{"canonical":"https://sealedbidder.com/opportunities/fa524025r0003","key":"FA524025R0003","url":"https://sealedbidder.com/opportunities/fa524025r0003","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-18T06:00:00Z","first_posted":"2025-05-07","last_posted":"2025-08-25","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA5240 36 CONS LGC","naics":"236220","psc":"Z2FC","set_aside":"HZC","place_state":"GU","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"66010","place_county_name":"Guam","place_city":null,"place_city_name":null,"winner":"SEA PAC ENGINEERING INC","award_amount":"34325690.00","publications":[{"notice_id":"4bfd865614754566bc3f2c61a6bcc24b","title":"AJJY 25-1073M Repair Rota Dormitory (B25017)","solicitation_number":"FA524025R0003","notice_type":"p","base_type":"p","posted":"2025-05-07","posted_at":"2025-05-08T00:16:14.251Z","due_at":"2025-05-23T04:00:00Z","due_date":"2025-05-23","cancelled":false,"archived":true,"archive_date":"2025-06-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4bfd865614754566bc3f2c61a6bcc24b/view","enriched":true,"history":[{"index":3,"title":"AJJY 25-1073M Repair Rota Dormitory (B25017)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-08T00:16:14.251Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4bfd865614754566bc3f2c61a6bcc24b","solicitation_number":"FA524025R0003"}]},{"notice_id":"7867c667c0a449e480c6fdc84342962d","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"o","base_type":"o","posted":"2025-06-13","posted_at":"2025-06-13T07:32:18.111Z","due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","cancelled":false,"archived":true,"archive_date":"2025-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7867c667c0a449e480c6fdc84342962d/view","enriched":true,"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}]},{"notice_id":"b62ecaabec6c46e581dfd1b030844534","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"o","base_type":"o","posted":"2025-06-13","posted_at":"2025-06-13T07:01:31.629Z","due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","cancelled":false,"archived":true,"archive_date":"2026-06-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b62ecaabec6c46e581dfd1b030844534/view","enriched":true,"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}]},{"notice_id":"ac37ca2dbf434a07a231cff5220d183c","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"o","base_type":"o","posted":"2025-07-11","posted_at":"2025-07-11T06:31:02.674Z","due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","cancelled":false,"archived":true,"archive_date":"2025-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ac37ca2dbf434a07a231cff5220d183c/view","enriched":true,"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}]},{"notice_id":"eb827a21c4b24771a9be37cc33dd3b5c","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"o","base_type":"o","posted":"2025-07-11","posted_at":"2025-07-11T06:40:34.955Z","due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","cancelled":false,"archived":true,"archive_date":"2025-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/eb827a21c4b24771a9be37cc33dd3b5c/view","enriched":true,"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}]},{"notice_id":"f11e33d549a64ef5bd7f946f4fab3415","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"o","base_type":"o","posted":"2025-07-11","posted_at":"2025-07-11T06:34:18.979Z","due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","cancelled":false,"archived":true,"archive_date":"2026-07-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f11e33d549a64ef5bd7f946f4fab3415/view","enriched":true,"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}]},{"notice_id":"227441da24534fa0b38f856097c88afc","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"o","base_type":"o","posted":"2025-07-15","posted_at":"2025-07-15T06:54:11.038Z","due_at":"2025-07-18T06:00:00Z","due_date":"2025-07-18","cancelled":false,"archived":true,"archive_date":"2025-08-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/227441da24534fa0b38f856097c88afc/view","enriched":true,"history":[{"index":12,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T23:01:07.214Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"e592f756a68e459799b5215f9cd56578","solicitation_number":"FA524025C0006","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":10,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T20:43:06.442Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"ab760553e2b043beb289da0e2787388e","solicitation_number":"FA524025R0003","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}]},{"notice_id":"ab760553e2b043beb289da0e2787388e","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025R0003","notice_type":"a","base_type":"o","posted":"2025-08-25","posted_at":"2025-08-25T20:43:06.442Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-09-10","removed_at":null,"award_number":"FA524025C0006","awardee_name":"SEA PAC ENGINEERING INC","amount":"34325690.00","link_sam":"https://sam.gov/workspace/contract/opp/ab760553e2b043beb289da0e2787388e/view","enriched":true,"history":[{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T20:43:06.442Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"ab760553e2b043beb289da0e2787388e","solicitation_number":"FA524025R0003","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"}]},{"notice_id":"e592f756a68e459799b5215f9cd56578","title":"AJJY 25-1073M Repair Rota Dorm B25017","solicitation_number":"FA524025C0006","notice_type":"a","base_type":"o","posted":"2025-08-25","posted_at":"2025-08-25T23:01:07.214Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-09-10","removed_at":null,"award_number":"FA24025C0006","awardee_name":"SEA PAC ENGINEERING INC","amount":"34325690.00","link_sam":"https://sam.gov/workspace/contract/opp/e592f756a68e459799b5215f9cd56578/view","enriched":true,"history":[{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T23:01:07.214Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"e592f756a68e459799b5215f9cd56578","solicitation_number":"FA524025C0006","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"}]}],"latest_notice_id":"e592f756a68e459799b5215f9cd56578","first_type":"p","notices":[{"dates":{"posted":"2025-05-07","posted_at":"2025-05-08T00:16:14.251Z","created_at":"2025-04-29T04:48:32.775Z","modified_at":"2025-06-07T04:04:37.694Z","response_deadline":{"raw":"2025-05-23T14:00:00+10:00","utc":"2025-05-23T04:00:00Z","date":"2025-05-23","time":"14:00:00","timezone":"Australia/Sydney","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4bfd865614754566bc3f2c61a6bcc24b/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dormitory (B25017)","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-07","archive_type":"auto15"},"history":[{"index":3,"title":"AJJY 25-1073M Repair Rota Dormitory (B25017)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-08T00:16:14.251Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4bfd865614754566bc3f2c61a6bcc24b","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna Gutierrez-Dejesus","role":"primary","email":"jianna.gutierrez_dejesus@us.af.mil"},{"name":"Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"4bfd865614754566bc3f2c61a6bcc24b","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"4bfd865614754566bc3f2c61a6bcc24b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-15T11:47:34.805580470Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"dc2ff32ac12e58460f447f580815123de2c2350f271953d603f1631bd6aa2790","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-15T11:47:34.805580470Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.</p>\n\n<p><strong>DESCRIPTION OF WORK:</strong></p>\n\n<p>The contractor shall&nbsp;design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.</p>\n\n<p></p>\n\n<p><strong>MAGNITUDE (FAR 36.204 &amp; DFARS 236.204):</strong></p>\n\n<p>$25,000,000 - $100,000,000</p>\n\n<p><br />\n<strong>LOCATION OF WORK:</strong></p>\n\n<p>Andersen AFB, Guam</p>\n\n<p><br />\n<strong>PERIOD OF PERFORMANCE:</strong></p>\n\n<p>864 Calendar Days</p>\n\n<p><br />\n<strong>TENTATIVE DATE OF ISSUE:</strong></p>\n\n<p>The solicitation number for this acquisition will be FA524025R0003 and will be available for retrieval at SAM.gov on or about 07 June 2025.</p>\n\n<p><br />\n<strong>RESTRICTION TO SMALL BUSINESS:</strong></p>\n\n<p>This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million. The eventual contract for this acquisition is contemplated to be Firm-Fixed Price (FFP).</p>\n\n<p><br />\n<strong>PLANS &amp; INSPECTION:</strong></p>\n\n<p>Available planning documentation will be provided in the solicitation. A pre-proposal site visit will be advertised in the solicitation.<br />\n&nbsp;</p>\n\n<p><strong>OTHER INFORMATION:</strong></p>\n\n<p>The solicitation for this acquisition will be issued electronically and will be publicized via SAM.gov. Interested offerors are responsible for retrieving a copy of the solicitation and all associated documents as no paper copies will be furnished. No offeror mailing list will be maintained. Interested offerors should register at the SAM.gov website to receive notification of any additions or changes to the publicized solicitation.</p>\n\n<p><br />\nInterested offerors are encouraged to submit their contact information by registering as an interested vendor, utilizing the &ldquo;Vendor Notification Service&rdquo; link within the &ldquo;Register to Receive Notification&rdquo; function. All offerors must be registered within the System for Award Management (SAM) database.</p>\n\n<p><br />\nOfferors may obtain information on registration and annual entity confirmation requirements at https://www.sam.gov. Additional information regarding the required registration and annual confirmation steps can be obtained from the Federal Service Desk (FSD) at https://www.fsd.gov, or by calling 1-800-606-8220.</p>\n\n<p><br />\nOffers in response to the publicized solicitation for this acquisition shall be submitted on the Standard Form 1442 (SF 1442) and must follow preparation instructions as listed within the solicitation. Any questions concerning the AJJY 25-1073M Repair Rota Dormitory B25017 solicitation or its contents must be submitted in writing to the point(s) of contact listed below via mail or email. Questions via telephone will not be accepted.</p>\n\n<p><br />\nProspective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.</p>\n\n<p><strong>Vendor Registration:</strong></p>\n\n<p>https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf<br />\n&nbsp;</p>\n\n<p><strong>Solicitation Module Training:</strong></p>\n\n<p>https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml</p>\n\n<p></p>\n\n<p><strong>NOTICE TO OFFERORS:</strong></p>\n\n<p>The Government reserves the right to cancel this solicitation, either before or after closing of receipt of proposals.</p>\n\n<p>This will be added on the SAM site itself.</p>\n\n<p><br />\n<strong>GOVERNMENT POINTS OF CONTACT:&nbsp;</strong></p>\n\n<p>SrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil</p>\n\n<p>Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil</p>\n\n<p>Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil</p>","text":"Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.\n\nDESCRIPTION OF WORK:\n\nThe contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.\n\nMAGNITUDE (FAR 36.204 & DFARS 236.204):\n\n$25,000,000 - $100,000,000\n\nLOCATION OF WORK:\n\nAndersen AFB, Guam\n\nPERIOD OF PERFORMANCE:\n\n864 Calendar Days\n\nTENTATIVE DATE OF ISSUE:\n\nThe solicitation number for this acquisition will be FA524025R0003 and will be available for retrieval at SAM.gov on or about 07 June 2025.\n\nRESTRICTION TO SMALL BUSINESS:\n\nThis acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million. The eventual contract for this acquisition is contemplated to be Firm-Fixed Price (FFP).\n\nPLANS & INSPECTION:\n\nAvailable planning documentation will be provided in the solicitation. A pre-proposal site visit will be advertised in the solicitation.\n\nOTHER INFORMATION:\n\nThe solicitation for this acquisition will be issued electronically and will be publicized via SAM.gov. Interested offerors are responsible for retrieving a copy of the solicitation and all associated documents as no paper copies will be furnished. No offeror mailing list will be maintained. Interested offerors should register at the SAM.gov website to receive notification of any additions or changes to the publicized solicitation.\n\nInterested offerors are encouraged to submit their contact information by registering as an interested vendor, utilizing the “Vendor Notification Service” link within the “Register to Receive Notification” function. All offerors must be registered within the System for Award Management (SAM) database.\n\nOfferors may obtain information on registration and annual entity confirmation requirements at https://www.sam.gov. Additional information regarding the required registration and annual confirmation steps can be obtained from the Federal Service Desk (FSD) at https://www.fsd.gov, or by calling 1-800-606-8220.