{"canonical":"https://sealedbidder.com/opportunities/fa255024q0024","key":"FA255024Q0024","url":"https://sealedbidder.com/opportunities/fa255024q0024","title":"Delta 8 B300 Conduit Install","solicitation_number":"FA255024Q0024","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2024-07-31T19:00:00Z","first_posted":"2024-07-03","last_posted":"2024-07-29","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA2550 50 CONS PKP","naics":"238210","psc":"5975","set_aside":"SBA","place_state":"CO","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"08041","place_county_name":"El Paso County","place_city":"0816000","place_city_name":"Colorado Springs","winner":"SILVER NATIONAL CORP.","award_amount":null,"publications":[{"notice_id":"d2a3537010ee45ca9993772ac5e1730d","title":"Delta 8 B300 Conduit Install","solicitation_number":"FA255024Q0024","notice_type":"k","base_type":"k","posted":"2024-07-03","posted_at":null,"due_at":"2024-07-31T19:00:00Z","due_date":"2024-07-31","cancelled":null,"archived":null,"archive_date":"2024-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d2a3537010ee45ca9993772ac5e1730d/view","enriched":false,"history":[]},{"notice_id":"d672a1ccbc5446069fa934c12dd81deb","title":"Delta 8 B300 Conduit Install","solicitation_number":"FA255024Q0024","notice_type":"k","base_type":"k","posted":"2024-07-15","posted_at":null,"due_at":"2024-07-31T19:00:00Z","due_date":"2024-07-31","cancelled":null,"archived":null,"archive_date":"2024-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d672a1ccbc5446069fa934c12dd81deb/view","enriched":false,"history":[]},{"notice_id":"7f3d46e0fe114398b138ed6d053d17a6","title":"Delta 8 B300 Conduit Install","solicitation_number":"FA255024Q0024","notice_type":"k","base_type":"k","posted":"2024-07-24","posted_at":null,"due_at":"2024-07-31T19:00:00Z","due_date":"2024-07-31","cancelled":null,"archived":null,"archive_date":"2024-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7f3d46e0fe114398b138ed6d053d17a6/view","enriched":false,"history":[]},{"notice_id":"b606da0a71574d04a9e61290e059f58c","title":"Delta 8 B300 Conduit Install","solicitation_number":"FA255024Q0024","notice_type":"k","base_type":"k","posted":"2024-07-26","posted_at":null,"due_at":"2024-07-31T19:00:00Z","due_date":"2024-07-31","cancelled":null,"archived":null,"archive_date":"2024-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b606da0a71574d04a9e61290e059f58c/view","enriched":false,"history":[]},{"notice_id":"2a1612ccbe374ecfa5e92e20076998f0","title":"Delta 8 B300 Conduit Install","solicitation_number":"FA255024Q0024","notice_type":"k","base_type":"k","posted":"2024-07-29","posted_at":null,"due_at":"2024-07-31T19:00:00Z","due_date":"2024-07-31","cancelled":null,"archived":null,"archive_date":"2024-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2a1612ccbe374ecfa5e92e20076998f0/view","enriched":false,"history":[]}],"latest_notice_id":"2a1612ccbe374ecfa5e92e20076998f0","first_type":"k","notices":[{"dates":{"posted":"2024-07-03","response_deadline":{"raw":"2024-07-31T13:00:00-06:00","utc":"2024-07-31T19:00:00Z","date":"2024-07-31","time":"13:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d2a3537010ee45ca9993772ac5e1730d/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Delta 8 B300 Conduit Install","agency":{"office":{"code":"FA2550","name":"FA2550 50 CONS PKP"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"80912-2116","city":"SCHRIEVER SFB","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-15","archive_type":"auto15"},"contacts":[{"name":"Melanie A. Briggs","role":"primary","email":"melanie.briggs.2@spaceforce.mil","phone":"7195673898"},{"name":"Alejandro Castellanos","role":"secondary","email":"alejandro.castellanos@spaceforce.mil","phone":"7195676185"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"d2a3537010ee45ca9993772ac5e1730d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"1dd5ea9a46c172be8e6e70da94c25627c216b5f1b98e03606fe451f479432be8","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Delta 8 CTS requires the following work for B300, Rooms 242, 243, 246, and 248: · Installation of (2) 2” rigid conduit with sealed fittings. · Installation of approximately 250 feet of 2” x 4” wire basket tray for future workstations. · Installation of ground system to include conveyance, ground bar, and grounding of pathways. · Installation