{"canonical":"https://sealedbidder.com/opportunities/fmpnnl0047","key":"FMPNNL0047","url":"https://sealedbidder.com/opportunities/fmpnnl0047","title":"Water Valve Leak Mitigation","solicitation_number":"FMP-NNL-0047","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-03T21:00:00Z","first_posted":"2026-07-09","last_posted":"2026-07-09","department":"ENERGY, DEPARTMENT OF","subagency":"ENERGY, DEPARTMENT OF","office":"FLUOR MARINE PROPULSION - DOE CONTRACTOR","naics":"54171","psc":"AG12","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Research and development (PSC AG12)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"baf9100654e34e4cb0b32d40f583e542","title":"Water Valve Leak Mitigation","solicitation_number":"FMP-NNL-0047","notice_type":"r","base_type":"r","posted":"2026-07-09","posted_at":"2026-07-09T13:05:23.624Z","due_at":"2026-09-03T21:00:00Z","due_date":"2026-09-03","cancelled":false,"archived":true,"archive_date":"2026-09-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/baf9100654e34e4cb0b32d40f583e542/view","enriched":true,"history":[{"index":3,"title":"Water Valve Leak Mitigation","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T13:05:23.624Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"baf9100654e34e4cb0b32d40f583e542","solicitation_number":"FMP-NNL-0047"}]}],"latest_notice_id":"baf9100654e34e4cb0b32d40f583e542","first_type":"r","notices":[{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T13:05:23.624Z","created_at":"2026-07-09T13:02:01.007Z","modified_at":"2026-09-04T05:06:57.830Z","response_deadline":{"raw":"2026-09-03T17:00:00-04:00","utc":"2026-09-03T21:00:00Z","date":"2026-09-03","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/baf9100654e34e4cb0b32d40f583e542/view"},"naics":{"codes":["54171"],"primary":"54171"},"title":"Water Valve Leak Mitigation","agency":{"office":{"code":"899020","name":"FLUOR MARINE PROPULSION - DOE CONTRACTOR"},"subtier":{"code":"8900","name":"ENERGY, DEPARTMENT OF"},"department":{"code":"089","name":"ENERGY, DEPARTMENT OF"},"office_address":{"zip":"12301","city":"Schenectady","state":"NY","country":"USA"},"organization_id":"500171337","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-04","archive_type":"auto_custom"},"history":[{"index":3,"title":"Water Valve Leak Mitigation","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T13:05:23.624Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"baf9100654e34e4cb0b32d40f583e542","solicitation_number":"FMP-NNL-0047"}],"contacts":[{"name":"ATIP","role":"primary","email":"ATIP@unnpp.gov"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"baf9100654e34e4cb0b32d40f583e542","lineage_id":"baf9100654e34e4cb0b32d40f583e542","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T02:52:37.752526217Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"c8726bf991cffe97706d01f9a4fe1674196eacf1e6686041eab2896fe8d81f64","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T02:52:37.752526217Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>THIS IS A REQUEST FOR INFORMATION ONLY.&nbsp; THIS IS NOT A SOLICITATION.</p>\n\n<p>This notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement.&nbsp; NNL will not be responsible for any costs incurred by interested parties in responding to this request for information.</p>\n\n<p>Responses shall not exceed five (5) pages in length.</p>\n\n<p></p>\n\n<p>Scope:</p>\n\n<p>When performing maintenance on a pure water fluid system, valves are commonly used for work area isolation.&nbsp; Valves that have been in-service can leak past their seats.&nbsp; In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area.&nbsp; In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage.&nbsp; Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired.</p>\n\n<p>A method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance.&nbsp; The method must not introduce devices or materials that require removal from the system after repair is completed. &nbsp;Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive.</p>","text":"THIS IS A REQUEST FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION.\n\nThis notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement. NNL will not be responsible for any costs incurred by interested parties in responding to this request for information.\n\nResponses shall not exceed five (5) pages in length.\n\nScope:\n\nWhen performing maintenance on a pure water fluid system, valves are commonly used for work area isolation. Valves that have been in-service can leak past their seats. In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area. In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage. Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired.\n\nA method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance. The method must not introduce devices or materials that require removal from the system after repair is completed. Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"FMP-NNL-0047","place_of_performance":{"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"AG12"}],"due_at":"2026-09-03T21:00:00Z","due_date":"2026-09-03","closes_at":"2026-09-03T21:00:00Z","awardable":true,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899020","office_name":"FLUOR MARINE PROPULSION - DOE CONTRACTOR","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":"Research and development (PSC AG12)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T03:29:01.199186Z","principal_notice_id":"baf9100654e34e4cb0b32d40f583e542","description":{"text":"THIS IS A REQUEST FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION.\n\nThis notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement. NNL will not be responsible for any costs incurred by interested parties in responding to this request for information.\n\nResponses shall not exceed five (5) pages in length.\n\nScope:\n\nWhen performing maintenance on a pure water fluid system, valves are commonly used for work area isolation. Valves that have been in-service can leak past their seats. In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area. In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage. Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired.\n\nA method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance. The method must not introduce devices or materials that require removal from the system after repair is completed. Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive.","html":"<p>THIS IS A REQUEST FOR INFORMATION ONLY.&nbsp; THIS IS NOT A SOLICITATION.</p>\n\n<p>This notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement.&nbsp; NNL will not be responsible for any costs incurred by interested parties in responding to this request for information.</p>\n\n<p>Responses shall not exceed five (5) pages in length.</p>\n\n<p></p>\n\n<p>Scope:</p>\n\n<p>When performing maintenance on a pure water fluid system, valves are commonly used for work area isolation.&nbsp; Valves that have been in-service can leak past their seats.&nbsp; In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area.&nbsp; In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage.&nbsp; Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired.</p>\n\n<p>A method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance.&nbsp; The method must not introduce devices or materials that require removal from the system after repair is completed. &nbsp;Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive.</p>","origin":"detail"},"contacts":[{"name":"ATIP","role":"primary","email":"ATIP@unnpp.gov"}],"place_of_performance":{"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"12301","city":"Schenectady","state":"NY","country":"USA"},"naics_codes":["54171"],"award":null,"attachments":[],"awards":[],"related":[],"similar_open":[{"key":"FA865022S5002","latest_notice_id":"da352f9b611e4f0a90fa7fe438875fa1","title":"AFRL/RX Functional Materials Open BAA","solicitation_number":"FA8650-22-S-5002","notice_type":"o","first_type":"o","first_posted":"2025-04-11","last_posted":"2026-02-23","notices":3,"due_at":"2028-10-26T19:00:00Z","due_date":"2028-10-26","closes_at":"2028-10-26T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8650","office_name":"FA8650 USAF AFMC AFRL PZL AFRL/PZL","naics":"54171","psc":"AC12","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"AFRL/RX FUNCTIONAL MATERIALS OPEN BAA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"HHM40223S0001","latest_notice_id":"4180ee1405cc4aadbd14f5830c55e900","title":"NEEDIPEDIA BROAD AGENCY ANNOUNCEMENT - BAA","solicitation_number":"HHM402-23-S-0001","notice_type":"o","first_type":"o","first_posted":"2024-01-25","last_posted":"2025-12-22","notices":7,"due_at":"2028-12-26T17:59:00Z","due_date":"2028-12-26","closes_at":"2028-12-26T17:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DL","sub_name":"DEFENSE INTELLIGENCE AGENCY (DIA)","office_key":"o-HHM402","office_name":"VIRGINIA CONTRACTING ACTIVITY","naics":"54171","psc":"AC14","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"HDTRA124S0003","latest_notice_id":"9257d62bd63a4acab7f3852b78b81b52","title":"FY25-29 STRATEGIC TRENDS RESEARCH INITIATIVE BROAD AGENCY ANNOUNCEMENT","solicitation_number":"HDTRA124S0003","notice_type":"o","first_type":"o","first_posted":"2024-08-02","last_posted":"2025-04-30","notices":12,"due_at":"2029-08-01T06:30:00Z","due_date":"2029-08-01","closes_at":"2029-08-01T06:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-9761","sub_name":"DEFENSE THREAT REDUCTION AGENCY (DTRA)","office_key":"o-HDTRA1","office_name":"DEFENSE THREAT REDUCTION AGENCY","naics":"54171","psc":"AM12","set_aside":null,"state":"VA","county":"51059","county_name":"Fairfax County","city":"5129008","city_name":"Fort Belvoir","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-16T02:23:40.432617Z"}],"similar_open_total":4,"indexable":false}