\n\nOffers in response to the publicized solicitation for this acquisition shall be submitted on the Standard Form 1442 (SF 1442) and must follow preparation instructions as listed within the solicitation. Any questions concerning the AJJY 25-1073M Repair Rota Dormitory B25017 solicitation or its contents must be submitted in writing to the point(s) of contact listed below via mail or email. Questions via telephone will not be accepted.\n\nProspective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.\n\nVendor Registration:\n\nhttps://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf\n\nSolicitation Module Training:\n\nhttps://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml\n\nNOTICE TO OFFERORS:\n\nThe Government reserves the right to cancel this solicitation, either before or after closing of receipt of proposals.\n\nThis will be added on the SAM site itself.\n\nGOVERNMENT POINTS OF CONTACT:\n\nSrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil\n\nMr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil\n\nMs. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2FC"},{"dates":{"posted":"2025-06-13","posted_at":"2025-06-13T07:32:18.111Z","created_at":"2025-06-13T07:02:51.218Z","modified_at":"2025-08-02T04:04:39.073Z","response_deadline":{"raw":"2025-07-16T16:00:00+10:00","utc":"2025-07-16T06:00:00Z","date":"2025-07-16","time":"16:00:00","timezone":"Australia/Sydney","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7867c667c0a449e480c6fdc84342962d/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-31","archive_type":"auto15"},"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna GUTIERREZ DEJESUS","role":"primary","email":"Jianna.gutierrez_dejesus@us.af.mil","phone":"671-366-6417"},{"name":"Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"7867c667c0a449e480c6fdc84342962d","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T14:13:45.325708662Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"513393ac9ce6a8fc8d8d856707c032398c559c3bce3d69243d2731d7eab18d7e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T14:13:45.325708662Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.</p>\n\n<p></p>\n\n<p><u>DESCRIPTION OF WORK</u>:</p>\n\n<p>The contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.</p>\n\n<p></p>\n\n<p><u>MAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]</u></p>\n\n<p>The magnitude of this project is between $25,000,000 - $100,000,000</p>\n\n<p></p>\n\n<p><u>LOCATION OF WORK:</u></p>\n\n<p>Andersen AFB, GU</p>\n\n<p></p>\n\n<p><u>PERIOD OF PERFORMANCE:</u></p>\n\n<p>864 Calendar Days</p>\n\n<p></p>\n\n<p><u>RESTRICTION TO SMALL BUSINESS:</u></p>\n\n<p>This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.</p>\n\n<p></p>\n\n<p><u>CONTRACT TYPE:</u></p>\n\n<p>Firm Fixed Price (FFP)</p>\n\n<p></p>\n\n<p><u>SITE VISIT:</u></p>\n\n<p>Thursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)</p>\n\n<p></p>\n\n<p><u>REQUEST FOR INFORMATION:</u></p>\n\n<p>Any Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.</p>\n\n<p>All questions will be answered via Q&amp;A format and amended into the solicitation. It is the offeror&#39;s responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.</p>\n\n<p></p>\n\n<p><u>PROPOSAL SUBMISSION:</u></p>\n\n<p>Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).</p>\n\n<p>https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&amp;noticeType=SolicitationNotice</p>\n\n<p></p>\n\n<p><u>OTHER INFORMATION:</u></p>\n\n<p>Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.</p>\n\n<p>Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf</p>\n\n<p>Solicitation Module Training:</p>\n\n<p>https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml</p>\n\n<p></p>\n\n<p><u>NOTICE TO OFFERORS:</u></p>\n\n<p>The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.</p>\n\n<p></p>\n\n<p><u>GOVERNMENT POINTS OF CONTACT:</u></p>\n\n<p>SrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil</p>\n\n<p>Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil</p>\n\n<p>Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil</p>\n\n<p><u>(End of SAM Solicitation Posting)</u></p>","text":"Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.\n\nDESCRIPTION OF WORK:\n\nThe contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.\n\nMAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]\n\nThe magnitude of this project is between $25,000,000 - $100,000,000\n\nLOCATION OF WORK:\n\nAndersen AFB, GU\n\nPERIOD OF PERFORMANCE:\n\n864 Calendar Days\n\nRESTRICTION TO SMALL BUSINESS:\n\nThis acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.\n\nCONTRACT TYPE:\n\nFirm Fixed Price (FFP)\n\nSITE VISIT:\n\nThursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)\n\nREQUEST FOR INFORMATION:\n\nAny Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.\n\nAll questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.\n\nPROPOSAL SUBMISSION:\n\nProposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).\n\nhttps://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&noticeType=SolicitationNotice\n\nOTHER INFORMATION:\n\nProspective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.\n\nVendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf\n\nSolicitation Module Training:\n\nhttps://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml\n\nNOTICE TO OFFERORS:\n\nThe Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.\n\nGOVERNMENT POINTS OF CONTACT:\n\nSrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil\n\nMr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil\n\nMs. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil\n\n(End of SAM Solicitation Posting)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"street":"Andersen AFB, Guam","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2FC"},{"dates":{"posted":"2025-06-13","posted_at":"2025-06-13T07:01:31.629Z","created_at":"2025-06-13T07:01:31.557Z","modified_at":"2025-08-02T04:04:39.073Z","response_deadline":{"raw":"2025-07-16T16:00:00+10:00","utc":"2025-07-16T06:00:00Z","date":"2025-07-16","time":"16:00:00","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b62ecaabec6c46e581dfd1b030844534/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-13","archive_type":"auto_custom"},"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna GUTIERREZ DEJESUS","role":"primary","email":"Jianna.gutierrez_dejesus@us.af.mil","phone":"671-366-6417"},{"name":"CHUCK DAVID FLORES","role":"secondary","email":"chuck_david.flores@us.af.mil","phone":"6713662355"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"b62ecaabec6c46e581dfd1b030844534","lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T14:31:50.153769779Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"f006e4cde7dd977485d2e9951a92404a4a7dfaa78d5d11f2155e02f6cee0d268","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T14:31:50.153769779Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"AJJY 25-1073M Repair Rota Dorm B25017","text":"AJJY 25-1073M Repair Rota Dorm B25017","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","street":"Andersen AFB, Guam"},"product_service_code":"Z2JZ"},{"dates":{"posted":"2025-07-11","posted_at":"2025-07-11T06:31:02.674Z","created_at":"2025-07-11T05:14:34.614Z","modified_at":"2025-08-02T04:04:39.073Z","response_deadline":{"raw":"2025-07-16T16:00:00+10:00","utc":"2025-07-16T06:00:00Z","date":"2025-07-16","time":"16:00:00","timezone":"Australia/Sydney","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ac37ca2dbf434a07a231cff5220d183c/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-31","archive_type":"auto15"},"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna GUTIERREZ DEJESUS","role":"primary","email":"Jianna.gutierrez_dejesus@us.af.mil","phone":"671-366-6417"},{"name":"Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ac37ca2dbf434a07a231cff5220d183c","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-10T03:19:18.572527923Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"333d83a7d23dfb5526b38ada94fc19962270dce34050ed19fec676837690692e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-10T03:19:18.572527923Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.</p>\n\n<p></p>\n\n<p><u>DESCRIPTION OF WORK</u>:</p>\n\n<p>The contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.</p>\n\n<p></p>\n\n<p><u>MAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]</u></p>\n\n<p>The magnitude of this project is between $25,000,000 - $100,000,000</p>\n\n<p></p>\n\n<p><u>LOCATION OF WORK:</u></p>\n\n<p>Andersen AFB, GU</p>\n\n<p></p>\n\n<p><u>PERIOD OF PERFORMANCE:</u></p>\n\n<p>864 Calendar Days</p>\n\n<p></p>\n\n<p><u>RESTRICTION TO SMALL BUSINESS:</u></p>\n\n<p>This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.</p>\n\n<p></p>\n\n<p><u>CONTRACT TYPE:</u></p>\n\n<p>Firm Fixed Price (FFP)</p>\n\n<p></p>\n\n<p><u>SITE VISIT:</u></p>\n\n<p>Thursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)</p>\n\n<p></p>\n\n<p><u>REQUEST FOR INFORMATION:</u></p>\n\n<p>Any Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.</p>\n\n<p>All questions will be answered via Q&amp;A format and amended into the solicitation. It is the offeror&#39;s responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.</p>\n\n<p></p>\n\n<p><u>PROPOSAL SUBMISSION:</u></p>\n\n<p>Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).</p>\n\n<p>https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&amp;noticeType=SolicitationNotice</p>\n\n<p></p>\n\n<p><u>OTHER INFORMATION:</u></p>\n\n<p>Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.</p>\n\n<p>Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf</p>\n\n<p>Solicitation Module Training:</p>\n\n<p>https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml</p>\n\n<p></p>\n\n<p><u>NOTICE TO OFFERORS:</u></p>\n\n<p>The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.</p>\n\n<p></p>\n\n<p><u>GOVERNMENT POINTS OF CONTACT:</u></p>\n\n<p>SrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil</p>\n\n<p>Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil</p>\n\n<p>Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil</p>\n\n<p><u>(End of SAM Solicitation Posting)</u></p>","text":"Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.\n\nDESCRIPTION OF WORK:\n\nThe contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.\n\nMAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]\n\nThe magnitude of this project is between $25,000,000 - $100,000,000\n\nLOCATION OF WORK:\n\nAndersen AFB, GU\n\nPERIOD OF PERFORMANCE:\n\n864 Calendar Days\n\nRESTRICTION TO SMALL BUSINESS:\n\nThis acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.\n\nCONTRACT TYPE:\n\nFirm Fixed Price (FFP)\n\nSITE VISIT:\n\nThursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)\n\nREQUEST FOR INFORMATION:\n\nAny Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.\n\nAll questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.\n\nPROPOSAL SUBMISSION:\n\nProposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).\n\nhttps://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&noticeType=SolicitationNotice\n\nOTHER INFORMATION:\n\nProspective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.\n\nVendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf\n\nSolicitation Module Training:\n\nhttps://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml\n\nNOTICE TO OFFERORS:\n\nThe Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.\n\nGOVERNMENT POINTS OF CONTACT:\n\nSrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil\n\nMr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil\n\nMs. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil\n\n(End of SAM Solicitation Posting)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"street":"Andersen AFB, Guam","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2FC"},{"dates":{"posted":"2025-07-11","posted_at":"2025-07-11T06:40:34.955Z","created_at":"2025-07-11T06:35:04.991Z","modified_at":"2025-08-02T04:04:39.073Z","response_deadline":{"raw":"2025-07-16T16:00:00+10:00","utc":"2025-07-16T06:00:00Z","date":"2025-07-16","time":"16:00:00","timezone":"Australia/Sydney","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/eb827a21c4b24771a9be37cc33dd3b5c/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-31","archive_type":"auto15"},"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna GUTIERREZ DEJESUS","role":"primary","email":"Jianna.gutierrez_dejesus@us.af.mil","phone":"671-366-6417"},{"name":"Mr. Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"eb827a21c4b24771a9be37cc33dd3b5c","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-10T03:28:32.703557356Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"6fc7bf234d65121ce5e8387b909d4911ba428f07521611c2b6b7155e60f877aa","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-10T03:28:32.703557356Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.