shall be done according to applicable regulations and safety standards. Provide and install a total of (3) wall-mounted cabinets sized 24” High X 24” Wide X 30” Depth. One in Room 243, one in Room 246, one in Room 242. The wall mounted cabinets shall have a fiberoptic LIU, of sufficient capacity to accommodate all backbone cabling. Each cabinet shall be grounded to a ground bar located near each cabinet. · Provide and install firestop material in all Telecommunications conduit sleeves in required areas. · Provide, install, terminate, and test a total of (2) OM4, 6 Strand Multi-Mode Fiber Optic Cables. The first from Room 243 to Room 246, and the second from Room 243 to Room 242. These cables shall be terminated using LC connectors. (Note: All above ceiling cables shall be plenum rated) · Contracted procurement of necessary equipment · Cleanup and trash removal shall be included.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA255024Q0024","place_of_performance":{"zip":"80912","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"5975"},{"dates":{"posted":"2024-07-15","response_deadline":{"raw":"2024-07-31T13:00:00-06:00","utc":"2024-07-31T19:00:00Z","date":"2024-07-31","time":"13:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d672a1ccbc5446069fa934c12dd81deb/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Delta 8 B300 Conduit Install","agency":{"office":{"code":"FA2550","name":"FA2550 50 CONS PKP"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"80912-2116","city":"SCHRIEVER SFB","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-15","archive_type":"auto15"},"contacts":[{"name":"Melanie A. Briggs","role":"primary","email":"melanie.briggs.2@spaceforce.mil","phone":"7195673898"},{"name":"Alejandro Castellanos","role":"secondary","email":"alejandro.castellanos@spaceforce.mil","phone":"7195676185"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"d672a1ccbc5446069fa934c12dd81deb","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"3bcf3a5dc79dfa781fc531e67370b1809709a005e07d23f2a06143e7962852f0","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Delta 8 CTS requires the following work for B300, Rooms 242, 243, 246, and 248: · Installation of (2) 2” rigid conduit with sealed fittings. · Installation of approximately 250 feet of 2” x 4” wire basket tray for future workstations. · Installation of ground system to include conveyance, ground bar, and grounding of pathways. · Installation shall be done according to applicable regulations and safety standards. Provide and install a total of (3) wall-mounted cabinets sized 24” High X 24” Wide X 30” Depth. One in Room 243, one in Room 246, one in Room 242. The wall mounted cabinets shall have a fiberoptic LIU, of sufficient capacity to accommodate all backbone cabling. Each cabinet shall be grounded to a ground bar located near each cabinet. · Provide and install firestop material in all Telecommunications conduit sleeves in required areas. · Provide, install, terminate, and test a total of (2) OM4, 6 Strand Multi-Mode Fiber Optic Cables. The first from Room 243 to Room 246, and the second from Room 243 to Room 242. These cables shall be terminated using LC connectors. (Note: All above ceiling cables shall be plenum rated) · Contracted procurement of necessary equipment · Cleanup and trash removal shall be included.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA255024Q0024","place_of_performance":{"zip":"80912","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"5975"},{"dates":{"posted":"2024-07-24","response_deadline":{"raw":"2024-07-31T13:00:00-06:00","utc":"2024-07-31T19:00:00Z","date":"2024-07-31","time":"13:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7f3d46e0fe114398b138ed6d053d17a6/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Delta 8 B300 Conduit Install","agency":{"office":{"code":"FA2550","name":"FA2550 50 CONS PKP"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"80912-2116","city":"SCHRIEVER SFB","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-15","archive_type":"auto15"},"contacts":[{"name":"Melanie A. Briggs","role":"primary","email":"melanie.briggs.2@spaceforce.mil","phone":"7195673898"},{"name":"Alejandro