{"canonical":"https://sealedbidder.com/opportunities/fa452826qsp02","key":"FA452826QSP02","url":"https://sealedbidder.com/opportunities/fa452826qsp02","title":"Oil/ Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP02","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-16T21:00:00Z","first_posted":"2026-06-22","last_posted":"2026-07-08","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA4528 5 CONS","naics":"332420","psc":"5430","set_aside":"SBA","place_state":"ND","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"38101","place_county_name":"Ward County","place_city":"3853420","place_city_name":"Minot AFB","winner":null,"award_amount":null,"publications":[{"notice_id":"81d457bd18ab4b27ae5b92db357a190d","title":"Oil/ Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP02","notice_type":"k","base_type":"k","posted":"2026-06-22","posted_at":"2026-06-22T16:53:03.280Z","due_at":"2026-07-16T21:00:00Z","due_date":"2026-07-16","cancelled":false,"archived":true,"archive_date":"2026-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/81d457bd18ab4b27ae5b92db357a190d/view","enriched":true,"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}]},{"notice_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","title":"Oil/ Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP02","notice_type":"k","base_type":"k","posted":"2026-06-25","posted_at":"2026-06-25T18:54:21.521Z","due_at":"2026-07-16T21:00:00Z","due_date":"2026-07-16","cancelled":false,"archived":true,"archive_date":"2026-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/96dd9452d5db4a4ebaf8a28e00d13ac3/view","enriched":true,"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}]},{"notice_id":"ebc69390da6244d8b07bad1e1a69ef38","title":"Oil/ Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP02","notice_type":"k","base_type":"k","posted":"2026-06-25","posted_at":"2026-06-25T14:54:57.511Z","due_at":"2026-07-16T21:00:00Z","due_date":"2026-07-16","cancelled":false,"archived":true,"archive_date":"2026-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ebc69390da6244d8b07bad1e1a69ef38/view","enriched":true,"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}]},{"notice_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","title":"Oil/ Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP02","notice_type":"k","base_type":"k","posted":"2026-07-08","posted_at":"2026-07-08T21:22:03.731Z","due_at":"2026-07-16T21:00:00Z","due_date":"2026-07-16","cancelled":false,"archived":true,"archive_date":"2026-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cd0bb264c4d14fb6ad5a7e02e79ba7e5/view","enriched":true,"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}]}],"latest_notice_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","first_type":"k","notices":[{"dates":{"posted":"2026-06-22","posted_at":"2026-06-22T16:53:03.280Z","created_at":"2026-06-22T16:18:48.773Z","modified_at":"2026-07-27T22:11:32.228Z","response_deadline":{"raw":"2026-07-16T16:00:00-05:00","utc":"2026-07-16T21:00:00Z","date":"2026-07-16","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/81d457bd18ab4b27ae5b92db357a190d/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Oil/ Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_id":"500018248","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-31","archive_type":"auto15"},"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}],"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"81d457bd18ab4b27ae5b92db357a190d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"81d457bd18ab4b27ae5b92db357a190d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-01T03:42:26.950529554Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"734ec1acb75480809d5888845f1c7fb7276d66298c14640d2f7b1015993240c9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-01T03:42:26.950529554Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Name: Oil/Coolant Storage and Dispenser</p>\n\n<p>Make: <strong>NOT A BRAND NAME SET-ASIDE</strong> Lubrisource or <strong>equal</strong></p>\n\n<p>Model: HDL4-FS-0064-3W-2E-1F-1SP or equal</p>\n\n<p>The suggested brand name is Lubrisource; however, quotes for &quot;<strong>equal</strong>&quot; products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics</p>\n\n<p><strong>System Configuration &amp; Facility Requirements</strong></p>\n\n<p>Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).</p>\n\n<p>Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.</p>\n\n<p>Must operate on standard 115V power utilizing Type B plugs.</p>\n\n<p>Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.</p>\n\n<p>Eight (8) 65-Gallon aluminized steel, rectangular containers. Tanks must feature sloped bottoms and drain ports for easy cleaning.</p>\n\n<p>Fluid Capacities &amp; Coding</p>\n\n<p>System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids.</p>\n\n<p>Top-mounted ports must utilize 1 &frac12;&rdquo; Quick-Disconnect (QD) fittings connected to 2&rdquo; NPT ports.</p>\n\n<p>Top-mounted desiccant breathers featuring visual &quot;Color-Change&quot; indicators.</p>\n\n<p>Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.</p>\n\n<p>Two (2) 115V, minimum 8 GPM, self-priming gear pumps (or stronger) with suction tube assemblies. (One dedicated to Oil, one for Coolant).</p>\n\n<p>Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.</p>\n\n<p>Must include lockable dispensing ball valves.</p>\n\n<p>It must feature 10-micron inline filters prior to dispensing.