</p>\n\n<p>DESCRIPTION OF WORK:</p>\n\n<p>The contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.</p>\n\n<p>MAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]</p>\n\n<p>The magnitude of this project is between $25,000,000 - $100,000,000</p>\n\n<p>LOCATION OF WORK:</p>\n\n<p>Andersen AFB, GU</p>\n\n<p>PERIOD OF PERFORMANCE:</p>\n\n<p>864 Calendar Days</p>\n\n<p>RESTRICTION TO SMALL BUSINESS:</p>\n\n<p>This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.</p>\n\n<p>CONTRACT TYPE:</p>\n\n<p>Firm Fixed Price (FFP)</p>\n\n<p>SITE VISIT:</p>\n\n<p>Thursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)</p>\n\n<p>REQUEST FOR INFORMATION:</p>\n\n<p>Any Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.</p>\n\n<p>All questions will be answered via Q&amp;A format and amended into the solicitation. It is the offeror&#39;s responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.</p>\n\n<p>PROPOSAL SUBMISSION:</p>\n\n<p>Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).</p>\n\n<p>https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&amp;noticeType=SolicitationNotice</p>\n\n<p>OTHER INFORMATION:</p>\n\n<p>Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.</p>\n\n<p>Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf</p>\n\n<p>Solicitation Module Training:</p>\n\n<p>https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml</p>\n\n<p>NOTICE TO OFFERORS:</p>\n\n<p>The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.</p>\n\n<p>GOVERNMENT POINTS OF CONTACT:</p>\n\n<p>SrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil</p>\n\n<p>Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil</p>\n\n<p>Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil</p>\n\n<p>(End of SAM Solicitation Posting)</p>","text":"Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.\n\nDESCRIPTION OF WORK:\n\nThe contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.\n\nMAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]\n\nThe magnitude of this project is between $25,000,000 - $100,000,000\n\nLOCATION OF WORK:\n\nAndersen AFB, GU\n\nPERIOD OF PERFORMANCE:\n\n864 Calendar Days\n\nRESTRICTION TO SMALL BUSINESS:\n\nThis acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.\n\nCONTRACT TYPE:\n\nFirm Fixed Price (FFP)\n\nSITE VISIT:\n\nThursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)\n\nREQUEST FOR INFORMATION:\n\nAny Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.\n\nAll questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.\n\nPROPOSAL SUBMISSION:\n\nProposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).\n\nhttps://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&noticeType=SolicitationNotice\n\nOTHER INFORMATION:\n\nProspective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.\n\nVendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf\n\nSolicitation Module Training:\n\nhttps://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml\n\nNOTICE TO OFFERORS:\n\nThe Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.\n\nGOVERNMENT POINTS OF CONTACT:\n\nSrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil\n\nMr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil\n\nMs. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil\n\n(End of SAM Solicitation Posting)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"street":"Andersen AFB, Guam","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2JZ"},{"dates":{"posted":"2025-07-11","posted_at":"2025-07-11T06:34:18.979Z","created_at":"2025-07-11T06:34:17.656Z","modified_at":"2025-08-02T04:04:39.073Z","response_deadline":{"raw":"2025-07-16T16:00:00+10:00","utc":"2025-07-16T06:00:00Z","date":"2025-07-16","time":"16:00:00","timezone":"Australia/Sydney","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f11e33d549a64ef5bd7f946f4fab3415/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-11","archive_type":"auto_custom"},"history":[{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna GUTIERREZ DEJESUS","role":"primary","email":"Jianna.gutierrez_dejesus@us.af.mil","phone":"671-366-6417"},{"name":"CHUCK DAVID FLORES","role":"secondary","email":"chuck_david.flores@us.af.mil","phone":"6713662355"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"f11e33d549a64ef5bd7f946f4fab3415","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-10T03:30:13.703989184Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"ec63e1f2390bb9d75b7bdb9d22ad6e474e1ff815a165565b0bfe80eaac9be680","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-10T03:30:13.703989184Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"AJJY 25-1073M Repair Rota Dorm B25017","text":"AJJY 25-1073M Repair Rota Dorm B25017","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"street":"Andersen AFB, Guam","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2JZ"},{"dates":{"posted":"2025-07-15","posted_at":"2025-07-15T06:54:11.038Z","created_at":"2025-07-15T06:47:16.013Z","modified_at":"2025-08-02T04:04:39.073Z","response_deadline":{"raw":"2025-07-18T16:00:00+10:00","utc":"2025-07-18T06:00:00Z","date":"2025-07-18","time":"16:00:00","timezone":"Australia/Sydney","utc_offset_seconds":36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/227441da24534fa0b38f856097c88afc/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-02","archive_type":"auto15"},"history":[{"index":12,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T23:01:07.214Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"e592f756a68e459799b5215f9cd56578","solicitation_number":"FA524025C0006","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":10,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T20:43:06.442Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"ab760553e2b043beb289da0e2787388e","solicitation_number":"FA524025R0003","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":7,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:40:34.955Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eb827a21c4b24771a9be37cc33dd3b5c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":4,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:34:18.979Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f11e33d549a64ef5bd7f946f4fab3415","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":3,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-11T06:31:02.674Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ac37ca2dbf434a07a231cff5220d183c","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:32:18.111Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"7867c667c0a449e480c6fdc84342962d","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"},{"index":1,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T07:01:31.629Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"b62ecaabec6c46e581dfd1b030844534","solicitation_number":"FA524025R0003"}],"contacts":[{"name":"Jianna GUTIERREZ DEJESUS","role":"primary","email":"Jianna.gutierrez_dejesus@us.af.mil","phone":"671-366-6417"},{"name":"Mr. Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"227441da24534fa0b38f856097c88afc","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-10T00:58:34.047207500Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"3c397151ec634a24bfe03cef13b74f397041779b5f0290a792b03c37bf42ccdc","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-10T00:58:34.047207500Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.</p>\n\n<p>DESCRIPTION OF WORK:</p>\n\n<p>The contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.</p>\n\n<p>MAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]</p>\n\n<p>The magnitude of this project is between $25,000,000 - $100,000,000</p>\n\n<p>LOCATION OF WORK:</p>\n\n<p>Andersen AFB, GU</p>\n\n<p>PERIOD OF PERFORMANCE:</p>\n\n<p>864 Calendar Days</p>\n\n<p>RESTRICTION TO SMALL BUSINESS:</p>\n\n<p>This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.</p>\n\n<p>CONTRACT TYPE:</p>\n\n<p>Firm Fixed Price (FFP)</p>\n\n<p>SITE VISIT:</p>\n\n<p>Thursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)</p>\n\n<p>REQUEST FOR INFORMATION:</p>\n\n<p>Any Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.</p>\n\n<p>All questions will be answered via Q&amp;A format and amended into the solicitation. It is the offeror&#39;s responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.</p>\n\n<p>PROPOSAL SUBMISSION:</p>\n\n<p>Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).</p>\n\n<p>https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&amp;noticeType=SolicitationNotice</p>\n\n<p>OTHER INFORMATION:</p>\n\n<p>Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.</p>\n\n<p>Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf</p>\n\n<p>Solicitation Module Training:</p>\n\n<p>https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml</p>\n\n<p>NOTICE TO OFFERORS:</p>\n\n<p>The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.</p>\n\n<p>GOVERNMENT POINTS OF CONTACT:</p>\n\n<p>SrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil</p>\n\n<p>Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil</p>\n\n<p>Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil</p>\n\n<p>(End of SAM Solicitation Posting)</p>","text":"Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Rota Dormitory B25017.\n\nDESCRIPTION OF WORK:\n\nThe contractor shall design and fully repair Rota Dorm (B25017) which includes renovation of interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems in the Rota dorm. Rota is conditioned by a chilled water and a central chiller plant- both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. The Rota dorm must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets are buried with debris, dirt, and grass- these are to be cleared.\n\nMAGNITUDE [FAR 36.204(h) and DFARS 236.204(ii)]\n\nThe magnitude of this project is between $25,000,000 - $100,000,000\n\nLOCATION OF WORK:\n\nAndersen AFB, GU\n\nPERIOD OF PERFORMANCE:\n\n864 Calendar Days\n\nRESTRICTION TO SMALL BUSINESS:\n\nThis acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million.\n\nCONTRACT TYPE:\n\nFirm Fixed Price (FFP)\n\nSITE VISIT:\n\nThursday, 26 June 2025 at 0900 hours ChST (See Solicitation Section L)\n\nREQUEST FOR INFORMATION:\n\nAny Requests for Information (RFIs) regarding this solicitation are due on or before Monday, 07 July 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline.\n\nAll questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0003, AJJY 25-1073M Repair Rota Dorm B25017.\n\nPROPOSAL SUBMISSION:\n\nProposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8).\n\nhttps://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&noticeType=SolicitationNotice\n\nOTHER INFORMATION:\n\nProspective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below.\n\nVendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf\n\nSolicitation Module Training:\n\nhttps://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml\n\nNOTICE TO OFFERORS:\n\nThe Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids.\n\nGOVERNMENT POINTS OF CONTACT:\n\nSrA Jianna Gutierrez-Dejesus; Email: jianna.gutierrez_dejesus@us.af.mil\n\nMr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil\n\nMs. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil\n\n(End of SAM Solicitation Posting)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"street":"Andersen AFB, Guam","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2JZ"},{"award":{"date":"2025-08-26","amount":"34325690.00","number":"FA524025C0006","awardee":{"raw":"SEA PAC ENGINEERING INC Los Angeles CA 90005 USA","uei":"TSU2GQSJCGK7","cage":"04EN7","name":"SEA PAC ENGINEERING INC","location":{"zip":"90005","city":{"code":"44000","name":"Los Angeles"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2025-08-25","posted_at":"2025-08-25T20:43:06.442Z","award_date":"2025-08-26","created_at":"2025-08-25T20:35:15.667Z","modified_at":"2025-09-11T03:55:55.293Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/ab760553e2b043beb289da0e2787388e/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-10","archive_type":"auto15"},"history":[{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T20:43:06.442Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"ab760553e2b043beb289da0e2787388e","solicitation_number":"FA524025R0003","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"}],"contacts":[{"name":"Maria Christina Yalung","role":"primary","email":"maria_christina.yalung.1@us.af.mil","phone":"6713661710"},{"name":"Mr. Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ab760553e2b043beb289da0e2787388e","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T01:05:15.001984104Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"342aeac09669d0efac6842e633f2dfef0aebcbf6cc3de3213b779e59aa301600","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-03T01:05:15.001984104Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>This is a pre-award notice for Solicitation FA524025R0003: AJJY 25-1073M Repair Rota Dorm B25017, Andersen Air Force Base, Guam.</p>","text":"This is a pre-award notice for Solicitation FA524025R0003: AJJY 25-1073M Repair Rota Dorm B25017, Andersen Air Force Base, Guam.