# 459MXS Equipment Ventilation

Canonical: https://sealedbidder.com/opportunities/fa286025q4051

- Solicitation number: FA286025Q4051
- Notice type: Sources sought
- Status: Closed. Deadline was August 27, 2025 at 4:00 PM EDT
- Department: Department of the Air Force
- Agency: Department of the Air Force
- Contracting office: FA2860 316 Cons PK (FA2860)
- NAICS: 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Product or service code: J041 Maintenance, Repair and Rebuilding of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment
- Set-aside: Total small business set-aside
- Small business size standard: $19 million in average annual receipts (13 CFR 121.201, NAICS 238220)
- Place of performance: JB Andrews, Maryland
- County: Prince George's County (FIPS 24033). https://sealedbidder.com/counties/prince-george-s-county-md-24033
- First posted: August 22, 2025
- Last posted: August 22, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/28228e98a3b343b69e65204fc9dc35b5/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: Total small business set-aside. Only small businesses may compete. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates.
- What comes next: No solicitation was published under this number after the sources sought of August 22, 2025. An agency sometimes issues the solicitation under a new number.

## Description

Provide and install 8" CPVC pipe and fittings from the existing parts washer exhaust pipe to outside the building. The existing 8&rdquo; CVPC pipe will need to be extended and supported vertically approximately 14 feet. Then the pipe will need to run horizontally approximately 28 feet and exit building above the hangar doors on the north side of hangar 11. The horizontal pipe will need to be supported from the concrete ceiling as required. The ceiling is approximately 3 feet above where the horizontal pipe will run. The area that the vent will exit the building is corrugated steel and will need to be cut to allow for the exhaust pipe to exit the hangar. This area will need to be sealed around the exhaust pipe once installed. The exhaust pipe will also require some type of barrier to prevent birds and other rodents from entering.

-See attached statement of work and photos for more information.

***This sources sought is for market research only and does not obligate the Government. It is not a solicitation and cannot be accepted to form a contract. The Government will not reimburse costs for responding, and no work is authorized without a contract signed by a warranted Contracting Officer.***

## Attachments

- [Hangar 11 Parts Washer Vent Statement of Work.docx](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e4f4e288c5ac497288387fae5cf62181/download)

## Open now in the same industry

57 open in NAICS 238220.

- 13976 PUHO FIRE PROTECTION AT DORM (140PP027B0004), due November 25, 2026 at 10:00 PM EST. https://sealedbidder.com/opportunities/140pp027b0004
- AK-AK MARITIME NWR-LEAK REPAIR (140FF027Q0080), due November 26, 2026 at 12:00 PM EST. https://sealedbidder.com/opportunities/140ff027q0080
- BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031 (36C26227Q0149), due November 27, 2026 at 12:00 PM EST. https://sealedbidder.com/opportunities/36c26227q0149

## Publications

- August 22, 2025: Sources sought, due August 27, 2025 at 4:00 PM EDT. Notice 28228e98a3b343b69e65204fc9dc35b5. https://sam.gov/workspace/contract/opp/28228e98a3b343b69e65204fc9dc35b5/view

## Points of contact

- Amn Zwe Naing, zwe.naing@us.af.mil
- TSgt Andrea Begens, andrea.begens@us.af.mil

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/fa286025q4051.