</p>\n\n<p>Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.</p>\n\n<p>Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).</p>\n\n<p>Drip pans must be included. (Drain valves on drip pans are not required).</p>\n\n<p>All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.</p>\n\n<p></p>\n\n<p></p>","text":"Name: Oil/Coolant Storage and Dispenser\n\nMake: NOT A BRAND NAME SET-ASIDE Lubrisource or equal\n\nModel: HDL4-FS-0064-3W-2E-1F-1SP or equal\n\nThe suggested brand name is Lubrisource; however, quotes for \"equal\" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics\n\nSystem Configuration & Facility Requirements\n\nMust fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).\n\nStackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.\n\nMust operate on standard 115V power utilizing Type B plugs.\n\nEquipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.\n\nEight (8) 65-Gallon aluminized steel, rectangular containers. Tanks must feature sloped bottoms and drain ports for easy cleaning.\n\nFluid Capacities & Coding\n\nSystem must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids.\n\nTop-mounted ports must utilize 1 ½” Quick-Disconnect (QD) fittings connected to 2” NPT ports.\n\nTop-mounted desiccant breathers featuring visual \"Color-Change\" indicators.\n\nSight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.\n\nTwo (2) 115V, minimum 8 GPM, self-priming gear pumps (or stronger) with suction tube assemblies. (One dedicated to Oil, one for Coolant).\n\nTwo (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.\n\nMust include lockable dispensing ball valves.\n\nIt must feature 10-micron inline filters prior to dispensing.\n\nMust include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.\n\nSpill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).\n\nDrip pans must be included. (Drain valves on drip pans are not required).\n\nAll sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP02","place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5430"},{"dates":{"posted":"2026-06-25","posted_at":"2026-06-25T18:54:21.521Z","created_at":"2026-06-25T18:50:14.089Z","modified_at":"2026-07-27T22:11:32.228Z","response_deadline":{"raw":"2026-07-16T16:00:00-05:00","utc":"2026-07-16T21:00:00Z","date":"2026-07-16","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/96dd9452d5db4a4ebaf8a28e00d13ac3/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Oil/ Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_id":"500018248","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-31","archive_type":"auto15"},"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}],"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"81d457bd18ab4b27ae5b92db357a190d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-01T01:28:54.090763045Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"33e988df9561cf542ed5f77933b1a9b7a32b060ee9b71ff43d7e50ebdc5c3266","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-01T01:28:54.090763045Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Name: Oil/Coolant Storage and Dispenser</p>\n\n<p>Make: <strong>NOT A BRAND NAME SET-ASIDE</strong> Lubrisource or <strong>equal</strong></p>\n\n<p>Model: HDL4-FS-0064-3W-2E-1F-1SP or equal</p>\n\n<p>The suggested brand name is Lubrisource; however, quotes for &quot;<strong>equal</strong>&quot; products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics</p>\n\n<p><strong>System Configuration &amp; Facility Requirements</strong></p>\n\n<p>Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).</p>\n\n<p>Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.</p>\n\n<p>Must operate on Compressed Air</p>\n\n<p>Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.</p>\n\n<p>Four (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning.</p>\n\n<p>Fluid Capacities &amp; Coding</p>\n\n<p>System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.&nbsp;</p>\n\n<p>Top-mounted desiccant breathers featuring visual &quot;Color-Change&quot; indicators.</p>\n\n<p>Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.</p>\n\n<p>Two (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).</p>\n\n<p>Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.</p>\n\n<p>Must include lockable dispensing ball valves.</p>\n\n<p>It must feature 10-micron inline filters prior to dispensing.</p>\n\n<p>Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.</p>\n\n<p>Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).</p>\n\n<p>Drip pans must be included. (Drain valves on drip pans are not required).</p>\n\n<p>All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.</p>\n\n<p></p>\n\n<p></p>","text":"Name: Oil/Coolant Storage and Dispenser\n\nMake: NOT A BRAND NAME SET-ASIDE Lubrisource or equal\n\nModel: HDL4-FS-0064-3W-2E-1F-1SP or equal\n\nThe suggested brand name is Lubrisource; however, quotes for \"equal\" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics\n\nSystem Configuration & Facility Requirements\n\nMust fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).\n\nStackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.\n\nMust operate on Compressed Air\n\nEquipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.\n\nFour (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning.\n\nFluid Capacities & Coding\n\nSystem must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.\n\nTop-mounted desiccant breathers featuring visual \"Color-Change\" indicators.