Sources sought
Relocatable Facilities
FA5570S0005
Department of the Air Force, FA5570 501 CSW Rco. Prefabricated Metal Building and Component Manufacturing.
Response deadline
June 12, 2025 at 11:00 AM EDT
Closed 531 days ago. Posted May 12, 2025. Scheduled to archive June 27, 2025.
Get the next one like this from Department of the Air Force by email, the day it is posted.Find my opportunities
This one closed in 2025
8 like it are open now in prefabricated metal building and component manufacturing
- Solicitation_S-280C/G Vehicle Mounted Shelter
Department of the Army, W6QK Acc- Dta
SolicitationSmall businessNAICS 332311Ship to the buyerW912CH-26-R-A096Closes in 56 daysJan 20, 2027 - 75150PR270000011 - MODIFIED CONEX CONTAINERS - USCG STATION POINT LOMA
US Coast Guard, Base La - Long Beach
Combined synopsis and solicitationNAICS 332311Ship to San Diego, CA75150PR270000011Due in 6 daysDec 1 - SCAFFOLDING AND CONTAINMENT FOR 49' BUSL
US Coast Guard, Cg-Sea-C23
Combined synopsis and solicitationSmall businessNAICS 332311Maryland70ZU0327Q60724Y00Closes in 9 daysDec 4
All 8 open in prefabricated metal building and component manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 332311 (prefabricated metal building and component manufacturing), means no more than 750 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of May 12, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
SOURCES SOUGHT FY25. The purpose of this synopsis is to conduct market research on potential sources for a future acquisition of Relocatable Facilities at RAF Fairford. This is not a request for competitive proposals or quotations, nor is it pre-qualification for any future solicitation for this work. It is anticipated that the following construction services will be required: construction, and installation of relocatable buildings and related site improvements at RAF Fairford to provide temporary facilities. The potential relocatable buildings are as follows:
4 bay 32ft x 20ft (9.7m x 6m) Double stack Ground floor and first floor open plan building. Complete with Lighting, Heating, Power points, and Rcd protected consumer unit. 16 x UPVC double glazed windows with shutters, 4 X steel external doors.
- 2 x New 13 tread steel stairs and platform. (One at each end of building.)
- 3 x 32ft x 10ft (9.7m x 3m) open plan/canteen units complete with Heating, Lighting, vinyl to floor, steel external door, double glazed sliding windows with shutters, Rcd protected consumer unit.
- 1 x 24ft x 10ft (7.3m x 3m) Open plan unit with 1 x steel external door, 2 x sliding windows with shutters, heating, lighting and Rcd protected consumer unit.
- 1 x 2 bay 20ft x 16ft (6m x 4.8m) open plan office unit complete with 2 x steel external doors, 4 x UPVC double glazed windows with roller shutter, heating, lighting and Rcd protected consumer unit.
- Delivery costs with hi-ab lorries to offload and position.
- Groundwork’s for above units to include 450mm x 450mm foundation pads on each corner of the building only. (Gravel not included around surrounds of building.)
.The project shall comply with UFC 1-200-01,
Potential sources must submit a capability statement of no more than 4 pages in length, which addresses the following key areas: (1) TECHNICAL - Potential sources must submit a list of recent projects that demonstrate their knowledge and past experience relating to all of the varying types of work described above, particularly in the areas of sitework and construction of relocatable facilities. Individual task orders under IDIQ contracts should be listed as separate projects. Submit only current and past project and client information that is no more than 4 years previous and include a brief description, identify the capacity the firm worked in on the project (prime or subcontractor), the contract type (list by task order if IDIQ), contract or task order value, dollar value of work subcontracted, percent complete, if complete date completed, name and title of customer POC and current phone number. (2) Geographical Location- Potential sources shall identify if they have a physical office in the United Kingdom.
All interested parties may respond or submit statements of qualifications. This is not a request for competitive proposals or quotations, nor a prequalification for any future contract for this work. A determination by the Government not to compete this proposed contract is within the discretion of the Government. All responses are due no later than 16:00 GMT on June 12, 2025. Please direct all questions to: Mr. Calin Moloiu Contract Specialist, phone (314) 268-3482, email address:calin.moloiu.gb@us.af.mil.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Salient Characterstics Modular Facilities..docx46 KB, May 12, 2025
- Attach 8 ufc_1_200_01 Building Standard.pdf435 KB, May 12, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 12, 2025
Sources sought
Due June 12, 2025 at 11:00 AM EDT. SAM.gov, notice c4b3189c28434b61bb3be3f136cf8ee4
1 revision on SAM
- May 12, 2025: publish, sources sought
Points of contact
- Aaron Ketzaaron.ketz@us.af.mil4401480843125
- 501st Regional Contracting Office501csw.rco@us.af.mil