{"canonical":"https://sealedbidder.com/opportunities/fxsb266837","key":"FXSB266837","url":"https://sealedbidder.com/opportunities/fxsb266837","title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","solicitation_number":"FXSB-26-6837","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-10T21:00:00Z","first_posted":"2026-03-30","last_posted":"2026-04-03","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA5000 673 CONS PKB","naics":"238160","psc":"Z1JZ","set_aside":"SBA","place_state":"AK","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"02020","place_county_name":"Anchorage Municipality","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"767eebf0fb93495bb1730dd0b638b167","title":"Repair Replace Hangar Roof B11525","solicitation_number":"FXSB-26-6837","notice_type":"r","base_type":"r","posted":"2026-03-30","posted_at":"2026-03-30T19:46:27.598Z","due_at":"2026-04-07T21:00:00Z","due_date":"2026-04-07","cancelled":false,"archived":true,"archive_date":"2026-04-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/767eebf0fb93495bb1730dd0b638b167/view","enriched":true,"history":[{"index":4,"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T22:00:55.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6875ec42dd9c44e497d25a21b908fe0b","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":2,"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T21:55:00.875Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"9e168bef1d30414b8a5a1f0065c9fdc1","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":1,"title":"Repair Replace Hangar Roof B11525","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T19:46:27.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"767eebf0fb93495bb1730dd0b638b167","solicitation_number":"FXSB-26-6837"}]},{"notice_id":"6875ec42dd9c44e497d25a21b908fe0b","title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","solicitation_number":"FXSB-26-6837","notice_type":"r","base_type":"r","posted":"2026-04-03","posted_at":"2026-04-03T22:00:55.129Z","due_at":"2026-04-10T21:00:00Z","due_date":"2026-04-10","cancelled":false,"archived":true,"archive_date":"2026-04-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6875ec42dd9c44e497d25a21b908fe0b/view","enriched":true,"history":[{"index":4,"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T22:00:55.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6875ec42dd9c44e497d25a21b908fe0b","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":2,"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T21:55:00.875Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"9e168bef1d30414b8a5a1f0065c9fdc1","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":1,"title":"Repair Replace Hangar Roof B11525","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T19:46:27.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"767eebf0fb93495bb1730dd0b638b167","solicitation_number":"FXSB-26-6837"}]},{"notice_id":"9e168bef1d30414b8a5a1f0065c9fdc1","title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","solicitation_number":"FXSB-26-6837","notice_type":"r","base_type":"r","posted":"2026-04-03","posted_at":"2026-04-03T21:55:00.875Z","due_at":"2026-04-10T21:00:00Z","due_date":"2026-04-10","cancelled":false,"archived":true,"archive_date":"2026-04-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9e168bef1d30414b8a5a1f0065c9fdc1/view","enriched":true,"history":[{"index":4,"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T22:00:55.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6875ec42dd9c44e497d25a21b908fe0b","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":2,"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T21:55:00.875Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"9e168bef1d30414b8a5a1f0065c9fdc1","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":1,"title":"Repair Replace Hangar Roof B11525","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T19:46:27.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"767eebf0fb93495bb1730dd0b638b167","solicitation_number":"FXSB-26-6837"}]}],"latest_notice_id":"9e168bef1d30414b8a5a1f0065c9fdc1","first_type":"r","notices":[{"dates":{"posted":"2026-03-30","posted_at":"2026-03-30T19:46:27.598Z","created_at":"2026-03-30T19:22:17.136Z","modified_at":"2026-04-25T04:04:30.949Z","response_deadline":{"raw":"2026-04-07T13:00:00-08:00","utc":"2026-04-07T21:00:00Z","date":"2026-04-07","time":"13:00:00","timezone":"America/Anchorage","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/767eebf0fb93495bb1730dd0b638b167/view"},"naics":{"codes":["238160"],"primary":"238160"},"title":"Repair Replace Hangar Roof B11525","agency":{"office":{"code":"FA5000","name":"FA5000 673 CONS PKB"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-2501","city":"JBER","state":"AK","country":"USA"},"organization_id":"100001255","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-22","archive_type":"auto15"},"history":[{"index":4,"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T22:00:55.