\n\nSight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.\n\nTwo (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).\n\nTwo (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.\n\nMust include lockable dispensing ball valves.\n\nIt must feature 10-micron inline filters prior to dispensing.\n\nMust include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.\n\nSpill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).\n\nDrip pans must be included. (Drain valves on drip pans are not required).\n\nAll sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP02","place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5430"},{"dates":{"posted":"2026-06-25","posted_at":"2026-06-25T14:54:57.511Z","created_at":"2026-06-25T14:45:20.482Z","modified_at":"2026-07-27T22:11:32.228Z","response_deadline":{"raw":"2026-07-16T16:00:00-05:00","utc":"2026-07-16T21:00:00Z","date":"2026-07-16","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ebc69390da6244d8b07bad1e1a69ef38/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Oil/ Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_id":"500018248","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-31","archive_type":"auto15"},"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}],"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"ebc69390da6244d8b07bad1e1a69ef38","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"81d457bd18ab4b27ae5b92db357a190d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-01T01:40:17.135213973Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"f635935e08a313626b54add4bcc80e646e3f5ed797af3401fe11e38c04e2309a","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-01T01:40:17.135213973Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Name: Oil/Coolant Storage and Dispenser</p>\n\n<p>Make: <strong>NOT A BRAND NAME SET-ASIDE</strong> Lubrisource or <strong>equal</strong></p>\n\n<p>Model: HDL4-FS-0064-3W-2E-1F-1SP or equal</p>\n\n<p>The suggested brand name is Lubrisource; however, quotes for &quot;<strong>equal</strong>&quot; products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics</p>\n\n<p><strong>System Configuration &amp; Facility Requirements</strong></p>\n\n<p>Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).</p>\n\n<p>Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.</p>\n\n<p>Must operate on Compressed Air</p>\n\n<p>Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.</p>\n\n<p>Eight (8) 65-Gallon aluminized steel, rectangular containers. Tanks must feature sloped bottoms and drain ports for easy cleaning.</p>\n\n<p>Fluid Capacities &amp; Coding</p>\n\n<p>System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.&nbsp;</p>\n\n<p>Top-mounted desiccant breathers featuring visual &quot;Color-Change&quot; indicators.</p>\n\n<p>Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.</p>\n\n<p>Two (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).</p>\n\n<p>Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.</p>\n\n<p>Must include lockable dispensing ball valves.</p>\n\n<p>It must feature 10-micron inline filters prior to dispensing.</p>\n\n<p>Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.</p>\n\n<p>Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).</p>\n\n<p>Drip pans must be included. (Drain valves on drip pans are not required).</p>\n\n<p>All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.</p>\n\n<p></p>\n\n<p></p>","text":"Name: Oil/Coolant Storage and Dispenser\n\nMake: NOT A BRAND NAME SET-ASIDE Lubrisource or equal\n\nModel: HDL4-FS-0064-3W-2E-1F-1SP or equal\n\nThe suggested brand name is Lubrisource; however, quotes for \"equal\" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics\n\nSystem Configuration & Facility Requirements\n\nMust fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).\n\nStackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.\n\nMust operate on Compressed Air\n\nEquipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.\n\nEight (8) 65-Gallon aluminized steel, rectangular containers. Tanks must feature sloped bottoms and drain ports for easy cleaning.\n\nFluid Capacities & Coding\n\nSystem must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.\n\nTop-mounted desiccant breathers featuring visual \"Color-Change\" indicators.\n\nSight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.\n\nTwo (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).\n\nTwo (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.\n\nMust include lockable dispensing ball valves.\n\nIt must feature 10-micron inline filters prior to dispensing.\n\nMust include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.\n\nSpill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).\n\nDrip pans must be included. (Drain valves on drip pans are not required).\n\nAll sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP02","place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5430"},{"dates":{"posted":"2026-07-08","posted_at":"2026-07-08T21:22:03.731Z","created_at":"2026-07-08T21:20:07.396Z","modified_at":"2026-07-27T22:11:32.228Z","response_deadline":{"raw":"2026-07-16T16:00:00-05:00","utc":"2026-07-16T21:00:00Z","date":"2026-07-16","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cd0bb264c4d14fb6ad5a7e02e79ba7e5/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Oil/ Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_id":"500018248","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-31","archive_type":"auto15"},"history":[{"index":5,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-07-27T22:11:32.228Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7a78c9bb7e42458c8deaa48c470ace5d","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":4,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-08T21:22:03.731Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":3,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T18:54:21.