{"canonical":"https://sealedbidder.com/opportunities/fdarfq25q1283892","key":"FDARFQ25Q1283892","url":"https://sealedbidder.com/opportunities/fdarfq25q1283892","title":"Retrofit Glatt GCG 70 Dry Mixer for signal exchange to third party equipment","solicitation_number":"FDA-RFQ-25Q1283892","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-01T14:00:00Z","first_posted":"2025-07-18","last_posted":"2025-07-18","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"FOOD AND DRUG ADMINISTRATION","office":"FDA OFFICE OF ACQ GRANT SVCS","naics":"334516","psc":"6640","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24033","place_county_name":"Prince George's County","place_city":"2406400","place_city_name":"Beltsville","winner":null,"award_amount":null,"publications":[{"notice_id":"bc6a14f8881c4354b9b0c669b67dd8f4","title":"Retrofit Glatt GCG 70 Dry Mixer for signal exchange to third party equipment","solicitation_number":"FDA-RFQ-25Q1283892","notice_type":"k","base_type":"k","posted":"2025-07-18","posted_at":"2025-07-18T12:23:11.115Z","due_at":"2025-08-01T14:00:00Z","due_date":"2025-08-01","cancelled":false,"archived":true,"archive_date":"2025-08-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/bc6a14f8881c4354b9b0c669b67dd8f4/view","enriched":true,"history":[{"index":3,"title":"Retrofit Glatt GCG 70 Dry Mixer for signal exchange to third party equipment","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-18T12:23:11.115Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"bc6a14f8881c4354b9b0c669b67dd8f4","solicitation_number":"FDA-RFQ-25Q1283892"}]}],"latest_notice_id":"bc6a14f8881c4354b9b0c669b67dd8f4","first_type":"k","notices":[{"dates":{"posted":"2025-07-18","posted_at":"2025-07-18T12:23:11.115Z","created_at":"2025-07-18T12:09:16.787Z","modified_at":"2025-08-16T04:04:28.366Z","response_deadline":{"raw":"2025-08-01T10:00:00-04:00","utc":"2025-08-01T14:00:00Z","date":"2025-08-01","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/bc6a14f8881c4354b9b0c669b67dd8f4/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Retrofit Glatt GCG 70 Dry Mixer for signal exchange to third party equipment","agency":{"office":{"code":"75F401","name":"FDA OFFICE OF ACQ GRANT SVCS"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"organization_id":"100188033","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-16","archive_type":"auto15"},"history":[{"index":3,"title":"Retrofit Glatt GCG 70 Dry Mixer for signal exchange to third party equipment","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-18T12:23:11.115Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"bc6a14f8881c4354b9b0c669b67dd8f4","solicitation_number":"FDA-RFQ-25Q1283892"}],"contacts":[{"name":"Warren Jackson","role":"primary","email":"warren.jackson@fda.hhs.gov","phone":"3018377147"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"bc6a14f8881c4354b9b0c669b67dd8f4","lineage_id":"bc6a14f8881c4354b9b0c669b67dd8f4","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-09T02:35:19.985716513Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"7399647732a58d6fe5fec3f9c26f5222d1619225b7ee2e59ddf33841205a9ec0","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-09T02:35:19.985716513Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Background</p>\n\n<p>The Office of Pharmaceutical Quality Research (OPQR) supports the modernization of pharmaceutical manufacturing by conducting regulatory science research on emerging technologies. Continuous manufacturing (CM) of oral solids has been recognized as an emerging technology by the FDA. Continuous process monitoring and manufacturing process control are critical for establishment of a robust CM process that can consistently produce product of desired quality, while identifying and mitigating manufacturing risks.</p>\n\n<p>Currently, OPQR possesses a Glatt GCG 70 continuous dry mixer. However, the GCG 70 lacks the capability to communicates with other equipment or systems. To integrate the GCG 70 into a CM line, a retrofit is required to enable it to interface with a supervisory control system. This upgrade will enhance the functionality of the GCG 70.</p>\n\n<p>This package includes both hardware and site services for retrofitting the GCG 70 dry mixer to facilitate signal exchange with other equipment. The retrofitted GCG 70 should be adaptable to CM operation which includes options for the seamless integration of upstream and downstream unit operations. It will also enable synchronized control of process parameters of other unit operations through automatic modulation.</p>\n\n<p>This retrofit is essential to support the New Drug Application (NDA) and Abbreviated New Drug Application (ANDA) review processes for CM applications.</p>\n\n<p><u>Scope</u></p>\n\n<p>To retrofit the GCG 70 Dry Mixer to communicate with the other equipment of systems.</p>\n\n<p><u>Requirements</u></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The GCG 70 retrofit shall meet the following salient characteristics:</p>\n\n<ul>\n\t<li>Shall enable electronic communication with SIMATIC PCS 7 distributed control system for integration with other equipment.