{"canonical":"https://sealedbidder.com/opportunities/fd20602700036","key":"FD20602700036","url":"https://sealedbidder.com/opportunities/fd20602700036","title":"C-5 Fire Suppression System Repair","solicitation_number":"FD206027-00036","notice_type":"p","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-11-27T10:00:00Z","first_posted":"2026-11-18","last_posted":"2026-11-18","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8538 AFSC PZAAB","naics":"336413","psc":"1680","set_aside":"SBA","place_state":"GA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"13167","place_county_name":"Johnson County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"b09df9734ec9405ba6b874b6f9468caf","title":"C-5 Fire Suppression System Repair","solicitation_number":"FD206027-00036","notice_type":"p","base_type":"p","posted":"2026-11-18","posted_at":"2026-11-18T13:47:22.590Z","due_at":"2026-11-27T10:00:00Z","due_date":"2026-11-27","cancelled":false,"archived":false,"archive_date":"2026-12-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b09df9734ec9405ba6b874b6f9468caf/view","enriched":true,"history":[{"index":1,"title":"C-5 Fire Suppression System Repair","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-18T13:47:22.590Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"b09df9734ec9405ba6b874b6f9468caf","solicitation_number":"FD206027-00036"}]}],"latest_notice_id":"b09df9734ec9405ba6b874b6f9468caf","first_type":"p","notices":[{"dates":{"posted":"2026-11-18","posted_at":"2026-11-18T13:47:22.590Z","created_at":"2026-11-12T14:45:48.223Z","modified_at":"2026-11-18T13:47:22.593Z","response_deadline":{"raw":"2026-11-27T05:00:00-05:00","utc":"2026-11-27T10:00:00Z","date":"2026-11-27","time":"05:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b09df9734ec9405ba6b874b6f9468caf/view"},"naics":{"codes":["336413"],"primary":"336413"},"title":"C-5 Fire Suppression System Repair","agency":{"office":{"code":"FA8538","name":"FA8538 AFSC PZAAB"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500042467","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-12","archive_type":"auto15"},"history":[{"index":1,"title":"C-5 Fire Suppression System Repair","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-18T13:47:22.590Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"b09df9734ec9405ba6b874b6f9468caf","solicitation_number":"FD206027-00036"}],"contacts":[{"name":"Jonathan Teece","role":"primary","email":"Jonathon.Teece@us.af.mil"},{"name":"Regina Daniely","role":"secondary","email":"regina.daniely@us.af.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"b09df9734ec9405ba6b874b6f9468caf","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"b09df9734ec9405ba6b874b6f9468caf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T06:56:52.499308809Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"6ef056520f5b764db7a4b6f45118f236-27\"","fetched_at":"2026-11-19T04:37:24.575886376Z","row_sha256":"3e3097de3b623664faff7cdef8768e656b329e026e21778462837adfb14c1f16","last_modified":"2026-11-19T04:30:19Z"},"updated_at":"2026-11-19T06:56:52.499308809Z","first_seen_at":"2026-11-19T04:37:24.575886376Z"},"description":{"html":"<p>C-5 Fire Suppression System</p>\n\n<p>This requirement is for depot-level repair for the nine competitive C-5 items listed below. The depot-level repair to be performed includes tear-down, evaluation, repair, testing, component procurement, packaging, handling, storage, transportation, as well as data collection. These services will provide assets to support all the C-5 aircraft until expected retirement of 2040. The assets provided by these services will be used to reduce current back orders and meet quarterly demand rates in support of Air Force sorties and aircraft Programmed Depot Maintenance (PDM).</p>\n\n<p></p>\n\n<p></p>\n\n<p>The best estimated quantities (BEQs) with estimated cost.</p>\n\n<p></p>\n\n<p class=\"sam-rich-text-editor-indent-a\">Noun National&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Stock Number (NSN)&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Part Number</p>\n\n<p>2 - Inch Zone Fire Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4810010033512&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720011-106</p>\n\n<p>Isolation Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4810010033513&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720012-105</p>\n\n<p>Shutoff Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4810010033514&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720013-107</p>\n\n<p>1 &frac14; - Inch Zone Fire Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4810010046559&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720015-107</p>\n\n<p>Primary Pressure Relief &amp; Overboard Relief Valve&nbsp; 4820001851031&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720125-101</p>\n\n<p>Pressure Limiter Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4820001851033&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720142-101</p>\n\n<p>Secondary Pressure Regulator&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4820001851037&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720224-101</p>\n\n<p>Fill Coupling Receptacle&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4820001867007&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720017-102</p>\n\n<p>Backpressure Relief Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4820002700682&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720119-102</p>\n\n<p>The projected period of contract performance for this requirement is five years. Period of performance is comprised of a basic year with 4 one-year ordering periods.