{"canonical":"https://sealedbidder.com/opportunities/fa857126q0087","key":"FA857126Q0087","url":"https://sealedbidder.com/opportunities/fa857126q0087","title":"L7-090 Repair and Liner - Chemical Storage Tanks","solicitation_number":"FA857126Q0087","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-01T18:00:00Z","first_posted":"2026-07-01","last_posted":"2026-07-01","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"238990","psc":"J049","set_aside":null,"place_state":"GA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"13153","place_county_name":"Houston County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"1136724f8b7547b0b34908c3d3a36b15","title":"L7-090 Repair and Liner - Chemical Storage Tanks","solicitation_number":"FA857126Q0087","notice_type":"k","base_type":"k","posted":"2026-07-01","posted_at":"2026-07-01T19:44:03.250Z","due_at":"2026-07-02T18:00:00Z","due_date":"2026-07-02","cancelled":false,"archived":true,"archive_date":"2026-07-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1136724f8b7547b0b34908c3d3a36b15/view","enriched":true,"history":[{"index":4,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T19:44:03.250Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"1136724f8b7547b0b34908c3d3a36b15","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":2,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T17:15:38.740Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9ccb25f96127440fbdca899e63feb212","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":1,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T16:41:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ab59222407c14f72933ae2eef50345b3","solicitation_number":"FA857126Q0087"}]},{"notice_id":"9ccb25f96127440fbdca899e63feb212","title":"L7-090 Repair and Liner - Chemical Storage Tanks","solicitation_number":"FA857126Q0087","notice_type":"k","base_type":"k","posted":"2026-07-01","posted_at":"2026-07-01T17:15:38.740Z","due_at":"2026-07-01T18:00:00Z","due_date":"2026-07-01","cancelled":false,"archived":true,"archive_date":"2026-07-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9ccb25f96127440fbdca899e63feb212/view","enriched":true,"history":[{"index":4,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T19:44:03.250Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"1136724f8b7547b0b34908c3d3a36b15","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":2,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T17:15:38.740Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9ccb25f96127440fbdca899e63feb212","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":1,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T16:41:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ab59222407c14f72933ae2eef50345b3","solicitation_number":"FA857126Q0087"}]},{"notice_id":"ab59222407c14f72933ae2eef50345b3","title":"L7-090 Repair and Liner - Chemical Storage Tanks","solicitation_number":"FA857126Q0087","notice_type":"k","base_type":"k","posted":"2026-07-01","posted_at":"2026-07-01T16:41:27.915Z","due_at":"2026-07-01T18:00:00Z","due_date":"2026-07-01","cancelled":false,"archived":true,"archive_date":"2026-07-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ab59222407c14f72933ae2eef50345b3/view","enriched":true,"history":[{"index":4,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T19:44:03.250Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"1136724f8b7547b0b34908c3d3a36b15","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":2,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T17:15:38.740Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9ccb25f96127440fbdca899e63feb212","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":1,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T16:41:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ab59222407c14f72933ae2eef50345b3","solicitation_number":"FA857126Q0087"}]}],"latest_notice_id":"ab59222407c14f72933ae2eef50345b3","first_type":"k","notices":[{"dates":{"posted":"2026-07-01","posted_at":"2026-07-01T19:44:03.250Z","created_at":"2026-07-01T17:16:00.569Z","modified_at":"2026-07-18T04:04:29.336Z","response_deadline":{"raw":"2026-07-02T14:00:00-04:00","utc":"2026-07-02T18:00:00Z","date":"2026-07-02","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1136724f8b7547b0b34908c3d3a36b15/view"},"naics":{"codes":["238990"],"primary":"238990"},"title":"L7-090 Repair and Liner - Chemical Storage Tanks","agency":{"office":{"code":"FA8571","name":"FA8571 MAINT CONTRACTING AFSC PZIM"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500022528","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-17","archive_type":"auto15"},"history":[{"index":4,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T19:44:03.250Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"1136724f8b7547b0b34908c3d3a36b15","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":2,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T17:15:38.740Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9ccb25f96127440fbdca899e63feb212","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":1,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T16:41:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ab59222407c14f72933ae2eef50345b3","solicitation_number":"FA857126Q0087"}],"contacts":[{"name":"Nikia Streeter","role":"primary","email":"nikia.streeter@us.af.mil"},{"name":"Taylor Walker","role":"secondary","email":"taylor.walker.10@us.af.mil","phone":"7303278055"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"1136724f8b7547b0b34908c3d3a36b15","lineage_id":"ab59222407c14f72933ae2eef50345b3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T12:45:33.063711529Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"7a7d67142d83362f35d6a82834b93dca65b71c7f87d90173459e49b83a5bccaa","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T12:45:33.063711529Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.<br />\n<br />\nThe Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.</p>\n\n<p>The Contractor shall provide the following:<br />\n&bull; Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.