</li>\n\t<li>Shall enable setting blender speed remotely, including start/stop, as well as feedback indicating that the blender is running and the actual speed.</li>\n\t<li>Shall not restrict or inhibit any existing operational capabilities of the GCG 70, including local control capability.</li>\n\t<li>Shall include one (1) year parts and labor with warranty from date of shipment.</li>\n</ul>\n\n<p><u>Delivery, Installation, and On-site Commissioning</u></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The vendor will cover all costs associated with the following:</p>\n\n<ul>\n\t<li>Hardware packaging, shipping, and delivery.</li>\n\t<li>On-site hardware installation, commissioning, and qualification.</li>\n\t<li>On-site assistance with supervisory control system commissioning.</li>\n\t<li>Updated qualification documents, instruction manuals, drawings/diagrams, and other related equipment documentation for the GCG 70</li>\n</ul>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li><u>INSPECTION/ACCEPTANCE CRITERIA</u></li>\n\t</ol>\n\t</li>\n</ol>\n\n<p>Inspection and acceptance shall be in accordance with the base clause 52.212-4(a). Contracting officer&rsquo;s representative (COR) is responsible for the inspection and acceptance of the deliverables for this requirement.</p>\n\n<p>&nbsp;<u>CONTRACT TYPE</u></p>\n\n<p>This is firm fixed price.</p>\n\n<p>&nbsp;<u>PERIOD OF PERFORMANCE</u></p>\n\n<p>&nbsp;The period of performance (POP) is for 180 days after award.</p>\n\n<p>&nbsp;<u>PLACE OF DELIVERY AND PERFORMANCE</u></p>\n\n<p>U.S. Food and Drug Administration</p>\n\n<p>5901 Ammendale Road</p>\n\n<p>Suite G</p>\n\n<p>Beltsville, MD 20705</p>\n\n<p>Attn: POC to be identified at time of the award.</p>","text":"Background\n\nThe Office of Pharmaceutical Quality Research (OPQR) supports the modernization of pharmaceutical manufacturing by conducting regulatory science research on emerging technologies. Continuous manufacturing (CM) of oral solids has been recognized as an emerging technology by the FDA. Continuous process monitoring and manufacturing process control are critical for establishment of a robust CM process that can consistently produce product of desired quality, while identifying and mitigating manufacturing risks.\n\nCurrently, OPQR possesses a Glatt GCG 70 continuous dry mixer. However, the GCG 70 lacks the capability to communicates with other equipment or systems. To integrate the GCG 70 into a CM line, a retrofit is required to enable it to interface with a supervisory control system. This upgrade will enhance the functionality of the GCG 70.\n\nThis package includes both hardware and site services for retrofitting the GCG 70 dry mixer to facilitate signal exchange with other equipment. The retrofitted GCG 70 should be adaptable to CM operation which includes options for the seamless integration of upstream and downstream unit operations. It will also enable synchronized control of process parameters of other unit operations through automatic modulation.\n\nThis retrofit is essential to support the New Drug Application (NDA) and Abbreviated New Drug Application (ANDA) review processes for CM applications.\n\nScope\n\nTo retrofit the GCG 70 Dry Mixer to communicate with the other equipment of systems.\n\nRequirements\n\nThe GCG 70 retrofit shall meet the following salient characteristics:\n\n• Shall enable electronic communication with SIMATIC PCS 7 distributed control system for integration with other equipment.\n\n• Shall enable setting blender speed remotely, including start/stop, as well as feedback indicating that the blender is running and the actual speed.\n\n• Shall not restrict or inhibit any existing operational capabilities of the GCG 70, including local control capability.\n\n• Shall include one (1) year parts and labor with warranty from date of shipment.\n\nDelivery, Installation, and On-site Commissioning\n\nThe vendor will cover all costs associated with the following:\n\n• Hardware packaging, shipping, and delivery.\n\n• On-site hardware installation, commissioning, and qualification.\n\n• On-site assistance with supervisory control system commissioning.\n\n• Updated qualification documents, instruction manuals, drawings/diagrams, and other related equipment documentation for the GCG 70\n\n•\n\n• INSPECTION/ACCEPTANCE CRITERIA\n\nInspection and acceptance shall be in accordance with the base clause 52.212-4(a). Contracting officer’s representative (COR) is responsible for the inspection and acceptance of the deliverables for this requirement.\n\nCONTRACT TYPE\n\nThis is firm fixed price.\n\nPERIOD OF PERFORMANCE\n\nThe period of performance (POP) is for 180 days after award.\n\nPLACE OF DELIVERY AND PERFORMANCE\n\nU.S. Food and Drug Administration\n\n5901 Ammendale Road\n\nSuite G\n\nBeltsville, MD 20705\n\nAttn: POC to be identified at time of the award.