</p>\n\n<p>Delivery of assets - Repaired assets shall be delivered in accordance with the schedule, as defined by the contract/order. Assets shall be delivered 95% of the time with the remaining 5% being delivered no more than seven (7) calendar days late. If delivery slips more than seven (7) calendar days from contract delivery schedule, the Contractor shall notify the contracting officer to negotiate a revised delivery date. Delivery of assets to fulfill a SURGE or MICAP requirement shall be thirty (30) calendar days after contractor receives notification of a SURGE or MICAP requirement if assets are already on hand at the contractor&#39;s facility. If no assets are on hand at the time of notification, delivery shall be thirty (30) calendar days after receipt of asset(s).</p>\n\n<p>Items included in this effort are military unique and the services do not meet the definitions of FAR Part 2 in terms of commercial items or non-developmental items which can be acquired in the commercial market sector using streamlined acquisition procedures under FAR Part 12.</p>\n\n<p>THIS IS NOT AN AWARD</p>\n\n<p>All replies are due by November 27,2026.</p>\n\n<p></p>\n\n<p></p>","text":"C-5 Fire Suppression System\n\nThis requirement is for depot-level repair for the nine competitive C-5 items listed below. The depot-level repair to be performed includes tear-down, evaluation, repair, testing, component procurement, packaging, handling, storage, transportation, as well as data collection. These services will provide assets to support all the C-5 aircraft until expected retirement of 2040. The assets provided by these services will be used to reduce current back orders and meet quarterly demand rates in support of Air Force sorties and aircraft Programmed Depot Maintenance (PDM).\n\nThe best estimated quantities (BEQs) with estimated cost.\n\nNoun National Stock Number (NSN) Part Number\n\n2 - Inch Zone Fire Valve 4810010033512 7720011-106\n\nIsolation Valve 4810010033513 7720012-105\n\nShutoff Valve 4810010033514 7720013-107\n\n1 ¼ - Inch Zone Fire Valve 4810010046559 7720015-107\n\nPrimary Pressure Relief & Overboard Relief Valve 4820001851031 7720125-101\n\nPressure Limiter Valve 4820001851033 7720142-101\n\nSecondary Pressure Regulator 4820001851037 7720224-101\n\nFill Coupling Receptacle 4820001867007 7720017-102\n\nBackpressure Relief Valve 4820002700682 7720119-102\n\nThe projected period of contract performance for this requirement is five years. Period of performance is comprised of a basic year with 4 one-year ordering periods.\n\nDelivery of assets - Repaired assets shall be delivered in accordance with the schedule, as defined by the contract/order. Assets shall be delivered 95% of the time with the remaining 5% being delivered no more than seven (7) calendar days late. If delivery slips more than seven (7) calendar days from contract delivery schedule, the Contractor shall notify the contracting officer to negotiate a revised delivery date. Delivery of assets to fulfill a SURGE or MICAP requirement shall be thirty (30) calendar days after contractor receives notification of a SURGE or MICAP requirement if assets are already on hand at the contractor's facility. If no assets are on hand at the time of notification, delivery shall be thirty (30) calendar days after receipt of asset(s).\n\nItems included in this effort are military unique and the services do not meet the definitions of FAR Part 2 in terms of commercial items or non-developmental items which can be acquired in the commercial market sector using streamlined acquisition procedures under FAR Part 12.\n\nTHIS IS NOT AN AWARD\n\nAll replies are due by November 27,2026.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"FD206027-00036","place_of_performance":{"zip":"31096","state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"1680"}],"due_at":"2026-11-27T10:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T10:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","state":"GA","county":"13167","county_name":"Johnson County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-19T04:41:36.780616Z","principal_notice_id":"b09df9734ec9405ba6b874b6f9468caf","description":{"text":"C-5 Fire Suppression System\n\nThis requirement is for depot-level repair for the nine competitive C-5 items listed below. The depot-level repair to be performed includes tear-down, evaluation, repair, testing, component procurement, packaging, handling, storage, transportation, as well as data collection. These services will provide assets to support all the C-5 aircraft until expected retirement of 2040. The assets provided by these services will be used to reduce current back orders and meet quarterly demand rates in support of Air Force sorties and aircraft Programmed Depot Maintenance (PDM).