<br />\n&bull; 1 each (PVDF) Kynar&reg; Rigid Box Liner to fit CMXG&rsquo;s existing tank<br />\n&bull; Approximately 48&rdquo; x 48&rdquo; x 72&rdquo; deep, fabricated from &frac14;&rdquo; thick Kynar 2850 Flex sidewalls and rim and 3/8&rdquo; thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System</p>\n\n<p></p>\n\n<p><strong>Amendment 0001 corrects Period of Performance for CLIN 0002 and adjust responses due date to account for the High Priority need of this effort.</strong></p>","text":"This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.\n\nThe Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.\n\nThe Contractor shall provide the following:\n\n• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.\n\n• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank\n\n• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System\n\nAmendment 0001 corrects Period of Performance for CLIN 0002 and adjust responses due date to account for the High Priority need of this effort.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA857126Q0087","place_of_performance":{"zip":"31098","state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J049"},{"dates":{"posted":"2026-07-01","posted_at":"2026-07-01T17:15:38.740Z","created_at":"2026-07-01T17:04:10.928Z","modified_at":"2026-07-18T04:04:29.336Z","response_deadline":{"raw":"2026-07-01T14:00:00-04:00","utc":"2026-07-01T18:00:00Z","date":"2026-07-01","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9ccb25f96127440fbdca899e63feb212/view"},"naics":{"codes":["238990"],"primary":"238990"},"title":"L7-090 Repair and Liner - Chemical Storage Tanks","agency":{"office":{"code":"FA8571","name":"FA8571 MAINT CONTRACTING AFSC PZIM"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500022528","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-10","archive_type":"auto_custom"},"history":[{"index":4,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T19:44:03.250Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"1136724f8b7547b0b34908c3d3a36b15","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":2,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T17:15:38.740Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9ccb25f96127440fbdca899e63feb212","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":1,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T16:41:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ab59222407c14f72933ae2eef50345b3","solicitation_number":"FA857126Q0087"}],"contacts":[{"name":"Nikia Streeter","role":"primary","email":"nikia.streeter@us.af.mil"},{"name":"Taylor Walker","role":"secondary","email":"taylor.walker.10@us.af.mil","phone":"7303278055"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"9ccb25f96127440fbdca899e63feb212","lineage_id":"ab59222407c14f72933ae2eef50345b3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T13:21:48.922535407Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"d4aa343ad25c06d818122ae6c5e9cbbb0b133c8bc93a21a7b5feb087ff03f0c0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T13:21:48.922535407Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.<br />\n<br />\nThe Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.</p>\n\n<p>The Contractor shall provide the following:<br />\n&bull; Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.<br />\n&bull; 1 each (PVDF) Kynar&reg; Rigid Box Liner to fit CMXG&rsquo;s existing tank<br />\n&bull; Approximately 48&rdquo; x 48&rdquo; x 72&rdquo; deep, fabricated from &frac14;&rdquo; thick Kynar 2850 Flex sidewalls and rim and 3/8&rdquo; thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System</p>","text":"This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.\n\nThe Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.\n\nThe Contractor shall provide the following:\n\n• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.\n\n• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank\n\n• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA857126Q0087","place_of_performance":{"zip":"31098","state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J049"},{"dates":{"posted":"2026-07-01","posted_at":"2026-07-01T16:41:27.915Z","created_at":"2026-07-01T16:28:27.800Z","modified_at":"2026-07-18T04:04:29.336Z","response_deadline":{"raw":"2026-07-01T14:00:00-04:00","utc":"2026-07-01T18:00:00Z","date":"2026-07-01","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ab59222407c14f72933ae2eef50345b3/view"},"naics":{"codes":["238990"],"primary":"238990"},"title":"L7-090 Repair and Liner - Chemical Storage Tanks","agency":{"office":{"code":"FA8571","name":"FA8571 MAINT CONTRACTING AFSC PZIM"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500022528","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-10","archive_type":"auto_custom"},"history":[{"index":4,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T19:44:03.250Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"1136724f8b7547b0b34908c3d3a36b15","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":2,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T17:15:38.740Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9ccb25f96127440fbdca899e63feb212","solicitation_number":"FA857126Q0087","parent_opportunity_id":"ab59222407c14f72933ae2eef50345b3"},{"index":1,"title":"L7-090 Repair and Liner - Chemical Storage Tanks","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T16:41:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ab59222407c14f72933ae2eef50345b3","solicitation_number":"FA857126Q0087"}],"contacts":[{"name":"Nikia Streeter","role":"primary","email":"nikia.streeter@us.af.mil"},{"name":"Taylor Walker","role":"secondary","email":"taylor.walker.10@us.af.mil","phone":"7303278055"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"ab59222407c14f72933ae2eef50345b3","lineage_id":"ab59222407c14f72933ae2eef50345b3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T13:28:57.965611252Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"6821d54f0247fb841870bc4a95bd82b73a37ea2369707fef4dd701db2f2aeb58","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T13:28:57.965611252Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.