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6875ec42dd9c44e497d25a21b908fe0b","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":2,"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T21:55:00.875Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"9e168bef1d30414b8a5a1f0065c9fdc1","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":1,"title":"Repair Replace Hangar Roof B11525","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T19:46:27.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"767eebf0fb93495bb1730dd0b638b167","solicitation_number":"FXSB-26-6837"}],"contacts":[{"name":"Robin Cole-Barden","role":"primary","email":"robin.cole-barden.1@us.af.mil"},{"name":"Christopher Nelson","role":"secondary","email":"Christopher.nelson.70@us.af.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"767eebf0fb93495bb1730dd0b638b167","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"767eebf0fb93495bb1730dd0b638b167","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T01:50:09.784087089Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"f2235d85ff6466e9287187f054b2002d72a642adeda5b9ad6bd2886532f12b3c","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T01:50:09.784087089Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that&rsquo;s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>Contractor shall provide all labor, materials, equipment, hardware, software and programming necessary to provide fully functional repairs for Tank Farms 3 and 4 in accordance with (IAW) the SOW and as detailed in drawings and specifications</p>","text":"Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that’s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.\n\nContractor shall provide all labor, materials, equipment, hardware, software and programming necessary to provide fully functional repairs for Tank Farms 3 and 4 in accordance with (IAW) the SOW and as detailed in drawings and specifications","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"FXSB-26-6837","place_of_performance":{"zip":"99506","city":{"code":"0","name":"JBER"},"state":{"code":"AK","name":"Alaska"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z1JZ"},{"dates":{"posted":"2026-04-03","posted_at":"2026-04-03T22:00:55.129Z","created_at":"2026-04-03T21:57:50.486Z","modified_at":"2026-04-25T04:04:30.949Z","response_deadline":{"raw":"2026-04-10T13:00:00-08:00","utc":"2026-04-10T21:00:00Z","date":"2026-04-10","time":"13:00:00","timezone":"America/Anchorage","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6875ec42dd9c44e497d25a21b908fe0b/view"},"naics":{"codes":["238160"],"primary":"238160"},"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","agency":{"office":{"code":"FA5000","name":"FA5000 673 CONS PKB"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-2501","city":"JBER","state":"AK","country":"USA"},"organization_id":"100001255","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-25","archive_type":"auto15"},"history":[{"index":4,"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T22:00:55.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6875ec42dd9c44e497d25a21b908fe0b","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":2,"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T21:55:00.875Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"9e168bef1d30414b8a5a1f0065c9fdc1","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":1,"title":"Repair Replace Hangar Roof B11525","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T19:46:27.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"767eebf0fb93495bb1730dd0b638b167","solicitation_number":"FXSB-26-6837"}],"contacts":[{"name":"Robin Cole-Barden","role":"primary","email":"robin.cole-barden.1@us.af.mil"},{"name":"Christopher Nelson","role":"secondary","email":"Christopher.nelson.70@us.af.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"6875ec42dd9c44e497d25a21b908fe0b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"767eebf0fb93495bb1730dd0b638b167","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T03:37:41.093254134Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"03aa4b06b91895d0059ded10c603ebcba500b1235446af1e9568232d4f2d9b1d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T03:37:41.093254134Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR</p>\n\n<p><strong>INFORMATIONAL AND PLANNING PURPOSES ONLY! </strong>This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement.</p>\n\n<p>This Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP.</p>\n\n<p>The Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude.</p>\n\n<p>The anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M.</p>\n\n<p>Business Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses.</p>\n\n<p>REQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525</p>\n\n<p>Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that&rsquo;s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>REQUIREMENT: FXSB 26-6670&nbsp; Repair Replace Hangar 3 Roof B10571&nbsp; &nbsp;&nbsp;</p>\n\n<p>Building 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high barrel roof section that&rsquo;s approximately 50,000 SF. Additionally there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>Refer to Government&rsquo;s 35% Design Drawings for roof sections identified above in which work shall take place. *Note: The North lower lean-to roof work shall be completed first. Contractor&rsquo;s phasing plan shall have this portion of the roof as the starting point with all other roof work proceeding outward and over the barrel to the south lower lean-to roof.</p>\n\n<p>All existing HVAC equipment shall be removed during demolition and re-installed to the same location during installation of the new roofing membrane/system. Existing equipment curbs shall be demoed and replaced with new equipment curbs. Location shall remain. Remove and demolish existing roof access hatches that shall be replaced with new. Roof access hatch curbs shall also be demoed and replaced with new curbs. Location shall remain. Contractor shall confirm phasing plan during the design phase of the project detail with the 673rd Project Manager and Inspector as design progresses.</p>\n\n<p>REQUIREMENT: FXSB 26-7337 Repair Replace Hangar 1 Roof B11551</p>\n\n<p>The requirement package is still being generated; however, the magnitude and scope are similar to the&nbsp;above two referenced requirements.&nbsp; &nbsp; &nbsp;</p>\n\n<p>The Contractor shall furnish all design, parts, labor, equipment, supplies, materials, appliances, transportation, and perform all work (including work of an incidental nature), complete, in strict accordance with the scope of work, drawings and subject to the terms and conditions of the contract.</p>\n\n<p><strong>CAPABILITY STATEMENT</strong>: Firms responding to this Sources Sought notice are requested to provide a capability statement. At a minimum, the capability statement must include:</p>\n\n<ul>\n\t<li>Company Name</li>\n\t<li>Point of Contact Name</li>\n\t<li>Unique Entity Number (UEI) and CAGE Code</li>\n\t<li>Small Business socio-economic status under NAICS 238160</li>\n\t<li>Brief descriptions of recent and relevant projects for tasks similar to those in the draft SOW with the associated agency&rsquo;s name, contract number (if applicable), and agency point of contact</li>\n\t<li>If work was conducted under a teaming agreement, please annotate if work was performed as the prime or the subcontractor</li>\n</ul>\n\n<p>Capability statements must be submitted via e-mail to the POCs listed below no later than 1:00 PM Local Time on 10 April 26. Telephone responses will not be accepted.</p>\n\n<p>Name: Robin Cole-Barden</p>\n\n<p>Email: Robin.Cole-Barden.1@us.af.mil</p>\n\n<p>Name: Christopher Nelson</p>\n\n<p>Email: Christopher.Nelson.70@us.af.mil</p>\n\n<p>Future information about this acquisition, including issuance of a Request for Proposal or an Invitation for Bid, or applicable amendments, will be issued through SAM.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.</p>\n\n<p>All firms should be registered in the System for Award Management (SAM) located at http://www.sam.gov.</p>","text":"SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR\n\nINFORMATIONAL AND PLANNING PURPOSES ONLY! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement.\n\nThis Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP.\n\nThe Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude.\n\nThe anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M.\n\nBusiness Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses.\n\nREQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525\n\nBuilding 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that’s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.\n\nREQUIREMENT: FXSB 26-6670 Repair Replace Hangar 3 Roof B10571\n\nBuilding 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high barrel roof section that’s approximately 50,000 SF. Additionally there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.\n\nRefer to Government’s 35% Design Drawings for roof sections identified above in which work shall take place. *Note: The North lower lean-to roof work shall be completed first. Contractor’s phasing plan shall have this portion of the roof as the starting point with all other roof work proceeding outward and over the barrel to the south lower lean-to roof.\n\nAll existing HVAC equipment shall be removed during demolition and re-installed to the same location during installation of the new roofing membrane/system. Existing equipment curbs shall be demoed and replaced with new equipment curbs. Location shall remain. Remove and demolish existing roof access hatches that shall be replaced with new. Roof access hatch curbs shall also be demoed and replaced with new curbs. Location shall remain. Contractor shall confirm phasing plan during the design phase of the project detail with the 673rd Project Manager and Inspector as design progresses.