Castellanos","role":"secondary","email":"alejandro.castellanos@spaceforce.mil","phone":"7195676185"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"7f3d46e0fe114398b138ed6d053d17a6","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"eb3524c16afee0223ea8f5a63230e73e1c8e5b367391561763c50b9d7133311e","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Delta 8 CTS requires the following work for B300, Rooms 242, 243, 246, and 248: · Installation of (2) 2” rigid conduit with sealed fittings. · Installation of approximately 250 feet of 2” x 4” wire basket tray for future workstations. · Installation of ground system to include conveyance, ground bar, and grounding of pathways. · Installation shall be done according to applicable regulations and safety standards. Provide and install a total of (3) wall-mounted cabinets sized 24” High X 24” Wide X 30” Depth. One in Room 243, one in Room 246, one in Room 242. The wall mounted cabinets shall have a fiberoptic LIU, of sufficient capacity to accommodate all backbone cabling. Each cabinet shall be grounded to a ground bar located near each cabinet. · Provide and install firestop material in all Telecommunications conduit sleeves in required areas. · Provide, install, terminate, and test a total of (2) OM4, 6 Strand Multi-Mode Fiber Optic Cables. The first from Room 243 to Room 246, and the second from Room 243 to Room 242. These cables shall be terminated using LC connectors. (Note: All above ceiling cables shall be plenum rated) · Contracted procurement of necessary equipment · Cleanup and trash removal shall be included. Amendment 0001 Questions and Answers have been uploaded. No other changes have been made.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA255024Q0024","place_of_performance":{"zip":"80912","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"5975"},{"dates":{"posted":"2024-07-26","response_deadline":{"raw":"2024-07-31T13:00:00-06:00","utc":"2024-07-31T19:00:00Z","date":"2024-07-31","time":"13:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b606da0a71574d04a9e61290e059f58c/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Delta 8 B300 Conduit Install","agency":{"office":{"code":"FA2550","name":"FA2550 50 CONS PKP"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"80912-2116","city":"SCHRIEVER SFB","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-15","archive_type":"auto15"},"contacts":[{"name":"Melanie A. Briggs","role":"primary","email":"melanie.briggs.2@spaceforce.mil","phone":"7195673898"},{"name":"Alejandro Castellanos","role":"secondary","email":"alejandro.castellanos@spaceforce.mil","phone":"7195676185"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"b606da0a71574d04a9e61290e059f58c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"67a2d7ef17597c19a3f089b65be1b9fee131c570cec8818f2d823f229b39427f","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Delta 8 CTS requires the following work for B300, Rooms 242, 243, 246, and 248: · Installation of (2) 2” rigid conduit with sealed fittings. · Installation of approximately 250 feet of 2” x 4” wire basket tray for future workstations. · Installation of ground system to include conveyance, ground bar, and grounding of pathways. · Installation shall be done according to applicable regulations and safety standards. Provide and install a total of (3) wall-mounted cabinets sized 24” High X 24” Wide X 30” Depth. One in Room 243, one in Room 246, one in Room 242. The wall mounted cabinets shall have a fiberoptic LIU, of sufficient capacity to accommodate all backbone cabling. Each cabinet shall be grounded to a ground bar located near each cabinet. · Provide and install firestop material in all Telecommunications conduit sleeves in required areas. · Provide, install, terminate, and test a total of (2) OM4, 6 Strand Multi-Mode Fiber Optic Cables. The first from Room 243 to Room 246, and the second from Room 243 to Room 242. These cables shall be terminated using LC connectors. (Note: All above ceiling cables shall be plenum rated) · Contracted procurement of necessary equipment · Cleanup and trash removal shall be included. Amendment 0001 Questions and Answers have been uploaded. No other changes have been made. Amendment 0002 - 26 July 2024 Revised PWS removing paragrahs 4.1 and 4.2 in reference to modular furniture. See PWS dated 26 July 2024. Revised Questions and Answers correcting the answer to question #12. Offer due date remains unchanged.