</p>\n\n<p>The Contractor shall provide the following:<br />\n&bull; Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.<br />\n&bull; 1 each (PVDF) Kynar&reg; Rigid Box Liner to fit CMXG&rsquo;s existing tank<br />\n&bull; Approximately 48&rdquo; x 48&rdquo; x 72&rdquo; deep, fabricated from &frac14;&rdquo; thick Kynar 2850 Flex sidewalls and rim and 3/8&rdquo; thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System</p>","text":"The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.\n\nThe Contractor shall provide the following:\n\n• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.\n\n• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank\n\n• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA857126Q0087","place_of_performance":{"zip":"31098","state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J049"}],"due_at":"2026-07-01T18:00:00Z","due_date":"2026-07-01","closes_at":"2026-07-01T18:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","state":"GA","county":"13153","county_name":"Houston County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T13:43:22.134420Z","principal_notice_id":"ab59222407c14f72933ae2eef50345b3","description":{"text":"The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.\n\nThe Contractor shall provide the following:\n\n• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.\n\n• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank\n\n• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System","html":"<p>The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.</p>\n\n<p>The Contractor shall provide the following:<br />\n&bull; Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.<br />\n&bull; 1 each (PVDF) Kynar&reg; Rigid Box Liner to fit CMXG&rsquo;s existing tank<br />\n&bull; Approximately 48&rdquo; x 48&rdquo; x 72&rdquo; deep, fabricated from &frac14;&rdquo; thick Kynar 2850 Flex sidewalls and rim and 3/8&rdquo; thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System</p>","origin":"detail"},"contacts":[{"name":"Nikia Streeter","role":"primary","email":"nikia.streeter@us.af.mil"},{"name":"Taylor Walker","role":"secondary","email":"taylor.walker.10@us.af.mil","phone":"7303278055"}],"place_of_performance":{"zip":"31098","state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"naics_codes":["238990"],"award":null,"attachments":[{"resource_id":"edb1b0786d154631b0dadb199cdaf406","name":"82035 - CDRL A005 - Accident Incident Report.pdf","kind":"file","mime_type":".pdf","size_bytes":257883,"posted_at":"2026-07-01T16:41:27.915Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/edb1b0786d154631b0dadb199cdaf406/download","mirrored":false}],"awards":[],"related":[{"key":"FA857127Q0012","latest_notice_id":"7e9eedb22d6841709dc019ba3f04e0aa","title":"PCDMIS CAD++ Software Renewal and CMM Calibration","solicitation_number":"FA857127Q0012","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"811210","psc":"J066","set_aside":null,"state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"FA857127Q0026","latest_notice_id":"335166eb8e0f48b093fb03b970aafa40","title":"RANGER Crew XP 1000 NorthStar Edition Premium Blue Labyrinth Robins AFB","solicitation_number":"FA857127Q0026","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"336999","psc":"2340","set_aside":"SBA","state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Robins Air Force Base","site_key":"robins-air-force-base-ga","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"FA857127Q0028","latest_notice_id":"99163a0141a34ed7b91d2cff42ca9c75","title":"2027 POLARIS RANGER CREW XP 1000 NORTHSTAR EDITION WITH TURN SIGNALS/HORN - Stealth Gray Robins AFB GA","solicitation_number":"FA857127Q0028","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"336999","psc":"2340","set_aside":"SBA","state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Robins Air Force Base","site_key":"robins-air-force-base-ga","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"FA857127Q0025HYBRIDLASERTRIMMER","latest_notice_id":"f0f2017e83964ac3aca1682816c6d339","title":"L7WE01 Hybrid Laser Trimmer","solicitation_number":"FA857127Q0025_Hybrid_Laser_Trimmer","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"333517","psc":"6625","set_aside":"SBA","state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"BAB347FE72D145ECA283C108307E56FF","latest_notice_id":"ef93cb126800433a84a35bbe03fdb0b0","title":"AMFF LINE1 CRANE 2 REPLACEMENT","solicitation_number":"82115","notice_type":"o","first_type":"o","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"333923","psc":"3950","set_aside":null,"state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-22T05:17:48.835238Z"}],"similar_open":[{"key":"89503511102026","latest_notice_id":"0ce0ea259f874fdb9f21111ffe17cd5e","title":"SEPA PARKING LOT REPAVING AND REPAIRS","solicitation_number":"89503511102026","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-23","notices":7,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-895035","office_name":"SOUTHEASTERN POWER ADMINISTRATION","naics":"238990","psc":"Z2LZ","set_aside":null,"state":"GA","county":"13105","county_name":"Elbert County","city":"1326616","city_name":"Elberton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0089","latest_notice_id":"b09541b11a924f7f9b36cdc248c8ec4a","title":"Replace Condensate Pressure Pump","solicitation_number":"36C26227Q0089","notice_type":"k","first_type":"k","first_posted":"2026-11-10","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238990","psc":"J043","set_aside":"SDVOSBC","state":"CA","county":"06037","county_name":"Los Angeles County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"HAFBOMRFI01","latest_notice_id":"3e29465810a54cf980e7f342377edc60","title":"Opacity Meter Quarterly Inspections","solicitation_number":"HAFBOM_RFI01","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA2835","office_name":"FA2835 AFLCMC HANSCOM PZI","naics":"238990","psc":"Z1NB","set_aside":"SBA","state":"MA","county":"25017","county_name":"Middlesex County","city":"2528425","city_name":"Hanscom AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":21,"indexable":false}