{"canonical":"https://sealedbidder.com/opportunities/fd20602700008","key":"FD20602700008","url":"https://sealedbidder.com/opportunities/fd20602700008","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FD20602700008","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-02T20:00:00Z","first_posted":"2026-03-18","last_posted":"2026-03-18","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8517 AFSC PZAAC","naics":"811210","psc":"4920","set_aside":null,"place_state":"GA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":"1380508","place_city_name":"Warner Robins","winner":null,"award_amount":null,"publications":[{"notice_id":"20e09e9956d94900b16cfa2bfc0dca92","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FD20602700008","notice_type":"p","base_type":"p","posted":"2026-03-18","posted_at":"2026-03-18T13:07:59.034Z","due_at":"2026-04-02T20:00:00Z","due_date":"2026-04-02","cancelled":false,"archived":true,"archive_date":"2026-04-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/20e09e9956d94900b16cfa2bfc0dca92/view","enriched":true,"history":[{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}]}],"latest_notice_id":"20e09e9956d94900b16cfa2bfc0dca92","first_type":"p","notices":[{"dates":{"posted":"2026-03-18","posted_at":"2026-03-18T13:07:59.034Z","created_at":"2026-03-18T12:54:46.183Z","modified_at":"2026-04-18T03:55:46.116Z","response_deadline":{"raw":"2026-04-02T16:00:00-04:00","utc":"2026-04-02T20:00:00Z","date":"2026-04-02","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/20e09e9956d94900b16cfa2bfc0dca92/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","agency":{"office":{"code":"FA8517","name":"FA8517 AFSC PZAAC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500039862","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-17","archive_type":"auto15"},"history":[{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}],"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"20e09e9956d94900b16cfa2bfc0dca92","lineage_id":"96850d0299f546de9d2edbbf98bf1efc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T01:10:08.314960350Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"cf27f84d4fb3b1ac3a9f6305e75ebeff7456afc85379d910f93901cb8546e874","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T01:10:08.314960350Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN,</p>\n\n<p>P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage. The following table reflects the Best Estimated Quantity (BEQ).&nbsp;&nbsp;</p>\n\n<p>Basic&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<br />\nOrdering Period 1 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<br />\nOrdering Period 2 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<br />\nOrdering Period 3 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<br />\nOrdering Period 4 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><br />\n&nbsp; &nbsp;&nbsp;</p>","text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN,\n\nP/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage. The following table reflects the Best Estimated Quantity (BEQ).\n\nBasic 10\n\nOrdering Period 1 10\n\nOrdering Period 2 10\n\nOrdering Period 3 10\n\nOrdering Period 4 10","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"FD20602700008","place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4920"}],"due_at":"2026-04-02T20:00:00Z","due_date":"2026-04-02","closes_at":"2026-04-02T20:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8517","office_name":"FA8517 AFSC PZAAC","state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-11T01:44:22.489590Z","principal_notice_id":"20e09e9956d94900b16cfa2bfc0dca92","description":{"text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN,\n\nP/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage. The following table reflects the Best Estimated Quantity (BEQ).\n\nBasic 10\n\nOrdering Period 1 10\n\nOrdering Period 2 10\n\nOrdering Period 3 10\n\nOrdering Period 4 10","html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN,</p>\n\n<p>P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage. The following table reflects the Best Estimated Quantity (BEQ).&nbsp;&nbsp;</p>\n\n<p>Basic&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<br />\nOrdering Period 1 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<br />\nOrdering Period 2 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<br />\nOrdering Period 3 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<br />\nOrdering Period 4 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 10&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><br />\n&nbsp; &nbsp;&nbsp;</p>","origin":"detail"},"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"naics_codes":["811210"],"award":null,"attachments":[],"awards":[],"related":[],"similar_open":[{"key":"FA857127Q0012","latest_notice_id":"7e9eedb22d6841709dc019ba3f04e0aa","title":"PCDMIS CAD++ Software Renewal and CMM Calibration","solicitation_number":"FA857127Q0012","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"811210","psc":"J066","set_aside":null,"state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"FA853826R0017","latest_notice_id":"3b037426d9cb41b9a93923a626fc3565","title":"Repair/Overhaul of Flat Panel Up Front Controller (FPUFC)","solicitation_number":"FA853826R0017","notice_type":"o","first_type":"p","first_posted":"2026-04-29","last_posted":"2026-09-29","notices":3,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"811210","psc":"J059","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-30T04:14:25.251125Z"},{"key":"36C24727Q0067","latest_notice_id":"f75d8541b0604a57a55c64094b365d82","title":"J065--Building 3 Dental Vacuum Pump Replacement","solicitation_number":"36C24727Q0067","notice_type":"k","first_type":"r","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":6,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"GA","county":"13175","county_name":"Laurens County","city":"1324376","city_name":"Dublin","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":65,"indexable":false}