\n\nREQUIREMENT: FXSB 26-7337 Repair Replace Hangar 1 Roof B11551\n\nThe requirement package is still being generated; however, the magnitude and scope are similar to the above two referenced requirements.\n\nThe Contractor shall furnish all design, parts, labor, equipment, supplies, materials, appliances, transportation, and perform all work (including work of an incidental nature), complete, in strict accordance with the scope of work, drawings and subject to the terms and conditions of the contract.\n\nCAPABILITY STATEMENT: Firms responding to this Sources Sought notice are requested to provide a capability statement. At a minimum, the capability statement must include:\n\n• Company Name\n\n• Point of Contact Name\n\n• Unique Entity Number (UEI) and CAGE Code\n\n• Small Business socio-economic status under NAICS 238160\n\n• Brief descriptions of recent and relevant projects for tasks similar to those in the draft SOW with the associated agency’s name, contract number (if applicable), and agency point of contact\n\n• If work was conducted under a teaming agreement, please annotate if work was performed as the prime or the subcontractor\n\nCapability statements must be submitted via e-mail to the POCs listed below no later than 1:00 PM Local Time on 10 April 26. Telephone responses will not be accepted.\n\nName: Robin Cole-Barden\n\nEmail: Robin.Cole-Barden.1@us.af.mil\n\nName: Christopher Nelson\n\nEmail: Christopher.Nelson.70@us.af.mil\n\nFuture information about this acquisition, including issuance of a Request for Proposal or an Invitation for Bid, or applicable amendments, will be issued through SAM.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.\n\nAll firms should be registered in the System for Award Management (SAM) located at http://www.sam.gov.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"FXSB-26-6837","place_of_performance":{"zip":"99506","city":{"code":"0","name":"JBER"},"state":{"code":"AK","name":"Alaska"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z1JZ"},{"dates":{"posted":"2026-04-03","posted_at":"2026-04-03T21:55:00.875Z","created_at":"2026-04-03T21:11:37.141Z","modified_at":"2026-04-25T04:04:30.949Z","response_deadline":{"raw":"2026-04-10T13:00:00-08:00","utc":"2026-04-10T21:00:00Z","date":"2026-04-10","time":"13:00:00","timezone":"America/Anchorage","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9e168bef1d30414b8a5a1f0065c9fdc1/view"},"naics":{"codes":["238160"],"primary":"238160"},"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","agency":{"office":{"code":"FA5000","name":"FA5000 673 CONS PKB"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-2501","city":"JBER","state":"AK","country":"USA"},"organization_id":"100001255","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-25","archive_type":"auto15"},"history":[{"index":4,"title":"Repair Replace Roof B11525, Roof B10571 and Roof B11551","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T22:00:55.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6875ec42dd9c44e497d25a21b908fe0b","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":2,"title":"Repair Replace Roof B11525, Roof B10471 and Roof B11551","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T21:55:00.875Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"modify","opportunity_id":"9e168bef1d30414b8a5a1f0065c9fdc1","solicitation_number":"FXSB-26-6837","parent_opportunity_id":"767eebf0fb93495bb1730dd0b638b167"},{"index":1,"title":"Repair Replace Hangar Roof B11525","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T19:46:27.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"767eebf0fb93495bb1730dd0b638b167","solicitation_number":"FXSB-26-6837"}],"contacts":[{"name":"Robin Cole-Barden","role":"primary","email":"robin.cole-barden.1@us.af.mil"},{"name":"Christopher Nelson","role":"secondary","email":"Christopher.nelson.70@us.af.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"9e168bef1d30414b8a5a1f0065c9fdc1","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"767eebf0fb93495bb1730dd0b638b167","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T03:43:57.367970534Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"a993582b0b14811037a85e63e5c46e97002119dbb7f9972e594cbb73be2fcc28","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T03:43:57.367970534Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR</p>\n\n<p><strong>INFORMATIONAL AND PLANNING PURPOSES ONLY! </strong>This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement.</p>\n\n<p>This Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP.</p>\n\n<p>The Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude.</p>\n\n<p>The anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M.