Sources sought
LCO2 Tank
FA560626QA023
Department of the Air Force, FA5606 52 Cons Da LGC. Metal Tank (Heavy Gauge) Manufacturing.
Response deadline
April 10, 2026 at 4:00 AM EDT
Closed 229 days ago. Posted April 1, 2026. Scheduled to archive April 11, 2026.
Get the next one like this from Department of the Air Force by email, the day it is posted.Find my opportunities
This one closed in 2026
2 like it are open now in metal tank (heavy gauge) manufacturing
- CYLINDER,COMPRESSED
Department of the Navy, NAVSUP Weapon Systems Support
SolicitationNAICS 332420Ship to the buyerN0038326QSB78Due in 5 daysNov 30 - TANK,PRESSURE
Defense Logistics Agency, DLA Weapons Support
Combined synopsis and solicitationSDVOSBNAICS 332420Ship to the buyerSPE7L327U0076Closes in 10 daysDec 4
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 332420 (metal tank (heavy gauge) manufacturing), means no more than 750 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of April 1, 2026. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Spangdahlem AB is conducting market research for the below requirement. Be advised, this is NOT a solicitation, nor does it guarantee a solicitation for this requirement to be posted in the future.
This is an official request for information (RFI) to notify prospective offerors. Feedback is encouraged. Quotes are not currently being requested. Currently, there is no specialised foundation for the LCO2 tank to stand upon: is a specialised foundation required and if so, what specifications would such a foundation have to fulfill to safely support a long-term positioning of a LCO2 tank?
The purpose of this requirement is to provide a liquid CO2 storage tank with the following draft-requirements:
The tank should have a capacity of 6,000 - 7,000 liters and be a vacuum-insulated double wall tank consisting of two concentric vessels, a low-temperature resistant austenitic steel inner tank and an outer tank made of carbon steel with an anti-corrosion primer and a top coat of paint. The interspace between the two tanks should be filled with perlite insulating powder and an absorbent to maintain a vacuum pressure of < 0.05 millibar during tank operation. The maximum allowable working pressure for the inner vessel must be 22 bar gauge for temperatures ranging from -196° up to 20°C. It must supply pressurized LCO2 at 189-261 psi (13-18 bar) to a Dry Ice Production Hub through a flexible hose attachment. It will include a safety valve system to prevent overpressurizaton and a safety shutoff valve. The tank must be manufactured and tested in accordance with EU 97/23/EC and EN 13458. The company's Quality Management System must satisfy all elements of the EN ISO 9001/2000 program or ASME (U, U2, R-Stamp).
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 1, 2026
Sources sought
Due April 10, 2026 at 4:00 AM EDT. SAM.gov, notice 42987b71a60a4bdba29d29ec8dd5ceb3
1 revision on SAM
- April 1, 2026: publish, sources sought
Points of contact
- George Hydegeorge.hyde.de@us.af.mil00496565619549
- Christine Zacchettichristine.zacchetti.1.de@us.af.mil00496565619505