{"canonical":"https://sealedbidder.com/opportunities/fa452826qsp03","key":"FA452826QSP03","url":"https://sealedbidder.com/opportunities/fa452826qsp03","title":"Bulk Oil/Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP03","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-30T16:00:00Z","first_posted":"2026-07-28","last_posted":"2026-07-28","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA4528 5 CONS","naics":"332420","psc":"5430","set_aside":"SBA","place_state":"ND","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"38101","place_county_name":"Ward County","place_city":"3853420","place_city_name":"Minot AFB","winner":null,"award_amount":null,"publications":[{"notice_id":"5155fb065b104a70887030f3f6843b8c","title":"Bulk Oil/Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP03","notice_type":"k","base_type":"k","posted":"2026-07-28","posted_at":"2026-07-28T13:43:58.262Z","due_at":"2026-07-30T21:00:00Z","due_date":"2026-07-30","cancelled":false,"archived":true,"archive_date":"2026-08-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5155fb065b104a70887030f3f6843b8c/view","enriched":true,"history":[{"index":3,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:47:26.738Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"653e11fb4d3547b791989a132627a7b1","solicitation_number":"FA452826QSP03","parent_opportunity_id":"5155fb065b104a70887030f3f6843b8c"},{"index":1,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:43:58.262Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5155fb065b104a70887030f3f6843b8c","solicitation_number":"FA452826QSP03"}]},{"notice_id":"653e11fb4d3547b791989a132627a7b1","title":"Bulk Oil/Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP03","notice_type":"k","base_type":"k","posted":"2026-07-28","posted_at":"2026-07-28T13:47:26.738Z","due_at":"2026-07-30T16:00:00Z","due_date":"2026-07-30","cancelled":false,"archived":true,"archive_date":"2026-08-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/653e11fb4d3547b791989a132627a7b1/view","enriched":true,"history":[{"index":3,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:47:26.738Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"653e11fb4d3547b791989a132627a7b1","solicitation_number":"FA452826QSP03","parent_opportunity_id":"5155fb065b104a70887030f3f6843b8c"},{"index":1,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:43:58.262Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5155fb065b104a70887030f3f6843b8c","solicitation_number":"FA452826QSP03"}]}],"latest_notice_id":"653e11fb4d3547b791989a132627a7b1","first_type":"k","notices":[{"dates":{"posted":"2026-07-28","posted_at":"2026-07-28T13:43:58.262Z","created_at":"2026-07-28T12:51:29.438Z","modified_at":"2026-08-14T05:07:07.281Z","response_deadline":{"raw":"2026-07-30T16:00:00-05:00","utc":"2026-07-30T21:00:00Z","date":"2026-07-30","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5155fb065b104a70887030f3f6843b8c/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Bulk Oil/Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_id":"500018248","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-14","archive_type":"auto15"},"history":[{"index":3,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:47:26.738Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"653e11fb4d3547b791989a132627a7b1","solicitation_number":"FA452826QSP03","parent_opportunity_id":"5155fb065b104a70887030f3f6843b8c"},{"index":1,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:43:58.262Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5155fb065b104a70887030f3f6843b8c","solicitation_number":"FA452826QSP03"}],"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"5155fb065b104a70887030f3f6843b8c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"5155fb065b104a70887030f3f6843b8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-27T03:26:46.890332960Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"4a8fafca683d871ab127d8bf8ec6dcc177c2d67947bb65b5b87fa7f57fbc59b6","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-27T03:26:46.890332960Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12&rsquo;W x 9&rsquo;D x 10&rsquo;H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant).</p>\n\n<p>The system must accommodate three different types of oil and one coolant. Key functional requirements include:</p>\n\n<p>Two (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line.</p>\n\n<p>An oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination.</p>\n\n<p>Two (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types.</p>\n\n<p>A mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types.</p>\n\n<p>Independent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines.</p>\n\n<p>Safety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for &quot;or equal&quot; products will be evaluated provided they meet all specified characteristics.</p>\n\n<p></p>","text":"The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12’W x 9’D x 10’H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant).\n\nThe system must accommodate three different types of oil and one coolant. Key functional requirements include:\n\nTwo (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line.\n\nAn oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination.\n\nTwo (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types.\n\nA mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types.\n\nIndependent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines.\n\nSafety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for \"or equal\" products will be evaluated provided they meet all specified characteristics.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP03","place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5430"},{"dates":{"posted":"2026-07-28","posted_at":"2026-07-28T13:47:26.738Z","created_at":"2026-07-28T13:46:02.632Z","modified_at":"2026-08-14T05:07:07.281Z","response_deadline":{"raw":"2026-07-30T11:00:00-05:00","utc":"2026-07-30T16:00:00Z","date":"2026-07-30","time":"11:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/653e11fb4d3547b791989a132627a7b1/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Bulk Oil/Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_id":"500018248","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-14","archive_type":"auto15"},"history":[{"index":3,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:47:26.738Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"653e11fb4d3547b791989a132627a7b1","solicitation_number":"FA452826QSP03","parent_opportunity_id":"5155fb065b104a70887030f3f6843b8c"},{"index":1,"title":"Bulk Oil/Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-28T13:43:58.262Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5155fb065b104a70887030f3f6843b8c","solicitation_number":"FA452826QSP03"}],"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"653e11fb4d3547b791989a132627a7b1","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"5155fb065b104a70887030f3f6843b8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-27T03:30:16.388334778Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"1bef7c81aadda0d901d40d1a15001a5bc0ccfa94b298eff63de2e6456a64e668","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-27T03:30:16.388334778Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12&rsquo;W x 9&rsquo;D x 10&rsquo;H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant).</p>\n\n<p>The system must accommodate three different types of oil and one coolant. Key functional requirements include:</p>\n\n<p>Two (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line.</p>\n\n<p>An oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination.</p>\n\n<p>Two (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types.</p>\n\n<p>A mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types.</p>\n\n<p>Independent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines.</p>\n\n<p>Safety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for &quot;or equal&quot; products will be evaluated provided they meet all specified characteristics.</p>\n\n<p></p>","text":"The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12’W x 9’D x 10’H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant).\n\nThe system must accommodate three different types of oil and one coolant. Key functional requirements include:\n\nTwo (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line.\n\nAn oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination.\n\nTwo (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types.\n\nA mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types.\n\nIndependent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines.\n\nSafety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for \"or equal\" products will be evaluated provided they meet all specified characteristics.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP03","place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5430"}],"due_at":"2026-07-30T16:00:00Z","due_date":"2026-07-30","closes_at":"2026-07-30T16:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-27T03:58:50.628596Z","principal_notice_id":"653e11fb4d3547b791989a132627a7b1","description":{"text":"The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12’W x 9’D x 10’H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant).\n\nThe system must accommodate three different types of oil and one coolant. Key functional requirements include:\n\nTwo (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line.\n\nAn oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination.\n\nTwo (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types.\n\nA mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types.\n\nIndependent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines.\n\nSafety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for \"or equal\" products will be evaluated provided they meet all specified characteristics.","html":"<p>The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12&rsquo;W x 9&rsquo;D x 10&rsquo;H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant).</p>\n\n<p>The system must accommodate three different types of oil and one coolant. Key functional requirements include:</p>\n\n<p>Two (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line.</p>\n\n<p>An oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination.</p>\n\n<p>Two (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types.</p>\n\n<p>A mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types.</p>\n\n<p>Independent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines.</p>\n\n<p>Safety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for &quot;or equal&quot; products will be evaluated provided they meet all specified characteristics.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"naics_codes":["332420"],"award":null,"attachments":[{"resource_id":"ed18dd3da8b149e4b89fc010f77b0be1","name":"Attachment 7- V2 FA452826C0008 Questions and Answers.pdf","kind":"file","mime_type":".pdf","size_bytes":78461,"posted_at":"2026-07-28T13:43:58.262Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ed18dd3da8b149e4b89fc010f77b0be1/download","mirrored":false}],"awards":[],"related":[{"key":"FA452827NCS01","latest_notice_id":"0ce974698c2745a3957351532b985969","title":"Notice of Intent to Single Source: VICADS Phase II, Minot AFB, ND","solicitation_number":"FA452827NCS01","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T15:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"561621","psc":"6350","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Minot Air Force Base","site_key":"minot-air-force-base-nd","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA452827Q0005","latest_notice_id":"8ff32b81695843f7ae0964f040f132e2","title":"FY 27 Fire Department Trainer Maintenance & Winterization/De-Winterization","solicitation_number":"FA452827Q0005","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-15T21:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"811310","psc":"J069","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"N0038326QSB78","latest_notice_id":"3751d118eb104b27a846c0afa3678638","title":"CYLINDER,COMPRESSED","solicitation_number":"N0038326QSB78","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-30T20:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00383","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT","naics":"332420","psc":"8120","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8120)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T03:50:03.904859Z"},{"key":"SPE7L327U0076","latest_notice_id":"a52eecc6a0c447448b2660dfbe38b072","title":"25--TANK,PRESSURE","solicitation_number":"SPE7L327U0076","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":null,"due_date":"2026-12-04","closes_at":"2026-12-05T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7L3","office_name":"DLA WEAPONS SUPPORT","naics":"332420","psc":"25","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 47. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":2,"indexable":false}