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"96dd9452d5db4a4ebaf8a28e00d13ac3","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":2,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-25T14:54:57.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"ebc69390da6244d8b07bad1e1a69ef38","solicitation_number":"FA452826QSP02","parent_opportunity_id":"81d457bd18ab4b27ae5b92db357a190d"},{"index":1,"title":"Oil/ Coolant Storage & Dispenser System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-22T16:53:03.280Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"81d457bd18ab4b27ae5b92db357a190d","solicitation_number":"FA452826QSP02"}],"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"81d457bd18ab4b27ae5b92db357a190d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T03:44:35.149687558Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"3559ee3ab6a0de5dab0b046110fad1386033bfc323922c59f778b1abab77c406","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T03:44:35.149687558Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Name: Oil/Coolant Storage and Dispenser</p>\n\n<p>Make: <strong>NOT A BRAND NAME SET-ASIDE</strong> Lubrisource or <strong>equal</strong></p>\n\n<p>Model: HDL4-FS-0064-3W-2E-1F-1SP or equal</p>\n\n<p>The suggested brand name is Lubrisource; however, quotes for &quot;<strong>equal</strong>&quot; products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics</p>\n\n<p><strong>System Configuration &amp; Facility Requirements</strong></p>\n\n<p>Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).</p>\n\n<p>Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.</p>\n\n<p>Must operate on Compressed Air</p>\n\n<p>Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.</p>\n\n<p>Four (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning.</p>\n\n<p>Fluid Capacities &amp; Coding</p>\n\n<p>System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.&nbsp;</p>\n\n<p>Top-mounted desiccant breathers featuring visual &quot;Color-Change&quot; indicators.</p>\n\n<p>Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.</p>\n\n<p>Two (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).</p>\n\n<p>Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.</p>\n\n<p>Must include lockable dispensing ball valves.</p>\n\n<p>It must feature 10-micron inline filters prior to dispensing.</p>\n\n<p>Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.</p>\n\n<p>Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).</p>\n\n<p>Drip pans must be included. (Drain valves on drip pans are not required).</p>\n\n<p>All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.</p>\n\n<p></p>\n\n<p></p>","text":"Name: Oil/Coolant Storage and Dispenser\n\nMake: NOT A BRAND NAME SET-ASIDE Lubrisource or equal\n\nModel: HDL4-FS-0064-3W-2E-1F-1SP or equal\n\nThe suggested brand name is Lubrisource; however, quotes for \"equal\" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics\n\nSystem Configuration & Facility Requirements\n\nMust fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).\n\nStackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.\n\nMust operate on Compressed Air\n\nEquipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.\n\nFour (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning.\n\nFluid Capacities & Coding\n\nSystem must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.\n\nTop-mounted desiccant breathers featuring visual \"Color-Change\" indicators.\n\nSight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.\n\nTwo (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).\n\nTwo (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.\n\nMust include lockable dispensing ball valves.\n\nIt must feature 10-micron inline filters prior to dispensing.\n\nMust include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.\n\nSpill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).\n\nDrip pans must be included. (Drain valves on drip pans are not required).\n\nAll sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP02","place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5430"}],"due_at":"2026-07-16T21:00:00Z","due_date":"2026-07-16","closes_at":"2026-07-16T21:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T04:14:25.251125Z","principal_notice_id":"cd0bb264c4d14fb6ad5a7e02e79ba7e5","description":{"text":"Name: Oil/Coolant Storage and Dispenser\n\nMake: NOT A BRAND NAME SET-ASIDE Lubrisource or equal\n\nModel: HDL4-FS-0064-3W-2E-1F-1SP or equal\n\nThe suggested brand name is Lubrisource; however, quotes for \"equal\" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics\n\nSystem Configuration & Facility Requirements\n\nMust fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).\n\nStackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.\n\nMust operate on Compressed Air\n\nEquipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.\n\nFour (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning.\n\nFluid Capacities & Coding\n\nSystem must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.\n\nTop-mounted desiccant breathers featuring visual \"Color-Change\" indicators.\n\nSight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.\n\nTwo (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).\n\nTwo (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.\n\nMust include lockable dispensing ball valves.\n\nIt must feature 10-micron inline filters prior to dispensing.\n\nMust include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.\n\nSpill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).\n\nDrip pans must be included. (Drain valves on drip pans are not required).\n\nAll sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.","html":"<p>Name: Oil/Coolant Storage and Dispenser</p>\n\n<p>Make: <strong>NOT A BRAND NAME SET-ASIDE</strong> Lubrisource or <strong>equal</strong></p>\n\n<p>Model: HDL4-FS-0064-3W-2E-1F-1SP or equal</p>\n\n<p>The suggested brand name is Lubrisource; however, quotes for &quot;<strong>equal</strong>&quot; products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics</p>\n\n<p><strong>System Configuration &amp; Facility Requirements</strong></p>\n\n<p>Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).</p>\n\n<p>Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.</p>\n\n<p>Must operate on Compressed Air</p>\n\n<p>Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.</p>\n\n<p>Four (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning.</p>\n\n<p>Fluid Capacities &amp; Coding</p>\n\n<p>System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard.&nbsp;</p>\n\n<p>Top-mounted desiccant breathers featuring visual &quot;Color-Change&quot; indicators.</p>\n\n<p>Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.</p>\n\n<p>Two (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant).</p>\n\n<p>Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.</p>\n\n<p>Must include lockable dispensing ball valves.</p>\n\n<p>It must feature 10-micron inline filters prior to dispensing.</p>\n\n<p>Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.</p>\n\n<p>Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).</p>\n\n<p>Drip pans must be included. (Drain valves on drip pans are not required).</p>\n\n<p>All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.</p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"place_of_performance":{"zip":"58704","city":{"code":"0","name":"Minot AFB"},"state":{"code":"ND","name":"North Dakota"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"naics_codes":["332420"],"award":null,"attachments":[{"resource_id":"2139616af7b0472eaeb4dce234fea61e","name":"Attachment 6 - PPIF.pdf","kind":"file","mime_type":".pdf","size_bytes":470942,"posted_at":"2026-06-22T16:53:03.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2139616af7b0472eaeb4dce234fea61e/download","mirrored":false},{"resource_id":"c82ad57d82314992b6c7adfae2b1e493","name":"Attachment 7- V1 FA452826C0008 Questions and Answers.pdf","kind":"file","mime_type":".pdf","size_bytes":78061,"posted_at":"2026-06-25T14:54:57.511Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c82ad57d82314992b6c7adfae2b1e493/download","mirrored":false},{"resource_id":"fab34482c23e47549cd5319e26544fa8","name":"Attachment 7- V2 FA452826C0008 Questions and Answers.pdf","kind":"file","mime_type":".pdf","size_bytes":78461,"posted_at":"2026-07-08T21:22:03.731Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fab34482c23e47549cd5319e26544fa8/download","mirrored":false}],"awards":[],"related":[{"key":"FA452827NCS01","latest_notice_id":"0ce974698c2745a3957351532b985969","title":"Notice of Intent to Single Source: VICADS Phase II, Minot AFB, ND","solicitation_number":"FA452827NCS01","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T15:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"561621","psc":"6350","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Minot Air Force Base","site_key":"minot-air-force-base-nd","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA452827Q0005","latest_notice_id":"8ff32b81695843f7ae0964f040f132e2","title":"FY 27 Fire Department Trainer Maintenance & Winterization/De-Winterization","solicitation_number":"FA452827Q0005","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-15T21:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"811310","psc":"J069","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"N0038326QSB78","latest_notice_id":"3751d118eb104b27a846c0afa3678638","title":"CYLINDER,COMPRESSED","solicitation_number":"N0038326QSB78","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-30T20:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00383","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT","naics":"332420","psc":"8120","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8120)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T03:50:03.904859Z"},{"key":"SPE7L327U0076","latest_notice_id":"a52eecc6a0c447448b2660dfbe38b072","title":"25--TANK,PRESSURE","solicitation_number":"SPE7L327U0076","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":null,"due_date":"2026-12-04","closes_at":"2026-12-05T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7L3","office_name":"DLA WEAPONS SUPPORT","naics":"332420","psc":"25","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 47. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":2,"indexable":false}