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"FA524025R0003","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2FC"},{"award":{"date":"2025-08-26","amount":"34325690.00","number":"FA24025C0006","awardee":{"raw":"SEA PAC ENGINEERING INC Los Angeles CA 90005 USA","uei":"TSU2GQSJCGK7","cage":"04EN7","name":"SEA PAC ENGINEERING INC","location":{"zip":"90005","city":{"code":"44000","name":"Los Angeles"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2025-08-25","posted_at":"2025-08-25T23:01:07.214Z","award_date":"2025-08-26","created_at":"2025-08-25T22:55:24.721Z","modified_at":"2025-09-11T03:55:55.293Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/e592f756a68e459799b5215f9cd56578/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"AJJY 25-1073M Repair Rota Dorm B25017","agency":{"office":{"code":"FA5240","name":"FA5240 36 CONS LGC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"organization_id":"100272386","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-10","archive_type":"auto15"},"history":[{"index":5,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T23:01:07.214Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"e592f756a68e459799b5215f9cd56578","solicitation_number":"FA524025C0006","related_opportunity_id":"227441da24534fa0b38f856097c88afc"},{"index":2,"title":"AJJY 25-1073M Repair Rota Dorm B25017","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-15T06:54:11.038Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"227441da24534fa0b38f856097c88afc","solicitation_number":"FA524025R0003","parent_opportunity_id":"b62ecaabec6c46e581dfd1b030844534"}],"contacts":[{"name":"Maria Christina Yalung","role":"primary","email":"maria_christina.yalung.1@us.af.mil","phone":"6713661710"},{"name":"Mr. Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"e592f756a68e459799b5215f9cd56578","set_aside":{"code":"HZC","label":"HUBZone Set-Aside (FAR 19.13)"},"lineage_id":"b62ecaabec6c46e581dfd1b030844534","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T01:25:25.104662798Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"0e65d23d14374b14ba2662e5fe36ebe58cb4aa88fd00d76e231bc79661c067a0","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-03T01:25:25.104662798Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>This is a post-award notice for solicitation FA524025R0003: AJJY 25-1073M Repair Rota Dorm B25017, Andersen Air Force Base, Guam.</p>","text":"This is a post-award notice for solicitation FA524025R0003: AJJY 25-1073M Repair Rota Dorm B25017, Andersen Air Force Base, Guam.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"FA524025C0006","place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2FC"}],"due_at":"2025-07-18T06:00:00Z","due_date":"2025-07-18","closes_at":"2025-07-18T06:00:00Z","awardable":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5240","office_name":"FA5240 36 CONS LGC","state":"GU","county":"66010","county_name":"Guam","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"TSU2GQSJCGK7","amount":"34325690.00","linked_awards":9,"cancelled":false,"archived":true,"updated_at":"2026-11-03T01:38:15.937744Z","principal_notice_id":"e592f756a68e459799b5215f9cd56578","description":{"text":"This is a post-award notice for solicitation FA524025R0003: AJJY 25-1073M Repair Rota Dorm B25017, Andersen Air Force Base, Guam.","html":"<p>This is a post-award notice for solicitation FA524025R0003: AJJY 25-1073M Repair Rota Dorm B25017, Andersen Air Force Base, Guam.</p>","origin":"detail"},"contacts":[{"name":"Maria Christina Yalung","role":"primary","email":"maria_christina.yalung.1@us.af.mil","phone":"6713661710"},{"name":"Mr. Eddie Pelkey","role":"secondary","email":"eddie.pelkey@us.af.mil","phone":"671-366-6576"}],"place_of_performance":{"zip":"96929","city":{"code":"82650","name":"Yigo"},"state":{"code":"GU","name":"Guam"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"96543-4040","city":"APO","state":"AP","country":"USA"},"naics_codes":["236220"],"award":{"date":"2025-08-26","amount":"34325690.00","number":"FA24025C0006","awardee":{"raw":"SEA PAC ENGINEERING INC Los Angeles CA 90005 USA","uei":"TSU2GQSJCGK7","cage":"04EN7","name":"SEA PAC ENGINEERING INC","location":{"zip":"90005","city":{"code":"44000","name":"Los Angeles"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"a5d2c21868054edabdaba2fa1cd5493b","name":"Department of Defense Procurement Toolbox","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-13T07:01:31.629Z","export_controlled":false,"sha256":null,"url":"https://dodprocurementtoolbox.com/","mirrored":false},{"resource_id":"25adbfed6a88432abf4be4d140beb8b3","name":"Post-Award Notice.pdf","kind":"file","mime_type":".pdf","size_bytes":191175,"posted_at":"2025-08-25T23:01:07.214Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/25adbfed6a88432abf4be4d140beb8b3/download","mirrored":false},{"resource_id":"716d3509cfdf487396f4ba43d51a7ea1","name":"Pre-Award Notice_26 Aug 25.pdf","kind":"file","mime_type":".pdf","size_bytes":148979,"posted_at":"2025-08-25T20:43:06.442Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/716d3509cfdf487396f4ba43d51a7ea1/download","mirrored":false},{"resource_id":"7b64554610f04cffa409648cfe2ad59d","name":"Registration Instructions for the PIEE Solicitation Module","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-13T07:01:31.629Z","export_controlled":false,"sha256":null,"url":"https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf","mirrored":false},{"resource_id":"b2da84d17f2644aaabab5940066ebe7b","name":"Web Based Training for the PIEE Solicitation Module","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-13T07:01:31.629Z","export_controlled":false,"sha256":null,"url":"https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml","mirrored":false},{"resource_id":"b2baf4c2865b452f950a2b27db708f0f","name":"PIEE Solicitation Module Link for FA524025R0003","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-13T07:01:31.629Z","export_controlled":false,"sha256":null,"url":"https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0003&noticeType=SolicitationNotice","mirrored":false},{"resource_id":"28adb75dd86a4ca2a73de48925ec1d22","name":"Att. 08_PIEE Proposal Manager Reference Guide.pdf","kind":"file","mime_type":".pdf","size_bytes":256142,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/28adb75dd86a4ca2a73de48925ec1d22/download","mirrored":false},{"resource_id":"f06d2afdcd7d4678a3e51215ffe63c74","name":"Att. 