</p>\n\n<p>Business Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses.</p>\n\n<p>REQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525</p>\n\n<p>Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that&rsquo;s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>REQUIREMENT: FXSB 26-6670&nbsp; Repair Replace Hangar 3 Roof B10571&nbsp; &nbsp;&nbsp;</p>\n\n<p>Building 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high barrel roof section that&rsquo;s approximately 50,000 SF. Additionally there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>Refer to Government&rsquo;s 35% Design Drawings for roof sections identified above in which work shall take place. *Note: The North lower lean-to roof work shall be completed first. Contractor&rsquo;s phasing plan shall have this portion of the roof as the starting point with all other roof work proceeding outward and over the barrel to the south lower lean-to roof.</p>\n\n<p>All existing HVAC equipment shall be removed during demolition and re-installed to the same location during installation of the new roofing membrane/system. Existing equipment curbs shall be demoed and replaced with new equipment curbs. Location shall remain. Remove and demolish existing roof access hatches that shall be replaced with new. Roof access hatch curbs shall also be demoed and replaced with new curbs. Location shall remain. Contractor shall confirm phasing plan during the design phase of the project detail with the 673rd Project Manager and Inspector as design progresses.</p>\n\n<p>REQUIREMENT: FXSB 26-7337 Repair Replace Hangar 1 Roof B11551</p>\n\n<p>The requirement package is still being generated; however, the magnitude and scope are similar to the&nbsp;above two referenced requirements.&nbsp; &nbsp; &nbsp;</p>\n\n<p>The Contractor shall furnish all design, parts, labor, equipment, supplies, materials, appliances, transportation, and perform all work (including work of an incidental nature), complete, in strict accordance with the scope of work, drawings and subject to the terms and conditions of the contract.</p>\n\n<p><strong>CAPABILITY STATEMENT</strong>: Firms responding to this Sources Sought notice are requested to provide a capability statement. At a minimum, the capability statement must include:</p>\n\n<ul>\n\t<li>Company Name</li>\n\t<li>Point of Contact Name</li>\n\t<li>Unique Entity Number (UEI) and CAGE Code</li>\n\t<li>Small Business socio-economic status under NAICS 238160</li>\n\t<li>Brief descriptions of recent and relevant projects for tasks similar to those in the draft SOW with the associated agency&rsquo;s name, contract number (if applicable), and agency point of contact</li>\n\t<li>If work was conducted under a teaming agreement, please annotate if work was performed as the prime or the subcontractor</li>\n</ul>\n\n<p>Capability statements must be submitted via e-mail to the POCs listed below no later than 1:00 PM Local Time on 10 April 26. Telephone responses will not be accepted.</p>\n\n<p>Name: Robin Cole-Barden</p>\n\n<p>Email: Robin.Cole-Barden.1@us.af.mil</p>\n\n<p>Name: Christopher Nelson</p>\n\n<p>Email: Christopher.Nelson.70@us.af.mil</p>\n\n<p>Future information about this acquisition, including issuance of a Request for Proposal or an Invitation for Bid, or applicable amendments, will be issued through SAM.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.</p>\n\n<p>All firms should be registered in the System for Award Management (SAM) located at http://www.sam.gov.</p>","text":"SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR\n\nINFORMATIONAL AND PLANNING PURPOSES ONLY! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement.\n\nThis Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP.\n\nThe Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude.\n\nThe anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M.\n\nBusiness Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses.\n\nREQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525\n\nBuilding 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that’s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.\n\nREQUIREMENT: FXSB 26-6670 Repair Replace Hangar 3 Roof B10571\n\nBuilding 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high barrel roof section that’s approximately 50,000 SF. Additionally there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.\n\nRefer to Government’s 35% Design Drawings for roof sections identified above in which work shall take place. *Note: The North lower lean-to roof work shall be completed first. Contractor’s phasing plan shall have this portion of the roof as the starting point with all other roof work proceeding outward and over the barrel to the south lower lean-to roof.