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FDA-RFQ-25Q1283892","place_of_performance":{"zip":"20705","city":{"code":"6400","name":"Beltsville"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2025-08-01T14:00:00Z","due_date":"2025-08-01","closes_at":"2025-08-01T14:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","state":"MD","county":"24033","county_name":"Prince George's County","city":"2406400","city_name":"Beltsville","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-09T03:24:22.313841Z","principal_notice_id":"bc6a14f8881c4354b9b0c669b67dd8f4","description":{"text":"Background\n\nThe Office of Pharmaceutical Quality Research (OPQR) supports the modernization of pharmaceutical manufacturing by conducting regulatory science research on emerging technologies. Continuous manufacturing (CM) of oral solids has been recognized as an emerging technology by the FDA. Continuous process monitoring and manufacturing process control are critical for establishment of a robust CM process that can consistently produce product of desired quality, while identifying and mitigating manufacturing risks.\n\nCurrently, OPQR possesses a Glatt GCG 70 continuous dry mixer. However, the GCG 70 lacks the capability to communicates with other equipment or systems. To integrate the GCG 70 into a CM line, a retrofit is required to enable it to interface with a supervisory control system. This upgrade will enhance the functionality of the GCG 70.\n\nThis package includes both hardware and site services for retrofitting the GCG 70 dry mixer to facilitate signal exchange with other equipment. The retrofitted GCG 70 should be adaptable to CM operation which includes options for the seamless integration of upstream and downstream unit operations. It will also enable synchronized control of process parameters of other unit operations through automatic modulation.\n\nThis retrofit is essential to support the New Drug Application (NDA) and Abbreviated New Drug Application (ANDA) review processes for CM applications.\n\nScope\n\nTo retrofit the GCG 70 Dry Mixer to communicate with the other equipment of systems.\n\nRequirements\n\nThe GCG 70 retrofit shall meet the following salient characteristics:\n\n• Shall enable electronic communication with SIMATIC PCS 7 distributed control system for integration with other equipment.\n\n• Shall enable setting blender speed remotely, including start/stop, as well as feedback indicating that the blender is running and the actual speed.\n\n• Shall not restrict or inhibit any existing operational capabilities of the GCG 70, including local control capability.\n\n• Shall include one (1) year parts and labor with warranty from date of shipment.\n\nDelivery, Installation, and On-site Commissioning\n\nThe vendor will cover all costs associated with the following:\n\n• Hardware packaging, shipping, and delivery.\n\n• On-site hardware installation, commissioning, and qualification.\n\n• On-site assistance with supervisory control system commissioning.\n\n• Updated qualification documents, instruction manuals, drawings/diagrams, and other related equipment documentation for the GCG 70\n\n•\n\n• INSPECTION/ACCEPTANCE CRITERIA\n\nInspection and acceptance shall be in accordance with the base clause 52.212-4(a). Contracting officer’s representative (COR) is responsible for the inspection and acceptance of the deliverables for this requirement.\n\nCONTRACT TYPE\n\nThis is firm fixed price.\n\nPERIOD OF PERFORMANCE\n\nThe period of performance (POP) is for 180 days after award.\n\nPLACE OF DELIVERY AND PERFORMANCE\n\nU.S. Food and Drug Administration\n\n5901 Ammendale Road\n\nSuite G\n\nBeltsville, MD 20705\n\nAttn: POC to be identified at time of the award.","html":"<p>Background</p>\n\n<p>The Office of Pharmaceutical Quality Research (OPQR) supports the modernization of pharmaceutical manufacturing by conducting regulatory science research on emerging technologies. Continuous manufacturing (CM) of oral solids has been recognized as an emerging technology by the FDA. Continuous process monitoring and manufacturing process control are critical for establishment of a robust CM process that can consistently produce product of desired quality, while identifying and mitigating manufacturing risks.</p>\n\n<p>Currently, OPQR possesses a Glatt GCG 70 continuous dry mixer. However, the GCG 70 lacks the capability to communicates with other equipment or systems. To integrate the GCG 70 into a CM line, a retrofit is required to enable it to interface with a supervisory control system. This upgrade will enhance the functionality of the GCG 70.</p>\n\n<p>This package includes both hardware and site services for retrofitting the GCG 70 dry mixer to facilitate signal exchange with other equipment. The retrofitted GCG 70 should be adaptable to CM operation which includes options for the seamless integration of upstream and downstream unit operations. It will also enable synchronized control of process parameters of other unit operations through automatic modulation.