\n\nThe best estimated quantities (BEQs) with estimated cost.\n\nNoun National Stock Number (NSN) Part Number\n\n2 - Inch Zone Fire Valve 4810010033512 7720011-106\n\nIsolation Valve 4810010033513 7720012-105\n\nShutoff Valve 4810010033514 7720013-107\n\n1 ¼ - Inch Zone Fire Valve 4810010046559 7720015-107\n\nPrimary Pressure Relief & Overboard Relief Valve 4820001851031 7720125-101\n\nPressure Limiter Valve 4820001851033 7720142-101\n\nSecondary Pressure Regulator 4820001851037 7720224-101\n\nFill Coupling Receptacle 4820001867007 7720017-102\n\nBackpressure Relief Valve 4820002700682 7720119-102\n\nThe projected period of contract performance for this requirement is five years. Period of performance is comprised of a basic year with 4 one-year ordering periods.\n\nDelivery of assets - Repaired assets shall be delivered in accordance with the schedule, as defined by the contract/order. Assets shall be delivered 95% of the time with the remaining 5% being delivered no more than seven (7) calendar days late. If delivery slips more than seven (7) calendar days from contract delivery schedule, the Contractor shall notify the contracting officer to negotiate a revised delivery date. Delivery of assets to fulfill a SURGE or MICAP requirement shall be thirty (30) calendar days after contractor receives notification of a SURGE or MICAP requirement if assets are already on hand at the contractor's facility. If no assets are on hand at the time of notification, delivery shall be thirty (30) calendar days after receipt of asset(s).\n\nItems included in this effort are military unique and the services do not meet the definitions of FAR Part 2 in terms of commercial items or non-developmental items which can be acquired in the commercial market sector using streamlined acquisition procedures under FAR Part 12.\n\nTHIS IS NOT AN AWARD\n\nAll replies are due by November 27,2026.","html":"<p>C-5 Fire Suppression System</p>\n\n<p>This requirement is for depot-level repair for the nine competitive C-5 items listed below. The depot-level repair to be performed includes tear-down, evaluation, repair, testing, component procurement, packaging, handling, storage, transportation, as well as data collection. These services will provide assets to support all the C-5 aircraft until expected retirement of 2040. The assets provided by these services will be used to reduce current back orders and meet quarterly demand rates in support of Air Force sorties and aircraft Programmed Depot Maintenance (PDM).</p>\n\n<p></p>\n\n<p></p>\n\n<p>The best estimated quantities (BEQs) with estimated cost.</p>\n\n<p></p>\n\n<p class=\"sam-rich-text-editor-indent-a\">Noun National&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Stock Number (NSN)&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Part Number</p>\n\n<p>2 - Inch Zone Fire Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4810010033512&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720011-106</p>\n\n<p>Isolation Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4810010033513&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720012-105</p>\n\n<p>Shutoff Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4810010033514&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720013-107</p>\n\n<p>1 &frac14; - Inch Zone Fire Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4810010046559&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720015-107</p>\n\n<p>Primary Pressure Relief &amp; Overboard Relief Valve&nbsp; 4820001851031&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720125-101</p>\n\n<p>Pressure Limiter Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4820001851033&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720142-101</p>\n\n<p>Secondary Pressure Regulator&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4820001851037&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720224-101</p>\n\n<p>Fill Coupling Receptacle&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4820001867007&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 7720017-102</p>\n\n<p>Backpressure Relief Valve&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 4820002700682&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7720119-102</p>\n\n<p>The projected period of contract performance for this requirement is five years. Period of performance is comprised of a basic year with 4 one-year ordering periods.