Sources sought, total small business set-aside
Inspection services for Fire Protection Systems
FA480025QA061
Department of the Air Force, FA4800 633 Cons PKP. Other Building Finishing Contractors.
Response deadline
April 18, 2025 at 5:00 PM EDT
Closed 586 days ago. Posted April 11, 2025, first published April 11, 2025. Scheduled to archive May 3, 2025.
Get the next one like this from Department of the Air Force by email, the day it is posted.Find my opportunities
This one closed in 2025
2 like it are open now in other building finishing contractors
- Weatherproofing Units
Department of the Navy, Commanding Officer
SolicitationSmall businessNAICS 238390Location not publishedN6339427Q4006Due todayNov 25 - Bldg. 81 Refresh and Remodel Restroom
Department of the Navy, Naval Undersea Warfare Center
Combined synopsis and solicitationSmall businessNAICS 238390Keyport, WAN0025327Q0005Closes in 23 daysDec 18
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 238390 (other building finishing contractors), means no more than $19 million in average annual receipts, counted with affiliates. Open Small business opportunities
- What comes next
- No solicitation was published under this number after the sources sought of April 11, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
SUBJECT: Sources Sought Inspection Services for Fire Protection Systems
1. Purpose:
The 633rd Contracting Squadron is conducting market research to identify potential sources capable of providing inspection services for fire protection systems, specifically thermal detectors. This is a Sources Sought notice, NOT a solicitation. The requirement involves inspections in Building 1102, Bays A and D, located within the Munitions Storage Area of Langley Air Force Base at 594 Worley Road, Hampton, VA, 23665. The government seeks a licensed engineer to perform these inspections. This Sources Sought is issued in accordance with FAR Subpart 12.6 and includes supplemental information.
The 633rd Contracting Squadron plans to award a firm-fixed-price (FFP) contract to a small business in accordance with the guidelines established in FAR Part 13 and the requirements outlined in this request, along with the attached Statement of Work (SOW).
2. Background:
Building 1102, Bays A & D, utilized for flare storage and processing, currently employs an automatic water sprinkler system that presents a significant hazard. A semi-annual fire drill conducted on December 7, 2023, highlighted this critical safety concern. These Class V assets require a "no water" fire suppression approach due to the significant ignition hazard posed by static electricity interacting with electrically initiated materials. Since March 2024, the 1st Munitions Squadron has been working to address this issue by procuring appropriate heat detectors, but has faced challenges identifying the correct type, quantity, pricing, and a suitable contractor. This building is occupied almost daily, and the current system poses a serious risk of rapid fire spread and potential loss of life should an incident occur. Therefore, we are reaching out to invite engineers with relevant expertise to collaborate with us in developing effective solutions. Details regarding the specific hazards associated with the current system, as well as the requirements for remediation, are outlined in the attached Statement of Work (SOW). We encourage you to review the SOW and work with us to ensure the safety of everyone in and around this facility. Your expertise could make a significant difference in mitigating this critical safety hazard.
3. Requirement Description
This requirement calls for upgrading the fire protection system in Building 1102's Chaff and Flare processing bay (Bays A & D) from a water-based sprinkler system to a heat detection system. The designated system shall utilize Honeywell Velociti Series 3 intelligent addressable heat detectors with point ID capability, complete with appropriate mounting bases, and integrated into the existing fire alarm control panel. The contractor will be responsible for conducting a comprehensive site survey to determine the necessary quantity and placement of detectors for complete regulatory compliance. Following the survey, the contractor will procure and install the specified heat detectors, setting individual detector addresses for precise location identification. Full system testing and verification will be required to ensure proper communication with the fire alarm control panel and accurate temperature monitoring. Finally, the contractor will deactivate the existing water-based sprinkler system upon successful heat detector system installation and testing. All work must adhere to applicable state and federal regulations. Interim fire watch will be maintained by Conventional Maintenance personnel until the new system is fully operational.
4. Anticipated Procurement Approach:
The procurement strategy is expected to be a competitive set-aside for small businesses, with an emphasis on compliance and pricing.
5. Response Requested:
Interested vendors are requested to provide the following information:
-
- Company Name
- Point of Contact Information (Name, Title, Phone, Email)
- Business Size (Small Business, Large Business, Other)
- Description of the proposed bus and size
- Estimate pricing information
6. Submission Instructions:
Responses and questions to this notice should be submitted via email to Kelly Voigts at kelly.voigts.3@us.af.mil no later than 5:00 PM EST, 18 April 2025.
7. Point of Contact:
For questions or further information regarding this notice, please contact Kelly Voigts at kelly.voigts.3@us.af.mil.
8. Conclusion:
This Sources Sought notice is for market research purposes only and does not serve as a solicitation. The information gathered will be utilized to shape the acquisition strategy. For further details, please refer to the attached SOW.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 1 MUNS Heat Detectors SOW (Final).pdf47 KB, April 11, 2025
- Sources Sought - 1 MUNS Heat Detectors.pdf114 KB, April 11, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 11, 2025
Sources sought
Fire Protection Services
Due April 18, 2025 at 5:00 PM EDT. SAM.gov, notice ac3f1d71d6f742589e33d0644a8f733f
2 revisions on SAM
- April 11, 2025: publish, sources sought
- April 11, 2025: publish, sources sought
April 11, 2025
Sources sought
Due April 18, 2025 at 5:00 PM EDT. SAM.gov, notice eeeeb5a4cffd4bdd91ce08832daf5cf8
2 revisions on SAM
- April 11, 2025: publish, sources sought
- April 11, 2025: publish, sources sought
Points of contact
- Kelly Voigtskelly.voigts.3@us.af.mil7572253150
- Margaret Youngmargaret.young.6@us.af.mil757225668