{"canonical":"https://sealedbidder.com/opportunities/fa851726q0002","key":"FA851726Q0002","url":"https://sealedbidder.com/opportunities/fa851726q0002","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FA851726Q0002","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-22T04:00:00Z","first_posted":"2026-04-03","last_posted":"2026-05-19","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8517 AFSC PZAAC","naics":"811210","psc":"4920","set_aside":null,"place_state":"GA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":"1380508","place_city_name":"Warner Robins","winner":null,"award_amount":null,"publications":[{"notice_id":"72f716b768cd4382ada9623a243b5814","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FA851726Q0002","notice_type":"o","base_type":"o","posted":"2026-04-03","posted_at":"2026-04-03T12:23:21.522Z","due_at":"2026-05-03T16:00:00Z","due_date":"2026-05-03","cancelled":false,"archived":true,"archive_date":"2026-05-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/72f716b768cd4382ada9623a243b5814/view","enriched":true,"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}]},{"notice_id":"7b09923b9c854b6584d3cf36abb0a15d","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FA851726Q0002","notice_type":"o","base_type":"o","posted":"2026-04-03","posted_at":"2026-04-03T15:12:20.956Z","due_at":"2026-05-03T16:00:00Z","due_date":"2026-05-03","cancelled":false,"archived":true,"archive_date":"2026-05-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7b09923b9c854b6584d3cf36abb0a15d/view","enriched":true,"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}]},{"notice_id":"96850d0299f546de9d2edbbf98bf1efc","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FA851726Q0002","notice_type":"o","base_type":"p","posted":"2026-04-03","posted_at":"2026-04-03T11:25:27.211Z","due_at":"2026-05-03T16:00:00Z","due_date":"2026-05-03","cancelled":false,"archived":true,"archive_date":"2026-05-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/96850d0299f546de9d2edbbf98bf1efc/view","enriched":true,"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}]},{"notice_id":"7271d53516084e90b53b2ca21a4f85ed","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FA851726Q0002","notice_type":"o","base_type":"o","posted":"2026-05-05","posted_at":"2026-05-05T14:27:11.686Z","due_at":"2026-05-12T16:00:00Z","due_date":"2026-05-12","cancelled":false,"archived":true,"archive_date":"2026-05-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7271d53516084e90b53b2ca21a4f85ed/view","enriched":true,"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}]},{"notice_id":"ec8429488c7c4259a3b53b4d31a8f87e","title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","solicitation_number":"FA851726Q0002","notice_type":"o","base_type":"o","posted":"2026-05-19","posted_at":"2026-05-19T14:22:54.684Z","due_at":"2026-05-22T04:00:00Z","due_date":"2026-05-22","cancelled":false,"archived":true,"archive_date":"2026-06-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ec8429488c7c4259a3b53b4d31a8f87e/view","enriched":true,"history":[{"index":10,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-01T10:50:03.092Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"46fc1fb408e34604b6200c7a4753b42b","solicitation_number":"FA851727D0001","related_opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e"},{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}]}],"latest_notice_id":"ec8429488c7c4259a3b53b4d31a8f87e","first_type":"o","notices":[{"dates":{"posted":"2026-04-03","posted_at":"2026-04-03T12:23:21.522Z","created_at":"2026-04-03T12:19:45.522Z","modified_at":"2026-06-06T04:04:26.524Z","response_deadline":{"raw":"2026-05-03T12:00:00-04:00","utc":"2026-05-03T16:00:00Z","date":"2026-05-03","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/72f716b768cd4382ada9623a243b5814/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","agency":{"office":{"code":"FA8517","name":"FA8517 AFSC PZAAC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500039862","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-18","archive_type":"auto15"},"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}],"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"72f716b768cd4382ada9623a243b5814","lineage_id":"96850d0299f546de9d2edbbf98bf1efc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T03:39:06.596004616Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"791fe42168dc843f464877959989860b29a94279c313d96bbc8a925018dd7f71","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T03:39:06.596004616Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.&nbsp;</p>\n\n<p>This component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.</p>\n\n<p>The contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&amp;E first. Once TT&amp;E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>\n\n<p>The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&amp;E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>","text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThis component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThe contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&E first. Once TT&E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.\n\nThe repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA851726Q0002","place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4920"},{"dates":{"posted":"2026-04-03","posted_at":"2026-04-03T15:12:20.956Z","created_at":"2026-04-03T15:07:27.294Z","modified_at":"2026-06-06T04:04:26.524Z","response_deadline":{"raw":"2026-05-03T12:00:00-04:00","utc":"2026-05-03T16:00:00Z","date":"2026-05-03","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7b09923b9c854b6584d3cf36abb0a15d/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","agency":{"office":{"code":"FA8517","name":"FA8517 AFSC PZAAC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500039862","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-18","archive_type":"auto15"},"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}],"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"7b09923b9c854b6584d3cf36abb0a15d","lineage_id":"96850d0299f546de9d2edbbf98bf1efc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T03:40:51.364723044Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"91881f33a7f466b406bea04426a6e1bfa344a93a77bbee090855a53b9973ec7f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T03:40:51.364723044Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.