\n\nAll existing HVAC equipment shall be removed during demolition and re-installed to the same location during installation of the new roofing membrane/system. Existing equipment curbs shall be demoed and replaced with new equipment curbs. Location shall remain. Remove and demolish existing roof access hatches that shall be replaced with new. Roof access hatch curbs shall also be demoed and replaced with new curbs. Location shall remain. Contractor shall confirm phasing plan during the design phase of the project detail with the 673rd Project Manager and Inspector as design progresses.\n\nREQUIREMENT: FXSB 26-7337 Repair Replace Hangar 1 Roof B11551\n\nThe requirement package is still being generated; however, the magnitude and scope are similar to the above two referenced requirements.\n\nThe Contractor shall furnish all design, parts, labor, equipment, supplies, materials, appliances, transportation, and perform all work (including work of an incidental nature), complete, in strict accordance with the scope of work, drawings and subject to the terms and conditions of the contract.\n\nCAPABILITY STATEMENT: Firms responding to this Sources Sought notice are requested to provide a capability statement. At a minimum, the capability statement must include:\n\n• Company Name\n\n• Point of Contact Name\n\n• Unique Entity Number (UEI) and CAGE Code\n\n• Small Business socio-economic status under NAICS 238160\n\n• Brief descriptions of recent and relevant projects for tasks similar to those in the draft SOW with the associated agency’s name, contract number (if applicable), and agency point of contact\n\n• If work was conducted under a teaming agreement, please annotate if work was performed as the prime or the subcontractor\n\nCapability statements must be submitted via e-mail to the POCs listed below no later than 1:00 PM Local Time on 10 April 26. Telephone responses will not be accepted.\n\nName: Robin Cole-Barden\n\nEmail: Robin.Cole-Barden.1@us.af.mil\n\nName: Christopher Nelson\n\nEmail: Christopher.Nelson.70@us.af.mil\n\nFuture information about this acquisition, including issuance of a Request for Proposal or an Invitation for Bid, or applicable amendments, will be issued through SAM.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.\n\nAll firms should be registered in the System for Award Management (SAM) located at http://www.sam.gov.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"FXSB-26-6837","place_of_performance":{"zip":"99506","city":{"code":"0","name":"JBER"},"state":{"code":"AK","name":"Alaska"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z1JZ"}],"due_at":"2026-04-10T21:00:00Z","due_date":"2026-04-10","closes_at":"2026-04-10T21:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5000","office_name":"FA5000 673 CONS PKB","state":"AK","county":"02020","county_name":"Anchorage Municipality","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-08T03:46:32.887903Z","principal_notice_id":"9e168bef1d30414b8a5a1f0065c9fdc1","description":{"text":"SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR\n\nINFORMATIONAL AND PLANNING PURPOSES ONLY! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement.\n\nThis Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP.\n\nThe Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude.\n\nThe anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M.\n\nBusiness Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses.\n\nREQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525\n\nBuilding 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that’s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.\n\nREQUIREMENT: FXSB 26-6670 Repair Replace Hangar 3 Roof B10571\n\nBuilding 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high barrel roof section that’s approximately 50,000 SF. Additionally there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.\n\nRefer to Government’s 35% Design Drawings for roof sections identified above in which work shall take place. *Note: The North lower lean-to roof work shall be completed first. Contractor’s phasing plan shall have this portion of the roof as the starting point with all other roof work proceeding outward and over the barrel to the south lower lean-to roof.\n\nAll existing HVAC equipment shall be removed during demolition and re-installed to the same location during installation of the new roofing membrane/system. Existing equipment curbs shall be demoed and replaced with new equipment curbs. Location shall remain. Remove and demolish existing roof access hatches that shall be replaced with new. Roof access hatch curbs shall also be demoed and replaced with new curbs. Location shall remain. Contractor shall confirm phasing plan during the design phase of the project detail with the 673rd Project Manager and Inspector as design progresses.\n\nREQUIREMENT: FXSB 26-7337 Repair Replace Hangar 1 Roof B11551\n\nThe requirement package is still being generated; however, the magnitude and scope are similar to the above two referenced requirements.