# COMPUTER ROOM AIR CONDITIONER (CRAC) REPLACEMENT at GRAND FORKS AFB, ND

Canonical: https://sealedbidder.com/opportunities/fa465926qz019

- Solicitation number: FA465926QZ019
- Notice type: Sources sought
- Status: Closed. Deadline was August 14, 2026 at 2:00 PM EDT
- Department: Department of the Air Force
- Agency: Department of the Air Force
- Contracting office: FA4659 319 Cons PK (FA4659)
- NAICS: 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Product or service code: 4130 Refrigeration and Air Conditioning Components
- Small business size standard: $19 million in average annual receipts (13 CFR 121.201, NAICS 238220)
- Place of performance: Grand Forks AFB, North Dakota
- Who can bid, by location: Anywhere in the US. Location does not limit who can bid: a product shipped to the buyer, research at the performer's facility, or work at the contractor's site. A state shown is the delivery point.
- County: Grand Forks County (FIPS 38035). https://sealedbidder.com/counties/grand-forks-county-nd-38035
- City: Grand Forks AFB. https://sealedbidder.com/cities/grand-forks-afb-nd-3832140
- First posted: August 7, 2026
- Last posted: August 7, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/66fa1abdeefc411588ed607836bd2268/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates.
- What comes next: No solicitation has been published under this number yet. The sources sought of August 7, 2026 is the earliest notice of the purchase.

## Description

Sources Sought: SAM Notice ID FA465926QZ019

COMPUTER ROOM AIR CONDITIONER (CRAC) REPLACEMENT at GRAND FORKS AFB, ND

THIS IS NOT A SOLICITATION!

This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.

This notice also serves to gain information and estimates on both purchasing the units with a four-year maintenance plan vs. renting with a four-year maintenance plan. Please provide two separate estimates in your response.

There is a need for Computer Room Air Conditioner (CRAC unit) at Grand Forks Air Force Base, ND. The requirement includes contractors removing and disposing of the current CRAC unit. They shall safely decommission, disconnect, and dispose of the existing legacy CRAC unit, associated pumps, and the existing dry cooler. All equipment, piping, fluid solutions, and debris shall become the property of the contractor. The contractor is responsible for the safe and proper transport and legal disposal of all materials off base, in strict accordance with local, state, and federal environmental regulations. The contractor will procure and install a dual CRAC unit system.

CRAC Units: Provide and install two (2) 8-Ton CRAC units. Both units must feature multi-stage cooling capabilities.

1. System must be capable of maintaining MCE internal temperature at 60 to 70 degrees Fahrenheit.

2. System must include integrated humidification and de-humidification capabilities designed to continuously maintain a relative humidity (RH) of 40% to 50%.

3. The systems shall operate using a solution comprised of 40% inhibited propylene glycol and 60% Reverse Osmosis (R.O.) water.

4. Each CRAC unit shall be equipped with separate, autonomous control systems, ensuring both units can operate fully independent of one another.

The contractor shall provide and install new dry coolers for each independent system. Dry coolers must be appropriately sized to support free-cooling operations. They shall also provide and install new, redundant pumps for each CRAC system. All pumps must be sized in strict accordance with the equipment manufacturer's requirements. New piping must be provided and installed for both systems, sized according to the manufacturer's specifications. The contractor shall provide and install movable ductwork designed to allow the backup CRAC unit to be quickly and efficiently connected to the MCE. They will provide O&M manuals and train 319 AMXS personnel on preventative maintenance, start/stop, and failover procedures. Lastly, they will conduct preventative maintenance based on equipment manufactures instructions and provide 24/7 emergency repair services for 4 years post acceptance.

All other information pertaining to this requirement can be found in the DRAFT PWS attached to this RFI.

The result of this market research will contribute to determining the method of procurement.

The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238220 - Plumbing, Heating, and Air-Conditioning Contractors

NOTE: If you believe the above NAICS to be incorrect please suggest alternate NAICS for this acquisition.

If your organization is willing and capable of providing the above-mentioned government needs, please respond with the following information:

Organization Name:

SAM UEI:

CAGE Code:

Business Type (Include all applicable designations):

Small Business Under NAICS &ndash; 238220? (Y/N):

POC Telephone Number:

POC Email:

Projected Delivery Date (XX number of days after award):

If you have an existing Government contract vehicle (GSA, NASA SEWP, NIH NITAAC etc.) that can provide this requirement, please provide the contract number:

All interested firms should submit a capabilities package that outlines the firm&rsquo;s ability to supply the requirements mentioned above. The capabilities package should be brief and concise yet clearly demonstrate the ability to meet the stated specifications and quantities. If teaming or subcontracting arrangements are anticipated, these should be clearly identified. The response must not exceed 5 pages.

WE ARE PRIMARILY SEEKING RESPONSES FROM SMALL BUSINESSES REGISTERED UNDER THE AFOREMENTIONED NAICS CODE; HOWEVER, ALL WILLING AND CAPABLE VENDORS ARE ENCOURAGED TO SUBMIT THEIR RESPONSE.

Submit all responses via email to SSgt Ellod Richardson at ellod.richardson@us.af.mil and SSgt Jhala N. Neupane at jhala.neupane@us.af.mil and TSgt Trenton Cott at  trenton.cott@us.af.mil no later than 14 AUGUST 2026, 1:00 PM CST.

## Attachments

- [CRAC 1.9 PWS - DRAFT.docx](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a4820abaaa7048bd97d93446cc3aaa3e/download)

## Open now in the same industry

57 open in NAICS 238220.

- 13976 PUHO FIRE PROTECTION AT DORM (140PP027B0004), due November 25, 2026 at 10:00 PM EST. https://sealedbidder.com/opportunities/140pp027b0004
- AK-AK MARITIME NWR-LEAK REPAIR (140FF027Q0080), due November 26, 2026 at 12:00 PM EST. https://sealedbidder.com/opportunities/140ff027q0080
- BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031 (36C26227Q0149), due November 27, 2026 at 12:00 PM EST. https://sealedbidder.com/opportunities/36c26227q0149

## Publications

- August 7, 2026: Sources sought, due August 14, 2026 at 2:00 PM EDT. Notice 66fa1abdeefc411588ed607836bd2268. https://sam.gov/workspace/contract/opp/66fa1abdeefc411588ed607836bd2268/view

## Points of contact

- SSgt Ellod Richardson, ellod.richardson@us.af.mil, 7017475314
- SSgt Jhala N. Neupane, jhala.neupane@us.af.mil, 7017474722

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/fa465926qz019.