&nbsp;</p>\n\n<p>This component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.</p>\n\n<p>The contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&amp;E first. Once TT&amp;E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>\n\n<p>The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&amp;E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>","text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThis component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThe contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&E first. Once TT&E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.\n\nThe repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA851726Q0002","place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4920"},{"dates":{"posted":"2026-04-03","posted_at":"2026-04-03T11:25:27.211Z","created_at":"2026-03-27T11:21:46.394Z","modified_at":"2026-06-06T04:04:26.524Z","response_deadline":{"raw":"2026-05-03T12:00:00-04:00","utc":"2026-05-03T16:00:00Z","date":"2026-05-03","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/96850d0299f546de9d2edbbf98bf1efc/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","agency":{"office":{"code":"FA8517","name":"FA8517 AFSC PZAAC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500039862","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-18","archive_type":"auto15"},"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}],"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"96850d0299f546de9d2edbbf98bf1efc","lineage_id":"96850d0299f546de9d2edbbf98bf1efc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T03:42:44.873527667Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"4ed797654b5e511aa318825f26abb29f95c4227d6ce73b3c22d15d4bc5ede644","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T03:42:44.873527667Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.&nbsp;</p>\n\n<p>This component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.</p>\n\n<p>The contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&amp;E first. Once TT&amp;E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>\n\n<p>The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&amp;E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>","text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThis component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThe contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&E first. Once TT&E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.\n\nThe repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA851726Q0002","place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4920"},{"dates":{"posted":"2026-05-05","posted_at":"2026-05-05T14:27:11.686Z","created_at":"2026-05-05T14:26:12.866Z","modified_at":"2026-06-06T04:04:26.524Z","response_deadline":{"raw":"2026-05-12T12:00:00-04:00","utc":"2026-05-12T16:00:00Z","date":"2026-05-12","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7271d53516084e90b53b2ca21a4f85ed/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","agency":{"office":{"code":"FA8517","name":"FA8517 AFSC PZAAC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500039862","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-27","archive_type":"auto15"},"history":[{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}],"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"7271d53516084e90b53b2ca21a4f85ed","lineage_id":"96850d0299f546de9d2edbbf98bf1efc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T07:41:00.973481117Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"ec53f6efe1814ffd83463276036ae97ea1c88ee57cda61b684735a049a37db2d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T07:41:00.973481117Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.&nbsp;</p>\n\n<p>This component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.</p>\n\n<p>The contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&amp;E first. Once TT&amp;E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>\n\n<p>The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&amp;E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>","text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThis component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThe contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&E first. Once TT&E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.\n\nThe repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA851726Q0002","place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4920"},{"dates":{"posted":"2026-05-19","posted_at":"2026-05-19T14:22:54.684Z","created_at":"2026-05-19T14:20:59.691Z","modified_at":"2026-06-06T04:04:26.524Z","response_deadline":{"raw":"2026-05-22T00:00:00-04:00","utc":"2026-05-22T04:00:00Z","date":"2026-05-22","time":"00:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ec8429488c7c4259a3b53b4d31a8f87e/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","agency":{"office":{"code":"FA8517","name":"FA8517 AFSC PZAAC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_id":"500039862","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-06","archive_type":"auto15"},"history":[{"index":10,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-01T10:50:03.092Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"46fc1fb408e34604b6200c7a4753b42b","solicitation_number":"FA851727D0001","related_opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e"},{"index":9,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T14:22:54.684Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ec8429488c7c4259a3b53b4d31a8f87e","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":7,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-05T14:27:11.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7271d53516084e90b53b2ca21a4f85ed","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":6,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T13:07:59.034Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92","solicitation_number":"FD20602700008"},{"index":4,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T15:12:20.956Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7b09923b9c854b6584d3cf36abb0a15d","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":3,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T12:23:21.522Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72f716b768cd4382ada9623a243b5814","solicitation_number":"FA851726Q0002","parent_opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"},{"index":2,"title":"REPAIR OF BLOWER ASSEMBLY NSN 4920011116824RN","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-03T11:25:27.211Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"96850d0299f546de9d2edbbf98bf1efc","solicitation_number":"FA851726Q0002","related_opportunity_id":"20e09e9956d94900b16cfa2bfc0dca92"}],"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ec8429488c7c4259a3b53b4d31a8f87e","lineage_id":"96850d0299f546de9d2edbbf98bf1efc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-03T08:51:12.002429024Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"8b199d0bd7c9bd2709a6ffc73d6c5c15243a3aef5e8f5494885fbacb04248188","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-03T08:51:12.002429024Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.