\n\nThe Contractor shall furnish all design, parts, labor, equipment, supplies, materials, appliances, transportation, and perform all work (including work of an incidental nature), complete, in strict accordance with the scope of work, drawings and subject to the terms and conditions of the contract.\n\nCAPABILITY STATEMENT: Firms responding to this Sources Sought notice are requested to provide a capability statement. At a minimum, the capability statement must include:\n\n• Company Name\n\n• Point of Contact Name\n\n• Unique Entity Number (UEI) and CAGE Code\n\n• Small Business socio-economic status under NAICS 238160\n\n• Brief descriptions of recent and relevant projects for tasks similar to those in the draft SOW with the associated agency’s name, contract number (if applicable), and agency point of contact\n\n• If work was conducted under a teaming agreement, please annotate if work was performed as the prime or the subcontractor\n\nCapability statements must be submitted via e-mail to the POCs listed below no later than 1:00 PM Local Time on 10 April 26. Telephone responses will not be accepted.\n\nName: Robin Cole-Barden\n\nEmail: Robin.Cole-Barden.1@us.af.mil\n\nName: Christopher Nelson\n\nEmail: Christopher.Nelson.70@us.af.mil\n\nFuture information about this acquisition, including issuance of a Request for Proposal or an Invitation for Bid, or applicable amendments, will be issued through SAM.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.\n\nAll firms should be registered in the System for Award Management (SAM) located at http://www.sam.gov.","html":"<p>SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR</p>\n\n<p><strong>INFORMATIONAL AND PLANNING PURPOSES ONLY! </strong>This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement.</p>\n\n<p>This Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP.</p>\n\n<p>The Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude.</p>\n\n<p>The anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M.</p>\n\n<p>Business Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses.</p>\n\n<p>REQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525</p>\n\n<p>Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that&rsquo;s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>REQUIREMENT: FXSB 26-6670&nbsp; Repair Replace Hangar 3 Roof B10571&nbsp; &nbsp;&nbsp;</p>\n\n<p>Building 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high barrel roof section that&rsquo;s approximately 50,000 SF. Additionally there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.</p>\n\n<p>Refer to Government&rsquo;s 35% Design Drawings for roof sections identified above in which work shall take place. *Note: The North lower lean-to roof work shall be completed first. Contractor&rsquo;s phasing plan shall have this portion of the roof as the starting point with all other roof work proceeding outward and over the barrel to the south lower lean-to roof.</p>\n\n<p>All existing HVAC equipment shall be removed during demolition and re-installed to the same location during installation of the new roofing membrane/system. Existing equipment curbs shall be demoed and replaced with new equipment curbs. Location shall remain. Remove and demolish existing roof access hatches that shall be replaced with new. Roof access hatch curbs shall also be demoed and replaced with new curbs. Location shall remain. Contractor shall confirm phasing plan during the design phase of the project detail with the 673rd Project Manager and Inspector as design progresses.</p>\n\n<p>REQUIREMENT: FXSB 26-7337 Repair Replace Hangar 1 Roof B11551</p>\n\n<p>The requirement package is still being generated; however, the magnitude and scope are similar to the&nbsp;above two referenced requirements.&nbsp; &nbsp; &nbsp;</p>\n\n<p>The Contractor shall furnish all design, parts, labor, equipment, supplies, materials, appliances, transportation, and perform all work (including work of an incidental nature), complete, in strict accordance with the scope of work, drawings and subject to the terms and conditions of the contract.</p>\n\n<p><strong>CAPABILITY STATEMENT</strong>: Firms responding to this Sources Sought notice are requested to provide a capability statement. At a minimum, the capability statement must include:</p>\n\n<ul>\n\t<li>Company Name</li>\n\t<li>Point of Contact Name</li>\n\t<li>Unique Entity Number (UEI) and CAGE Code</li>\n\t<li>Small Business socio-economic status under NAICS 238160</li>\n\t<li>Brief descriptions of recent and relevant projects for tasks similar to those in the draft SOW with the associated agency&rsquo;s name, contract number (if applicable), and agency point of contact</li>\n\t<li>If work was conducted under a teaming agreement, please annotate if work was performed as the prime or the subcontractor</li>\n</ul>\n\n<p>Capability statements must be submitted via e-mail to the POCs listed below no later than 1:00 PM Local Time on 10 April 26. Telephone responses will not be accepted.