</p>\n\n<p>This retrofit is essential to support the New Drug Application (NDA) and Abbreviated New Drug Application (ANDA) review processes for CM applications.</p>\n\n<p><u>Scope</u></p>\n\n<p>To retrofit the GCG 70 Dry Mixer to communicate with the other equipment of systems.</p>\n\n<p><u>Requirements</u></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The GCG 70 retrofit shall meet the following salient characteristics:</p>\n\n<ul>\n\t<li>Shall enable electronic communication with SIMATIC PCS 7 distributed control system for integration with other equipment.</li>\n\t<li>Shall enable setting blender speed remotely, including start/stop, as well as feedback indicating that the blender is running and the actual speed.</li>\n\t<li>Shall not restrict or inhibit any existing operational capabilities of the GCG 70, including local control capability.</li>\n\t<li>Shall include one (1) year parts and labor with warranty from date of shipment.</li>\n</ul>\n\n<p><u>Delivery, Installation, and On-site Commissioning</u></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;The vendor will cover all costs associated with the following:</p>\n\n<ul>\n\t<li>Hardware packaging, shipping, and delivery.</li>\n\t<li>On-site hardware installation, commissioning, and qualification.</li>\n\t<li>On-site assistance with supervisory control system commissioning.</li>\n\t<li>Updated qualification documents, instruction manuals, drawings/diagrams, and other related equipment documentation for the GCG 70</li>\n</ul>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li><u>INSPECTION/ACCEPTANCE CRITERIA</u></li>\n\t</ol>\n\t</li>\n</ol>\n\n<p>Inspection and acceptance shall be in accordance with the base clause 52.212-4(a). Contracting officer&rsquo;s representative (COR) is responsible for the inspection and acceptance of the deliverables for this requirement.</p>\n\n<p>&nbsp;<u>CONTRACT TYPE</u></p>\n\n<p>This is firm fixed price.</p>\n\n<p>&nbsp;<u>PERIOD OF PERFORMANCE</u></p>\n\n<p>&nbsp;The period of performance (POP) is for 180 days after award.</p>\n\n<p>&nbsp;<u>PLACE OF DELIVERY AND PERFORMANCE</u></p>\n\n<p>U.S. Food and Drug Administration</p>\n\n<p>5901 Ammendale Road</p>\n\n<p>Suite G</p>\n\n<p>Beltsville, MD 20705</p>\n\n<p>Attn: POC to be identified at time of the award.</p>","origin":"detail"},"contacts":[{"name":"Warren Jackson","role":"primary","email":"warren.jackson@fda.hhs.gov","phone":"3018377147"}],"place_of_performance":{"zip":"20705","city":{"code":"6400","name":"Beltsville"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"0687fae05a774264bf03fa0bae279e49","name":"Combined Synopsis for GCG 70 Dry Mixer.pdf","kind":"file","mime_type":".pdf","size_bytes":570767,"posted_at":"2025-07-18T12:23:11.115Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0687fae05a774264bf03fa0bae279e49/download","mirrored":false}],"awards":[],"related":[{"key":"75F40126Q136817","latest_notice_id":"955053716c304fb9b9627b268abe4a42","title":"Service agreement on a Randox Daytona Plus Chemistry Analyzer Instrument","solicitation_number":"75F40126Q136817","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"811210","psc":"J066","set_aside":null,"state":"AR","county":"05069","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"FDA2026136896","latest_notice_id":"2e4e031f692445cab046a32280d4215a","title":"Adverse Events Monitoring Systems (AEMS)","solicitation_number":"FDA-2026-136896","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-03T17:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":null,"psc":null,"set_aside":null,"state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"75F40127R00002","latest_notice_id":"780583ad411042e2a84176f5a8d15163","title":"Preventative Maintenance of Above Standard Equipment (ASE) FDA National Capital Region","solicitation_number":"75F40127R00002","notice_type":"p","first_type":"p","first_posted":"2026-11-21","last_posted":"2026-11-21","notices":1,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"811210","psc":"J066","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-22T05:17:48.835238Z"},{"key":"FDARFQ136450","latest_notice_id":"323fe6cee8094b908c47a40c6203ded1","title":"JamF Software Licenses","solicitation_number":"FDA_RFQ_136450","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-25","notices":3,"due_at":"2026-12-07T18:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"513210","psc":"7A20","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2467675","city_name":"Rockville","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"FDA27137158","latest_notice_id":"b3625b61a12d41bc93867c0d5ee840db","title":"NOTICE OF INTENT TO AWARD SOLE SOURCE FOR POLICE ORDERS","solicitation_number":"FDA-27-137158","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-07T22:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"922120","psc":"R499","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2467675","city_name":"Rockville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":53,"indexable":false}