&nbsp;</p>\n\n<p>This component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.</p>\n\n<p>The contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&amp;E first. Once TT&amp;E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>\n\n<p>The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&amp;E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>","text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThis component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThe contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&E first. Once TT&E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.\n\nThe repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA851726Q0002","place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4920"}],"due_at":"2026-05-22T04:00:00Z","due_date":"2026-05-22","closes_at":"2026-05-22T04:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8517","office_name":"FA8517 AFSC PZAAC","state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-03T09:21:27.620026Z","principal_notice_id":"ec8429488c7c4259a3b53b4d31a8f87e","description":{"text":"This requirement is for the Teardown/Test/Evaluation (TT&E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThis component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.\n\nThe contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&E first. Once TT&E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.\n\nThe repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.","html":"<p>This requirement is for the Teardown/Test/Evaluation (TT&amp;E) and repair of NSN 4920-01-111-6824RN, P/N 89162-204 Blower Assembly. This component is a single stage lobe blower with a positive displacement type unit whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor, used to furnish air at various pressures and flows to measure aircraft cabin leakage.&nbsp;</p>\n\n<p>This component is a single stage lobe blower, a positive displacement type unit, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs a single-lobe impeller within a cylinder closed at the ends by headplates. As the impellers rotate, air is drawn into one side of the cylinder and forced out the opposite side against the existing pressures. The Cabin Pressurized Leakage Tester unit is a self-contained portable diesel-powered unit seal compressor driven by a 12 VDC electric motor used to furnish air at various pressures and flows to measure aircraft cabin leakage.</p>\n\n<p>The contractor shall perform all actions necessary to return reparable items to a serviceable condition. The contractor shall perform TT&amp;E first. Once TT&amp;E is completed, the contractor shall then perform the repair and return of each item in a serviceable condition. Repairs shall be completed within the Turnaround Time (TAT) while also providing quality repair with low to no Product Quality Deficiency Reports (PQDR). On time delivery is required due to critical mission operations. If or when deficiencies occur, which should be low to none, the contractor shall expedite all efforts to rectify the errors with minimal delay or compromise of quality outcome. The delivery is a pertinent requirement due to critical mission operations. The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The repair will be conducted IAW applicable OCM specifications. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>\n\n<p>The repair is required to provide a serviceable component part that can efficiently serve its intended purpose. The TT&amp;E and repair will be conducted in accordance with (IAW) applicable Original Component Manufacturer (OCM) standards. Contractor personnel will perform maintenance IAW applicable OCM standards and directives.</p>","origin":"detail"},"contacts":[{"name":"Teresa Morris","role":"primary","email":"teresa.morris.2@us.af.mil"},{"name":"Steve Renfroe","role":"secondary","email":"Carlos.renfroe.1@us.af.mil"}],"place_of_performance":{"city":{"code":"80508","name":"Warner Robins"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"31098-1670","city":"ROBINS AFB","state":"GA","country":"USA"},"naics_codes":["811210"],"award":null,"attachments":[{"resource_id":"285cdf1fa7d14b50aad7913a7afec3a1","name":"4322003_TRNSPDATA_REPORT.pdf","kind":"file","mime_type":".pdf","size_bytes":90467,"posted_at":"2026-04-03T11:25:27.211Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/285cdf1fa7d14b50aad7913a7afec3a1/download","mirrored":false}],"awards":[],"related":[],"similar_open":[{"key":"FA857127Q0012","latest_notice_id":"7e9eedb22d6841709dc019ba3f04e0aa","title":"PCDMIS CAD++ Software Renewal and CMM Calibration","solicitation_number":"FA857127Q0012","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"811210","psc":"J066","set_aside":null,"state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"FA853826R0017","latest_notice_id":"3b037426d9cb41b9a93923a626fc3565","title":"Repair/Overhaul of Flat Panel Up Front Controller (FPUFC)","solicitation_number":"FA853826R0017","notice_type":"o","first_type":"p","first_posted":"2026-04-29","last_posted":"2026-09-29","notices":3,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"811210","psc":"J059","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-30T04:14:25.251125Z"},{"key":"36C24727Q0067","latest_notice_id":"f75d8541b0604a57a55c64094b365d82","title":"J065--Building 3 Dental Vacuum Pump Replacement","solicitation_number":"36C24727Q0067","notice_type":"k","first_type":"r","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":6,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"GA","county":"13175","county_name":"Laurens County","city":"1324376","city_name":"Dublin","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":65,"indexable":false}