</p>\n\n<p>Name: Robin Cole-Barden</p>\n\n<p>Email: Robin.Cole-Barden.1@us.af.mil</p>\n\n<p>Name: Christopher Nelson</p>\n\n<p>Email: Christopher.Nelson.70@us.af.mil</p>\n\n<p>Future information about this acquisition, including issuance of a Request for Proposal or an Invitation for Bid, or applicable amendments, will be issued through SAM.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.</p>\n\n<p>All firms should be registered in the System for Award Management (SAM) located at http://www.sam.gov.</p>","origin":"detail"},"contacts":[{"name":"Robin Cole-Barden","role":"primary","email":"robin.cole-barden.1@us.af.mil"},{"name":"Christopher Nelson","role":"secondary","email":"Christopher.nelson.70@us.af.mil"}],"place_of_performance":{"zip":"99506","city":{"code":"0","name":"JBER"},"state":{"code":"AK","name":"Alaska"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"99506-2501","city":"JBER","state":"AK","country":"USA"},"naics_codes":["238160"],"award":null,"attachments":[{"resource_id":"3c1c5ee4b3af412982569368e051cc3f","name":"Draft SOW - FXSB 26-6837 Repair Replace Roof B11525.pdf","kind":"file","mime_type":".pdf","size_bytes":708088,"posted_at":"2026-03-30T19:46:27.598Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3c1c5ee4b3af412982569368e051cc3f/download","mirrored":false},{"resource_id":"3117c7acdf6d476f80bba7339bfbd471","name":"Draft SOW - FXSB 26-6770 Repair Replace Roof B10571.pdf","kind":"file","mime_type":".pdf","size_bytes":268298,"posted_at":"2026-04-03T21:55:00.875Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3117c7acdf6d476f80bba7339bfbd471/download","mirrored":false}],"awards":[],"related":[{"key":"FA500027Q0003","latest_notice_id":"74cbaf3f9739463a836b2373a404e841","title":"Carpet Replacement Building 606","solicitation_number":"FA500027Q0003","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5000","office_name":"FA5000 673 CONS PKB","naics":"238330","psc":"7220","set_aside":"SBA","state":"AK","county":"02020","county_name":"Anchorage Municipality","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA500027Q0002","latest_notice_id":"4eb681d0737c4ecda22e7a3b3eec95a6","title":"Amendment 0001 - Local & Long-Distance Telecommunications Service-Joint Base Elmendorf-Richardson, Alaska","solicitation_number":"FA500027Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5000","office_name":"FA5000 673 CONS PKB","naics":"517111","psc":"DG11","set_aside":null,"state":"AK","county":"02020","county_name":"Anchorage Municipality","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Joint Base Elmendorf-Richardson","site_key":"joint-base-elmendorf-richardson-ak","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA500027RTCCC","latest_notice_id":"ac92070ab94b46e486565946a958b287","title":"JBER TCCC Training Services","solicitation_number":"FA5000-27-R-TCCC","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2027-01-01T01:00:00Z","due_date":"2026-12-31","closes_at":"2027-01-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5000","office_name":"FA5000 673 CONS PKB","naics":"611430","psc":"U008","set_aside":null,"state":"AK","county":"02020","county_name":"Anchorage Municipality","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open":[{"key":"SP470327Q0006","latest_notice_id":"cff3c7867386430c9e3932e1f5256e17","title":"DSCR Building 70 Roof Replacement","solicitation_number":"SP470327Q0006","notice_type":"p","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-23","notices":2,"due_at":"2026-11-26T04:59:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP4703","office_name":"DCSO RICHMOND DIVISION #1","naics":"238160","psc":"Z2AA","set_aside":"SBA","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"15B50127PR000024","latest_notice_id":"8d93258359d84f939b0db4192d6c7e53","title":"FCI Bastrop - Remove and Replace Housing Unit Roofs (10) 27Z5BB3","solicitation_number":"15B50127PR000024","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BFA0","office_name":"FAO","naics":"238160","psc":"Z2FF","set_aside":null,"state":"TX","county":"48021","county_name":"Bastrop County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"1240LT27Q0003","latest_notice_id":"af34b449094844d6a983249225d53185","title":"GAOA Mesa Falls VC Roof Repairs in Caribou-Targhee National Forest, Idaho","solicitation_number":"1240LT27Q0003","notice_type":"k","first_type":"k","first_posted":"2026-10-07","last_posted":"2026-10-07","notices":1,"due_at":"2026-12-01T22:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-123187","office_name":"USDA FOREST SERVICE","naics":"238160","psc":"Z2AZ","set_aside":"SBA","state":"ID","county":"16019","county_name":"Bonneville County","city":"1639700","city_name":"Idaho Falls","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Caribou-Targhee National Forest","site_key":"caribou-targhee-national-forest-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"}],"similar_open_total":10,"indexable":false}