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA255024Q0024","place_of_performance":{"zip":"80912","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"5975"},{"dates":{"posted":"2024-07-29","response_deadline":{"raw":"2024-07-31T13:00:00-06:00","utc":"2024-07-31T19:00:00Z","date":"2024-07-31","time":"13:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2a1612ccbe374ecfa5e92e20076998f0/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Delta 8 B300 Conduit Install","agency":{"office":{"code":"FA2550","name":"FA2550 50 CONS PKP"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"80912-2116","city":"SCHRIEVER SFB","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-15","archive_type":"auto15"},"contacts":[{"name":"Melanie A. Briggs","role":"primary","email":"melanie.briggs.2@spaceforce.mil","phone":"7195673898"},{"name":"Alejandro Castellanos","role":"secondary","email":"alejandro.castellanos@spaceforce.mil","phone":"7195676185"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"2a1612ccbe374ecfa5e92e20076998f0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"b0088b719f2cad0643838212c292db87cb48f7096bf82a97f21c01ee7e59e6a1","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Delta 8 CTS requires the following work for B300, Rooms 242, 243, 246, and 248: · Installation of (2) 2” rigid conduit with sealed fittings. · Installation of approximately 250 feet of 2” x 4” wire basket tray for future workstations. · Installation of ground system to include conveyance, ground bar, and grounding of pathways. · Installation shall be done according to applicable regulations and safety standards. Provide and install a total of (3) wall-mounted cabinets sized 24” High X 24” Wide X 30” Depth. One in Room 243, one in Room 246, one in Room 242. The wall mounted cabinets shall have a fiberoptic LIU, of sufficient capacity to accommodate all backbone cabling. Each cabinet shall be grounded to a ground bar located near each cabinet. · Provide and install firestop material in all Telecommunications conduit sleeves in required areas. · Provide, install, terminate, and test a total of (2) OM4, 6 Strand Multi-Mode Fiber Optic Cables. The first from Room 243 to Room 246, and the second from Room 243 to Room 242. These cables shall be terminated using LC connectors. (Note: All above ceiling cables shall be plenum rated) · Contracted procurement of necessary equipment · Cleanup and trash removal shall be included. Amendment 0001 Questions and Answers have been uploaded. No other changes have been made. Amendment 0002 - 26 July 2024 Revised SOW removing paragrahs 4.1 and 4.2 in reference to modular furniture. See SOW dated 26 July 2024. Revised Questions and Answers correcting the answer to question #12. Offer due date remains unchanged. Amendment 0003 - 29 July 2024 Revised SOW removing paragraphs pertaining to modular furniture. Furniture is not inluded in this soliciattion. See SOW dated 29 July 2024. Offer due date remains unchanged.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA255024Q0024","place_of_performance":{"zip":"80912","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"5975"}],"due_at":"2024-07-31T19:00:00Z","due_date":"2024-07-31","closes_at":"2024-07-31T19:00:00Z","awardable":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA2550","office_name":"FA2550 50 CONS PKP","state":"CO","county":"08041","county_name":"El Paso County","city":"0816000","city_name":"Colorado Springs","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"V4DCMK73CL21","amount":null,"linked_awards":5,"cancelled":false,"archived":false,"updated_at":"2026-09-24T03:25:58.922164Z","principal_notice_id":"2a1612ccbe374ecfa5e92e20076998f0","description":{"text":"Delta 8 CTS requires the following work for B300, Rooms 242, 243, 246, and 248: · Installation of (2) 2” rigid conduit with sealed fittings. · Installation of approximately 250 feet of 2” x 4” wire basket tray for future workstations. · Installation of ground system to include conveyance, ground bar, and grounding of pathways. · Installation shall be done according to applicable regulations and safety standards. Provide and install a total of (3) wall-mounted cabinets sized 24” High X 24” Wide X 30” Depth. One in Room 243, one in Room 246, one in Room 242. The wall mounted cabinets shall have a fiberoptic LIU, of sufficient capacity