Emergency response strategy (SSO, storm events, vulnerabilities beneath wash/creek areas)
E. Past Performance
• Contract numbers, periods of performance, dollar values, brief descriptions
• Points of contact for verification
F. Additional Input
Industry feedback is invited on:
• Availability of qualified firms
• Recommended contract type (Firm Fixed Price vs Hybrid CLIN structure)
• Potential barriers to competition
• Comments on CMMS cybersecurity requirements
5. RESPONSE INSTRUCTIONS
Responses should be submitted via email to:
Suzette.Smith@IBWC.gov and PhilipJohnson@ibwc.gov
Subject line: “Sources Sought – Nogales IOI OMR Services”
Deadline: 6/18/2026
No telephone inquiries will be accepted.
6. DISCLAIMER
This notice is issued for market research only, in accordance with FAR 10.002.
Responses do not constitute offers and will not be used to award a contract.
Respondents may be contacted for clarification or additional information.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Draft_PWS_Nogales_IOI_Operation_Maintenance_Repairs (2).pdf450 KB, June 4, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 4, 2026
Sources sought
Due June 18, 2026 at 7:00 PM EDT. SAM.gov, notice 2f66e09e6d204bd1b627efb792be06eb
1 revision on SAM
- June 4, 2026: publish, sources sought
Points of contact
- Philip Johnsonphilip.johnson@ibwc.gov
- Suzette Smithsuzette.smith@ibwc.gov