</p>\n\n<p>Delivery of assets - Repaired assets shall be delivered in accordance with the schedule, as defined by the contract/order. Assets shall be delivered 95% of the time with the remaining 5% being delivered no more than seven (7) calendar days late. If delivery slips more than seven (7) calendar days from contract delivery schedule, the Contractor shall notify the contracting officer to negotiate a revised delivery date. Delivery of assets to fulfill a SURGE or MICAP requirement shall be thirty (30) calendar days after contractor receives notification of a SURGE or MICAP requirement if assets are already on hand at the contractor&#39;s facility. If no assets are on hand at the time of notification, delivery shall be thirty (30) calendar days after receipt of asset(s).</p>\n\n<p>Items included in this effort are military unique and the services do not meet the definitions of FAR Part 2 in terms of commercial items or non-developmental items which can be acquired in the commercial market sector using streamlined acquisition procedures under FAR Part 12.</p>\n\n<p>THIS IS NOT AN AWARD</p>\n\n<p>All replies are due by November 27,2026.</p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Jonathan Teece","role":"primary","email":"Jonathon.Teece@us.af.mil"},{"name":"Regina Daniely","role":"secondary","email":"regina.daniely@us.af.mil"}],"place_of_performance":{"zip":"31096","state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"naics_codes":["336413"],"award":null,"attachments":[{"resource_id":"90d8bcacd73b42649d3160dcf2318864","name":"C-5_FSS_PWS.pdf","kind":"file","mime_type":".pdf","size_bytes":221167,"posted_at":"2026-11-18T13:47:22.590Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/90d8bcacd73b42649d3160dcf2318864/download","mirrored":false}],"awards":[],"related":[{"key":"FA853826R0017","latest_notice_id":"3b037426d9cb41b9a93923a626fc3565","title":"Repair/Overhaul of Flat Panel Up Front Controller (FPUFC)","solicitation_number":"FA853826R0017","notice_type":"o","first_type":"p","first_posted":"2026-04-29","last_posted":"2026-09-29","notices":3,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"811210","psc":"J059","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-30T04:14:25.251125Z"},{"key":"2710272026","latest_notice_id":"5434e63ca77e4c21b45ab835c40a1082","title":"C-130 NP2000 PROPELLER DEPOT LEVEL REPAIRABLE ITEMS","solicitation_number":"27-10272026","notice_type":"r","first_type":"r","first_posted":"2026-10-27","last_posted":"2026-10-27","notices":2,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"488190","psc":"J016","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-28T04:01:09.175983Z"},{"key":"MOVINGISLANDACTUATORS","latest_notice_id":"30cc7f9970ac4c1988faafd47c9d94cd","title":"Sources Sought Synopsis (SSS) for Repair of C-5 Moving Island Actuators","solicitation_number":"MOVING_ISLAND_ACTUATORS","notice_type":"r","first_type":"r","first_posted":"2026-10-29","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-28T22:30:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"336413","psc":"1680","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 1680)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"FA8538PRESSUREIND","latest_notice_id":"22b4d04dd69441188d70e20b8041fe2f","title":"C-130 Pressure Indicator NSN: 6620-01-394-4019 LG","solicitation_number":"FA8538PRESSUREIND","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"336413","psc":"6620","set_aside":"SBA","state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"FA8538260019","latest_notice_id":"841e784e6b954937a13971d839798ec3","title":"C-5 MLG Trunnion Bearing","solicitation_number":"FA8538260019","notice_type":"o","first_type":"o","first_posted":"2026-07-29","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"336413","psc":"J031","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"SPE4A727R0126","latest_notice_id":"6fa2f21e25864db0ab0a3cead0867186","title":"NSN: 1650-012047657,PART NO: 07111354-001, WSDC: 115/AIRCRAFT, GALAXY C5","solicitation_number":"SPE4A727R0126","notice_type":"p","first_type":"r","first_posted":"2026-11-03","last_posted":"2026-11-10","notices":2,"due_at":"2026-11-25T20:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A7","office_name":"DLA AVIATION","naics":"336413","psc":"1650","set_aside":null,"state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"FA8538PRESSUREIND","latest_notice_id":"22b4d04dd69441188d70e20b8041fe2f","title":"C-130 Pressure Indicator NSN: 6620-01-394-4019 LG","solicitation_number":"FA8538PRESSUREIND","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"336413","psc":"6620","set_aside":"SBA","state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"FA8538260019","latest_notice_id":"841e784e6b954937a13971d839798ec3","title":"C-5 MLG Trunnion Bearing","solicitation_number":"FA8538260019","notice_type":"o","first_type":"o","first_posted":"2026-07-29","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"336413","psc":"J031","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":567,"indexable":true}