to accommodate all backbone cabling. Each cabinet shall be grounded to a ground bar located near each cabinet. · Provide and install firestop material in all Telecommunications conduit sleeves in required areas. · Provide, install, terminate, and test a total of (2) OM4, 6 Strand Multi-Mode Fiber Optic Cables. The first from Room 243 to Room 246, and the second from Room 243 to Room 242. These cables shall be terminated using LC connectors. (Note: All above ceiling cables shall be plenum rated) · Contracted procurement of necessary equipment · Cleanup and trash removal shall be included. Amendment 0001 Questions and Answers have been uploaded. No other changes have been made. Amendment 0002 - 26 July 2024 Revised SOW removing paragrahs 4.1 and 4.2 in reference to modular furniture. See SOW dated 26 July 2024. Revised Questions and Answers correcting the answer to question #12. Offer due date remains unchanged. Amendment 0003 - 29 July 2024 Revised SOW removing paragraphs pertaining to modular furniture. Furniture is not inluded in this soliciattion. See SOW dated 29 July 2024. Offer due date remains unchanged.","html":null,"origin":"extract"},"contacts":[{"name":"Melanie A. Briggs","role":"primary","email":"melanie.briggs.2@spaceforce.mil","phone":"7195673898"},{"name":"Alejandro Castellanos","role":"secondary","email":"alejandro.castellanos@spaceforce.mil","phone":"7195676185"}],"place_of_performance":{"zip":"80912","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"office_address":{"zip":"80912-2116","city":"SCHRIEVER SFB","state":"CO","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_FA255024P0028_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_FA255024P0028_9700_-NONE-_-NONE-/","piid":"FA255024P0028","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"V4DCMK73CL21","recipient_name":"SILVER NATIONAL CORP.","recipient_uei":"V4DCMK73CL21","recipient_cage":"9WGW0","recipient_city":"BAY SHORE","recipient_state":"NY","sub_name":"Department of the Air Force","office_name":"FA2550 50 CONS PKP","office_key":"o-FA2550","first_action_date":"2024-08-12","last_action_date":"2024-08-12","actions":1,"obligated":"36607.00","current_total_value":"36607.00","potential_total_value":"36607.00","naics":"238210","psc":"5975","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":6,"description":"DELTA 8 CTS INSTALLATION OF CONDUITS, BASKET TRAYS, GROUNDING SYSTEM, WALL MOUNTED CABINETS, AND FIBER OPTIC CABLES FOR B300, ROOMS 242, 243, 246, AND 248","method":"solicitation","confidence":"high","evidence":["solicitation number FA255024Q0024 equals the FPDS solicitation identifier","same awarding office FA2550"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"FA251727SS00","latest_notice_id":"bc4fcb32914347a685b0b332444ceedb","title":"Sources Sought: Smart T Power Project","solicitation_number":"FA251727SS00","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2027-11-18T16:00:00Z","due_date":"2027-11-18","closes_at":"2027-11-18T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA2517","office_name":"FA2517 21 CONS BLDG 350","naics":"238210","psc":"N059","set_aside":"SBA","state":"CO","county":"08041","county_name":"El Paso County","city":"0816000","city_name":"Colorado Springs","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C24627Q0114","latest_notice_id":"9464cbfda7004348805568dfa367e88c","title":"5975--INSTALLATION OF PROXIMITY SENSORS FOR AUTOMATIC DOORS","solicitation_number":"36C24627Q0114","notice_type":"o","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238210","psc":"5975","set_aside":null,"state":"NC","county":"37051","county_name":"Cumberland County","city":"3722920","city_name":"Fayetteville","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":"Product purchase (PSC 5975)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"1232SA27Q0021","latest_notice_id":"8c35373e3e5c4e3bb88b3fb51c3ea2c1","title":"Electrical Installation of 5-Station Cubicle and One Single Hotel Desk Arrangement","solicitation_number":"1232SA27Q0021","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-1232SA","office_name":"USDA ARS AFM APD","naics":"238210","psc":"N059","set_aside":"SBA","state":"WI","county":"55025","county_name":"Dane County","city":"5548000","city_name":"Madison","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":42,"indexable":false}