# 26 WPS - WT15754265 - Mini Split Upgrade

Canonical: https://sealedbidder.com/opportunities/fa486126q0018

- Solicitation number: FA486126Q0018
- Notice type: Solicitation
- Status: Closed. Deadline was August 20, 2026 at 5:00 PM EDT
- Department: Department of the Air Force
- Agency: Department of the Air Force
- Contracting office: FA4861 99 Cons LGC (FA4861)
- NAICS: 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Product or service code: Z2JZ Repair Or Alteration Of Miscellaneous Buildings
- Set-aside: Total small business set-aside
- Small business size standard: $19 million in average annual receipts (13 CFR 121.201, NAICS 238220)
- Location read from: the notice's place of performance: "B119, NELLIS AIR FORCE BASE, NV"
- First posted: July 22, 2026
- Last posted: August 13, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/1dbab732fc1b42eaa6a5db7b2487db7a/view

## Reading this notice

- Kind of notice: Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline.
- Who may compete: Total small business set-aside. Only small businesses may compete. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates.
- Time to respond: Bidders had 29 days from the day the solicitation was posted, July 22, 2026, to the deadline. The deadline moved once: it was first August 18, 2026 and ended as August 20, 2026.

## Description

Construct and install two maintenance pads to house all condensing units and provide single line as built drawings, install a two sided screen block at the front of the building matching the existing CMU block color and style, use solid and vented CMU blocks to ensure sufficient airflow around all condensing units, and build screen block walls two rows higher than the condensing units; the contractor shall supply a weatherproof 120V maintenance receptacle for each pad, core drill the existing wall of Building 119, install a 3 inch PVC pipe sealed with acoustical seal to maintain ICD 705 compliance per Tech Spec 1.5.1, install insulation on all line sets entering Building 119, run all electrical from Room 119s electrical mechanical room using panel EDH 1 3 rated at 480/277V and 800 amps, tie all new HVAC systems to the existing generator for backup power, surface mount electrical conduits in Room 119 and the exterior HVAC yard, run conduits underground to each maintenance pad, and supply a weatherproof disconnect for each condensing unit; the contractor shall install new cassette type HVAC systems in Rooms 112, 113, 114, and 132 using the existing suspended ceiling grid with added support, provide a 1 ton HVAC system with a separate controller for Room 112, provide 2 ton HVAC systems with separate controllers for Rooms 113 and 114, and provide a 4 ton HVAC system with a separate controller for Room 132; all design and construction shall comply with the current International Building Code, UFC standards, all applicable public laws, executive orders, CFR requirements, DOD instructions and directives, Nellis ID2 standards, and Clark County, Nevada, and federal codes and laws, and any discrepancies between codes or standards and contract documents shall be immediately reported to the Contracting Officer, with the more stringent requirement applying unless otherwise directed. 26 WPS request this HVAC installation and testing be accomplish within, 160 days, period of performance. Proposals will be evaluated using lowest price, technically acceptable. A site visit will take place on 8/4/2026 at 0830 AM PDT, meeting in front of building 119 main entrance. Please ensure your base pass request has been submitted to me by 2PM PDT on 7/24/2026 if you do not have base access to Nellis AFB to ensure you have access by the date of the site visit. Proposals are due by 8/18/2026 at 2:00 PDT. Answers will be provided via a solicitation amendment.

## Attachments

- [dodprocurementtoolbox.com](https://dodprocurementtoolbox.com/) (link)

## Open now in the same industry

59 open in NAICS 238220.

- REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS (W911PT27QA020), due November 25, 2026 at 1:00 PM EST. https://sealedbidder.com/opportunities/w911pt27qa020
- Modernize Regenerative Thermal Oxidizer (RTO) (2031ZA27B00001), due November 25, 2026 at 4:00 PM EST. https://sealedbidder.com/opportunities/2031za27b00001
- 13976 PUHO FIRE PROTECTION AT DORM (140PP027B0004), due November 25, 2026 at 10:00 PM EST. https://sealedbidder.com/opportunities/140pp027b0004

## Publications

- July 22, 2026: Solicitation, due August 18, 2026 at 5:00 PM EDT. Notice d7ae5520a976485c9818d5f1f7d508bd. https://sam.gov/workspace/contract/opp/d7ae5520a976485c9818d5f1f7d508bd/view
- July 23, 2026: Solicitation, due August 18, 2026 at 5:00 PM EDT. Notice 5bb29ed069034960a2a748073bf68497. https://sam.gov/workspace/contract/opp/5bb29ed069034960a2a748073bf68497/view
- August 5, 2026: Solicitation, due August 18, 2026 at 5:00 PM EDT. Notice 4b4b3aeb60f34089a846f9c2480a13d3. https://sam.gov/workspace/contract/opp/4b4b3aeb60f34089a846f9c2480a13d3/view
- August 13, 2026: Solicitation, due August 20, 2026 at 5:00 PM EDT. Notice 1dbab732fc1b42eaa6a5db7b2487db7a. https://sam.gov/workspace/contract/opp/1dbab732fc1b42eaa6a5db7b2487db7a/view

## Points of contact

- Donald Rhee, donald.rhee@us.af.mil, 7026795354
- William Vance, william.vance.6@us.af.mil, 7026792522

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/fa486126q0018.