07_Common Construction Prevailing Wage Rates Guam.pdf","kind":"file","mime_type":".pdf","size_bytes":248092,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f06d2afdcd7d4678a3e51215ffe63c74/download","mirrored":false},{"resource_id":"ce3a88e6a20540b8b4cebddeff17e9cf","name":"Att. 06_Wage Determination (GU20250001).pdf","kind":"file","mime_type":".pdf","size_bytes":151964,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ce3a88e6a20540b8b4cebddeff17e9cf/download","mirrored":false},{"resource_id":"f269f3b8a42c466880f7bd7b7ff2614f","name":"Att. 05_AAFB IFS_27Feb24.pdf","kind":"file","mime_type":".pdf","size_bytes":64920323,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f269f3b8a42c466880f7bd7b7ff2614f/download","mirrored":false},{"resource_id":"0a87ef063d924909a5dd90db96ab815d","name":"Att. 03_Past Performance Fact Sheet.docx","kind":"file","mime_type":".docx","size_bytes":39367,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0a87ef063d924909a5dd90db96ab815d/download","mirrored":false},{"resource_id":"9e78de247d954d3a8fa678d79f9b9bd0","name":"Att. 02_Project Requirement Price Schedule.docx","kind":"file","mime_type":".docx","size_bytes":19963,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9e78de247d954d3a8fa678d79f9b9bd0/download","mirrored":false},{"resource_id":"5054ae03f4f5428c80d140b5969c36e0","name":"Att. 1H._Cat Management 4 - HVAC Standardization Policy Guidance Memorandums.pdf","kind":"file","mime_type":".pdf","size_bytes":1204378,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5054ae03f4f5428c80d140b5969c36e0/download","mirrored":false},{"resource_id":"57cad63a2b304ffa90862a73fcae909f","name":"Att. 1G._USAF Fire Alarm Panel Approval Memorandum.pdf","kind":"file","mime_type":".pdf","size_bytes":226255,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/57cad63a2b304ffa90862a73fcae909f/download","mirrored":false},{"resource_id":"f47de20e417a4794a1b053d8bf2d27b1","name":"Att. 1F._Lead and Asbestos Inspection Report RPR Rota Dorm B25017.pdf","kind":"file","mime_type":".pdf","size_bytes":244325,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f47de20e417a4794a1b053d8bf2d27b1/download","mirrored":false},{"resource_id":"c2101fca2c714ca5a668327abc685888","name":"Att. 1E._AJJY251073M RPR Rota Dorm B25017 35_ Concept DSN.pdf","kind":"file","mime_type":".pdf","size_bytes":3963971,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c2101fca2c714ca5a668327abc685888/download","mirrored":false},{"resource_id":"3efe45f20e2344738d77f4fe30a8d6f9","name":"Att. 1D._AJJY251073M RPR Rota Dorm B25017 35_ DSN Dwgs.pdf","kind":"file","mime_type":".pdf","size_bytes":24427159,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3efe45f20e2344738d77f4fe30a8d6f9/download","mirrored":false},{"resource_id":"c95193576cac4fa2a81aec5cba0feeef","name":"Att. 1C._AJJY251073M RPR Rota Dorm B25017 Map.pdf","kind":"file","mime_type":".pdf","size_bytes":2030913,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c95193576cac4fa2a81aec5cba0feeef/download","mirrored":false},{"resource_id":"d458b6753ff44652938b59a73891fcce","name":"Att. 1B._36 CES Contractor's BUILDER Inventory Sheet Template.xls","kind":"file","mime_type":".xls","size_bytes":628224,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d458b6753ff44652938b59a73891fcce/download","mirrored":false},{"resource_id":"a547a5d5a0604398a35e4d4668a92c3c","name":"Att. 1A._AAFB Contractor Antiterrorism Awareness.pdf","kind":"file","mime_type":".pdf","size_bytes":1289017,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a547a5d5a0604398a35e4d4668a92c3c/download","mirrored":false},{"resource_id":"7132ef007d044587abe778f09ba114ae","name":"Att. 01_SOW AJJY251073M RPR Rota Dorm B25017.pdf","kind":"file","mime_type":".pdf","size_bytes":528364,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7132ef007d044587abe778f09ba114ae/download","mirrored":false},{"resource_id":"70e2acf5a4194c5aaee947e44286c926","name":"Solicitation - FA524025R0003.pdf","kind":"file","mime_type":".pdf","size_bytes":1753204,"posted_at":"2025-06-13T07:32:18.111Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/70e2acf5a4194c5aaee947e44286c926/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_FA524025C0006_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_FA524025C0006_9700_-NONE-_-NONE-/","piid":"FA524025C0006","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"TSU2GQSJCGK7","recipient_name":"SEA PAC ENGINEERING INC","recipient_uei":"TSU2GQSJCGK7","recipient_cage":"04EN7","recipient_city":"LOS ANGELES","recipient_state":"CA","sub_name":"Department of the Air Force","office_name":"FA5240 36 CONS LGC","office_key":"o-FA5240","first_action_date":"2025-08-26","last_action_date":"2025-08-26","actions":1,"obligated":"34325690.00","current_total_value":"34325690.00","potential_total_value":"34325690.00","naics":"236220","psc":"Z2FC","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"HUBZONE SET-ASIDE","offers_received":5,"description":"AJJY 25-1073M REPAIR ROTA DORM B25017","method":"solicitation_as_piid","confidence":"high","evidence":["solicitation number FA524025C0006 was reused as the contract number","same awarding office FA5240"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"N6945027RP233","latest_notice_id":"2c675cdda8ef42a2842c5cbcb3d50727","title":"P233 AIR TRAFFIC CONTROL TOWER AND FLIGHT SIMULATOR TRAINING FACILITY","solicitation_number":"N6945027RP233","notice_type":"p","first_type":"r","first_posted":"2026-10-27","last_posted":"2026-11-10","notices":3,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N69450","office_name":"NAVFACSYSCOM SOUTHEAST","naics":"236220","psc":"Y1BA","set_aside":null,"state":"MS","county":"28047","county_name":"Harrison County","city":"2806220","city_name":"Biloxi","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Keesler Air Force Base","site_key":"keesler-air-force-base-ms","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C26027R00020006","latest_notice_id":"299fab9bad854b0786fcc742e3f934d5","title":"Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information","solicitation_number":"36C26027R0002-0006","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"N4008527R0047","latest_notice_id":"210d9a8ca71f45e3ba10457201d1f3d9","title":"P758 Machinery Control Development Center, Philadelphia Navy Yard, PA","solicitation_number":"N4008527R0047","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Y1JB","set_aside":null,"state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open_total":194,"indexable":false}